Skip to main content
Top
Published in: Maxillofacial Plastic and Reconstructive Surgery 1/2019

Open Access 01-12-2019 | Methodology

Chair side measuring instrument for quantification of the extent of a transverse maxillary occlusal plane cant

Authors: Farhad B. Naini, Ashraf Messiha, Daljit S. Gill

Published in: Maxillofacial Plastic and Reconstructive Surgery | Issue 1/2019

Login to get access

Abstract

Background

Treatment planning the correction of a transverse maxillary occlusal plane cant often involves a degree of qualitative “eyeballing”, with the attendant possibility of error in the estimated judgement. A simple chair side technique permits quantification of the extent of asymmetry and thereby quantitative measurements for the correction of the occlusal plane cant.

Methods

A measuring instrument may be constructed by soldering the edge of a stainless steel dental ruler at 90° to the flat surface of a similar ruler. With the patient either standing in natural head position, or alternatively seated upright in the dental chair, and a dental photographic retractor in situ, the flat under-surface of the horizontal part of this measuring instrument is placed on a unilateral segment of a bilateral structure, e.g. the higher maxillary canine orthodontic bracket hook. The vertical ruler is held next to the contralateral canine tooth, and the vertical distance measured directly from the canine bracket to the flat under-surface of the horizontal part of the measuring instrument.

Results

This vertical distance quantifies the overall extent of movement required to level the maxillary occlusal plane.

Conclusions

This measuring instrument and simple chair side technique helps to quantify the overall extent of surgical levelling required and may be a useful additional technique in our clinical diagnostic armamentarium.
Literature
1.
go back to reference Naini FB (2011) Facial symmetry and asymmetry. In: Naini FB. Facial aesthetics: concepts and clinical diagnosis. Wiley-Blackwell, Oxford Naini FB (2011) Facial symmetry and asymmetry. In: Naini FB. Facial aesthetics: concepts and clinical diagnosis. Wiley-Blackwell, Oxford
2.
go back to reference Naini FB, Manisali M, Gill DS (2017) Asymmetries of the maxilla and mandible. In: Naini FB, Gill DS (eds) Orthognathic surgery: principles, planning and practice. Wiley-Blackwell, Oxford Naini FB, Manisali M, Gill DS (2017) Asymmetries of the maxilla and mandible. In: Naini FB, Gill DS (eds) Orthognathic surgery: principles, planning and practice. Wiley-Blackwell, Oxford
3.
go back to reference Quevedo L, Ruiz JV, Quevedo C (2011) Using a clinical protocol for orthognathic surgery and assessing a 3-dimensional virtual approach: current therapy. J Oral Maxillofac Surg 69:623–637CrossRef Quevedo L, Ruiz JV, Quevedo C (2011) Using a clinical protocol for orthognathic surgery and assessing a 3-dimensional virtual approach: current therapy. J Oral Maxillofac Surg 69:623–637CrossRef
4.
go back to reference Xia JJ, Gateno J, Teichgraeber JF (2009) New clinical protocol to evaluate craniomaxillofacial deformity and plan surgical correction. J Oral Maxillofac Surg 67:2093–2106CrossRef Xia JJ, Gateno J, Teichgraeber JF (2009) New clinical protocol to evaluate craniomaxillofacial deformity and plan surgical correction. J Oral Maxillofac Surg 67:2093–2106CrossRef
5.
go back to reference Barbenel JC, Paul PE, Khambay BS, Walker FS, Moos KF, Ayoub AF (2010) Errors in orthognathic surgery planning: the effect of inaccurate study model orientation. Int J Oral Maxillofac Surg 39:1103–1108CrossRef Barbenel JC, Paul PE, Khambay BS, Walker FS, Moos KF, Ayoub AF (2010) Errors in orthognathic surgery planning: the effect of inaccurate study model orientation. Int J Oral Maxillofac Surg 39:1103–1108CrossRef
6.
go back to reference Zhao L, Patel PK, Cohen M (2012) Application of virtual surgical planning with computer assisted design and manufacturing technology to cranio-maxillo-facial surgery. Arch Plastic Surg 39:309–316CrossRef Zhao L, Patel PK, Cohen M (2012) Application of virtual surgical planning with computer assisted design and manufacturing technology to cranio-maxillo-facial surgery. Arch Plastic Surg 39:309–316CrossRef
Metadata
Title
Chair side measuring instrument for quantification of the extent of a transverse maxillary occlusal plane cant
Authors
Farhad B. Naini
Ashraf Messiha
Daljit S. Gill
Publication date
01-12-2019
Publisher
Springer Berlin Heidelberg
Published in
Maxillofacial Plastic and Reconstructive Surgery / Issue 1/2019
Electronic ISSN: 2288-8586
DOI
https://doi.org/10.1186/s40902-019-0204-6

Other articles of this Issue 1/2019

Maxillofacial Plastic and Reconstructive Surgery 1/2019 Go to the issue