Skip to main content
Top
Published in: European Spine Journal 6/2016

01-06-2016 | Original Article

Cervical pedicle screw placement using intraoperative computed tomography imaging with a mobile scanner gantry

Authors: Toshitaka Yoshii, Takashi Hirai, Kenichiro Sakai, Hiroyuki Inose, Tsuyoshi Kato, Atsushi Okawa

Published in: European Spine Journal | Issue 6/2016

Login to get access

Abstract

Purpose

A multi-detector computed tomography (CT) imaging system with a mobile scanner gantry in the operating room can provide intraoperative reconstructed images with a high resolution. We devised a technique for cervical pedicle screw (CPS) placement using the mobile CT system and evaluated the accuracy of this technique.

Methods

Forty-eight patients who underwent cervical fixation using CPSs were prospectively enrolled in this study. Initial pedicle probing was performed approximately to the depth of the posterior aspect of the vertebral body using fluoroscopic lateral view, and a marking pin was put in place. Intraoperative CT images were obtained to confirm whether the position of the marking pin was accurate. After adequate modification of the trajectory was performed, an appropriately sized CPS was inserted. The accuracy of the CPS was evaluated using postoperative reconstructed CT images, and compared with a historical control group of 22 patients (CPS insertion using only fluoroscopy).

Results

A total of 193 CPSs were inserted. Intraoperative CT images demonstrated that 12.4 % of the initial probings were not accurate, and modification of the trajectory was required. On postoperative CT, 92.7 % of the CPSs were found to be placed accurately: the accuracy was significantly higher than the control group (80.9 %). In the cases using intraoperative CT images, only 1.0 % of the screws were judged to show grade 2 screw misplacement; no neurovascular complications associated with screw placement were observed.

Conclusions

The technique of CPS placement using mobile CT was shown to be safe and effective in preventing catastrophic complications associated with CPS insertion.
Literature
1.
go back to reference Abumi K, Shono Y, Ito M, Taneichi H, Kotani Y, Kaneda K (2000) Complications of pedicle screw fixation in reconstructive surgery of the cervical spine. Spine 25:962–969CrossRefPubMed Abumi K, Shono Y, Ito M, Taneichi H, Kotani Y, Kaneda K (2000) Complications of pedicle screw fixation in reconstructive surgery of the cervical spine. Spine 25:962–969CrossRefPubMed
3.
go back to reference Karaikovic EE, Kunakornsawat S, Daubs MD, Madsen TW, Gaines RW Jr (2000) Surgical anatomy of the cervical pedicles: landmarks for posterior cervical pedicle entrance localization. J Spinal Disord 13:63–72CrossRefPubMed Karaikovic EE, Kunakornsawat S, Daubs MD, Madsen TW, Gaines RW Jr (2000) Surgical anatomy of the cervical pedicles: landmarks for posterior cervical pedicle entrance localization. J Spinal Disord 13:63–72CrossRefPubMed
4.
5.
go back to reference Kanna PR, Shetty AP, Rajasekaran S (2011) Anatomical feasibility of pediatric cervical pedicle screw insertion by computed tomographic morphometric evaluation of 376 pediatric cervical pedicles. Spine (Phila Pa 1976) 36:1297–1304. doi:10.1097/BRS.0b013e3181fb3c17 CrossRef Kanna PR, Shetty AP, Rajasekaran S (2011) Anatomical feasibility of pediatric cervical pedicle screw insertion by computed tomographic morphometric evaluation of 376 pediatric cervical pedicles. Spine (Phila Pa 1976) 36:1297–1304. doi:10.​1097/​BRS.​0b013e3181fb3c17​ CrossRef
8.
go back to reference Ishikawa Y, Kanemura T, Yoshida G, Ito Z, Muramoto A, Ohno S (2010) Clinical accuracy of three-dimensional fluoroscopy-based computer-assisted cervical pedicle screw placement: a retrospective comparative study of conventional versus computer-assisted cervical pedicle screw placement. J Neurosurg Spine 13:606–611. doi:10.3171/2010.5.SPINE09993 CrossRefPubMed Ishikawa Y, Kanemura T, Yoshida G, Ito Z, Muramoto A, Ohno S (2010) Clinical accuracy of three-dimensional fluoroscopy-based computer-assisted cervical pedicle screw placement: a retrospective comparative study of conventional versus computer-assisted cervical pedicle screw placement. J Neurosurg Spine 13:606–611. doi:10.​3171/​2010.​5.​SPINE09993 CrossRefPubMed
9.
go back to reference Hojo Y, Ito M, Suda K, Oda I, Yoshimoto H, Abumi K (2014) A multicenter study on accuracy and complications of freehand placement of cervical pedicle screws under lateral fluoroscopy in different pathological conditions: CT-based evaluation of more than 1,000 screws. Eur Spine J 23:2166–2174. doi:10.1007/s00586-014-3470-0 CrossRefPubMed Hojo Y, Ito M, Suda K, Oda I, Yoshimoto H, Abumi K (2014) A multicenter study on accuracy and complications of freehand placement of cervical pedicle screws under lateral fluoroscopy in different pathological conditions: CT-based evaluation of more than 1,000 screws. Eur Spine J 23:2166–2174. doi:10.​1007/​s00586-014-3470-0 CrossRefPubMed
10.
go back to reference Lu S, Xu YQ, Lu WW, Ni GX, Li YB, Shi JH, Li DP, Chen GP, Chen YB, Zhang YZ (2009) A novel patient-specific navigational template for cervical pedicle screw placement. Spine (Phila Pa 1976) 34:E959–E966. doi:10.1097/BRS.0b013e3181c09985 CrossRef Lu S, Xu YQ, Lu WW, Ni GX, Li YB, Shi JH, Li DP, Chen GP, Chen YB, Zhang YZ (2009) A novel patient-specific navigational template for cervical pedicle screw placement. Spine (Phila Pa 1976) 34:E959–E966. doi:10.​1097/​BRS.​0b013e3181c09985​ CrossRef
11.
go back to reference Kaneyama S, Sugawara T, Sumi M (2015) Safe and accurate mid-cervical pedicle Screw insertion procedure with the patient-specific SCREW guide template system. Spine (Phila Pa 1976). doi:10.1097/BRS.0000000000000772 Kaneyama S, Sugawara T, Sumi M (2015) Safe and accurate mid-cervical pedicle Screw insertion procedure with the patient-specific SCREW guide template system. Spine (Phila Pa 1976). doi:10.​1097/​BRS.​0000000000000772​
13.
go back to reference Ishikawa Y, Kanemura T, Yoshida G, Matsumoto A, Ito Z, Tauchi R, Muramoto A, Ohno S, Nishimura Y (2011) Intraoperative, full-rotation, three-dimensional image (O-arm)-based navigation system for cervical pedicle screw insertion. J Neurosurg Spine 15:472–478. doi:10.3171/2011.6.SPINE10809 CrossRefPubMed Ishikawa Y, Kanemura T, Yoshida G, Matsumoto A, Ito Z, Tauchi R, Muramoto A, Ohno S, Nishimura Y (2011) Intraoperative, full-rotation, three-dimensional image (O-arm)-based navigation system for cervical pedicle screw insertion. J Neurosurg Spine 15:472–478. doi:10.​3171/​2011.​6.​SPINE10809 CrossRefPubMed
14.
go back to reference Uehara M, Takahashi J, Ikegami S, Mukaiyama K, Kuraishi S, Shimizu M, Futatsugi T, Ogihara N, Hashidate H, Hirabayashi H, Kato H (2014) Screw perforation features in 129 consecutive patients performed computer-guided cervical pedicle screw insertion. Eur Spine J 23:2189–2195. doi:10.1007/s00586-014-3502-9 CrossRefPubMed Uehara M, Takahashi J, Ikegami S, Mukaiyama K, Kuraishi S, Shimizu M, Futatsugi T, Ogihara N, Hashidate H, Hirabayashi H, Kato H (2014) Screw perforation features in 129 consecutive patients performed computer-guided cervical pedicle screw insertion. Eur Spine J 23:2189–2195. doi:10.​1007/​s00586-014-3502-9 CrossRefPubMed
15.
go back to reference Abumi K, Shono Y, Taneichi H, Ito M, Kaneda K (1999) Correction of cervical kyphosis using pedicle screw fixation systems. Spine (Phila Pa 1976) 24:2389–2396CrossRef Abumi K, Shono Y, Taneichi H, Ito M, Kaneda K (1999) Correction of cervical kyphosis using pedicle screw fixation systems. Spine (Phila Pa 1976) 24:2389–2396CrossRef
16.
go back to reference Kotani Y, Abumi K, Ito M, Minami A (2003) Improved accuracy of computer-assisted cervical pedicle screw insertion. J Neurosurg 99:257–263PubMed Kotani Y, Abumi K, Ito M, Minami A (2003) Improved accuracy of computer-assisted cervical pedicle screw insertion. J Neurosurg 99:257–263PubMed
17.
go back to reference Ebraheim NA, Xu R, Knight T, Yeasting RA (1997) Morphometric evaluation of lower cervical pedicle and its projection. Spine (Phila Pa 1976) 22:1–6CrossRef Ebraheim NA, Xu R, Knight T, Yeasting RA (1997) Morphometric evaluation of lower cervical pedicle and its projection. Spine (Phila Pa 1976) 22:1–6CrossRef
18.
go back to reference Jones EL, Heller JG, Silcox DH, Hutton WC (1997) Cervical pedicle screws versus lateral mass screws Anatomic feasibility and biomechanical comparison. Spine (Phila Pa 1976) 22:977–982CrossRef Jones EL, Heller JG, Silcox DH, Hutton WC (1997) Cervical pedicle screws versus lateral mass screws Anatomic feasibility and biomechanical comparison. Spine (Phila Pa 1976) 22:977–982CrossRef
19.
20.
go back to reference Bydon M, Xu R, Amin AG, Macki M, Kaloostian P, Sciubba DM, Wolinsky JP, Bydon A, Gokaslan ZL, Witham TF (2014) Safety and efficacy of pedicle screw placement using intraoperative computed tomography: consecutive series of 1148 pedicle screws. J Neurosurg Spine 21:320–328. doi:10.3171/2014.5.SPINE13567 CrossRefPubMed Bydon M, Xu R, Amin AG, Macki M, Kaloostian P, Sciubba DM, Wolinsky JP, Bydon A, Gokaslan ZL, Witham TF (2014) Safety and efficacy of pedicle screw placement using intraoperative computed tomography: consecutive series of 1148 pedicle screws. J Neurosurg Spine 21:320–328. doi:10.​3171/​2014.​5.​SPINE13567 CrossRefPubMed
21.
go back to reference Scheufler KM, Franke J, Eckardt A, Dohmen H (2011) Accuracy of image-guided pedicle screw placement using intraoperative computed tomography-based navigation with automated referencing. Part II: thoracolumbar spine. Neurosurgery 69:1307–1316. doi:10.1227/NEU.0b013e31822ba190 CrossRefPubMed Scheufler KM, Franke J, Eckardt A, Dohmen H (2011) Accuracy of image-guided pedicle screw placement using intraoperative computed tomography-based navigation with automated referencing. Part II: thoracolumbar spine. Neurosurgery 69:1307–1316. doi:10.​1227/​NEU.​0b013e31822ba190​ CrossRefPubMed
22.
go back to reference Gelalis ID, Paschos NK, Pakos EE, Politis AN, Arnaoutoglou CM, Karageorgos AC, Ploumis A, Xenakis TA (2012) Accuracy of pedicle screw placement: a systematic review of prospective in vivo studies comparing free hand, fluoroscopy guidance and navigation techniques. Eur Spine J 21:247–255. doi:10.1007/s00586-011-2011-3 CrossRefPubMedPubMedCentral Gelalis ID, Paschos NK, Pakos EE, Politis AN, Arnaoutoglou CM, Karageorgos AC, Ploumis A, Xenakis TA (2012) Accuracy of pedicle screw placement: a systematic review of prospective in vivo studies comparing free hand, fluoroscopy guidance and navigation techniques. Eur Spine J 21:247–255. doi:10.​1007/​s00586-011-2011-3 CrossRefPubMedPubMedCentral
23.
go back to reference Kamimura M, Ebara S, Itoh H, Tateiwa Y, Kinoshita T, Takaoka K (2000) Cervical pedicle screw insertion: assessment of safety and accuracy with computer-assisted image guidance. J Spinal Disord 13:218–224CrossRefPubMed Kamimura M, Ebara S, Itoh H, Tateiwa Y, Kinoshita T, Takaoka K (2000) Cervical pedicle screw insertion: assessment of safety and accuracy with computer-assisted image guidance. J Spinal Disord 13:218–224CrossRefPubMed
Metadata
Title
Cervical pedicle screw placement using intraoperative computed tomography imaging with a mobile scanner gantry
Authors
Toshitaka Yoshii
Takashi Hirai
Kenichiro Sakai
Hiroyuki Inose
Tsuyoshi Kato
Atsushi Okawa
Publication date
01-06-2016
Publisher
Springer Berlin Heidelberg
Published in
European Spine Journal / Issue 6/2016
Print ISSN: 0940-6719
Electronic ISSN: 1432-0932
DOI
https://doi.org/10.1007/s00586-016-4508-2

Other articles of this Issue 6/2016

European Spine Journal 6/2016 Go to the issue