Skip to main content
Top
Published in: International Journal of Computer Assisted Radiology and Surgery 6/2013

01-11-2013 | Original Article

Cerebrovascular segmentation and planning of depth electrode insertion for epilepsy surgery

Authors: Xiaofei Du, Hui Ding, Wenjing Zhou, Guangming Zhang, Guangzhi Wang

Published in: International Journal of Computer Assisted Radiology and Surgery | Issue 6/2013

Login to get access

Abstract

Purpose

Depth electrodes are inserted in the brain to locate the epileptogenic zone without craniotomy, but there is risk of surgical hemorrhage. Preoperative planning is required to mitigate this risk. A preoperative imaging, segmentation and three dimensional (3D) visualization procedure was developed to provide neurosurgeons with cortical and vascular anatomy information for surgical planning and neuronavigation.

Methods

Cerebral vascular imaging was performed with phase-contrast magnetic resonance angiography (PC-MRA). Fuzzy c-means was performed to extract brain parenchyma from the PC-MRA images. A multi-scale vessel enhancement filter and thresholding process were combined to segment the vasculature and suppress background noise in the PC-MRA images. Finally, 3D visualization of the vasculature and cortical structures was implemented using volume rendering.

Results

Quantitative and qualitative validation of the vascular segmentation method were done. Using manual vascular segmentation as the gold standard, our method produced a satisfactory result: sensitivity was as high as 90 % at a specificity level of 95 %. Moreover, comparing the 3D visualizations of the vasculature and cortical structure for 4 patients with their respective intraoperative craniotomy photographs showed high levels of similarity.

Conclusion

A new automated segmentation and visualization procedure provides sufficient and accurate cortical and vascular anatomy information compared to intraoperative photographs. This method has potential to assist neurosurgeons with planning and neuronavigation for depth electrode insertion with avoidance of cerebral hemorrhage.
Literature
2.
go back to reference Baillet S, Mosher JC, Leahy RM (2001) Electromagnetic brain mapping. IEEE Sign Process Mag 18(6):14–30CrossRef Baillet S, Mosher JC, Leahy RM (2001) Electromagnetic brain mapping. IEEE Sign Process Mag 18(6):14–30CrossRef
4.
go back to reference Olivier A, Boling WW, Tanriverdi T (2012) Techniques in epilepsy surgery: the MNI approach. Cambridge University Press, CambridgeCrossRef Olivier A, Boling WW, Tanriverdi T (2012) Techniques in epilepsy surgery: the MNI approach. Cambridge University Press, CambridgeCrossRef
5.
go back to reference Brontë-Stewart H, Louie S, Batya S, Henderson JM (2010) Clinical motor outcome of bilateral subthalamic nucleus deep-brain stimulation for Parkinson’s disease using image-guided frameless stereotaxy. Neurosurgery 67(4):1088PubMedCrossRef Brontë-Stewart H, Louie S, Batya S, Henderson JM (2010) Clinical motor outcome of bilateral subthalamic nucleus deep-brain stimulation for Parkinson’s disease using image-guided frameless stereotaxy. Neurosurgery 67(4):1088PubMedCrossRef
6.
go back to reference Chakravarty MM, Sadikot AF, Mongia S, Bertrand G, Collins DL (2006) Towards a multi-modal atlas for neurosurgical planning. In: Medical image computing and computer-assisted intervention-MICCAI 2006. Springer, pp 389–396 Chakravarty MM, Sadikot AF, Mongia S, Bertrand G, Collins DL (2006) Towards a multi-modal atlas for neurosurgical planning. In: Medical image computing and computer-assisted intervention-MICCAI 2006. Springer, pp 389–396
7.
go back to reference Holloway KL, Gaede SE, Starr PA, Rosenow JM, Ramakrishnan V, Henderson JM (2005) Frameless stereotaxy using bone fiducial markers for deep brain stimulation. J Neurosurg 103(3):404–413PubMedCrossRef Holloway KL, Gaede SE, Starr PA, Rosenow JM, Ramakrishnan V, Henderson JM (2005) Frameless stereotaxy using bone fiducial markers for deep brain stimulation. J Neurosurg 103(3):404–413PubMedCrossRef
8.
go back to reference Machado A, Rezai AR, Kopell BH, Gross RE, Sharan AD, Benabid AL (2006) Deep brain stimulation for Parkinson’s disease: surgical technique and perioperative management. Mov Disord 21(S14):S247–S258PubMedCrossRef Machado A, Rezai AR, Kopell BH, Gross RE, Sharan AD, Benabid AL (2006) Deep brain stimulation for Parkinson’s disease: surgical technique and perioperative management. Mov Disord 21(S14):S247–S258PubMedCrossRef
9.
go back to reference Liu Y, Dawant BM, Pallavaram S, Neimat JS, Konrad PE, D’Haese P-F, Datteri RD, Landman BA, Noble JH A surgeon specific automatic path planning algorithm for deep brain stimulation. In: SPIE medical imaging, 2012. international society for optics and photonics, pp 83161D–83161D Liu Y, Dawant BM, Pallavaram S, Neimat JS, Konrad PE, D’Haese P-F, Datteri RD, Landman BA, Noble JH A surgeon specific automatic path planning algorithm for deep brain stimulation. In: SPIE medical imaging, 2012. international society for optics and photonics, pp 83161D–83161D
10.
go back to reference Brunenberg EJ, Vilanova A, Visser-Vandewalle V, Temel Y, Ackermans L, Platel B, ter Haar Romeny BM (2007) Automatic trajectory planning for deep brain stimulation: a feasibility study. In: Medical image computing and computer-assisted intervention-MICCAI 2007. Springer, pp 584–592 Brunenberg EJ, Vilanova A, Visser-Vandewalle V, Temel Y, Ackermans L, Platel B, ter Haar Romeny BM (2007) Automatic trajectory planning for deep brain stimulation: a feasibility study. In: Medical image computing and computer-assisted intervention-MICCAI 2007. Springer, pp 584–592
11.
go back to reference Essert C, Haegelen C, Lalys F, Abadie A, Jannin P (2012) Automatic computation of electrode trajectories for Deep Brain Stimulation: a hybrid symbolic and numerical approach. Int J Comput Assist Radiol Surg 7(4):517–532PubMedCrossRef Essert C, Haegelen C, Lalys F, Abadie A, Jannin P (2012) Automatic computation of electrode trajectories for Deep Brain Stimulation: a hybrid symbolic and numerical approach. Int J Comput Assist Radiol Surg 7(4):517–532PubMedCrossRef
12.
go back to reference Shamir RR, Joskowicz L, Tamir I, Dabool E, Pertman L, Ben-Ami A, Shoshan Y (2012) Reduced risk trajectory planning in image-guided keyhole neurosurgery. Med Phys 39:2885PubMedCrossRef Shamir RR, Joskowicz L, Tamir I, Dabool E, Pertman L, Ben-Ami A, Shoshan Y (2012) Reduced risk trajectory planning in image-guided keyhole neurosurgery. Med Phys 39:2885PubMedCrossRef
13.
go back to reference Bériault S, Al Subaie F (2012) A multi-modal approach to computer-assisted deep brain stimulation trajectory planning. Int J Comput Assist Radiol Surg 7(5):687–704PubMedCrossRef Bériault S, Al Subaie F (2012) A multi-modal approach to computer-assisted deep brain stimulation trajectory planning. Int J Comput Assist Radiol Surg 7(5):687–704PubMedCrossRef
14.
go back to reference Smith ML, Elliott IM, Lach L (2002) Cognitive skills in children with intractable epilepsy: comparison of surgical and nonsurgical candidates. Epilepsia 43(6):631–637PubMedCrossRef Smith ML, Elliott IM, Lach L (2002) Cognitive skills in children with intractable epilepsy: comparison of surgical and nonsurgical candidates. Epilepsia 43(6):631–637PubMedCrossRef
15.
go back to reference Campeau NG, Huston J III (2001) Magnetic resonance angiography at 3.0 Tesla: initial clinical experience. Top Magn Reson Imag 12(3):183–204CrossRef Campeau NG, Huston J III (2001) Magnetic resonance angiography at 3.0 Tesla: initial clinical experience. Top Magn Reson Imag 12(3):183–204CrossRef
16.
go back to reference Essig M, Giesel FL (2008) Head and neck MRA. In: Clinical blood pool MR imaging. Springer, pp 59–68 Essig M, Giesel FL (2008) Head and neck MRA. In: Clinical blood pool MR imaging. Springer, pp 59–68
17.
go back to reference Maki JH, Chenevert TL, Prince MR (1996) Three-dimensional contrast-enhanced MR angiography. Top Magn Reson Imag 8(6):322–344CrossRef Maki JH, Chenevert TL, Prince MR (1996) Three-dimensional contrast-enhanced MR angiography. Top Magn Reson Imag 8(6):322–344CrossRef
18.
go back to reference Thomsen HS, Marckmann P, Logager VB (2007) Nephrogenic systemic fibrosis (NSF): a late adverse reaction to some of the gadolinium based contrast agents. Cancer Imag 7(1):130CrossRef Thomsen HS, Marckmann P, Logager VB (2007) Nephrogenic systemic fibrosis (NSF): a late adverse reaction to some of the gadolinium based contrast agents. Cancer Imag 7(1):130CrossRef
19.
go back to reference Vu D, González RG, Schaefer PW (2006) Conventional MRI and MR angiography of stroke. In: Acute ischemic stroke. Springer, pp 115–137 Vu D, González RG, Schaefer PW (2006) Conventional MRI and MR angiography of stroke. In: Acute ischemic stroke. Springer, pp 115–137
20.
go back to reference Nishimura DG (2005) Time-of-flight MR angiography. Magn Reson Med 14(2):194–201CrossRef Nishimura DG (2005) Time-of-flight MR angiography. Magn Reson Med 14(2):194–201CrossRef
21.
go back to reference Reichenbach JR, Venkatesan R, Schillinger DJ, Kido DK, Haacke EM (1997) Small vessels in the human brain: MR venography with deoxyhemoglobin as an intrinsic contrast agent. Radiology 204(1):272–277PubMed Reichenbach JR, Venkatesan R, Schillinger DJ, Kido DK, Haacke EM (1997) Small vessels in the human brain: MR venography with deoxyhemoglobin as an intrinsic contrast agent. Radiology 204(1):272–277PubMed
22.
go back to reference Yucel EK (1995) Magnetic resonance angiography: a practical approach. McGraw-Hill, Health Professions Division, New York Yucel EK (1995) Magnetic resonance angiography: a practical approach. McGraw-Hill, Health Professions Division, New York
23.
go back to reference Ng A, Johnston L, Chen Z, Cho ZH, Zhang J, Egan G (2011) Spatially dependent filtering for removing phase distortions at the cortical surface. Magn Reson Med 66(3):784–793PubMedCrossRef Ng A, Johnston L, Chen Z, Cho ZH, Zhang J, Egan G (2011) Spatially dependent filtering for removing phase distortions at the cortical surface. Magn Reson Med 66(3):784–793PubMedCrossRef
24.
go back to reference Dumoulin C (1995) Phase contrast MR angiography techniques. Magn Reson Imag Clin N Am 3(3):399 Dumoulin C (1995) Phase contrast MR angiography techniques. Magn Reson Imag Clin N Am 3(3):399
25.
go back to reference Pernicone J, Siebert JE, Potchen E, Pera A, Dumoulin C, Souza S (1990) Three-dimensional phase-contrast MR angiography in the head and neck: preliminary report. Am J Roentgenol 155(1): 167–176 Pernicone J, Siebert JE, Potchen E, Pera A, Dumoulin C, Souza S (1990) Three-dimensional phase-contrast MR angiography in the head and neck: preliminary report. Am J Roentgenol 155(1): 167–176
26.
go back to reference Ross DA, Brunberg JA, Drury I, Henry TR (1996) Intracerebral depth electrode monitoring in partial epilepsy: the morbidity and efficacy of placement using magnetic resonance image-guided stereotactic surgery. Neurosurgery 39(2):327–334 Ross DA, Brunberg JA, Drury I, Henry TR (1996) Intracerebral depth electrode monitoring in partial epilepsy: the morbidity and efficacy of placement using magnetic resonance image-guided stereotactic surgery. Neurosurgery 39(2):327–334
27.
go back to reference Bezdek JC, Ehrlich R, Full W (1984) FCM: the fuzzy c-means clustering algorithm. Comput Geosci 10(2):191–203 Bezdek JC, Ehrlich R, Full W (1984) FCM: the fuzzy c-means clustering algorithm. Comput Geosci 10(2):191–203
28.
go back to reference Hall LO, Bensaid AM, Clarke LP, Velthuizen RP, Silbiger MS, Bezdek JC (1992) A comparison of neural network and fuzzy clustering techniques in segmenting magnetic resonance images of the brain. IEEE Trans Neural Netw 3(5):672–682PubMedCrossRef Hall LO, Bensaid AM, Clarke LP, Velthuizen RP, Silbiger MS, Bezdek JC (1992) A comparison of neural network and fuzzy clustering techniques in segmenting magnetic resonance images of the brain. IEEE Trans Neural Netw 3(5):672–682PubMedCrossRef
29.
go back to reference Frangi AF, Niessen WJ, Vincken KL, Viergever MA (1998) Multiscale vessel enhancement filtering. In: Medical image computing and computer-assisted interventation-MICCAI’98. Springer, pp 130–137 Frangi AF, Niessen WJ, Vincken KL, Viergever MA (1998) Multiscale vessel enhancement filtering. In: Medical image computing and computer-assisted interventation-MICCAI’98. Springer, pp 130–137
31.
go back to reference Levoy M (1990) Efficient ray tracing of volume data. ACM Trans Graph (TOG) 9(3):245–261CrossRef Levoy M (1990) Efficient ray tracing of volume data. ACM Trans Graph (TOG) 9(3):245–261CrossRef
32.
go back to reference Marks MP, Pelc NJ, Ross MR, Enzmann DR (1992) Determination of cerebral blood flow with a phase-contrast cine MR imaging technique: evaluation of normal subjects and patients with arteriovenous malformations. Radiology 182(2):467–476 Marks MP, Pelc NJ, Ross MR, Enzmann DR (1992) Determination of cerebral blood flow with a phase-contrast cine MR imaging technique: evaluation of normal subjects and patients with arteriovenous malformations. Radiology 182(2):467–476
34.
go back to reference Axel L (1984) Blood flow effects in magnetic resonance imaging. Am J Roentgenol 143(6):1157–1166CrossRef Axel L (1984) Blood flow effects in magnetic resonance imaging. Am J Roentgenol 143(6):1157–1166CrossRef
35.
go back to reference Xiao C, Staring M, Shamonin D, Reiber JHC, Stolk J, Stoel BC (2011) A strain energy filter for 3D vessel enhancement with application to pulmonary CT images. Med Image anal 15(1):112–124PubMedCrossRef Xiao C, Staring M, Shamonin D, Reiber JHC, Stolk J, Stoel BC (2011) A strain energy filter for 3D vessel enhancement with application to pulmonary CT images. Med Image anal 15(1):112–124PubMedCrossRef
Metadata
Title
Cerebrovascular segmentation and planning of depth electrode insertion for epilepsy surgery
Authors
Xiaofei Du
Hui Ding
Wenjing Zhou
Guangming Zhang
Guangzhi Wang
Publication date
01-11-2013
Publisher
Springer Berlin Heidelberg
Published in
International Journal of Computer Assisted Radiology and Surgery / Issue 6/2013
Print ISSN: 1861-6410
Electronic ISSN: 1861-6429
DOI
https://doi.org/10.1007/s11548-013-0843-5

Other articles of this Issue 6/2013

International Journal of Computer Assisted Radiology and Surgery 6/2013 Go to the issue