Skip to main content
Top

11-04-2024 | Cataract | Cataract

Efficacy and safety of the implantation of a single-piece angulated foldable IOL in the sulcus

Authors: Gauthier Blanckaert, Joachim Van Calster, Joyce Jansen, Joris Vander Mijnsbrugge, Ann-Laure Delbecq, Ivo De Clerck, Jean-François Fils, Peter Stalmans

Published in: Graefe's Archive for Clinical and Experimental Ophthalmology

Login to get access

Abstract

Purpose

To study the visual results and tolerance of a Zeiss CT Lucia 601P intraocular lens (IOL) implanted in the sulcus after complicated cataract surgery or during IOL exchange for clouded IOL.

Methods

In total, 64 patients who underwent sulcus implantation were recalled to the hospital to undergo subjective and objective refraction, best corrected visual acuity measurement, tonometry, optical coherence tomography, laser flare photometry, biometry, and wavefront aberrometry.

Results

In spite of a large variation in preoperative refraction, the target refraction was obtained within 1.5 diopters in approximately 97% of patients and within 0.5 diopter in 53% of patients. Average BCVA was high (Snellen 0.86) and related to concomitant (mostly retinal) pathologies in eyes with poorer visual performance. Wavefront aberrometry showed no evidence of IOL tilting or decentration after long-term implantation in the sulcus. Tonometry was not different from the fellow eye of the patient (p > 0.5). In 53 patients with bilateral pseudophakia, the laser flare photometry was not significantly different from the fellow eye (p < 0.05).

Conclusion

This study demonstrates that this single-piece angulated foldable acrylic IOL can be considered for implantation in the sulcus. The visual results are favorable, and the IOL can be well-positioned and tolerated in the sulcus. Moreover, there were no safety issues found since there was no evidence of elevated IOP or chronic uveitis.
Literature
8.
go back to reference Henderson BA, SpringerLink (2016) Manual small incision cataract surgery. Springer International Publishing, Springer, Cham (Imprint)CrossRef Henderson BA, SpringerLink (2016) Manual small incision cataract surgery. Springer International Publishing, Springer, Cham (Imprint)CrossRef
Metadata
Title
Efficacy and safety of the implantation of a single-piece angulated foldable IOL in the sulcus
Authors
Gauthier Blanckaert
Joachim Van Calster
Joyce Jansen
Joris Vander Mijnsbrugge
Ann-Laure Delbecq
Ivo De Clerck
Jean-François Fils
Peter Stalmans
Publication date
11-04-2024
Publisher
Springer Berlin Heidelberg
Keyword
Cataract
Published in
Graefe's Archive for Clinical and Experimental Ophthalmology
Print ISSN: 0721-832X
Electronic ISSN: 1435-702X
DOI
https://doi.org/10.1007/s00417-024-06459-0