Abstract

Magnetic resonance imaging (MRI) within FDA guidelines for the MRI-conditional pacemaker precludes placing the heart at the center of the magnet’s bore. This in effect appears to preclude cardiovascular MR. In this manuscript, we describe a protocol for cardiovascular MR of patients with a Revo pacemaker system while operating within FDA guidelines, and the first US case of cardiovascular MR in a patient with a Revo MRI-conditional pacing system despite position constraints.
Appendix
Available only for authorised users
Literature
1.
go back to reference Kalin R, Stanton MS: Current clinical issues for MRI scanning of pacemaker and defibrillator patients. Pacing Clin Electrophysiol. 2005, 28: 326-328. 10.1111/j.1540-8159.2005.50024.x.CrossRefPubMed Kalin R, Stanton MS: Current clinical issues for MRI scanning of pacemaker and defibrillator patients. Pacing Clin Electrophysiol. 2005, 28: 326-328. 10.1111/j.1540-8159.2005.50024.x.CrossRefPubMed
2.
go back to reference Sommer T, Naehle CP, Yang A, et al: Strategy for Safe Performance of Extrathoracic Magnetic Resonance Imaging at 1.5 Tesla in the Presence of Cardiac Pacemakers in Non–Pacemaker-Dependent Patients. Circulation. 2006, 114: 1285-1292. 10.1161/CIRCULATIONAHA.105.597013.CrossRefPubMed Sommer T, Naehle CP, Yang A, et al: Strategy for Safe Performance of Extrathoracic Magnetic Resonance Imaging at 1.5 Tesla in the Presence of Cardiac Pacemakers in Non–Pacemaker-Dependent Patients. Circulation. 2006, 114: 1285-1292. 10.1161/CIRCULATIONAHA.105.597013.CrossRefPubMed
3.
go back to reference Reynolds MR, Zimetbaum P: Magnetic resonance imaging and cardiac devices: How safe is safe enough?. Ann Intern Med. 2011, 155: 470-472.CrossRefPubMed Reynolds MR, Zimetbaum P: Magnetic resonance imaging and cardiac devices: How safe is safe enough?. Ann Intern Med. 2011, 155: 470-472.CrossRefPubMed
4.
go back to reference Wilkoff BL, Bello D, Taborsky M, et al: Magnetic resonance imaging in patients with a pacemaker system designed for the magnetic resonance environment. Heart Rhythm. 2011, 8: 65-73. 10.1016/j.hrthm.2010.10.002.CrossRefPubMed Wilkoff BL, Bello D, Taborsky M, et al: Magnetic resonance imaging in patients with a pacemaker system designed for the magnetic resonance environment. Heart Rhythm. 2011, 8: 65-73. 10.1016/j.hrthm.2010.10.002.CrossRefPubMed
5.
go back to reference Nazarian S, Hansford R, Roguin A, et al: A prospective evaluation of a protocol for magnetic resonance imaging of patients with implanted cardiac devices. Ann Intern Med. 2011, 155: 415-424.PubMedCentralCrossRefPubMed Nazarian S, Hansford R, Roguin A, et al: A prospective evaluation of a protocol for magnetic resonance imaging of patients with implanted cardiac devices. Ann Intern Med. 2011, 155: 415-424.PubMedCentralCrossRefPubMed
6.
go back to reference Wang T, Klein JL, Woodard PK, et al: Plasmacytoma-Like Post-Transplant Lymphoproliferative Disease Occurring in a Cardiac Allograft: A Case Report and Review of Literature. J Clin Oncol. 2012, 30 (27): e278-e282. 10.1200/JCO.2011.39.5855.CrossRefPubMed Wang T, Klein JL, Woodard PK, et al: Plasmacytoma-Like Post-Transplant Lymphoproliferative Disease Occurring in a Cardiac Allograft: A Case Report and Review of Literature. J Clin Oncol. 2012, 30 (27): e278-e282. 10.1200/JCO.2011.39.5855.CrossRefPubMed
7.
go back to reference Quarta G, Holdright DR, Plant GT, et al: Cardiovascular magnetic resonance in cardiac sarcoidosis with MR conditional pacemaker in situ. J Cardiovasc Magn Reson. 2011, 13: 26-10.1186/1532-429X-13-26.PubMedCentralCrossRefPubMed Quarta G, Holdright DR, Plant GT, et al: Cardiovascular magnetic resonance in cardiac sarcoidosis with MR conditional pacemaker in situ. J Cardiovasc Magn Reson. 2011, 13: 26-10.1186/1532-429X-13-26.PubMedCentralCrossRefPubMed
Metadata
Title
Cardiovascular magnetic resonance with an MR compatible pacemaker
Authors
Anita R Bhandiwad
Kristopher W Cummings
Michael Crowley
Pamela K Woodard
Publication date
01-12-2013
Publisher
BioMed Central
Published in
Journal of Cardiovascular Magnetic Resonance / Issue 1/2013
Electronic ISSN: 1532-429X
DOI
https://doi.org/10.1186/1532-429X-15-18

Other articles of this Issue 1/2013

Journal of Cardiovascular Magnetic Resonance 1/2013 Go to the issue