Published in: European Radiology 4/2008

01-04-2008 | Cardiac

Cardiac T2* and lipid measurement at 3.0 T-initial experience

Authors: Declan P. O’Regan, Martina F. Callaghan, Julie Fitzpatrick, Rossi P. Naoumova, Joseph V. Hajnal, Stephan A. Schmitz

Published in: European Radiology | Issue 4/2008

Login to get access

Abstract

This study was designed to assess whether breath-hold cardiac multiecho imaging at 3.0 T is achievable without significant image artefacts and if fat/water phase interference modulates the exponential T2* signal decay. Twelve healthy volunteers (mean age 39) were imaged on a Philips Intera 3.0 T MRI scanner. Multiecho imaging was performed with a breath-hold spoiled gradient echo sequence with a seven echo readout (echo times 1.15–8.05 ms, repetition time 11 ms) using a black-blood prepulse and volume shimming. T2* values were calculated with both mono- and biexpoential fits from the mean signal intensity of the interventricular septum. The global mean T2* was 27.3 ms ± 6.4. The mean signal-to-noise ratio (SNR) of the septum was 22.8 ± 9.9, and the contrast-to-noise ratio (CNR) of the septum to the left ventricular cavity 20.3 ± 9.4. A better fit was obtained with a biexponential model and the mean fat fraction derived was 3.7%. Cardiac functional parameters were in the normal range and showed no correlation with T2*. Cardiac T2* estimation with gradient multiecho imaging at 3.0 T can be achieved with minimal artefact and modelling the signal decay with a biexponential function allows estimation of myocardial lipid content as well as T2* decay.
Literature
1.
go back to reference Olivieri NF, Nathan DG, MacMillan JH et al (1994) Survival in medically treated patients with homozygous beta-thalassemia. N Engl J Med 331(9):574–578PubMedCrossRef Olivieri NF, Nathan DG, MacMillan JH et al (1994) Survival in medically treated patients with homozygous beta-thalassemia. N Engl J Med 331(9):574–578PubMedCrossRef
2.
go back to reference Zurlo MG, De Stefano P, Borgna-Pignatti C et al (1989) Survival and causes of death in thalassaemia major. Lancet 2(8653):27–30PubMedCrossRef Zurlo MG, De Stefano P, Borgna-Pignatti C et al (1989) Survival and causes of death in thalassaemia major. Lancet 2(8653):27–30PubMedCrossRef
3.
go back to reference Mavrogeni SI, Markussis V, Kaklamanis L et al (2005) A comparison of magnetic resonance imaging and cardiac biopsy in the evaluation of heart iron overload in patients with beta-thalassemia major. Eur J Haematol 75(3):241–247PubMedCrossRef Mavrogeni SI, Markussis V, Kaklamanis L et al (2005) A comparison of magnetic resonance imaging and cardiac biopsy in the evaluation of heart iron overload in patients with beta-thalassemia major. Eur J Haematol 75(3):241–247PubMedCrossRef
4.
go back to reference Stark D (1991) Hepatic iron overload: paramagnetic pathology. Radiology 179(2):333–335PubMed Stark D (1991) Hepatic iron overload: paramagnetic pathology. Radiology 179(2):333–335PubMed
5.
go back to reference Anderson LJ, Holden S, Davis B et al (2001) Cardiovascular T2-star (T2*) magnetic resonance for the early diagnosis of myocardial iron overload. Eur Heart J 22(23):2171–2179PubMedCrossRef Anderson LJ, Holden S, Davis B et al (2001) Cardiovascular T2-star (T2*) magnetic resonance for the early diagnosis of myocardial iron overload. Eur Heart J 22(23):2171–2179PubMedCrossRef
6.
go back to reference Westwood MA, Anderson LJ, Firmin DN et al (2003) Interscanner reproducibility of cardiovascular magnetic resonance T2* measurements of tissue iron in thalassemia. J Magn Reson Imaging 18(5):616–620PubMedCrossRef Westwood MA, Anderson LJ, Firmin DN et al (2003) Interscanner reproducibility of cardiovascular magnetic resonance T2* measurements of tissue iron in thalassemia. J Magn Reson Imaging 18(5):616–620PubMedCrossRef
7.
go back to reference Westwood MA, Sheppard MN, Awogbade M et al (2005) Myocardial biopsy and T2* magnetic resonance in heart failure due to thalassaemia. Br J Haematol 128(1):2PubMedCrossRef Westwood MA, Sheppard MN, Awogbade M et al (2005) Myocardial biopsy and T2* magnetic resonance in heart failure due to thalassaemia. Br J Haematol 128(1):2PubMedCrossRef
8.
go back to reference Anderson LJ, Westwood MA, Holden S et al (2004) Myocardial iron clearance during reversal of siderotic cardiomyopathy with intravenous desferrioxamine: a prospective study using T2* cardiovascular magnetic resonance. Br J Haematol 127(3):348–355PubMedCrossRef Anderson LJ, Westwood MA, Holden S et al (2004) Myocardial iron clearance during reversal of siderotic cardiomyopathy with intravenous desferrioxamine: a prospective study using T2* cardiovascular magnetic resonance. Br J Haematol 127(3):348–355PubMedCrossRef
9.
go back to reference Pepe A, Lombardi M, Positano V et al (2006) Evaluation of the efficacy of oral deferiprone in beta-thalassemia major by multislice multiecho T2*. Eur J Haematol 76(3):183–192PubMedCrossRef Pepe A, Lombardi M, Positano V et al (2006) Evaluation of the efficacy of oral deferiprone in beta-thalassemia major by multislice multiecho T2*. Eur J Haematol 76(3):183–192PubMedCrossRef
10.
go back to reference Christoforidis A, Haritandi A, Tsatra I et al (2007) Four-year evaluation of myocardial and liver iron assessed prospectively with serial MRI scans in young patients with beta-thalassaemia major: comparison between different chelation regimens. Eur J Haematol 78(1):52–57PubMedCrossRef Christoforidis A, Haritandi A, Tsatra I et al (2007) Four-year evaluation of myocardial and liver iron assessed prospectively with serial MRI scans in young patients with beta-thalassaemia major: comparison between different chelation regimens. Eur J Haematol 78(1):52–57PubMedCrossRef
11.
go back to reference Derby K, Kramer DM, Kaufman L (1993) A technique for assessment of bone marrow composition using magnetic resonance phase interference at low field. Magn Reson Med 29(4):465–469PubMedCrossRef Derby K, Kramer DM, Kaufman L (1993) A technique for assessment of bone marrow composition using magnetic resonance phase interference at low field. Magn Reson Med 29(4):465–469PubMedCrossRef
12.
go back to reference Storey P, Thompson AA, Carqueville CL et al (2007) R2* imaging of transfusional iron burden at 3 T and comparison with 1.5T. J Magn Reson Imaging 25(3):540–547PubMedCrossRef Storey P, Thompson AA, Carqueville CL et al (2007) R2* imaging of transfusional iron burden at 3 T and comparison with 1.5T. J Magn Reson Imaging 25(3):540–547PubMedCrossRef
13.
go back to reference Szczepaniak LS, Babcock EE, Schick F et al (1999) Measurement of intracellular triglyceride stores by H spectroscopy: validation in vivo. Am J Physiol Endocrinol Metab 276(5):E977–E989 Szczepaniak LS, Babcock EE, Schick F et al (1999) Measurement of intracellular triglyceride stores by H spectroscopy: validation in vivo. Am J Physiol Endocrinol Metab 276(5):E977–E989
14.
go back to reference Alfakih K, Plein S, Thiele H et al (2003) Normal human left and right ventricular dimensions for MRI as assessed by turbo gradient echo and steady-state free precession imaging sequences. J Magn Reson Imaging 17(3):323–329PubMedCrossRef Alfakih K, Plein S, Thiele H et al (2003) Normal human left and right ventricular dimensions for MRI as assessed by turbo gradient echo and steady-state free precession imaging sequences. J Magn Reson Imaging 17(3):323–329PubMedCrossRef
15.
go back to reference Ghugre NR, Enriquez CM, Coates TD, Nelson MD Jr, Wood JC (2006) Improved R2* measurements in myocardial iron overload. J Magn Reson Imaging 23(1):9–16PubMedCrossRef Ghugre NR, Enriquez CM, Coates TD, Nelson MD Jr, Wood JC (2006) Improved R2* measurements in myocardial iron overload. J Magn Reson Imaging 23(1):9–16PubMedCrossRef
16.
go back to reference Marquardt DW (1963) An Algorithm for Least Squares Estimation of Parameters. J Soc Ind Appl Math 11:431–441CrossRef Marquardt DW (1963) An Algorithm for Least Squares Estimation of Parameters. J Soc Ind Appl Math 11:431–441CrossRef
17.
go back to reference Kaufman L, Kramer DM, Crooks LE, Ortendahl DA (1989) Measuring signal-to-noise ratios in MR imaging. Radiology 173(1):265–267PubMed Kaufman L, Kramer DM, Crooks LE, Ortendahl DA (1989) Measuring signal-to-noise ratios in MR imaging. Radiology 173(1):265–267PubMed
18.
go back to reference Bartzokis G, Aravagiri M, Oldendorf WH, Mintz J, Marder SR (1993) Field dependent transverse relaxation rate increase may be a specific measure of tissue iron stores. Magn Reson Med 29(4):459–464PubMedCrossRef Bartzokis G, Aravagiri M, Oldendorf WH, Mintz J, Marder SR (1993) Field dependent transverse relaxation rate increase may be a specific measure of tissue iron stores. Magn Reson Med 29(4):459–464PubMedCrossRef
19.
go back to reference Vymazal J, Brooks RA, Zak O et al (1992) T1 and T2 of ferritin at different field strengths: effect on MRI. Magn Reson Med 27(2):368–374PubMedCrossRef Vymazal J, Brooks RA, Zak O et al (1992) T1 and T2 of ferritin at different field strengths: effect on MRI. Magn Reson Med 27(2):368–374PubMedCrossRef
20.
go back to reference de Bazelaire CMJ, Duhamel GD, Rofsky NM, Alsop DC (2004) MR imaging relaxation times of abdominal and pelvic tissues measured in vivo at 3.0 T: Preliminary results. Radiology 230(3):652–659PubMedCrossRef de Bazelaire CMJ, Duhamel GD, Rofsky NM, Alsop DC (2004) MR imaging relaxation times of abdominal and pelvic tissues measured in vivo at 3.0 T: Preliminary results. Radiology 230(3):652–659PubMedCrossRef
21.
go back to reference Westwood M, Anderson LJ, Firmin DN et al (2003) A single breath-hold multiecho T2* cardiovascular magnetic resonance technique for diagnosis of myocardial iron overload. J Magn Reson Imaging 18(1):33–39PubMedCrossRef Westwood M, Anderson LJ, Firmin DN et al (2003) A single breath-hold multiecho T2* cardiovascular magnetic resonance technique for diagnosis of myocardial iron overload. J Magn Reson Imaging 18(1):33–39PubMedCrossRef
22.
go back to reference McGavock JM, Lingvay I, Zib I et al (2007) Cardiac steatosis in diabetes mellitus. A 1H-magnetic resonance spectroscopy study. Circulation 116(10):1170–1175PubMedCrossRef McGavock JM, Lingvay I, Zib I et al (2007) Cardiac steatosis in diabetes mellitus. A 1H-magnetic resonance spectroscopy study. Circulation 116(10):1170–1175PubMedCrossRef
23.
go back to reference Sharma S, Adrogue JV, Golfman L et al (2004) Intramyocardial lipid accumulation in the failing human heart resembles the lipotoxic rat heart. Faseb J 18(14):1692–1700PubMedCrossRef Sharma S, Adrogue JV, Golfman L et al (2004) Intramyocardial lipid accumulation in the failing human heart resembles the lipotoxic rat heart. Faseb J 18(14):1692–1700PubMedCrossRef
24.
go back to reference Hinton DP, Wald LL, Pitts J, Schmitt F (2003) Comparison of cardiac MRI on 1.5 and 3.0 Tesla clinical whole body systems. Invest Radiol 38(7):436–442PubMedCrossRef Hinton DP, Wald LL, Pitts J, Schmitt F (2003) Comparison of cardiac MRI on 1.5 and 3.0 Tesla clinical whole body systems. Invest Radiol 38(7):436–442PubMedCrossRef
25.
go back to reference Gutberlet M, Spors B, Grothoff M et al (2004) Comparison of different cardiac MRI sequences at 1.5 T/3.0 T with respect to signal-to-noise and contrast-to-noise ratios-initial experience. Rofo 176(6):801–808PubMed Gutberlet M, Spors B, Grothoff M et al (2004) Comparison of different cardiac MRI sequences at 1.5 T/3.0 T with respect to signal-to-noise and contrast-to-noise ratios-initial experience. Rofo 176(6):801–808PubMed
26.
go back to reference Schar M, Kozerke S, Fischer SE, Boesiger P (2004) Cardiac SSFP imaging at 3 Tesla. Magn Reson Med 51(4):799–806PubMedCrossRef Schar M, Kozerke S, Fischer SE, Boesiger P (2004) Cardiac SSFP imaging at 3 Tesla. Magn Reson Med 51(4):799–806PubMedCrossRef
27.
go back to reference Reeder SB, Faranesh AZ, Boxerman JL, McVeigh ER (1998) In vivo measurement of T*2 and field inhomogeneity maps in the human heart at 1.5 T. Magn Reson Med 39(6):988–998PubMedCrossRef Reeder SB, Faranesh AZ, Boxerman JL, McVeigh ER (1998) In vivo measurement of T*2 and field inhomogeneity maps in the human heart at 1.5 T. Magn Reson Med 39(6):988–998PubMedCrossRef
28.
go back to reference Gudbjartsson H, Patz S (1995) The Rician distribution of noisy MRI data. Magn Reson Med 34(6):910–914PubMedCrossRef Gudbjartsson H, Patz S (1995) The Rician distribution of noisy MRI data. Magn Reson Med 34(6):910–914PubMedCrossRef
29.
go back to reference Pijl MEJ, Doornbos J, Wasser MNJM et al (2004) Quantitative analysis of focal masses at MR imaging: A plea for standardization. Radiology 231(3):737–744PubMedCrossRef Pijl MEJ, Doornbos J, Wasser MNJM et al (2004) Quantitative analysis of focal masses at MR imaging: A plea for standardization. Radiology 231(3):737–744PubMedCrossRef
30.
go back to reference Kellman P, McVeigh ER (2005) Image reconstruction in SNR units: a general method for SNR measurement. Magn Reson Med 54(6):1439–1447PubMedCrossRef Kellman P, McVeigh ER (2005) Image reconstruction in SNR units: a general method for SNR measurement. Magn Reson Med 54(6):1439–1447PubMedCrossRef
31.
go back to reference Positano V, Pepe A, Santarelli MF et al (2007) Standardized T(2)* map of normal human heart in vivo to correct T(2)* segmental artefacts. NMR Biomed 20(6):578–590PubMedCrossRef Positano V, Pepe A, Santarelli MF et al (2007) Standardized T(2)* map of normal human heart in vivo to correct T(2)* segmental artefacts. NMR Biomed 20(6):578–590PubMedCrossRef
Metadata
Title
Cardiac T2* and lipid measurement at 3.0 T-initial experience
Authors
Declan P. O’Regan
Martina F. Callaghan
Julie Fitzpatrick
Rossi P. Naoumova
Joseph V. Hajnal
Stephan A. Schmitz
Publication date
01-04-2008
Publisher
Springer-Verlag
Published in
European Radiology / Issue 4/2008
Print ISSN: 0938-7994
Electronic ISSN: 1432-1084
DOI
https://doi.org/10.1007/s00330-007-0814-8

Other articles of this Issue 4/2008

European Radiology 4/2008 Go to the issue