Skip to main content
Top
Published in: Journal of Medical Case Reports 1/2009

Open Access 01-12-2009 | Case report

Cardiac embolization of an implanted fiducial marker for hepatic stereotactic body radiotherapy: a case report

Authors: Hooman Hennessey, David Valenti, Tatiana Cabrera, Valerie Panet-Raymond, David Roberge

Published in: Journal of Medical Case Reports | Issue 1/2009

Login to get access

Abstract

Introduction

In liver stereotactic body radiotherapy, reduction of normal tissue irradiation requires daily image guidance. This is typically accomplished by imaging a surrogate to the tumor. The surrogate is often an implanted metal fiducial marker. There are few reports addressing the specific risks of hepatic fiducial marker implantation. These risks are assumed to be similar to percutaneous liver biopsies which are associated with a 1-4% complication rate - almost always pain or bleeding. To the best of our knowledge, we present the first case of such a fiducial marker migrating to the heart.

Case presentation

An 81-year-old Caucasian man (5 years post-gastrectomy for a gastric adenocarcinoma) was referred post-second line palliative chemotherapy for radiotherapy of an isolated liver metastasis. It was decided to proceed with treatment and platinum fiducials were chosen for radiation targeting. Under local anesthesia, three Nester embolization coils (Cook Medical Inc., Bloomington, IN, USA) were implanted under computed tomography guidance. Before the placement of each coil, the location of the tip of the delivery needle was confirmed by computed tomography imaging. During the procedure, the third coil unexpectedly migrated through the hepatic vein to the inferior vena cava and lodged at the junction of the vena cava and the right atrium. The patient remained asymptomatic. He was immediately referred to angiography for extraction of the coil. Using fluoroscopic guidance, an EN Snare Retrieval System (Hatch Medical L.L.C., Snellville, GA, USA) was introduced through a jugular catheter; it successfully grasped the coil and the coil was removed. The patient was kept overnight for observation and no immediate or delayed complications were encountered due to the migration or retrieval of the coil. He subsequently went on to be treated using the remaining fiducials.

Conclusion

Implanted fiducial markers are increasingly used for stereotactic radiotherapy. There is sparse literature on the risks of such procedures. Although uncommon, the risk of migration does exist and therefore physicians (surgeons, oncologists and radiologists) and patients should be aware of this possibility.
Appendix
Available only for authorised users
Literature
1.
go back to reference Lax I, Blomgren H, Naslund I, Svanstrom R: Stereotactic radiotherapy of malignancies in the abdomen. Methodological aspects. Acta Oncol. 1994, 33: 677-683. 10.3109/02841869409121782.CrossRefPubMed Lax I, Blomgren H, Naslund I, Svanstrom R: Stereotactic radiotherapy of malignancies in the abdomen. Methodological aspects. Acta Oncol. 1994, 33: 677-683. 10.3109/02841869409121782.CrossRefPubMed
2.
go back to reference Timmerman RD, Kavanagh BD, Cho LC, Papiez L, Xing L: Stereotactic body radiation therapy in multiple organ sites. J Clin Oncol. 2007, 25: 947-952. 10.1200/JCO.2006.09.7469.CrossRefPubMed Timmerman RD, Kavanagh BD, Cho LC, Papiez L, Xing L: Stereotactic body radiation therapy in multiple organ sites. J Clin Oncol. 2007, 25: 947-952. 10.1200/JCO.2006.09.7469.CrossRefPubMed
3.
go back to reference Teh BS, Paulino AC, Lu HH, Chiu JK, Richardson S, Chiang S, Amato R, Butler EB, Bloch C: Versatility of the Novalis system to deliver image-guided stereotactic body radiation therapy (SBRT) for various anatomical sites. Technol Cancer Res Treat. 2007, 6: 347-354.CrossRefPubMed Teh BS, Paulino AC, Lu HH, Chiu JK, Richardson S, Chiang S, Amato R, Butler EB, Bloch C: Versatility of the Novalis system to deliver image-guided stereotactic body radiation therapy (SBRT) for various anatomical sites. Technol Cancer Res Treat. 2007, 6: 347-354.CrossRefPubMed
4.
go back to reference Roberge D, Ruo R, Parker W, Patroccinio H, Valenti D: Use of platinum embolization coils for targeting liver lesions in stereotactic body radiotherapy/radiosurgery. Radiosurgery 8th International Steretactic Radiosurgery Society Meeting, San Francisco, June 2007. Edited by: McDermott M. 2009, Basel, Karger, Roberge D, Ruo R, Parker W, Patroccinio H, Valenti D: Use of platinum embolization coils for targeting liver lesions in stereotactic body radiotherapy/radiosurgery. Radiosurgery 8th International Steretactic Radiosurgery Society Meeting, San Francisco, June 2007. Edited by: McDermott M. 2009, Basel, Karger,
5.
go back to reference Langenhuijsen JF, van Lin EN, Kiemeney LA, Vight van der LP, McColl GM, Visser AG, Witjes JA: Ultrasound-guided transrectal implantation of gold markers for prostate localization during external beam radiotherapy: complication rate and risk factors. Int J Radiat Oncol Biol Phys. 2007, 69: 671-676.CrossRefPubMed Langenhuijsen JF, van Lin EN, Kiemeney LA, Vight van der LP, McColl GM, Visser AG, Witjes JA: Ultrasound-guided transrectal implantation of gold markers for prostate localization during external beam radiotherapy: complication rate and risk factors. Int J Radiat Oncol Biol Phys. 2007, 69: 671-676.CrossRefPubMed
6.
go back to reference Shirato H, Harada T, Harabayashi T, Hida K, Endo H, Kitamura K, Onimaru R, Yamazaki K, Kurauchi N, Shimizu T, Shinohara N, Matsushita M, Dosaka-Akita H, Miyasaka K: Feasibility of insertion/implantation of 2.0-mm-diameter gold internal fiducial markers for precise setup and real-time tumor tracking in radiotherapy. Int J Radiat Oncol Biol Phys. 2003, 56: 240-247.CrossRefPubMed Shirato H, Harada T, Harabayashi T, Hida K, Endo H, Kitamura K, Onimaru R, Yamazaki K, Kurauchi N, Shimizu T, Shinohara N, Matsushita M, Dosaka-Akita H, Miyasaka K: Feasibility of insertion/implantation of 2.0-mm-diameter gold internal fiducial markers for precise setup and real-time tumor tracking in radiotherapy. Int J Radiat Oncol Biol Phys. 2003, 56: 240-247.CrossRefPubMed
7.
go back to reference Kothary N, Heit JJ, Louie JD, Kuo WT, Loo BW, Koong A, Chang DT, Hovsepian D, Sze DY, Hofmann LV: Safety and efficacy of percutaneous fiducial marker implantation for image-guided radiation therapy. J Vasc Interv Radiol. 2009, 20: 235-239. 10.1016/j.jvir.2008.09.026.CrossRefPubMed Kothary N, Heit JJ, Louie JD, Kuo WT, Loo BW, Koong A, Chang DT, Hovsepian D, Sze DY, Hofmann LV: Safety and efficacy of percutaneous fiducial marker implantation for image-guided radiation therapy. J Vasc Interv Radiol. 2009, 20: 235-239. 10.1016/j.jvir.2008.09.026.CrossRefPubMed
8.
go back to reference Pawa S, Ehrinpreis M, Mutchnick M, Janisse J, Dhar R, Siddiqui FA: Percutaneous liver biopsy is safe in chronic hepatitis C patients with end-stage renal disease. Clin Gastroenterol Hepatol. 2007, 5: 1316-1320. 10.1016/j.cgh.2007.07.010.CrossRefPubMed Pawa S, Ehrinpreis M, Mutchnick M, Janisse J, Dhar R, Siddiqui FA: Percutaneous liver biopsy is safe in chronic hepatitis C patients with end-stage renal disease. Clin Gastroenterol Hepatol. 2007, 5: 1316-1320. 10.1016/j.cgh.2007.07.010.CrossRefPubMed
9.
go back to reference Kitamura KS, Shimizu S, Shinohara N, Harabayashi T, Shimizu T, Kodama Y, Endo H, Onimaru R, Nishioka S, Aoyama H, Tsuchiya K, Miyasaka K: Registration accuracy and possible migration of internal fiducial gold marker implanted in prostate and liver treated with real-time tumor-tracking radiation therapy (RTRT). Radiother Oncol. 2002, 62: 275-281. 10.1016/S0167-8140(02)00017-8.CrossRefPubMed Kitamura KS, Shimizu S, Shinohara N, Harabayashi T, Shimizu T, Kodama Y, Endo H, Onimaru R, Nishioka S, Aoyama H, Tsuchiya K, Miyasaka K: Registration accuracy and possible migration of internal fiducial gold marker implanted in prostate and liver treated with real-time tumor-tracking radiation therapy (RTRT). Radiother Oncol. 2002, 62: 275-281. 10.1016/S0167-8140(02)00017-8.CrossRefPubMed
10.
go back to reference Sommerkamp H, Rupprecht M, Wannenmacher M: Seed loss in interstitial radiotherapy of prostatic carcinoma with I-125. Int J Radiat Oncol Biol Phys. 1988, 14: 389-392.CrossRefPubMed Sommerkamp H, Rupprecht M, Wannenmacher M: Seed loss in interstitial radiotherapy of prostatic carcinoma with I-125. Int J Radiat Oncol Biol Phys. 1988, 14: 389-392.CrossRefPubMed
11.
go back to reference Zhu AX, Wallner KE, Frivold GP, Ferry D, Jutzy KR, Foster GP: Prostate brachytherapy seed migration to the right coronary artery associated with an acute myocardial infarction. Brachytherapy. 2006, 5: 262-265. 10.1016/j.brachy.2006.08.004.CrossRefPubMed Zhu AX, Wallner KE, Frivold GP, Ferry D, Jutzy KR, Foster GP: Prostate brachytherapy seed migration to the right coronary artery associated with an acute myocardial infarction. Brachytherapy. 2006, 5: 262-265. 10.1016/j.brachy.2006.08.004.CrossRefPubMed
12.
go back to reference Ozhasoglu CS, Chen H, Burton S, Komanduri K, Yue NJ, Huq SM, Heron DE: Synchrony - cyberknife respiratory compensation technology. Med Dosim. 2008, 33: 117-123. 10.1016/j.meddos.2008.02.004.CrossRefPubMed Ozhasoglu CS, Chen H, Burton S, Komanduri K, Yue NJ, Huq SM, Heron DE: Synchrony - cyberknife respiratory compensation technology. Med Dosim. 2008, 33: 117-123. 10.1016/j.meddos.2008.02.004.CrossRefPubMed
13.
go back to reference Prevost JB, Nuyttens JJ, Hoogeman MS, Poll JJ, van Dijk LC, Pattynama PM: Endovascular coils as lung tumour markers in real-time tumour tracking stereotactic radiotherapy: preliminary results. Eur Radiol. 2008, 18: 1569-1576. 10.1007/s00330-008-0933-x.CrossRefPubMedPubMedCentral Prevost JB, Nuyttens JJ, Hoogeman MS, Poll JJ, van Dijk LC, Pattynama PM: Endovascular coils as lung tumour markers in real-time tumour tracking stereotactic radiotherapy: preliminary results. Eur Radiol. 2008, 18: 1569-1576. 10.1007/s00330-008-0933-x.CrossRefPubMedPubMedCentral
Metadata
Title
Cardiac embolization of an implanted fiducial marker for hepatic stereotactic body radiotherapy: a case report
Authors
Hooman Hennessey
David Valenti
Tatiana Cabrera
Valerie Panet-Raymond
David Roberge
Publication date
01-12-2009
Publisher
BioMed Central
Published in
Journal of Medical Case Reports / Issue 1/2009
Electronic ISSN: 1752-1947
DOI
https://doi.org/10.1186/1752-1947-3-140

Other articles of this Issue 1/2009

Journal of Medical Case Reports 1/2009 Go to the issue