Skip to main content
Top
Published in: Archives of Orthopaedic and Trauma Surgery 1/2013

01-01-2013 | Trauma Surgery

Cannulated screw unraveling: a case series and literature-based review of an under-recognized complication

Authors: Eli Kupperman, Orrin Franko, Andrew Indresano, Paul Girard

Published in: Archives of Orthopaedic and Trauma Surgery | Issue 1/2013

Login to get access

Abstract

Partially threaded cannulated screws have enhanced the orthopedic surgeon’s ability to fix periarticular fractures. There are many reports of complications and hardware failure during screw removal, but those during fracture fixation are under-reported and under-recognized in the literature. We describe a 21-year-old healthy man with a grade 1 open displaced medial epicondylar humerus fracture. Upon fracture fixation in the OR using a partially threaded cannulated screw over a Kirschner wire, the threads of the screw unraveled. The operating surgeon felt increased resistance and the unraveling was demonstrated on intra-operative fluoroscopy. The screw was removed by hand without hardware retention and a new K-wire and cannulated screw were used for definitive fixation. We found seven previous cases reporting a similar complication with mixed presentations and results. All occurred in young healthy patients, six of which were males. Six of the seven cases made no mention of a tactile change in resistance during fixation and only one of the seven pre-drilled the cortex prior to placement of the cannulated screw. We believe that screw unraveling is an under-reported complication of fracture fixation with cannulated screws that should be recognized by the orthopedic community. We found intra-operative fluoroscopy integral to the recognition of the problem in our case and recommend its use in fracture fixation with cannulated screws. We also suggest pre-drilling of cortices, especially when operating on young patients with strong bone.
Literature
1.
go back to reference Moehring HD, Johnson PG (1994) The use of cannulated screws in musculoskeletal trauma. A review of surgical techniques. Orthop Rev. Suppl:10–21 Moehring HD, Johnson PG (1994) The use of cannulated screws in musculoskeletal trauma. A review of surgical techniques. Orthop Rev. Suppl:10–21
2.
go back to reference Schwend RK, Hennrikus WL, O’Brien TJ, Millis MB, Lynch MR (1997) Complications when using the cannulated 3.5 mm screw system. Orthopedics 20(3):221–223PubMed Schwend RK, Hennrikus WL, O’Brien TJ, Millis MB, Lynch MR (1997) Complications when using the cannulated 3.5 mm screw system. Orthopedics 20(3):221–223PubMed
3.
go back to reference Robb JE, Annan IH, Macnicol MF (2003) Guidewire damage during cannulated screw fixation for slipped capital femoral epiphysis. J Pediatr Orthop B 12(3):219–221PubMed Robb JE, Annan IH, Macnicol MF (2003) Guidewire damage during cannulated screw fixation for slipped capital femoral epiphysis. J Pediatr Orthop B 12(3):219–221PubMed
4.
go back to reference Brown CH, Cullen NC (1999) Disassembly of a small cannulated cancellous screw. Foot Ankle Int 20(7):468–469PubMed Brown CH, Cullen NC (1999) Disassembly of a small cannulated cancellous screw. Foot Ankle Int 20(7):468–469PubMed
5.
go back to reference Mooney JF III, Simmons TW (2003) A previously unreported complication of the AO cannulated 4.0- and 4.5-mm screw systems: a review of three cases. J South Orthop Assoc 12(3):160–162PubMed Mooney JF III, Simmons TW (2003) A previously unreported complication of the AO cannulated 4.0- and 4.5-mm screw systems: a review of three cases. J South Orthop Assoc 12(3):160–162PubMed
6.
go back to reference Levene AP, Templeton P (2008) Previously unreported failure of a Synthes 4.0 mm diameter cannulated screw. Injury Extra 39:212–215CrossRef Levene AP, Templeton P (2008) Previously unreported failure of a Synthes 4.0 mm diameter cannulated screw. Injury Extra 39:212–215CrossRef
7.
go back to reference Sabnis B, Brenkel I, Chesney D, Weir I (2009) Unusual mode of mechanical failure of an AO cannulated self drilling screw. A case report. Acta Orthop Belg 75(4):557–560PubMed Sabnis B, Brenkel I, Chesney D, Weir I (2009) Unusual mode of mechanical failure of an AO cannulated self drilling screw. A case report. Acta Orthop Belg 75(4):557–560PubMed
8.
go back to reference Chen A, Willis-Owen C, Akhtar K, Kamineni S (2010) Failure of asnis iii 5.0 mm cannulated screw: a case report. Cases J 7(3):9CrossRef Chen A, Willis-Owen C, Akhtar K, Kamineni S (2010) Failure of asnis iii 5.0 mm cannulated screw: a case report. Cases J 7(3):9CrossRef
Metadata
Title
Cannulated screw unraveling: a case series and literature-based review of an under-recognized complication
Authors
Eli Kupperman
Orrin Franko
Andrew Indresano
Paul Girard
Publication date
01-01-2013
Publisher
Springer-Verlag
Published in
Archives of Orthopaedic and Trauma Surgery / Issue 1/2013
Print ISSN: 0936-8051
Electronic ISSN: 1434-3916
DOI
https://doi.org/10.1007/s00402-012-1638-9

Other articles of this Issue 1/2013

Archives of Orthopaedic and Trauma Surgery 1/2013 Go to the issue