Published in: Intensive Care Medicine 6/2009

01-06-2009 | Editorial

Can we use pulse pressure variations to predict fluid responsiveness in patients with ARDS?

Authors: Jean-Yves Lefrant, Daniel De Backer

Published in: Intensive Care Medicine | Issue 6/2009

Login to get access

Excerpt

Respiratory variations in stroke volume have been shown to be associated with preload dependency in mechanically ventilated patients without spontaneous breathing movements. Pulse pressure variations (ΔPP), a surrogate of stroke volume variation (SVV), predict fluid responsiveness better than static indices of cardiac preload [1, 2]. However, SVVs and ΔPP are caused by respiratory-induced changes in preload that may be limited when patients are ventilated at low tidal volume. The reliability of ΔPP could hence be theoretically limited in mechanically ventilated patients with low tidal volume [3]. An experimental study showed that changes in SVV between hemorrhage and fluid loading were limited when tidal volume was 5 ml/kg in contrast with larger changes at 10 and 15 ml/kg [4]. In mechanically ventilated acute respiratory distress syndrome (ARDS) patients, De Backer et al. [5] reported that the predictive value of ΔPP for fluid responsiveness decreased when a tidal volume lower than 8 ml/kg was applied [area under the ROC (AUC ROC) = 0.71 ± 0.09]. A similar AUC ROC (0.768) was recently reported in 22 ARDS patients ventilated with tidal volume ranging from 5.3 to 8.3 ml/kg [6]. …
Literature
1.
go back to reference Michard F, Boussat S, Chemla D, Anguel N, Mercat A, Lecarpentier Y, Richard C, Pinsky MR, Teboul JL (2000) Relation between respiratory changes in arterial pulse pressure and fluid responsiveness in septic patients with acute circulatory failure. Am J Respir Crit Care Med 162:134–138PubMed Michard F, Boussat S, Chemla D, Anguel N, Mercat A, Lecarpentier Y, Richard C, Pinsky MR, Teboul JL (2000) Relation between respiratory changes in arterial pulse pressure and fluid responsiveness in septic patients with acute circulatory failure. Am J Respir Crit Care Med 162:134–138PubMed
2.
go back to reference Michard F, Teboul JL (2002) Predicting fluid responsiveness in ICU patients: a critical analysis of the evidence. Chest 121:2000–2008PubMedCrossRef Michard F, Teboul JL (2002) Predicting fluid responsiveness in ICU patients: a critical analysis of the evidence. Chest 121:2000–2008PubMedCrossRef
3.
go back to reference Michard F (2005) Changes in arterial pressure during mechanical ventilation. Anesthesiology 103:419–428; quiz 449–415PubMedCrossRef Michard F (2005) Changes in arterial pressure during mechanical ventilation. Anesthesiology 103:419–428; quiz 449–415PubMedCrossRef
4.
go back to reference Renner J, Cavus E, Meybohm P, Tonner P, Steinfath M, Scholz J, Lutter G, Bein B (2007) Stroke volume variation during hemorrhage and after fluid loading: impact of different tidal volumes. Acta Anaesthesiol Scand 51:538–544PubMedCrossRef Renner J, Cavus E, Meybohm P, Tonner P, Steinfath M, Scholz J, Lutter G, Bein B (2007) Stroke volume variation during hemorrhage and after fluid loading: impact of different tidal volumes. Acta Anaesthesiol Scand 51:538–544PubMedCrossRef
5.
go back to reference De Backer D, Heenen S, Piagnerelli M, Koch M, Vincent JL (2005) Pulse pressure variations to predict fluid responsiveness: influence of tidal volume. Intensive Care Med 31:517–523PubMedCrossRef De Backer D, Heenen S, Piagnerelli M, Koch M, Vincent JL (2005) Pulse pressure variations to predict fluid responsiveness: influence of tidal volume. Intensive Care Med 31:517–523PubMedCrossRef
6.
go back to reference Huang CC, Fu JY, Hu HC, Kao KC, Chen NH, Hsieh MJ, Tsai YH (2008) Prediction of fluid responsiveness in acute respiratory distress syndrome patients ventilated with low tidal volume and high positive end-expiratory pressure. Crit Care Med 36:2810–2816PubMedCrossRef Huang CC, Fu JY, Hu HC, Kao KC, Chen NH, Hsieh MJ, Tsai YH (2008) Prediction of fluid responsiveness in acute respiratory distress syndrome patients ventilated with low tidal volume and high positive end-expiratory pressure. Crit Care Med 36:2810–2816PubMedCrossRef
7.
go back to reference Vallée F, Richard JCM, Mari A, Gallas T, Arsac E, Verlaan PS, Chousterman B, Samii K, Genestal M, Fourcade O (2009) Pulse pressure variations adjusted by alveolar driving pressure to assess fluid responsiveness. Intensive Care Med. doi:10.1007/s00134-009-1478-4 Vallée F, Richard JCM, Mari A, Gallas T, Arsac E, Verlaan PS, Chousterman B, Samii K, Genestal M, Fourcade O (2009) Pulse pressure variations adjusted by alveolar driving pressure to assess fluid responsiveness. Intensive Care Med. doi:10.​1007/​s00134-009-1478-4
8.
go back to reference de Chazal I, Hubmayr RD (2003) Novel aspects of pulmonary mechanics in intensive care. Br J Anaesth 91:81–91PubMedCrossRef de Chazal I, Hubmayr RD (2003) Novel aspects of pulmonary mechanics in intensive care. Br J Anaesth 91:81–91PubMedCrossRef
9.
go back to reference Jardin F, Genevray B, Brun-Ney D, Bourdarias JP (1985) Influence of lung and chest wall compliances on transmission of airway pressure to the pleural space in critically ill patients. Chest 88:653–658PubMedCrossRef Jardin F, Genevray B, Brun-Ney D, Bourdarias JP (1985) Influence of lung and chest wall compliances on transmission of airway pressure to the pleural space in critically ill patients. Chest 88:653–658PubMedCrossRef
10.
go back to reference Talmor D, Sarge T, Malhotra A, O’Donnell CR, Ritz R, Lisbon A, Novack V, Loring SH (2008) Mechanical ventilation guided by esophageal pressure in acute lung injury. N Engl J Med 359:2095–2104PubMedCrossRef Talmor D, Sarge T, Malhotra A, O’Donnell CR, Ritz R, Lisbon A, Novack V, Loring SH (2008) Mechanical ventilation guided by esophageal pressure in acute lung injury. N Engl J Med 359:2095–2104PubMedCrossRef
12.
go back to reference Lamia B, Ochagavia A, Monnet X, Chemla D, Richard C, Teboul JL (2007) Echocardiographic prediction of volume responsiveness in critically ill patients with spontaneously breathing activity. Intensive Care Med 33:1125–1132PubMedCrossRef Lamia B, Ochagavia A, Monnet X, Chemla D, Richard C, Teboul JL (2007) Echocardiographic prediction of volume responsiveness in critically ill patients with spontaneously breathing activity. Intensive Care Med 33:1125–1132PubMedCrossRef
Metadata
Title
Can we use pulse pressure variations to predict fluid responsiveness in patients with ARDS?
Authors
Jean-Yves Lefrant
Daniel De Backer
Publication date
01-06-2009
Publisher
Springer-Verlag
Published in
Intensive Care Medicine / Issue 6/2009
Print ISSN: 0342-4642
Electronic ISSN: 1432-1238
DOI
https://doi.org/10.1007/s00134-009-1479-3

Other articles of this Issue 6/2009

Intensive Care Medicine 6/2009 Go to the issue