Skip to main content
Top
Published in: Archives of Gynecology and Obstetrics 2/2017

01-02-2017 | Maternal-Fetal Medicine

Can we predict successful cervical ripening with prostaglandin E2 vaginal inserts?

Authors: Liran Hiersch, Adi Borovich, Rinat Gabbay-Benziv, Moria Maimon-Cohen, Amir Aviram, Yariv Yogev, Eran Ashwal

Published in: Archives of Gynecology and Obstetrics | Issue 2/2017

Login to get access

Abstract

Purpose

Previous studies have suggested that a variety of maternal and obstetrical characteristics may predict successful prostaglandin E2 (PGE2) cervical ripening. However, in most studies women were administered vaginal tablets or gel so scarce is known regarding potential predictors in women administrated slow-release vaginal inserts. We aimed to characterize the response of cervical ripening for labor induction using slow-release PGE2 vaginal insert and to identify predictors for success.

Methods

A retrospective cohort study in a single center (2013–2015). The association between maternal characteristics at admission and cervical ripening success/failure were explored. Cervical ripening failure was defined as a Bishop’s score <7 following 24 h from cervical ripening or the need for cesarean delivery (CS) due to arrest of dilatation at cervical dilatation ≤5 cm. Cases with major fetal anomalies, multiple gestations, non-vertex presentation or any contraindication for vaginal delivery were excluded.

Results

Of 15,564 deliveries during the study period, 986 (6.3%) women met inclusion criteria, of them, 774 (78.56%) succeeded and 212 (21.5%) failed cervical ripening. Cervical ripening success was associated with (OR, 95% CI): nulliparity (0.42, 0.22–0.81, p = 0.009, i.e., nulliparity was negatively associated with successful ripening), gestational age (GA) at delivery (1.29, 1.02–1.61, p < 0.03), and cervical dilation at admission (4.58, 2.57–8.17, p < 0.001). The indications for labor induction were not associated with cervical ripening success. A prediction model which included the abovementioned characteristics had an AUC of 0.792 (95% CI 0.743–0.840).

Conclusions

Overall, basic parameters, such as parity, cervical dilatation at admission and gestational age can predict successful cervical ripening PGE2 vaginal inserts.
Literature
2.
go back to reference Caughey AB, Sundaram V, Kaimal AJ et al (2009) Maternal and neonatal outcomes of elective induction of labor. Evid Rep Technol Assess (Full Rep) 176:1–257 Caughey AB, Sundaram V, Kaimal AJ et al (2009) Maternal and neonatal outcomes of elective induction of labor. Evid Rep Technol Assess (Full Rep) 176:1–257
3.
go back to reference Prysak M, Castronova FC (1998) Elective induction versus spontaneous labor: a case-control analysis of safety and efficacy. Obstet Gynecol 92:47–52CrossRefPubMed Prysak M, Castronova FC (1998) Elective induction versus spontaneous labor: a case-control analysis of safety and efficacy. Obstet Gynecol 92:47–52CrossRefPubMed
4.
go back to reference Alfirevic Z, Keeney E, Dowswell T et al (2016) Methods to induce labour: a systematic review, network meta-analysis and cost-effectiveness analysis. BJOG. doi:10.1111/1471-0528.13981 Alfirevic Z, Keeney E, Dowswell T et al (2016) Methods to induce labour: a systematic review, network meta-analysis and cost-effectiveness analysis. BJOG. doi:10.​1111/​1471-0528.​13981
6.
7.
go back to reference Ashwal E, Hiersch L, Melamed N et al (2014) Pre-induction cervical ripening: comparing between two vaginal preparations of dinoprostone in women with an unfavorable cervix. J Matern Fetal Neonatal Med 7058:1–6. doi:10.3109/14767058.2014.883375 Ashwal E, Hiersch L, Melamed N et al (2014) Pre-induction cervical ripening: comparing between two vaginal preparations of dinoprostone in women with an unfavorable cervix. J Matern Fetal Neonatal Med 7058:1–6. doi:10.​3109/​14767058.​2014.​883375
8.
go back to reference Hou L, Zhu Y, Ma X et al (2012) Clinical parameters for prediction of successful labor induction after application of intravaginal dinoprostone in nulliparous Chinese women. Med Sci Monit 18:CR518–CR522PubMedPubMedCentral Hou L, Zhu Y, Ma X et al (2012) Clinical parameters for prediction of successful labor induction after application of intravaginal dinoprostone in nulliparous Chinese women. Med Sci Monit 18:CR518–CR522PubMedPubMedCentral
10.
11.
go back to reference Jozwiak M, Oude Rengerink K, Ten Eikelder MLG et al (2013) Foley catheter or prostaglandin E2 inserts for induction of labour at term: an open-label randomized controlled trial (PROBAAT-P trial) and systematic review of literature. Eur J Obstet Gynecol Reprod Biol 170:137–145. doi:10.1016/j.ejogrb.2013.06.017 CrossRefPubMed Jozwiak M, Oude Rengerink K, Ten Eikelder MLG et al (2013) Foley catheter or prostaglandin E2 inserts for induction of labour at term: an open-label randomized controlled trial (PROBAAT-P trial) and systematic review of literature. Eur J Obstet Gynecol Reprod Biol 170:137–145. doi:10.​1016/​j.​ejogrb.​2013.​06.​017 CrossRefPubMed
12.
13.
15.
go back to reference Dollberg S, Haklai Z, Mimouni FB et al (2005) Birth weight standards in the live-born population in Israel. Isr Med Assoc J 7:311–314PubMed Dollberg S, Haklai Z, Mimouni FB et al (2005) Birth weight standards in the live-born population in Israel. Isr Med Assoc J 7:311–314PubMed
16.
go back to reference Macones GA, Hankins GDV, Spong CY et al (2008) The 2008 National Institute of Child Health and Human Development workshop report on electronic fetal monitoring: update on definitions, interpretation, and research guidelines. J Obstet Gynecol Neonatal Nurs 37:510–515. doi:10.1111/j.1552-6909.2008.00284.x CrossRefPubMed Macones GA, Hankins GDV, Spong CY et al (2008) The 2008 National Institute of Child Health and Human Development workshop report on electronic fetal monitoring: update on definitions, interpretation, and research guidelines. J Obstet Gynecol Neonatal Nurs 37:510–515. doi:10.​1111/​j.​1552-6909.​2008.​00284.​x CrossRefPubMed
18.
go back to reference Baños N, Migliorelli F, Posadas E et al (2015) Definition of failed induction of labor and its predictive factors: two unsolved issues of an everyday clinical situation. Fetal Diagn Ther 38:161–169. doi:10.1159/000433429 CrossRefPubMed Baños N, Migliorelli F, Posadas E et al (2015) Definition of failed induction of labor and its predictive factors: two unsolved issues of an everyday clinical situation. Fetal Diagn Ther 38:161–169. doi:10.​1159/​000433429 CrossRefPubMed
19.
go back to reference Jozwiak M, Oude Rengerink K, Benthem M et al (2011) Foley catheter versus vaginal prostaglandin E2 gel for induction of labour at term (PROBAAT trial): an open-label, randomised controlled trial. Lancet (London, England) 378:2095–2103. doi:10.1016/S0140-6736(11)61484-0 CrossRef Jozwiak M, Oude Rengerink K, Benthem M et al (2011) Foley catheter versus vaginal prostaglandin E2 gel for induction of labour at term (PROBAAT trial): an open-label, randomised controlled trial. Lancet (London, England) 378:2095–2103. doi:10.​1016/​S0140-6736(11)61484-0 CrossRef
20.
go back to reference Cromi A, Ghezzi F, Uccella S et al (2012) A randomized trial of preinduction cervical ripening: dinoprostone vaginal insert versus double-balloon catheter. Am J Obstet Gynecol 207(125):e1–e7. doi:10.1016/j.ajog.2012.05.020 Cromi A, Ghezzi F, Uccella S et al (2012) A randomized trial of preinduction cervical ripening: dinoprostone vaginal insert versus double-balloon catheter. Am J Obstet Gynecol 207(125):e1–e7. doi:10.​1016/​j.​ajog.​2012.​05.​020
21.
go back to reference Hernández-Martínez A, Pascual-Pedreño AI, Baño-Garnés AB et al (2016) Predictive model for risk of cesarean section in pregnant women after induction of labor. Arch Gynecol Obstet 293:529–538CrossRefPubMed Hernández-Martínez A, Pascual-Pedreño AI, Baño-Garnés AB et al (2016) Predictive model for risk of cesarean section in pregnant women after induction of labor. Arch Gynecol Obstet 293:529–538CrossRefPubMed
22.
go back to reference Gabbay-Benziv R, Hadar E, Ashwal E et al (2016) Induction of labor: does indication matter? Arch Gynecol Obstet 294:1195–1201CrossRefPubMed Gabbay-Benziv R, Hadar E, Ashwal E et al (2016) Induction of labor: does indication matter? Arch Gynecol Obstet 294:1195–1201CrossRefPubMed
23.
go back to reference Du C, Liu Y, Liu Y et al (2015) Double-balloon catheter vs. dinoprostone vaginal insert for induction of labor with an unfavorable cervix. Arch Gynecol Obstet 291:1221–1227CrossRefPubMed Du C, Liu Y, Liu Y et al (2015) Double-balloon catheter vs. dinoprostone vaginal insert for induction of labor with an unfavorable cervix. Arch Gynecol Obstet 291:1221–1227CrossRefPubMed
24.
25.
go back to reference Rane SM, Guirgis RR, Higgins B, Nicolaides KH (2005) Models for the prediction of successful induction of labor based on pre-induction sonographic measurement of cervical length. J Matern Fetal Neonatal Med 17:315–322. doi:10.1080/14767050500127690 CrossRefPubMed Rane SM, Guirgis RR, Higgins B, Nicolaides KH (2005) Models for the prediction of successful induction of labor based on pre-induction sonographic measurement of cervical length. J Matern Fetal Neonatal Med 17:315–322. doi:10.​1080/​1476705050012769​0 CrossRefPubMed
27.
go back to reference Beckwith L, Magner K, Kritzer S, Warshak CR (2016) Prostaglandin versus mechanical dilation and the effect of maternal obesity on failure to achieve active labor: a cohort study. J Matern Fetal Neonatal Med. doi:10.1080/14767058.2016.1220523 PubMed Beckwith L, Magner K, Kritzer S, Warshak CR (2016) Prostaglandin versus mechanical dilation and the effect of maternal obesity on failure to achieve active labor: a cohort study. J Matern Fetal Neonatal Med. doi:10.​1080/​14767058.​2016.​1220523 PubMed
28.
go back to reference Bortolus R (1999) Determinants of response to intracervical prostaglandin E2 for cervical ripening. Gruppo di Studio sull’Induzione del Travaglio di Parto. Eur J Obstet Gynecol Reprod Biol 87:137–141CrossRefPubMed Bortolus R (1999) Determinants of response to intracervical prostaglandin E2 for cervical ripening. Gruppo di Studio sull’Induzione del Travaglio di Parto. Eur J Obstet Gynecol Reprod Biol 87:137–141CrossRefPubMed
30.
go back to reference Johnston TA, Greer IA, Kelly RW, Calder AA (1993) Plasma prostaglandin metabolite concentrations in normal and dysfunctional labour. Br J Obstet Gynaecol 100:483–488CrossRefPubMed Johnston TA, Greer IA, Kelly RW, Calder AA (1993) Plasma prostaglandin metabolite concentrations in normal and dysfunctional labour. Br J Obstet Gynaecol 100:483–488CrossRefPubMed
Metadata
Title
Can we predict successful cervical ripening with prostaglandin E2 vaginal inserts?
Authors
Liran Hiersch
Adi Borovich
Rinat Gabbay-Benziv
Moria Maimon-Cohen
Amir Aviram
Yariv Yogev
Eran Ashwal
Publication date
01-02-2017
Publisher
Springer Berlin Heidelberg
Published in
Archives of Gynecology and Obstetrics / Issue 2/2017
Print ISSN: 0932-0067
Electronic ISSN: 1432-0711
DOI
https://doi.org/10.1007/s00404-016-4260-1

Other articles of this Issue 2/2017

Archives of Gynecology and Obstetrics 2/2017 Go to the issue