Skip to main content
Top
Published in: International Journal of Computer Assisted Radiology and Surgery 6/2015

01-06-2015 | Original Article

Bone enhancement in ultrasound using local spectrum variations for guiding percutaneous scaphoid fracture fixation procedures

Authors: Emran Mohammad Abu Anas, Alexander Seitel, Abtin Rasoulian, Paul St. John, David Pichora, Kathryn Darras, David Wilson, Victoria A. Lessoway, Ilker Hacihaliloglu, Parvin Mousavi, Robert Rohling, Purang Abolmaesumi

Published in: International Journal of Computer Assisted Radiology and Surgery | Issue 6/2015

Login to get access

Abstract

Purpose

The scaphoid bone is the most frequently fractured bone in the wrist. When fracture fixation is indicated, a screw is inserted into the bone either in an open surgical procedure or percutaneously under fluoroscopic guidance. Due to the complex geometry of the wrist, fracture fixation is a challenging task. Fluoroscopic guidance exposes both the patient and the physician to ionizing radiation. Ultrasound-based guidance has been suggested as a real-time, radiation-free alternative. The main challenge of using ultrasound is the difficulty in interpreting the images due to the low contrast and noisy nature of the data.

Methods

We propose a bone enhancement method that exploits local spectrum features of the ultrasound image. These features are utilized to design a set of quadrature band-pass filters and subsequently estimate the local phase symmetry, where high symmetry is expected at the bone locations. We incorporate the shadow information below the bone surfaces to further enhance the bone responses. The extracted bone surfaces are then used to register a statistical wrist model to ultrasound volumes, allowing the localization and interpretation of the scaphoid bone in the volumes.

Results

Feasibility experiments were performed using phantom and in vivo data. For phantoms, we obtain a surface distance error 1.08 mm and an angular deviation from the main axis of the scaphoid bone smaller than \(5^{\circ }\), which are better compared to previously presented approaches.

Conclusion

The results are promising for further development of a surgical guidance system to enable accurate anatomy localization for guiding percutaneous scaphoid fracture fixations.
Literature
1.
go back to reference Amin DV, Kanade T, Digioia AM, Jaramaz B (2003) Ultrasound registration of the bone surface for surgical navigation. Comput Aided Surg 8(1):1–16CrossRefPubMed Amin DV, Kanade T, Digioia AM, Jaramaz B (2003) Ultrasound registration of the bone surface for surgical navigation. Comput Aided Surg 8(1):1–16CrossRefPubMed
2.
go back to reference Beek M, Abolmaesumi P, Luenam S, Ellis RE, Sellens RW, Pichora DR (2008) Validation of a new surgical procedure for percutaneous scaphoid fixation using intra-operative ultrasound. Med Image Anal 12(2):152–162CrossRefPubMed Beek M, Abolmaesumi P, Luenam S, Ellis RE, Sellens RW, Pichora DR (2008) Validation of a new surgical procedure for percutaneous scaphoid fixation using intra-operative ultrasound. Med Image Anal 12(2):152–162CrossRefPubMed
3.
go back to reference Clarke C, Moore J, Wedlake C, Lee D, Ganapathy S, Salbalbal M, Wilson T, Peters T, Bainbridge D (2010) Virtual reality imaging with real-time ultrasound guidance for facet joint injection: a proof of concept. Anesth Analg 110(5):1461–1463CrossRefPubMed Clarke C, Moore J, Wedlake C, Lee D, Ganapathy S, Salbalbal M, Wilson T, Peters T, Bainbridge D (2010) Virtual reality imaging with real-time ultrasound guidance for facet joint injection: a proof of concept. Anesth Analg 110(5):1461–1463CrossRefPubMed
4.
go back to reference Foroughi P, Boctor E, Swartz M (2007) 2-D ultrasound bone segmentation using dynamic programming. In: IEEE ultrasonics symposium, pp 2523–2526 Foroughi P, Boctor E, Swartz M (2007) 2-D ultrasound bone segmentation using dynamic programming. In: IEEE ultrasonics symposium, pp 2523–2526
5.
go back to reference Gilles J (2013) Empirical wavelet transform. IEEE Trans Signal Process 61(16):3999–4010CrossRef Gilles J (2013) Empirical wavelet transform. IEEE Trans Signal Process 61(16):3999–4010CrossRef
6.
go back to reference Gilles J, Tran G, Osher S (2014) 2D empirical transforms. wavelets, ridgelets, and curvelets revisited. SIAM J Imaging Sci 7(1):157–186CrossRef Gilles J, Tran G, Osher S (2014) 2D empirical transforms. wavelets, ridgelets, and curvelets revisited. SIAM J Imaging Sci 7(1):157–186CrossRef
7.
go back to reference Grau V, Noble JA (2005) Adaptive multiscale ultrasound compounding using phase information. In: Medical image computing and computer-assisted intervention-MICCAI 2005. Springer, Berlin, pp 589–596 Grau V, Noble JA (2005) Adaptive multiscale ultrasound compounding using phase information. In: Medical image computing and computer-assisted intervention-MICCAI 2005. Springer, Berlin, pp 589–596
8.
go back to reference Hacihaliloglu I, Abugharbieh R, Hodgson AJ, Rohling RN (2009) Bone surface localization in ultrasound using image phase-based features. Ultrasound Med Biol 35(9):1475–1487CrossRefPubMed Hacihaliloglu I, Abugharbieh R, Hodgson AJ, Rohling RN (2009) Bone surface localization in ultrasound using image phase-based features. Ultrasound Med Biol 35(9):1475–1487CrossRefPubMed
9.
go back to reference Hacihaliloglu I, Abugharbieh R, Hodgson AJ, Rohling RN (2011) Automatic adaptive parameterization in local phase feature-based bone segmentation in ultrasound. Ultrasound Med Biol 37(10):1689–1703PubMed Hacihaliloglu I, Abugharbieh R, Hodgson AJ, Rohling RN (2011) Automatic adaptive parameterization in local phase feature-based bone segmentation in ultrasound. Ultrasound Med Biol 37(10):1689–1703PubMed
10.
go back to reference Hacihaliloglu I, Abugharbieh R, Hodgson AJ, Rohling RN, Guy P (2012) Automatic bone localization and fracture detection from volumetric ultrasound images using 3-D local phase features. Ultrasound Med Biol 38(1):128–144CrossRefPubMed Hacihaliloglu I, Abugharbieh R, Hodgson AJ, Rohling RN, Guy P (2012) Automatic bone localization and fracture detection from volumetric ultrasound images using 3-D local phase features. Ultrasound Med Biol 38(1):128–144CrossRefPubMed
11.
go back to reference Hacihaliloglu I, Rasoulian A, Rohling RN, Abolmaesumi P (2014) Local phase tensor features for 3D ultrasound to statistical shape+pose spine model registration. IEEE Trans Med Imaging 33(11):2167–2179CrossRefPubMed Hacihaliloglu I, Rasoulian A, Rohling RN, Abolmaesumi P (2014) Local phase tensor features for 3D ultrasound to statistical shape+pose spine model registration. IEEE Trans Med Imaging 33(11):2167–2179CrossRefPubMed
12.
go back to reference Jain AK, Taylor RH (2004) Understanding bone responses in B-mode ultrasound images and automatic bone surface extraction using a Bayesian probabilistic framework. In: Medical imaging, international society for optics and photonics, pp 131–142 Jain AK, Taylor RH (2004) Understanding bone responses in B-mode ultrasound images and automatic bone surface extraction using a Bayesian probabilistic framework. In: Medical imaging, international society for optics and photonics, pp 131–142
13.
go back to reference Khallaghi S, Mousavi P, Gong RH, Gill S, Boisvert J, Fichtinger G, Pichora D, Borschneck D, Abolmaesumi P (2010) Registration of a statistical shape model of the lumbar spine to 3d ultrasound images. In: Medical image computing and computer-assisted intervention-MICCAI 2010. Springer, Berlin, pp 68–75 Khallaghi S, Mousavi P, Gong RH, Gill S, Boisvert J, Fichtinger G, Pichora D, Borschneck D, Abolmaesumi P (2010) Registration of a statistical shape model of the lumbar spine to 3d ultrasound images. In: Medical image computing and computer-assisted intervention-MICCAI 2010. Springer, Berlin, pp 68–75
14.
go back to reference Kovesi P (1997) Symmetry and asymmetry from local phase. In: Tenth Australian joint conference on artificial intelligence, vol 190. Citeseer Kovesi P (1997) Symmetry and asymmetry from local phase. In: Tenth Australian joint conference on artificial intelligence, vol 190. Citeseer
15.
go back to reference Kowal J, Amstutz C, Langlotz F, Talib H, Ballester MG (2007) Automated bone contour detection in ultrasound b-mode images for minimally invasive registration in computer-assisted surgery—an in vitro evaluation. Int J Med Robot Comput Assist Surg 3(4):341–348CrossRef Kowal J, Amstutz C, Langlotz F, Talib H, Ballester MG (2007) Automated bone contour detection in ultrasound b-mode images for minimally invasive registration in computer-assisted surgery—an in vitro evaluation. Int J Med Robot Comput Assist Surg 3(4):341–348CrossRef
16.
go back to reference Madsen EL, Hobson MA, Shi H, Varghese T, Frank GR (2005) Tissue-mimicking agar/gelatin materials for use in heterogeneous elastography phantoms. Phys Med Biol 50(23):5597CrossRefPubMedCentralPubMed Madsen EL, Hobson MA, Shi H, Varghese T, Frank GR (2005) Tissue-mimicking agar/gelatin materials for use in heterogeneous elastography phantoms. Phys Med Biol 50(23):5597CrossRefPubMedCentralPubMed
17.
go back to reference Maleike D, Nolden M, Meinzer HP, Wolf I (2009) Interactive segmentation framework of the medical imaging interaction toolkit. Comput Methods Program Biomed 96(1):72–83CrossRef Maleike D, Nolden M, Meinzer HP, Wolf I (2009) Interactive segmentation framework of the medical imaging interaction toolkit. Comput Methods Program Biomed 96(1):72–83CrossRef
18.
19.
go back to reference Menapace KA, Larabee L, Arnoczky SP, Neginhal VS, Dass AG, Ross LM (2001) Anatomic placement of the Herbert-Whipple screw in scaphoid fractures: a cadaver study. J Hand Surg 26(5):883–892CrossRef Menapace KA, Larabee L, Arnoczky SP, Neginhal VS, Dass AG, Ross LM (2001) Anatomic placement of the Herbert-Whipple screw in scaphoid fractures: a cadaver study. J Hand Surg 26(5):883–892CrossRef
20.
go back to reference Merrell G, Slade J (2008) Technique for percutaneous fixation of displaced and nondisplaced acute scaphoid fractures and select nonunions. J Hand Surg 33(6):966–973CrossRef Merrell G, Slade J (2008) Technique for percutaneous fixation of displaced and nondisplaced acute scaphoid fractures and select nonunions. J Hand Surg 33(6):966–973CrossRef
21.
go back to reference Mohammad Abu Anas E, Rasoulian A, John PS, Pichora DR, Rohling R, Abolmaesumi P (2014) A statistical shape+pose model for segmentation of wrist CT images. In: SPIE medical imaging, vol 9034, pp T1–T8 Mohammad Abu Anas E, Rasoulian A, John PS, Pichora DR, Rohling R, Abolmaesumi P (2014) A statistical shape+pose model for segmentation of wrist CT images. In: SPIE medical imaging, vol 9034, pp T1–T8
22.
go back to reference Mink van der Molen A, Groothoff J, Visser G, Robinson P, Eisma W (1999) Time off work due to scaphoid fractures and other carpal injuries in The Netherlands in the period 1990 to 1993. J Hand Surg Br Eur Vol 24(2):193–198CrossRef Mink van der Molen A, Groothoff J, Visser G, Robinson P, Eisma W (1999) Time off work due to scaphoid fractures and other carpal injuries in The Netherlands in the period 1990 to 1993. J Hand Surg Br Eur Vol 24(2):193–198CrossRef
23.
go back to reference Nagpal S, Abolmaesumi P, Rasoulian A, Ungi T, Hacihaliloglu I, Osborn J, Borschneck DP, Lessoway VA, Rohling RN, Mousavi P (2014) CT to US registration of the lumbar spine: a clinical feasibility study. In: Information processing in computer-assisted interventions. Springer, Berlin, pp 108–117 Nagpal S, Abolmaesumi P, Rasoulian A, Ungi T, Hacihaliloglu I, Osborn J, Borschneck DP, Lessoway VA, Rohling RN, Mousavi P (2014) CT to US registration of the lumbar spine: a clinical feasibility study. In: Information processing in computer-assisted interventions. Springer, Berlin, pp 108–117
24.
go back to reference Pao VS, Chang J (2003) Scaphoid nonunion: diagnosis and treatment. Plast Reconstr Surg 112(6):1666–1677CrossRefPubMed Pao VS, Chang J (2003) Scaphoid nonunion: diagnosis and treatment. Plast Reconstr Surg 112(6):1666–1677CrossRefPubMed
25.
go back to reference Penney GP, Barratt DC, Chan CS, Slomczykowski M, Carter TJ, Edwards PJ, Hawkes DJ (2006) Cadaver validation of intensity-based ultrasound to CT registration. Med Image Anal 10(3):385–395CrossRefPubMed Penney GP, Barratt DC, Chan CS, Slomczykowski M, Carter TJ, Edwards PJ, Hawkes DJ (2006) Cadaver validation of intensity-based ultrasound to CT registration. Med Image Anal 10(3):385–395CrossRefPubMed
26.
go back to reference Rahmatullah B, Papageorghiou AT, Noble JA (2012) Integration of local and global features for anatomical object detection in ultrasound. In: Medical image computing and computer-assisted intervention-MICCAI 2012. Springer, Berlin, pp 402–409 Rahmatullah B, Papageorghiou AT, Noble JA (2012) Integration of local and global features for anatomical object detection in ultrasound. In: Medical image computing and computer-assisted intervention-MICCAI 2012. Springer, Berlin, pp 402–409
27.
go back to reference Rajpoot K, Grau V, Noble JA (2009) Local-phase based 3D boundary detection using monogenic signal and its application to real-time 3-D echocardiography images. In: IEEE international symposium on biomedical imaging: from nano to macro, 2009 (ISBI’09). IEEE, pp 783–786 Rajpoot K, Grau V, Noble JA (2009) Local-phase based 3D boundary detection using monogenic signal and its application to real-time 3-D echocardiography images. In: IEEE international symposium on biomedical imaging: from nano to macro, 2009 (ISBI’09). IEEE, pp 783–786
28.
go back to reference Rasoulian A, Rohling R, Abolmaesumi P (2013) Lumbar spine segmentation using a statistical multi-vertebrae anatomical shape+pose model. IEEE Trans Med Imaging 32(10):1890–1900CrossRefPubMed Rasoulian A, Rohling R, Abolmaesumi P (2013) Lumbar spine segmentation using a statistical multi-vertebrae anatomical shape+pose model. IEEE Trans Med Imaging 32(10):1890–1900CrossRefPubMed
29.
go back to reference Smith EJ, Al-Sanawi HA, Gammon B, John PJS, Pichora DR, Ellis RE (2012) Volume slicing of cone-beam computed tomography images for navigation of percutaneous scaphoid fixation. Int J Comput Assist Radiol Surg 7(3):433–444CrossRefPubMed Smith EJ, Al-Sanawi HA, Gammon B, John PJS, Pichora DR, Ellis RE (2012) Volume slicing of cone-beam computed tomography images for navigation of percutaneous scaphoid fixation. Int J Comput Assist Radiol Surg 7(3):433–444CrossRefPubMed
30.
go back to reference Tran D, Rohling RN (2010) Automatic detection of lumbar anatomy in ultrasound images of human subjects. IEEE Trans Biomed Eng 57(9):2248–2256CrossRefPubMed Tran D, Rohling RN (2010) Automatic detection of lumbar anatomy in ultrasound images of human subjects. IEEE Trans Biomed Eng 57(9):2248–2256CrossRefPubMed
31.
go back to reference Yan CX, Goulet B, Pelletier J, Chen SJS, Tampieri D, Collins DL (2011) Towards accurate, robust and practical ultrasound-CT registration of vertebrae for image-guided spine surgery. Int J Comput Assist Radiol Surg 6(4):523–537CrossRefPubMed Yan CX, Goulet B, Pelletier J, Chen SJS, Tampieri D, Collins DL (2011) Towards accurate, robust and practical ultrasound-CT registration of vertebrae for image-guided spine surgery. Int J Comput Assist Radiol Surg 6(4):523–537CrossRefPubMed
Metadata
Title
Bone enhancement in ultrasound using local spectrum variations for guiding percutaneous scaphoid fracture fixation procedures
Authors
Emran Mohammad Abu Anas
Alexander Seitel
Abtin Rasoulian
Paul St. John
David Pichora
Kathryn Darras
David Wilson
Victoria A. Lessoway
Ilker Hacihaliloglu
Parvin Mousavi
Robert Rohling
Purang Abolmaesumi
Publication date
01-06-2015
Publisher
Springer Berlin Heidelberg
Published in
International Journal of Computer Assisted Radiology and Surgery / Issue 6/2015
Print ISSN: 1861-6410
Electronic ISSN: 1861-6429
DOI
https://doi.org/10.1007/s11548-015-1181-6

Other articles of this Issue 6/2015

International Journal of Computer Assisted Radiology and Surgery 6/2015 Go to the issue

Editorial

Preface