Skip to main content
Top
Published in: BMC Anesthesiology 1/2020

Open Access 01-12-2020 | Blood Pressure Measurement | Research article

Upper limb dimensions in adults presenting for elective surgery – implications for blood pressure measurement

Authors: Christopher Chow, Peter Ceglowski, Katie Lehane, Anita Pelecanos, Kellie Wren, Victoria A. Eley

Published in: BMC Anesthesiology | Issue 1/2020

Login to get access

Abstract

Background

Arm conicity is associated with non-invasive blood pressure (NIBP) measurement error and may be avoided by using finger cuffs. Predicting arm conicity may help decisions regarding NIBP measurement techniques.

Methods

We obtained upper limb measurements of adults presenting to the Pre-Anesthetic Clinic to determine: the suitability of arm and finger cuff sizes; the best anthropometric predictor of arm conicity based on the right arm slant angle; the incidence of a right arm slant angle < 83 degrees. Right mid-arm circumference (MAC) was compared to recommended cuff sizes and finger circumference compared to available cuffs. Slant angle was calculated from the measurements obtained. Linear regression was used to determine the better predictor of right arm slant angle. Correlation coefficients were calculated and R2 values compared.

Results

Four hundred fifty-four patients participated and 453 had cone-shaped arms. One participant (0.2, 95% CI 0.0–1.2) had a MAC outside the recommended cuff range. Twenty-five participants (5.5, 95% CI 3.6–8.0) had a middle finger circumference greater than the largest ClearSight™ cuff. Body mass index (BMI), weight and right MAC all had low to moderate correlation with right arm slant angle (r = − 0.49, − 0.39, − 0.48, all p < 0.001) and regression revealed R2 values of 0.24, 0.15 and 0.23. Six participants (1.3, 95% CI 0.5–2.9) had a slant angle < 83 degrees.

Conclusion

Current NIBP equipment caters for most patients, based on the traditional measure of MAC. The utility of finger cuffs is limited by cuff size. BMI and right MAC showed the most promise in predicting arm conicity.
Appendix
Available only for authorised users
Literature
1.
go back to reference Sanders RD, Hughes F, Shaw A, Thompson A, Bader A, Hoeft A, Williams DA, Grocott MP, Mythen MG, Miller TE. Perioperative quality initiative consensus statement on preoperative blood pressure, risk and outcomes for elective surgery. Br J Anaesth. 2019;122:552–62.CrossRef Sanders RD, Hughes F, Shaw A, Thompson A, Bader A, Hoeft A, Williams DA, Grocott MP, Mythen MG, Miller TE. Perioperative quality initiative consensus statement on preoperative blood pressure, risk and outcomes for elective surgery. Br J Anaesth. 2019;122:552–62.CrossRef
2.
go back to reference Whelton PK, Carey RM, Aronow WS, Casey DE, Collins KJ, Dennison Himmelfarb C, DePalma SM, Gidding S, Jamerson KA, Jones DW et al: 2017 ACC/AHA/AAPA/ABC/ACPM/AGS/APhA/ASH/ASPC/NMA/PCNA guideline for the prevention, Detection, Evaluation, and Management of High Blood Pressure in Adults. A Report of the American College of Cardiology/American Heart Association Task Force on Clinical Practice Guidelines 2017. Whelton PK, Carey RM, Aronow WS, Casey DE, Collins KJ, Dennison Himmelfarb C, DePalma SM, Gidding S, Jamerson KA, Jones DW et al: 2017 ACC/AHA/AAPA/ABC/ACPM/AGS/APhA/ASH/ASPC/NMA/PCNA guideline for the prevention, Detection, Evaluation, and Management of High Blood Pressure in Adults. A Report of the American College of Cardiology/American Heart Association Task Force on Clinical Practice Guidelines 2017.
3.
go back to reference Riva-Rocci S. Un sfigmomanometro nuovo. Gaz Med Torino. 1896;47:981–96. Riva-Rocci S. Un sfigmomanometro nuovo. Gaz Med Torino. 1896;47:981–96.
5.
go back to reference Von Recklinghausen H. Ueber blutdruckmessung beim menschen. Naunyn Schmiedeberg's Arch Pharmacol. 1901;46:78–132.CrossRef Von Recklinghausen H. Ueber blutdruckmessung beim menschen. Naunyn Schmiedeberg's Arch Pharmacol. 1901;46:78–132.CrossRef
6.
go back to reference Pickering TG, Hall JE, Appel LJ, Falkner BE, Graves J, Hill MN, Jones DW, Kurtz T, Sheps SG, Roccella EJ. Recommendations for blood pressure measurement in humans and experimental animals part 1: blood pressure measurement in humans: a statement for professionals from the Subcommittee of Professional and Public Education of the American Heart Association Council on high blood pressure research. Hypertension. 2005;45:142–61.CrossRef Pickering TG, Hall JE, Appel LJ, Falkner BE, Graves J, Hill MN, Jones DW, Kurtz T, Sheps SG, Roccella EJ. Recommendations for blood pressure measurement in humans and experimental animals part 1: blood pressure measurement in humans: a statement for professionals from the Subcommittee of Professional and Public Education of the American Heart Association Council on high blood pressure research. Hypertension. 2005;45:142–61.CrossRef
7.
go back to reference Bonso E, Saladini F, Zanier A, Benetti E, Dorigatti F, Palatini P. Accuracy of a single rigid conical cuff with standard-size bladder coupled to an automatic oscillometric device over a wide range of arm circumferences. Hypertens Res. 2010;33:1186–91.CrossRef Bonso E, Saladini F, Zanier A, Benetti E, Dorigatti F, Palatini P. Accuracy of a single rigid conical cuff with standard-size bladder coupled to an automatic oscillometric device over a wide range of arm circumferences. Hypertens Res. 2010;33:1186–91.CrossRef
8.
go back to reference Palatini P, Benetti E, Fania C, Malipiero G, Saladini F. Rectangular cuffs may overestimate blood pressure in individuals with large conical arms. J Hypertens. 2012;30:530–6.CrossRef Palatini P, Benetti E, Fania C, Malipiero G, Saladini F. Rectangular cuffs may overestimate blood pressure in individuals with large conical arms. J Hypertens. 2012;30:530–6.CrossRef
9.
go back to reference Townsend RR. Of funnel arms, Popeye, and other-sized challenges. J Clin Hypertens. 2005;7:755–6.CrossRef Townsend RR. Of funnel arms, Popeye, and other-sized challenges. J Clin Hypertens. 2005;7:755–6.CrossRef
10.
go back to reference Cossrow N, Falkner B. Race/ethnic issues in obesity and obesity-related comorbidities. J Clin Endocrinol Metab. 2004;89:2590–4.CrossRef Cossrow N, Falkner B. Race/ethnic issues in obesity and obesity-related comorbidities. J Clin Endocrinol Metab. 2004;89:2590–4.CrossRef
13.
go back to reference World Health Organization. Obesity: managing and preventing the global endemic. Geneva: World Health Organization; 2000. World Health Organization. Obesity: managing and preventing the global endemic. Geneva: World Health Organization; 2000.
14.
go back to reference Palatini P, Asmar R. Cuff challenges in blood pressure measurement. J Clin Hypertens. 2018;20:1100–3.CrossRef Palatini P, Asmar R. Cuff challenges in blood pressure measurement. J Clin Hypertens. 2018;20:1100–3.CrossRef
15.
go back to reference Stergiou GS, Alpert B, Mieke S, Asmar R, Atkins N, Eckert S, Frick G, Friedman B, Graßl T, Ichikawa T. A universal standard for the validation of blood pressure measuring devices: Association for the Advancement of medical instrumentation/European Society of Hypertension/International Organization for Standardization (AAMI/ESH/ISO) collaboration statement. Hypertension. 2018;71:368–74.CrossRef Stergiou GS, Alpert B, Mieke S, Asmar R, Atkins N, Eckert S, Frick G, Friedman B, Graßl T, Ichikawa T. A universal standard for the validation of blood pressure measuring devices: Association for the Advancement of medical instrumentation/European Society of Hypertension/International Organization for Standardization (AAMI/ESH/ISO) collaboration statement. Hypertension. 2018;71:368–74.CrossRef
16.
go back to reference Ostchega Y, Hughes JP, Zhang G, Nwankwo T, Chiappa MM. Mean mid-arm circumference and blood pressure cuff sizes for US adults: National Health and nutrition examination survey, 1999–2010. Blood Press Monit. 2013;18:138–43.CrossRef Ostchega Y, Hughes JP, Zhang G, Nwankwo T, Chiappa MM. Mean mid-arm circumference and blood pressure cuff sizes for US adults: National Health and nutrition examination survey, 1999–2010. Blood Press Monit. 2013;18:138–43.CrossRef
17.
go back to reference Bray GA, Kim KK, Wilding JPH. Obesity: a chronic relapsing progressive disease process. A position statement of the world obesity federation. Obes Rev. 2017;18:715–23.CrossRef Bray GA, Kim KK, Wilding JPH. Obesity: a chronic relapsing progressive disease process. A position statement of the world obesity federation. Obes Rev. 2017;18:715–23.CrossRef
18.
go back to reference Palatini P, Parati G. Blood pressure measurement in very obese patients: a challenging problem. J Hypertens. 2011;29:425–9.CrossRef Palatini P, Parati G. Blood pressure measurement in very obese patients: a challenging problem. J Hypertens. 2011;29:425–9.CrossRef
19.
go back to reference Deng Z, Liang F. Numerical analysis of stress distribution in the upper arm tissues under an inflatable cuff: implications for noninvasive blood pressure measurement. Acta Mech Sinica. 2016;32:959–69.CrossRef Deng Z, Liang F. Numerical analysis of stress distribution in the upper arm tissues under an inflatable cuff: implications for noninvasive blood pressure measurement. Acta Mech Sinica. 2016;32:959–69.CrossRef
20.
go back to reference Huige M, Vanvollenhoven E, Weeda H, Arntzenius A. Influence of cuff size and cuff design on indirect blood-pressure measurement. Acta Cardiol. 1978;2:88–90. Huige M, Vanvollenhoven E, Weeda H, Arntzenius A. Influence of cuff size and cuff design on indirect blood-pressure measurement. Acta Cardiol. 1978;2:88–90.
21.
go back to reference Maxwell GF, Pruijt JF, Arntzenius AC. Comparison of the conical cuff and the standard rectangular cuffs. Int J Epidemiol. 1985;14:468.CrossRef Maxwell GF, Pruijt JF, Arntzenius AC. Comparison of the conical cuff and the standard rectangular cuffs. Int J Epidemiol. 1985;14:468.CrossRef
22.
go back to reference Martina JR, Westerhof BE, van Goudoever J, de Beaumont EMH, Truijen J, Kim Y-S, Immink RV, Jöbsis DA, Hollmann MW, Lahpor JR. Noninvasive continuous arterial blood pressure monitoring with Nexfin®. Anesthesiology. 2012;116:1092–103.CrossRef Martina JR, Westerhof BE, van Goudoever J, de Beaumont EMH, Truijen J, Kim Y-S, Immink RV, Jöbsis DA, Hollmann MW, Lahpor JR. Noninvasive continuous arterial blood pressure monitoring with Nexfin®. Anesthesiology. 2012;116:1092–103.CrossRef
23.
go back to reference Ilies C, Bauer M, Berg P, Rosenberg J, Hedderich J, Bein B, Hinz J, Hanss R. Investigation of the agreement of a continuous non-invasive arterial pressure device in comparison with invasive radial artery measurement. Br J Anaesth. 2012;108:202–10.CrossRef Ilies C, Bauer M, Berg P, Rosenberg J, Hedderich J, Bein B, Hinz J, Hanss R. Investigation of the agreement of a continuous non-invasive arterial pressure device in comparison with invasive radial artery measurement. Br J Anaesth. 2012;108:202–10.CrossRef
24.
go back to reference Fischer M, Avram R, Cârjaliu I, Massetti M, Gérard J, Hanouz J, Fellahi J. Non-invasive continuous arterial pressure and cardiac index monitoring with Nexfin after cardiac surgery. Br J Anaesth. 2012;109:514–21.CrossRef Fischer M, Avram R, Cârjaliu I, Massetti M, Gérard J, Hanouz J, Fellahi J. Non-invasive continuous arterial pressure and cardiac index monitoring with Nexfin after cardiac surgery. Br J Anaesth. 2012;109:514–21.CrossRef
Metadata
Title
Upper limb dimensions in adults presenting for elective surgery – implications for blood pressure measurement
Authors
Christopher Chow
Peter Ceglowski
Katie Lehane
Anita Pelecanos
Kellie Wren
Victoria A. Eley
Publication date
01-12-2020
Publisher
BioMed Central
Published in
BMC Anesthesiology / Issue 1/2020
Electronic ISSN: 1471-2253
DOI
https://doi.org/10.1186/s12871-020-00994-z

Other articles of this Issue 1/2020

BMC Anesthesiology 1/2020 Go to the issue