Abstract

Background

To evaluate the relationships between Reichert Ocular Response Analyzer (ORA) parameters corneal hysteresis (CH) and corneal response factor (CRF) and ocular dimensions, age and intraocular pressure.

Methods

Two hundred and twelve eyes of 212 participants with no ocular pathology had CH and CRF measured with the ORA. Intraocular pressure (IOP) was measured with the Dynamic Contour tonometer and central corneal thickness (CCT) was also evaluated. Partial least squares linear regression (PLSLR) analyses were performed to examine the relationships between each response variable, CH and CRF, and the predictor variables age, corneal curvature (CC), axial length (AL), CCT and IOP.

Results

CH was positively associated with CCT and negatively associated with age (scaled coefficients: CCT 0.62, p < 0.0001; age -0.55, p <0.0001; r2 = 0.25). CRF was positively associated with CCT and DCT IOP and negatively associated with age and AL (scaled coefficients: CCT 0.89, p < 0.0001; DCT IOP 0.46, p < 0.01; age – 0.60, p < 0.0001; AL -0.37, p < 0.01; r2 = 0.43). There was no significant association between CC and CH or CRF.

Conclusions

The study suggests that age and CCT are strongly associated with CH and CRF, and that the latter is also influenced by AL and IOP. However, the variables studied could explain only 25% and 43% of the measured variation in CH and CRF, respectively, suggesting other factors also affect the values of these measurements.
Appendix
Available only for authorised users
Literature
1.
go back to reference Lau W, Pye D: Changes in corneal biomechanics and applanation tonometry with induced corneal swelling. Invest Ophthalmol Vis Sci. 2011, 52 (6): 3207-3214. 10.1167/iovs.10-6754.CrossRefPubMed Lau W, Pye D: Changes in corneal biomechanics and applanation tonometry with induced corneal swelling. Invest Ophthalmol Vis Sci. 2011, 52 (6): 3207-3214. 10.1167/iovs.10-6754.CrossRefPubMed
2.
go back to reference Tonnu PA, Ho T, Newson T, El Sheikh A, Sharma K, White E, Bunce C, Garway-Heath D: The influence of central corneal thickness and age on intraocular pressure measured by pneumotonometry, non-contact tonometry, the Tono-Pen XL, and Goldmann applanation tonometry. Br J Ophthalmol. 2005, 89 (7): 851-854. 10.1136/bjo.2004.056622.CrossRefPubMedPubMedCentral Tonnu PA, Ho T, Newson T, El Sheikh A, Sharma K, White E, Bunce C, Garway-Heath D: The influence of central corneal thickness and age on intraocular pressure measured by pneumotonometry, non-contact tonometry, the Tono-Pen XL, and Goldmann applanation tonometry. Br J Ophthalmol. 2005, 89 (7): 851-854. 10.1136/bjo.2004.056622.CrossRefPubMedPubMedCentral
3.
go back to reference Schweitzer C, Roberts CJ, Mahmoud AM, Colin J, Maurice-Tison S, Kerautret J: Screening of forme fruste keratoconus with the ocular response analyzer. Invest Ophthalmol Vis Sci. 2010, 51 (5): 2403-2410. 10.1167/iovs.09-3689.CrossRefPubMed Schweitzer C, Roberts CJ, Mahmoud AM, Colin J, Maurice-Tison S, Kerautret J: Screening of forme fruste keratoconus with the ocular response analyzer. Invest Ophthalmol Vis Sci. 2010, 51 (5): 2403-2410. 10.1167/iovs.09-3689.CrossRefPubMed
4.
go back to reference del Buey MA, Cristobal JA, Ascaso FJ, Lavilla L, Lanchares E: Biomechanical properties of the cornea in Fuchs’ corneal dystrophy. Invest Ophthalmol Vis Sci. 2009, 50 (7): 3199-3202. 10.1167/iovs.08-3312.CrossRefPubMed del Buey MA, Cristobal JA, Ascaso FJ, Lavilla L, Lanchares E: Biomechanical properties of the cornea in Fuchs’ corneal dystrophy. Invest Ophthalmol Vis Sci. 2009, 50 (7): 3199-3202. 10.1167/iovs.08-3312.CrossRefPubMed
5.
go back to reference Roberts C: Biomechanics of the cornea and wavefront-guided laser refractive surgery. J Refract Surg. 2002, 18 (5): S589-S592.PubMed Roberts C: Biomechanics of the cornea and wavefront-guided laser refractive surgery. J Refract Surg. 2002, 18 (5): S589-S592.PubMed
6.
go back to reference Congdon NG, Broman AT, Bandeen-Roche K, Grover D, Quigley HA: Central corneal thickness and corneal hysteresis associated with glaucoma damage. Am J Ophthalmol. 2006, 141 (5): 868-875. 10.1016/j.ajo.2005.12.007.CrossRefPubMed Congdon NG, Broman AT, Bandeen-Roche K, Grover D, Quigley HA: Central corneal thickness and corneal hysteresis associated with glaucoma damage. Am J Ophthalmol. 2006, 141 (5): 868-875. 10.1016/j.ajo.2005.12.007.CrossRefPubMed
7.
go back to reference Wells AP, Garway-Heath DT, Poostchi A, Wong T, Chan KC, Sachdev N: Corneal biomechanics and optic nerve head compliance: corneal hysteresis but Not corneal thickness correlates with optic nerve surface deformation in glaucoma patients. Invest Ophthalmol Vis Sci. 2008, 49 (8): 3262-3268. 10.1167/iovs.07-1556.CrossRefPubMed Wells AP, Garway-Heath DT, Poostchi A, Wong T, Chan KC, Sachdev N: Corneal biomechanics and optic nerve head compliance: corneal hysteresis but Not corneal thickness correlates with optic nerve surface deformation in glaucoma patients. Invest Ophthalmol Vis Sci. 2008, 49 (8): 3262-3268. 10.1167/iovs.07-1556.CrossRefPubMed
9.
go back to reference Dupps WJ: Hysteresis: new mechanospeak for the ophthalmologist. J Cataract Refract Surg. 2007, 33 (9): 1499-1501. 10.1016/j.jcrs.2007.07.008.CrossRefPubMed Dupps WJ: Hysteresis: new mechanospeak for the ophthalmologist. J Cataract Refract Surg. 2007, 33 (9): 1499-1501. 10.1016/j.jcrs.2007.07.008.CrossRefPubMed
10.
go back to reference Kotecha A: What biomechanical properties of the cornea are relevant for the clinician?. Surv Ophthalmol. 2007, 52 (Suppl 2): S109-S114.CrossRefPubMed Kotecha A: What biomechanical properties of the cornea are relevant for the clinician?. Surv Ophthalmol. 2007, 52 (Suppl 2): S109-S114.CrossRefPubMed
11.
go back to reference Kotecha A, Elsheikh A, Roberts CR, Zhu H, Garway-Heath DF: Corneal thickness- and age-related biomechanical properties of the cornea measured with the ocular response analyzer. Invest Ophthalmol Vis Sci. 2006, 47 (12): 5337-5347. 10.1167/iovs.06-0557.CrossRefPubMed Kotecha A, Elsheikh A, Roberts CR, Zhu H, Garway-Heath DF: Corneal thickness- and age-related biomechanical properties of the cornea measured with the ocular response analyzer. Invest Ophthalmol Vis Sci. 2006, 47 (12): 5337-5347. 10.1167/iovs.06-0557.CrossRefPubMed
12.
go back to reference Leite MT, Alencar LM, Gore C, Weinreb RN, Sample PA, Zangwill LM, Medeiros FA: Comparison of corneal biomechanical properties between healthy blacks and whites using the Ocular Response Analyzer. Am J Ophthalmol. 2010, 150 (2): 163-168. 10.1016/j.ajo.2010.02.024. e161CrossRefPubMedPubMedCentral Leite MT, Alencar LM, Gore C, Weinreb RN, Sample PA, Zangwill LM, Medeiros FA: Comparison of corneal biomechanical properties between healthy blacks and whites using the Ocular Response Analyzer. Am J Ophthalmol. 2010, 150 (2): 163-168. 10.1016/j.ajo.2010.02.024. e161CrossRefPubMedPubMedCentral
13.
go back to reference Recep OF, Hasiripi H, Vayisoglu E, Kalayci D, Sarikatipoglu H: Accurate time interval in repeated tonometry. Acta Ophthalmol Scand. 1998, 76 (5): 603-605. 10.1034/j.1600-0420.1998.760518.x.CrossRefPubMed Recep OF, Hasiripi H, Vayisoglu E, Kalayci D, Sarikatipoglu H: Accurate time interval in repeated tonometry. Acta Ophthalmol Scand. 1998, 76 (5): 603-605. 10.1034/j.1600-0420.1998.760518.x.CrossRefPubMed
14.
go back to reference Wold H: Estimation of Principal Components and Related Models by Iterative Least Squares. Multivariate Analysis. Edited by: Krishnaiah PR. 1966, New York: Academic Wold H: Estimation of Principal Components and Related Models by Iterative Least Squares. Multivariate Analysis. Edited by: Krishnaiah PR. 1966, New York: Academic
15.
go back to reference Lachenbruch PA, Mickey MR: Estimation of error rates in discriminant analysis. Technometrics. 1968, 10 (1): 1-11. 10.1080/00401706.1968.10490530.CrossRef Lachenbruch PA, Mickey MR: Estimation of error rates in discriminant analysis. Technometrics. 1968, 10 (1): 1-11. 10.1080/00401706.1968.10490530.CrossRef
16.
go back to reference Boehm AG, Weber A, Pillunat LE, Koch R, Spoerl E: Dynamic contour tonometry in comparison to intracameral IOP measurements. Invest Ophthalmol Vis Sci. 2008, 49 (6): 2472-2477. 10.1167/iovs.07-1366.CrossRefPubMed Boehm AG, Weber A, Pillunat LE, Koch R, Spoerl E: Dynamic contour tonometry in comparison to intracameral IOP measurements. Invest Ophthalmol Vis Sci. 2008, 49 (6): 2472-2477. 10.1167/iovs.07-1366.CrossRefPubMed
17.
go back to reference Glass DH, Roberts CJ, Litsky AS, Weber PA: A viscoelastic biomechanical model of the cornea describing the effect of viscosity and elasticity on hysteresis. Invest Ophthalmol Vis Sci. 2008, 49 (9): 3919-3926. 10.1167/iovs.07-1321.CrossRefPubMed Glass DH, Roberts CJ, Litsky AS, Weber PA: A viscoelastic biomechanical model of the cornea describing the effect of viscosity and elasticity on hysteresis. Invest Ophthalmol Vis Sci. 2008, 49 (9): 3919-3926. 10.1167/iovs.07-1321.CrossRefPubMed
18.
go back to reference Daxer A, Misof K, Grabner B, Ettl A, Fratzl P: Collagen fibrils in the human corneal stroma: structure and aging. Invest Ophthalmol Vis Sci. 1998, 39 (3): 644-648.PubMed Daxer A, Misof K, Grabner B, Ettl A, Fratzl P: Collagen fibrils in the human corneal stroma: structure and aging. Invest Ophthalmol Vis Sci. 1998, 39 (3): 644-648.PubMed
19.
go back to reference Elsheikh A, Wang D, Brown M, Rama P, Campanelli M, Pye D: Assessment of corneal biomechanical properties and their variation with age. Curr Eye Res. 2007, 32 (1): 11-19. 10.1080/02713680601077145.CrossRefPubMed Elsheikh A, Wang D, Brown M, Rama P, Campanelli M, Pye D: Assessment of corneal biomechanical properties and their variation with age. Curr Eye Res. 2007, 32 (1): 11-19. 10.1080/02713680601077145.CrossRefPubMed
20.
go back to reference Knox Cartwright NE, Tyrer JR, Marshall J: Age-related differences in the elasticity of the human cornea. Invest Ophthalmol Vis Sci. 2011, 52 (7): 4324-4329. 10.1167/iovs.09-4798.CrossRefPubMed Knox Cartwright NE, Tyrer JR, Marshall J: Age-related differences in the elasticity of the human cornea. Invest Ophthalmol Vis Sci. 2011, 52 (7): 4324-4329. 10.1167/iovs.09-4798.CrossRefPubMed
21.
go back to reference Lau W, Pye D: A clinical description of Ocular Response Analyser measurements. Invest Ophthalmol Vis Sci. 2011, 52 (6): 2911-2916. 10.1167/iovs.10-6763.CrossRefPubMed Lau W, Pye D: A clinical description of Ocular Response Analyser measurements. Invest Ophthalmol Vis Sci. 2011, 52 (6): 2911-2916. 10.1167/iovs.10-6763.CrossRefPubMed
22.
go back to reference Narayanaswamy A, Chung RS, Wu RY, Park J, Wong WL, Saw SM, Wong TY, Aung T: Determinants of corneal biomechanical properties in an adult chinese population. Ophthalmology. 2011, 118 (7): 1253-1259.PubMed Narayanaswamy A, Chung RS, Wu RY, Park J, Wong WL, Saw SM, Wong TY, Aung T: Determinants of corneal biomechanical properties in an adult chinese population. Ophthalmology. 2011, 118 (7): 1253-1259.PubMed
23.
go back to reference Lim L, Gazzard G, Chan YH, Fong A, Kotecha A, Sim EL, Tan D, Tong L, Saw SM: Cornea biomechanical characteristics and their correlates with refractive error in Singaporean children. Invest Ophthalmol Vis Sci. 2008, 49 (9): 3852-3857. 10.1167/iovs.07-1670.CrossRefPubMed Lim L, Gazzard G, Chan YH, Fong A, Kotecha A, Sim EL, Tan D, Tong L, Saw SM: Cornea biomechanical characteristics and their correlates with refractive error in Singaporean children. Invest Ophthalmol Vis Sci. 2008, 49 (9): 3852-3857. 10.1167/iovs.07-1670.CrossRefPubMed
24.
go back to reference Methodology For Corneal Compensated Iop And Corneal Resistance Factor For An Ocular Response Analyzer. Invest Ophthalmol Vis Sci. 2006, 47: E-Abstract 2266- Methodology For Corneal Compensated Iop And Corneal Resistance Factor For An Ocular Response Analyzer. Invest Ophthalmol Vis Sci. 2006, 47: E-Abstract 2266-
25.
go back to reference Fontes BM, Ambrosio R, Alonso RS, Jardim D, Velarde GC, Nose W: Corneal biomechanical metrics in eyes with refraction of -19.00 to +9.00 D in healthy Brazilian patients. J Refract Surg. 2008, 24 (9): 941-945.PubMed Fontes BM, Ambrosio R, Alonso RS, Jardim D, Velarde GC, Nose W: Corneal biomechanical metrics in eyes with refraction of -19.00 to +9.00 D in healthy Brazilian patients. J Refract Surg. 2008, 24 (9): 941-945.PubMed
26.
go back to reference Chang PY, Chang SW, Wang JY: Assessment of corneal biomechanical properties and intraocular pressure with the Ocular Response Analyzer in childhood myopia. Br J Ophthalmol. 2010, 94 (7): 877-881. 10.1136/bjo.2009.158568.CrossRefPubMed Chang PY, Chang SW, Wang JY: Assessment of corneal biomechanical properties and intraocular pressure with the Ocular Response Analyzer in childhood myopia. Br J Ophthalmol. 2010, 94 (7): 877-881. 10.1136/bjo.2009.158568.CrossRefPubMed
27.
go back to reference McBrien NA, Jobling AI, Gentle A: Biomechanics of the sclera in myopia: extracellular and cellular factors. Optom Vis Sci. 2009, 86 (1): E23-E30. 10.1097/OPX.0b013e3181940669.CrossRefPubMed McBrien NA, Jobling AI, Gentle A: Biomechanics of the sclera in myopia: extracellular and cellular factors. Optom Vis Sci. 2009, 86 (1): E23-E30. 10.1097/OPX.0b013e3181940669.CrossRefPubMed
28.
go back to reference Kotecha A, Crabb DP, Spratt A, Garway-Heath DF: The relationship between diurnal variations in intraocular pressure measurements and central corneal thickness and corneal hysteresis. Invest Ophthalmol Vis Sci. 2009, 50 (9): 4229-4236. 10.1167/iovs.08-2955.CrossRefPubMed Kotecha A, Crabb DP, Spratt A, Garway-Heath DF: The relationship between diurnal variations in intraocular pressure measurements and central corneal thickness and corneal hysteresis. Invest Ophthalmol Vis Sci. 2009, 50 (9): 4229-4236. 10.1167/iovs.08-2955.CrossRefPubMed
29.
go back to reference Elsheikh A, Wang D, Rama P, Campanelli M, Garway-Heath D: Experimental assessment of human corneal hysteresis. Curr Eye Res. 2008, 33 (3): 205-213. 10.1080/02713680701882519.CrossRefPubMed Elsheikh A, Wang D, Rama P, Campanelli M, Garway-Heath D: Experimental assessment of human corneal hysteresis. Curr Eye Res. 2008, 33 (3): 205-213. 10.1080/02713680701882519.CrossRefPubMed
30.
go back to reference Mikielewicz M, Kotliar K, Barraquer RI, Michael R: Air-pulse corneal applanation signal curve parameters for the characterisation of keratoconus. Br J Ophthalmol. 2011, 95 (6): 793-798. 10.1136/bjo.2010.188300.CrossRefPubMed Mikielewicz M, Kotliar K, Barraquer RI, Michael R: Air-pulse corneal applanation signal curve parameters for the characterisation of keratoconus. Br J Ophthalmol. 2011, 95 (6): 793-798. 10.1136/bjo.2010.188300.CrossRefPubMed
31.
go back to reference Kerautret J, Colin J, Touboul D, Roberts C: Biomechanical characteristics of the ectatic cornea. J Cataract Refract Surg. 2008, 34 (3): 510-513. 10.1016/j.jcrs.2007.11.018.CrossRefPubMed Kerautret J, Colin J, Touboul D, Roberts C: Biomechanical characteristics of the ectatic cornea. J Cataract Refract Surg. 2008, 34 (3): 510-513. 10.1016/j.jcrs.2007.11.018.CrossRefPubMed
Metadata
Title
Biomechanical parameters of the cornea measured with the Ocular Response Analyzer in normal eyes
Authors
Aachal Kotecha
Richard A Russell
Angelos Sinapis
Sayeh Pourjavan
Dimitros Sinapis
David F Garway-Heath
Publication date
01-12-2014
Publisher
BioMed Central
Published in
BMC Ophthalmology / Issue 1/2014
Electronic ISSN: 1471-2415
DOI
https://doi.org/10.1186/1471-2415-14-11

Other articles of this Issue 1/2014

BMC Ophthalmology 1/2014 Go to the issue