Skip to main content
Top
Published in: BMC Musculoskeletal Disorders 1/2020

Open Access 01-12-2020 | Research article

Biomechanical comparison of three minimally invasive fixations for unilateral pubic rami fractures

Authors: Yong Zhao, Yupeng Ma, Dexin Zou, Xiujiang Sun, Gong Cheng, Wei Lian, Shengjie Dong, Yuchi Zhao, Wenqing Qu, Hao Wu

Published in: BMC Musculoskeletal Disorders | Issue 1/2020

Login to get access

Abstract

Background

To compare the mechanical characteristics of a percutaneous superior pubic intramedullary screw, percutaneous bridging plate and percutaneous screw-rod system of the anterior ring for the treatment of unilateral vertical pubic fractures to provide a reference for clinical application.

Methods

A finite element model of pelvic anterior ring injury (unilateral vertical pubic fracture) was produced. The fractures were fixed with a percutaneous superior pubic intramedullary screw, percutaneous bridging plate and percutaneous screw-rod system of the anterior ring and their combinations in 5 types of models. The fracture stabilities under vertical, bilateral and anterior-posterior load were quantified and compared based on the displacement of the hip joints’ midpoint as quantificational index of fracture stability.

Results

In the condition of bilateral and anterior-posterior load, the vertical, bilateral and anterior-posterior displacements of the hip joints’ midpoint of different models were significantly different respectively. In general, the displacements of the 5 pelvic anterior ring fixations were ranked from maximum to minimum as follows: bridging plate, pelvic anterior screw-rod system, combination of bridging plate and pelvic anterior screw-rod system, superior pubic intramedullary screw and combination of superior pubic intramedullary screw and pelvic anterior screw-rod system.

Conclusion

For the fixation in unilateral pubic fractures of pelvic ring injury, the percutaneous superior pubic intramedullary screw is optimal, the percutaneous pelvic anterior screw-rod system is the second choice, and percutaneous bridging plate ranks the third. The percutaneous pelvic anterior screw-rod system can significantly increase fixation stability of the percutaneous superior pubic intramedullary screw and the percutaneous bridging plate.
Literature
1.
go back to reference Zhao Y, Li J, Wang D, Liu Y, Tan J, Zhang S. Comparison of stability of two kinds of sacro-iliac screws in the fixation of bilateral sacral fractures in a finite element model. Injury. 2012;43:490–4.CrossRef Zhao Y, Li J, Wang D, Liu Y, Tan J, Zhang S. Comparison of stability of two kinds of sacro-iliac screws in the fixation of bilateral sacral fractures in a finite element model. Injury. 2012;43:490–4.CrossRef
2.
go back to reference Zhao Y, Zhang S, Sun T, Wang D, Lian W, Tan J, Zou D, Zhao Y. Mechanical comparison between lengthened and short sacroiliac screws in sacral fracture fixation: a finite element analysis. Orthop Traumatol Surg Res. 2013;99:601–6.CrossRef Zhao Y, Zhang S, Sun T, Wang D, Lian W, Tan J, Zou D, Zhao Y. Mechanical comparison between lengthened and short sacroiliac screws in sacral fracture fixation: a finite element analysis. Orthop Traumatol Surg Res. 2013;99:601–6.CrossRef
3.
go back to reference Wojahn RD, Gardner MJ. Fixation of Anterior Pelvic Ring Injuries. J Am Acad Orthop Surg. 2019;27:667–76.CrossRef Wojahn RD, Gardner MJ. Fixation of Anterior Pelvic Ring Injuries. J Am Acad Orthop Surg. 2019;27:667–76.CrossRef
4.
go back to reference Fu S, Zhao Y, Lian W, Zou D, Sun T, Zhao Y, Tan J, Zhang S, Wang D. Comparison of the risk of breakage of two kinds of sacroiliac screws in the treatment of bilateral sacral fractures. Eur Spine J. 2014;23:1558–67.CrossRef Fu S, Zhao Y, Lian W, Zou D, Sun T, Zhao Y, Tan J, Zhang S, Wang D. Comparison of the risk of breakage of two kinds of sacroiliac screws in the treatment of bilateral sacral fractures. Eur Spine J. 2014;23:1558–67.CrossRef
5.
go back to reference Chui KH, Chan CCD, Ip KC, Lee KB, Li W. Three-dimensional navigation-guided percutaneous screw fixation for nondisplaced and displaced pelvi-acetabular fractures in a major trauma centre. Int Orthop. 2018;42:1387–95.CrossRef Chui KH, Chan CCD, Ip KC, Lee KB, Li W. Three-dimensional navigation-guided percutaneous screw fixation for nondisplaced and displaced pelvi-acetabular fractures in a major trauma centre. Int Orthop. 2018;42:1387–95.CrossRef
6.
go back to reference Eckardt H, Egger A, Hasler RM, Zech CJ, Vach W, Suhm N, Morgenstern M, Saxer F. Good functional outcome in patients suffering fragility fractures of the pelvis treated with percutaneous screw stabilisation: assessment of complications and factors influencing failure. Injury. 2017;48:2717–23.CrossRef Eckardt H, Egger A, Hasler RM, Zech CJ, Vach W, Suhm N, Morgenstern M, Saxer F. Good functional outcome in patients suffering fragility fractures of the pelvis treated with percutaneous screw stabilisation: assessment of complications and factors influencing failure. Injury. 2017;48:2717–23.CrossRef
7.
go back to reference Fang C, Alabdulrahman H, Pape HC. Complications after percutaneous internal fixator for anterior pelvic ring injuries. Int Orthop. 2017;41:1785–90.CrossRef Fang C, Alabdulrahman H, Pape HC. Complications after percutaneous internal fixator for anterior pelvic ring injuries. Int Orthop. 2017;41:1785–90.CrossRef
8.
go back to reference Suzuki T, Soma K, Shindo M, Minehara H, Itoman M. Anatomic study for pubic medullary screw insertion. J Orthop Surg. 2008;16:321–5.CrossRef Suzuki T, Soma K, Shindo M, Minehara H, Itoman M. Anatomic study for pubic medullary screw insertion. J Orthop Surg. 2008;16:321–5.CrossRef
9.
go back to reference Weatherby DJ, Chip Routt ML, Eastman JG. The Retrograde-Antegrade-Retrograde Technique for Successful Placement of a Retrograde Superior Ramus Screw. J Orthop Trauma. 2017;31:e224–9.CrossRef Weatherby DJ, Chip Routt ML, Eastman JG. The Retrograde-Antegrade-Retrograde Technique for Successful Placement of a Retrograde Superior Ramus Screw. J Orthop Trauma. 2017;31:e224–9.CrossRef
10.
go back to reference Vaidya R, Colen R, Vigdorchik J, Tonnos F, Sethi A. Treatment of unstable pelvic ring injuries with an internal anterior fixator and posterior fixation: initial clinical series. J Orthop Trauma. 2012;26:1–8.CrossRef Vaidya R, Colen R, Vigdorchik J, Tonnos F, Sethi A. Treatment of unstable pelvic ring injuries with an internal anterior fixator and posterior fixation: initial clinical series. J Orthop Trauma. 2012;26:1–8.CrossRef
11.
go back to reference Jordan MC, Brems AC, Heintel T, Jansen H, Hoelscher-Doht S, Meffert RH. The Anterior Subcutaneous Pelvic Ring Fixator: No Biomechanical Advantages Compared with External Fixation. J Bone Joint Surg Am. 2019;101:1724–31.CrossRef Jordan MC, Brems AC, Heintel T, Jansen H, Hoelscher-Doht S, Meffert RH. The Anterior Subcutaneous Pelvic Ring Fixator: No Biomechanical Advantages Compared with External Fixation. J Bone Joint Surg Am. 2019;101:1724–31.CrossRef
12.
go back to reference Vaidya R, Kubiak EN, Bergin PF, Dombroski DG, Critchlow RJ, Sethi A, Starr AJ. Complications of anterior subcutaneous internal fixation for unstable pelvis fractures: a multicenter study. Clin Orthop Relat Res. 2012;470:2124–31.CrossRef Vaidya R, Kubiak EN, Bergin PF, Dombroski DG, Critchlow RJ, Sethi A, Starr AJ. Complications of anterior subcutaneous internal fixation for unstable pelvis fractures: a multicenter study. Clin Orthop Relat Res. 2012;470:2124–31.CrossRef
Metadata
Title
Biomechanical comparison of three minimally invasive fixations for unilateral pubic rami fractures
Authors
Yong Zhao
Yupeng Ma
Dexin Zou
Xiujiang Sun
Gong Cheng
Wei Lian
Shengjie Dong
Yuchi Zhao
Wenqing Qu
Hao Wu
Publication date
01-12-2020
Publisher
BioMed Central
Published in
BMC Musculoskeletal Disorders / Issue 1/2020
Electronic ISSN: 1471-2474
DOI
https://doi.org/10.1186/s12891-020-03604-8

Other articles of this Issue 1/2020

BMC Musculoskeletal Disorders 1/2020 Go to the issue