Abstract

Background

Many types of titanium plates were used to treat subcondylar fracture clinically. However, the efficacy of fixation in different implant positions and lengths of the bone plate has not been thoroughly investigated. Therefore, the primary purpose of this study was to use finite element analysis (FEA) to analyze the biomechanical effects of subcondylar fracture fixation with miniplates at different positions and lengths so that clinicians were able to find a better strategy of fixation to improve the efficacy and outcome of treatment.

Methods

The CAD software was used to combine the mandible, miniplate, and screw to create seven different FEA computer models. These models with subcondylar fracture were fixed with miniplates at different positions and of different lengths. The right unilateral molar clench occlusal mode was applied. The observational indicators were the reaction force at the temporomandibular joint, von Mises stress of the mandibular bone, miniplate and screw, and the sliding distance on the oblique surface of the fracture site at the mandibular condyle.

Results

The results showed the efficacy of fixation was better when two miniplates were used comparing to only one miniplates. Moreover, using longer miniplates for fixation had better results than the short one. Furthermore, fixing miniplates at the posterior portion of subcondylar region would have a better fixation efficacy and less sliding distance (5.46–5.76 μm) than fixing at the anterolateral surface of subcondylar region (6.10–7.00 μm).

Conclusion

Miniplate fixation, which was placed closer to the posterior margin, could effectively reduce the amount of sliding distance in the fracture site, thereby achieving greater stability. Furthermore, fixation efficiency was improved when an additional miniplate was placed at the anterior margin. Our study suggested that the placement of miniplates at the posterior surface and the additional plate could effectively improve stability.
Literature
1.
go back to reference Lin F-Y, Wu C-I, Cheng H-T. Mandibular fracture patterns at a medical center in central Taiwan: a 3-year epidemiological review. Medicine. 2017;96:e9333.CrossRef Lin F-Y, Wu C-I, Cheng H-T. Mandibular fracture patterns at a medical center in central Taiwan: a 3-year epidemiological review. Medicine. 2017;96:e9333.CrossRef
2.
go back to reference Simsek S, Simsek B, Abubaker A, Laskin D. A comparative study of mandibular fractures in the United States and Turkey. Int J Oral Maxillofac Surg. 2007;36:395–7.CrossRef Simsek S, Simsek B, Abubaker A, Laskin D. A comparative study of mandibular fractures in the United States and Turkey. Int J Oral Maxillofac Surg. 2007;36:395–7.CrossRef
3.
go back to reference Bormann K-H, Wild S, Gellrich N-C, Kokemüller H, Stühmer C, Schmelzeisen R, Schön R. Five-year retrospective study of mandibular fractures in Freiburg, Germany: incidence, etiology, treatment, and complications. J Oral Maxillofac Surg. 2009;67:1251–5.CrossRef Bormann K-H, Wild S, Gellrich N-C, Kokemüller H, Stühmer C, Schmelzeisen R, Schön R. Five-year retrospective study of mandibular fractures in Freiburg, Germany: incidence, etiology, treatment, and complications. J Oral Maxillofac Surg. 2009;67:1251–5.CrossRef
4.
go back to reference Hammer B, Schier P, Prein J. Osteosynthesis of condylar neck fractures: a review of 30 patients. Br J Oral Maxillofac Surg. 1997;35:288–91.CrossRef Hammer B, Schier P, Prein J. Osteosynthesis of condylar neck fractures: a review of 30 patients. Br J Oral Maxillofac Surg. 1997;35:288–91.CrossRef
5.
go back to reference Asim MA, Ibrahim MW, Javed MU, Zahra R, Qayyum MU. Functional outcomes of open versus closed treatment of unilateral mandibular condylar fractures. J Ayub Med Coll Abbottabad. 2019;31:67–71.PubMed Asim MA, Ibrahim MW, Javed MU, Zahra R, Qayyum MU. Functional outcomes of open versus closed treatment of unilateral mandibular condylar fractures. J Ayub Med Coll Abbottabad. 2019;31:67–71.PubMed
6.
go back to reference Yao S, Zhou J, Li Z. Contrast analysis of open reduction and internal fixation and non-surgical treatment of condylar fracture: a meta-analysis. J Craniofac Surg. 2014;25:2077–80.CrossRef Yao S, Zhou J, Li Z. Contrast analysis of open reduction and internal fixation and non-surgical treatment of condylar fracture: a meta-analysis. J Craniofac Surg. 2014;25:2077–80.CrossRef
7.
go back to reference Worsaae N, Thorn JJ. Surgical versus nonsurgical treatment of unilateral dislocated low subcondylar fractures: a clinical study of 52 cases. J Oral Maxillofac Surg. 1994;52:353–60.CrossRef Worsaae N, Thorn JJ. Surgical versus nonsurgical treatment of unilateral dislocated low subcondylar fractures: a clinical study of 52 cases. J Oral Maxillofac Surg. 1994;52:353–60.CrossRef
8.
go back to reference Choi B-H, Yi C-K, Yoo J-H. Clinical evaluation of 3 types of plate osteosynthesis for fixation of condylar neck fractures. J Oral Maxillofac Surg. 2001;59:734–7.CrossRef Choi B-H, Yi C-K, Yoo J-H. Clinical evaluation of 3 types of plate osteosynthesis for fixation of condylar neck fractures. J Oral Maxillofac Surg. 2001;59:734–7.CrossRef
9.
go back to reference Marwan H, Sawatari Y. What is the most stable fixation technique for mandibular condyle fracture? J Oral Maxillofac Surg. 2019;77(2522):e1–12. Marwan H, Sawatari Y. What is the most stable fixation technique for mandibular condyle fracture? J Oral Maxillofac Surg. 2019;77(2522):e1–12.
10.
go back to reference Çimen E, Önder ME, Cambazoglu M, Birant E. Comparison of different fixation types used in unilateral mandibular condylar fractures: an in vivo study with new biomechanical model. J Craniofac Surg. 2016;27:1277–81.CrossRef Çimen E, Önder ME, Cambazoglu M, Birant E. Comparison of different fixation types used in unilateral mandibular condylar fractures: an in vivo study with new biomechanical model. J Craniofac Surg. 2016;27:1277–81.CrossRef
11.
go back to reference Kozakiewicz M, Swiniarski J. “A” shape plate for open rigid internal fixation of mandible condyle neck fracture. J Craniomaxillofac Surg. 2014;42:730–7.CrossRef Kozakiewicz M, Swiniarski J. “A” shape plate for open rigid internal fixation of mandible condyle neck fracture. J Craniomaxillofac Surg. 2014;42:730–7.CrossRef
12.
go back to reference Conci RA, Tomazi FH, Noritomi PY, da Silva JV, Fritscher GG, Heitz C. Comparison of neck screw and conventional fixation techniques in mandibular condyle fractures using 3-dimensional finite element analysis. J Oral Maxillofac Surg. 2015;73:1321–7.CrossRef Conci RA, Tomazi FH, Noritomi PY, da Silva JV, Fritscher GG, Heitz C. Comparison of neck screw and conventional fixation techniques in mandibular condyle fractures using 3-dimensional finite element analysis. J Oral Maxillofac Surg. 2015;73:1321–7.CrossRef
13.
go back to reference Hijazi L, Hejazi W, Darwich MA, Darwich K. Finite element analysis of stress distribution on the mandible and condylar fracture osteosynthesis during various clenching tasks. Oral maxillofac surg. 2016;20:359–67.CrossRef Hijazi L, Hejazi W, Darwich MA, Darwich K. Finite element analysis of stress distribution on the mandible and condylar fracture osteosynthesis during various clenching tasks. Oral maxillofac surg. 2016;20:359–67.CrossRef
14.
go back to reference Aquilina P, Parr WC, Chamoli U, Wroe S, Clausen P. A biomechanical comparison of three 1.5-mm plate and screw configurations and a single 2.0-mm plate for internal fixation of a mandibular condylar fracture. Craniomaxillofac Trauma Reconstr. 2014; 7:218–23. Aquilina P, Parr WC, Chamoli U, Wroe S, Clausen P. A biomechanical comparison of three 1.5-mm plate and screw configurations and a single 2.0-mm plate for internal fixation of a mandibular condylar fracture. Craniomaxillofac Trauma Reconstr. 2014; 7:218–23.
15.
go back to reference Luo D, Rong Q, Chen Q. Finite-element design and optimization of a three-dimensional tetrahedral porous titanium scaffold for the reconstruction of mandibular defects. Medl Eng Phys. 2017;47:176–83.CrossRef Luo D, Rong Q, Chen Q. Finite-element design and optimization of a three-dimensional tetrahedral porous titanium scaffold for the reconstruction of mandibular defects. Medl Eng Phys. 2017;47:176–83.CrossRef
16.
go back to reference Huang H-L, Su K-C, Fuh L-J, Chen MY, Wu J, Tsai M-T, Hsu J-T. Biomechanical analysis of a temporomandibular joint condylar prosthesis during various clenching tasks. J Craniomaxillofac Surg. 2015;43:1194–201.CrossRef Huang H-L, Su K-C, Fuh L-J, Chen MY, Wu J, Tsai M-T, Hsu J-T. Biomechanical analysis of a temporomandibular joint condylar prosthesis during various clenching tasks. J Craniomaxillofac Surg. 2015;43:1194–201.CrossRef
17.
go back to reference Lee HH. Finite element simulations with ANSYS workbench 15, Chuan Hwa Book Co. 2014. Lee HH. Finite element simulations with ANSYS workbench 15, Chuan Hwa Book Co. 2014.
18.
go back to reference Chen Y-N, Chang C-W, Lin C-W, Wang C-W, Peng Y-T, Chang C-H, Li C-T. Numerical investigation of fracture impaction in proximal humeral fracture fixation with locking plate and intramedullary nail. Int orthop. 2017;41:1471–80.CrossRef Chen Y-N, Chang C-W, Lin C-W, Wang C-W, Peng Y-T, Chang C-H, Li C-T. Numerical investigation of fracture impaction in proximal humeral fracture fixation with locking plate and intramedullary nail. Int orthop. 2017;41:1471–80.CrossRef
19.
go back to reference Chang YH, Chan MY, Hsu JT, Hsiao HY, Su KC. Biomechanical analysis of the forces exerted during different occlusion conditions following bilateral sagittal split osteotomy treatment for mandibular deficiency. Appl Bionics Biomech. 2019. https://doi.org/10.1155/2019/4989013. Chang YH, Chan MY, Hsu JT, Hsiao HY, Su KC. Biomechanical analysis of the forces exerted during different occlusion conditions following bilateral sagittal split osteotomy treatment for mandibular deficiency. Appl Bionics Biomech. 2019. https://​doi.​org/​10.​1155/​2019/​4989013.
20.
go back to reference Su K-C, Chang C-H, Chuang S-F, Ng E. Biomechanical evaluation of endodontic post-restored teeth—finite element analysis. J Mech Med Biol. 2013;13:1350012.CrossRef Su K-C, Chang C-H, Chuang S-F, Ng E. Biomechanical evaluation of endodontic post-restored teeth—finite element analysis. J Mech Med Biol. 2013;13:1350012.CrossRef
21.
go back to reference Darwich MA, Albogha MH, Abdelmajeed A, Darwich K. Assessment of the biomechanical performance of 5 plating techniques in fixation of mandibular subcondylar fracture using finite element analysis. J Oral Maxillofac Surg. 2016;74(794):e791–8. Darwich MA, Albogha MH, Abdelmajeed A, Darwich K. Assessment of the biomechanical performance of 5 plating techniques in fixation of mandibular subcondylar fracture using finite element analysis. J Oral Maxillofac Surg. 2016;74(794):e791–8.
22.
go back to reference Champy M, Loddé JP, Schmitt R, Jaeger JH, Muster D. Mandibular osteosynthesis by miniature screwed plates via a buccal approach. J Maxillofac Surg. 1978;6:14–21.CrossRef Champy M, Loddé JP, Schmitt R, Jaeger JH, Muster D. Mandibular osteosynthesis by miniature screwed plates via a buccal approach. J Maxillofac Surg. 1978;6:14–21.CrossRef
23.
go back to reference Aquilina P, Chamoli U, Parr WC, Clausen PD, Wroe S. Finite element analysis of three patterns of internal fixation of fractures of the mandibular condyle. Br J Oral Maxillofac Surg. 2013;51:326–31.CrossRef Aquilina P, Chamoli U, Parr WC, Clausen PD, Wroe S. Finite element analysis of three patterns of internal fixation of fractures of the mandibular condyle. Br J Oral Maxillofac Surg. 2013;51:326–31.CrossRef
24.
go back to reference Murakami K, Yamamoto K, Sugiura T, Horita S, Matsusue Y, Kirita T. Computed tomography-based 3-dimensional finite element analyses of various types of plates placed for a virtually reduced unilateral condylar fracture of the mandible of a patient. J Oral Maxillofac Surg. 2017;75(1239):e1-11. Murakami K, Yamamoto K, Sugiura T, Horita S, Matsusue Y, Kirita T. Computed tomography-based 3-dimensional finite element analyses of various types of plates placed for a virtually reduced unilateral condylar fracture of the mandible of a patient. J Oral Maxillofac Surg. 2017;75(1239):e1-11.
25.
go back to reference Lauer G, Haim D, Proff P, Richter G, Pradel W, Fanghänel J, Pilling E, Gedrange T, Mai R. Plate osteosynthesis of the mandibular condyle. Ann Anat. 2007;189:412–7.CrossRef Lauer G, Haim D, Proff P, Richter G, Pradel W, Fanghänel J, Pilling E, Gedrange T, Mai R. Plate osteosynthesis of the mandibular condyle. Ann Anat. 2007;189:412–7.CrossRef
26.
go back to reference Kurtadikar K, Singhvi N, Shetty JN, Shetye O, Islam M, Keerthy H. Evaluation of mechanical resistance after fixation of mandibular condylar fracture with single and double miniplates: a comparative in vitro study. J maxillofac oral surg. 2015;14:441–7.CrossRef Kurtadikar K, Singhvi N, Shetty JN, Shetye O, Islam M, Keerthy H. Evaluation of mechanical resistance after fixation of mandibular condylar fracture with single and double miniplates: a comparative in vitro study. J maxillofac oral surg. 2015;14:441–7.CrossRef
27.
go back to reference Huang H-L, Tsai M-T, Yang S-G, Su K-C, Shen Y-W, Hsu J-T. Mandible integrity and material properties of the periodontal ligament during orthodontic tooth movement: a finite-element study. Appl Sci. 2020;10:2980.CrossRef Huang H-L, Tsai M-T, Yang S-G, Su K-C, Shen Y-W, Hsu J-T. Mandible integrity and material properties of the periodontal ligament during orthodontic tooth movement: a finite-element study. Appl Sci. 2020;10:2980.CrossRef
28.
go back to reference Kurtadikar K, Singhvi N, Shetty JN, Shetye O, Islam M, Keerthy H. Evaluation of mechanical resistance after fixation of mandibular condylar fracture with single and double miniplates: a comparative in vitro study. J Maxillofacial Oral Surg. 2015;14:441–7.CrossRef Kurtadikar K, Singhvi N, Shetty JN, Shetye O, Islam M, Keerthy H. Evaluation of mechanical resistance after fixation of mandibular condylar fracture with single and double miniplates: a comparative in vitro study. J Maxillofacial Oral Surg. 2015;14:441–7.CrossRef
Metadata
Title
Biomechanical analysis of subcondylar fracture fixation using miniplates at different positions and of different lengths
Authors
Chao-Min Huang
Man-Yee Chan
Jui-Ting Hsu
Kuo-Chih Su
Publication date
01-12-2021
Publisher
BioMed Central
Published in
BMC Oral Health / Issue 1/2021
Electronic ISSN: 1472-6831
DOI
https://doi.org/10.1186/s12903-021-01905-5

Other articles of this Issue 1/2021

BMC Oral Health 1/2021 Go to the issue