Abstract

Compared to bicortical screws, the surgical risk of injuring intraspinal structures can be minimized with the use of monocortical screws. However, this reduction should not be achieved at the expense of the stability of the fixation. With monocortical stabilization, the expansion screws have the potential of absorbing high loads. Therefore, they are expected to be a suitable alternative to bicortical screws for revision surgeries and in osteoporotic bone. The purpose of this in vitro study was to investigate the stiffness of the two screw-plate systems used for ventral stabilization of the cervical spine, by focusing on the suitability of expansion screws as tools for revision treatments. The study was conducted in ten functional units of human cervical spines. The device sample stiffness was determined for four conditions using a turning moment of 2.25 N m each around one of the three principle axes. The conditions were native, destabilized, primarily stabilized with one of the screw-plate systems, followed by secondary stabilization using the expansion screw implant. The stabilized samples achieved a comparable, in most cases higher stiffness than the native samples. The samples undergoing secondary stabilization using expansion screws tend to display greater stiffness for all three axes compared to the primarily stabilized samples. The achieved tightening moment of the screws was higher than the one achieved with primary fixation. Both plates revealed similar primary stability. Revision surgeries with secondary instrumentation achieve a high stiffness of the screwed up segments. Monocortical expansion screws combined with a trapezoidal plate allow ventral stabilization of the cervical spine that is comparable to the plate fixation using bicortical screws.
Literature
1.
go back to reference Bailey RW, Badgley CE, Arbor A (1960) Stabilization of the cervical spine by anterior fusion. J Bone Joint Surg Am 42-A:565–594PubMed Bailey RW, Badgley CE, Arbor A (1960) Stabilization of the cervical spine by anterior fusion. J Bone Joint Surg Am 42-A:565–594PubMed
2.
go back to reference Blauth M, Schmidt U, Bastian L, Knop C, Tscherne H (1998) Die ventrale interkorporelle Spondylodese bei Verletzungen der Halswirbelsäule Indikationen. Operationstechnik Ergeb Zentralbl Chir 123:919–929 Blauth M, Schmidt U, Bastian L, Knop C, Tscherne H (1998) Die ventrale interkorporelle Spondylodese bei Verletzungen der Halswirbelsäule Indikationen. Operationstechnik Ergeb Zentralbl Chir 123:919–929
3.
go back to reference Böhler J, Gaudernak T (1980) Anterior plate stabilisation for fracture-dislocations of the lower cervical spine. J Trauma 20:203–205PubMedCrossRef Böhler J, Gaudernak T (1980) Anterior plate stabilisation for fracture-dislocations of the lower cervical spine. J Trauma 20:203–205PubMedCrossRef
4.
go back to reference Bühren V (2002) Frakturen Instabilitaten Halswirbelsaule. Unfallchirurg 73:1049–1066 Bühren V (2002) Frakturen Instabilitaten Halswirbelsaule. Unfallchirurg 73:1049–1066
6.
go back to reference Clausen JD, Ryken TC, Traynelis VC, Sawin PD, Dexter F, Goel VK (1996) Biomechanical evaluation of the Caspar and cervical spine locking plate system in a cadaveric model. J Neurosurg 84:1039–1045PubMedCrossRef Clausen JD, Ryken TC, Traynelis VC, Sawin PD, Dexter F, Goel VK (1996) Biomechanical evaluation of the Caspar and cervical spine locking plate system in a cadaveric model. J Neurosurg 84:1039–1045PubMedCrossRef
7.
8.
go back to reference Cloward RB (1961) Treatment of acute fractures and fracture-dislocations of the cervical spine by vertebral-body fusion. J Neurosurg 18:201–209PubMedCrossRef Cloward RB (1961) Treatment of acute fractures and fracture-dislocations of the cervical spine by vertebral-body fusion. J Neurosurg 18:201–209PubMedCrossRef
11.
go back to reference Hattori S, Oda H, Kawai S (1981) Ube-Shi: cervical intradiscal pressure in movements and traction of the cervical spine. Z Orthop 119:568–569 Hattori S, Oda H, Kawai S (1981) Ube-Shi: cervical intradiscal pressure in movements and traction of the cervical spine. Z Orthop 119:568–569
13.
go back to reference Hofmeister M, Bühren V (1999) Therapiekonzepte für Verletzungen der unteren. HWS Orthopäde 28:401–413 Hofmeister M, Bühren V (1999) Therapiekonzepte für Verletzungen der unteren. HWS Orthopäde 28:401–413
14.
go back to reference Kurth AA, Pfeilschifter J (2007) Diagnostik und Therapie der postmenopausalen Osteoporose und der Osteoporose des Mannes Orthopäde. 36:683–692 Kurth AA, Pfeilschifter J (2007) Diagnostik und Therapie der postmenopausalen Osteoporose und der Osteoporose des Mannes Orthopäde. 36:683–692
15.
go back to reference Kalff R, Ulrich C, Claes L, Wilke HJ, Grote W (1992) Comparative experimental biomechanical study of different types of stabilization methods of the lower cervical spine. Neurosurg Rev 15:259–264. doi:10.1007/BF00345928 PubMedCrossRef Kalff R, Ulrich C, Claes L, Wilke HJ, Grote W (1992) Comparative experimental biomechanical study of different types of stabilization methods of the lower cervical spine. Neurosurg Rev 15:259–264. doi:10.​1007/​BF00345928 PubMedCrossRef
18.
go back to reference Morscher E, Sutter F, Jenny H, Olerud S (1986) Die vordere Verplattung der Halswirbelsäule mit dem. Hohlschrauben-Plattensystem aus Titanium Chirurg 57:702–707 Morscher E, Sutter F, Jenny H, Olerud S (1986) Die vordere Verplattung der Halswirbelsäule mit dem. Hohlschrauben-Plattensystem aus Titanium Chirurg 57:702–707
20.
go back to reference Orozco RD, Llovet JT (1970) Osteosintesis en las fracturas de raquis cervical. Nota de tecnica Revista de Ortopedia y Traumatologia 14:285–288 Orozco RD, Llovet JT (1970) Osteosintesis en las fracturas de raquis cervical. Nota de tecnica Revista de Ortopedia y Traumatologia 14:285–288
23.
go back to reference Ryken TC, Clausen JD, Traynelis VC, Goel VK (1995) Biomechanical analysis of bone mineral density, insertion technique, screw torque and holding strength of anterior cervical plate screws. J Neurosurg 83:324–329CrossRef Ryken TC, Clausen JD, Traynelis VC, Goel VK (1995) Biomechanical analysis of bone mineral density, insertion technique, screw torque and holding strength of anterior cervical plate screws. J Neurosurg 83:324–329CrossRef
24.
go back to reference Smith GW, Robinson RA (1958) The treatment of cervical-spine disorders by anterior removal of the intervertebral disc and interbody fusion. J Bone Joint Surg 40-A:607–624PubMed Smith GW, Robinson RA (1958) The treatment of cervical-spine disorders by anterior removal of the intervertebral disc and interbody fusion. J Bone Joint Surg 40-A:607–624PubMed
27.
go back to reference Ulrich C, Arand M (1993) Stellenwert biomechanischer Untersuchungsverfahren für die klinische Anwendung ventraler und dorsaler HWS-Fixationssysteme. In: Matzen KA (ed) Die operative Behandlung der Halswirbelsäule. Zuckschwerdt, Muchen Bern Vienna, pp 26–34 Ulrich C, Arand M (1993) Stellenwert biomechanischer Untersuchungsverfahren für die klinische Anwendung ventraler und dorsaler HWS-Fixationssysteme. In: Matzen KA (ed) Die operative Behandlung der Halswirbelsäule. Zuckschwerdt, Muchen Bern Vienna, pp 26–34
28.
go back to reference Ulrich C, Nothwang J (1999) Biomechanik und Klinik der Spondylodese an der unteren HWS. Orthopäde 28:637–650PubMed Ulrich C, Nothwang J (1999) Biomechanik und Klinik der Spondylodese an der unteren HWS. Orthopäde 28:637–650PubMed
30.
go back to reference Wilke HJ, Wenger K, Claes LE (1998) Testing criteria for spinal implants: recommendations for the standardization of in vitro stability testing of spinal implants. Eur Spine J 29:148–154. doi:10.1007/s005860050045 CrossRef Wilke HJ, Wenger K, Claes LE (1998) Testing criteria for spinal implants: recommendations for the standardization of in vitro stability testing of spinal implants. Eur Spine J 29:148–154. doi:10.​1007/​s005860050045 CrossRef
Metadata
Title
Biomechanical analysis of expansion screws and cortical screws used for ventral plate fixation on the cervical spine
Authors
Klaus Röhl
Bernhard Ullrich
Gerd Huber
Michael M. Morlock
Publication date
01-09-2009
Publisher
Springer-Verlag
Published in
European Spine Journal / Issue 9/2009
Print ISSN: 0940-6719
Electronic ISSN: 1432-0932
DOI
https://doi.org/10.1007/s00586-009-1087-5

Other articles of this Issue 9/2009

European Spine Journal 9/2009 Go to the issue