Abstract

Background and aims

A contaminated or infected surgical site is considered a contraindication for the use of the nonabsorbable alloplastic materials employed to repair abdominal wall defects. Therefore, the biocompatibility of new prosthetic materials was investigated.

Materials and methods

Meshes measuring 1.5×1.5 cm made of conventional and titanium-coated polypropylene, polyglycol, or porcine dermal collagen were implanted under the abdominal wall of 96 rats (eight groups of 12 animals each) employing the inlay technique. Implantation of all four materials was performed both under semisterile conditions and bacterial contamination of the mesh. The meshes were explanted after 28 days.

Results

All the materials implanted under semisterile conditions were incorporated into the abdominal wall with only few intraabdominal adhesions (mean adhesion scores: 1.0, 1.2, 1.0, 0.8 points, respectively, not significant). With the porcine dermal collagen, proliferation rate and the proportion of inflammatory cells were statistically lower (p<0.01). In the bacterial contamination group, all meshes were associated with a suppurating infection and strong adhesions between the bowel and mesh, which were most prominent in the case of dermal collagen (mean adhesion scores: 1.6, 1.7, 1.7, and 1.9 points, respectively, not significant). In this group, two animals died of peritonitis. In comparison with the other materials, the proliferation rate was significantly elevated (p=0.03). No significant differences were seen between the other materials employed.

Conclusion

Irrespective of the material employed, implantation of alloplastic meshes in an abdominal wall contaminated with bacteria, is associated with suppurating infections, in particular in the case of the membrane-like porcine dermal collagen. Nonabsorbable alloplastic meshes and dermal skin grafts should therefore not be used to repair infected abdominal wall defects.
Literature
1.
go back to reference Luijendijk RW, Hop WC, van den Tol MP, de Lange DC, Braaksma MM, IJzermans JN, Boelhouwer RU, de Vries BC, Salu MK, Wereldsma JC, Bruijninckx CM, Jeekel J (2000) A comparison of suture repair with mesh repair for incisional hernia. N Engl J Med 343(6):392–398PubMedCrossRef Luijendijk RW, Hop WC, van den Tol MP, de Lange DC, Braaksma MM, IJzermans JN, Boelhouwer RU, de Vries BC, Salu MK, Wereldsma JC, Bruijninckx CM, Jeekel J (2000) A comparison of suture repair with mesh repair for incisional hernia. N Engl J Med 343(6):392–398PubMedCrossRef
2.
go back to reference Korenkov M, Sauerland S, Arndt M, Bograd L, Neugebauer EA, Troidl H (2002) Randomized clinical trial of suture repair, polypropylene mesh or autodermal hernioplasty for incisional hernia. Br J Surg 89(1):50–56PubMedCrossRef Korenkov M, Sauerland S, Arndt M, Bograd L, Neugebauer EA, Troidl H (2002) Randomized clinical trial of suture repair, polypropylene mesh or autodermal hernioplasty for incisional hernia. Br J Surg 89(1):50–56PubMedCrossRef
3.
go back to reference Flum DR, Horvath K, Koepsell T (2003) Have outcomes of incisional hernia repair improved with time? A population-based analysis. Ann Surg 237(1):129–135PubMedCrossRef Flum DR, Horvath K, Koepsell T (2003) Have outcomes of incisional hernia repair improved with time? A population-based analysis. Ann Surg 237(1):129–135PubMedCrossRef
4.
go back to reference Law NW, Ellis H (1991) A comparison of polypropylene mesh and expanded polytetrafluoroethylene patch for the repair of contaminated abdominal wall defects—an experimental study. Surgery 109(5):652–655PubMed Law NW, Ellis H (1991) A comparison of polypropylene mesh and expanded polytetrafluoroethylene patch for the repair of contaminated abdominal wall defects—an experimental study. Surgery 109(5):652–655PubMed
5.
go back to reference Scheidbach H, Tannapfel A, Schmidt U, Lippert H, Köckerling F (2004) Influence of titanium coating on the biocompatibility of a heavyweight polypropylene mesh. An animal experimental model. Eur Surg Res 36(5):313–317PubMedCrossRef Scheidbach H, Tannapfel A, Schmidt U, Lippert H, Köckerling F (2004) Influence of titanium coating on the biocompatibility of a heavyweight polypropylene mesh. An animal experimental model. Eur Surg Res 36(5):313–317PubMedCrossRef
6.
go back to reference Chaplin JM, Costantino PD, Wolpoe ME, Bederson JB, Griffey ES, Zhang WX (1999) Use of an acellular dermal allograft for dural replacement: an experimental study. Neurosurgery 45:320–327PubMedCrossRef Chaplin JM, Costantino PD, Wolpoe ME, Bederson JB, Griffey ES, Zhang WX (1999) Use of an acellular dermal allograft for dural replacement: an experimental study. Neurosurgery 45:320–327PubMedCrossRef
7.
go back to reference Klinge U, Junge K, Spellerberg B, Piroth C, Klosterhalfen B, Schumpelick V (2002) Do multifilament alloplastic meshes increase the infection rate? Analysis of the polymeric surface, the bacteria adherence, and the in vivo consequences in a rat model. J Biomed Mater Res 63:765–771PubMedCrossRef Klinge U, Junge K, Spellerberg B, Piroth C, Klosterhalfen B, Schumpelick V (2002) Do multifilament alloplastic meshes increase the infection rate? Analysis of the polymeric surface, the bacteria adherence, and the in vivo consequences in a rat model. J Biomed Mater Res 63:765–771PubMedCrossRef
8.
go back to reference van ‘t Riet M, de Vos van Steenwijk PJ, Bonthuis F, Marquet RL, Steyerberg EW, Jeekel J, Bonjer HJ (2003) Prevention of adhesion to prosthetic mesh: comparison of different barriers using an incisional hernia model. Ann Surg 237(1):123–128CrossRef van ‘t Riet M, de Vos van Steenwijk PJ, Bonthuis F, Marquet RL, Steyerberg EW, Jeekel J, Bonjer HJ (2003) Prevention of adhesion to prosthetic mesh: comparison of different barriers using an incisional hernia model. Ann Surg 237(1):123–128CrossRef
9.
go back to reference Lopez Villalta GC, Furio-Bacete V, Ortiz Oshiro E, Lopez DO, Vaca Vaticon D, Fdez-Represa JA (1995) Experimentally contaminated reabsorbable meshes: their evolution in abdominal wall defects. Int Surg 80(3):223–226PubMed Lopez Villalta GC, Furio-Bacete V, Ortiz Oshiro E, Lopez DO, Vaca Vaticon D, Fdez-Represa JA (1995) Experimentally contaminated reabsorbable meshes: their evolution in abdominal wall defects. Int Surg 80(3):223–226PubMed
10.
go back to reference Junge K, Rosch R, Klinge U, Saklak M, Klosterhalfen B, Peiper C, Schumpelick V (2005) Titanium coating of a polypropylene mesh for hernia repair: effect on biocompatibility. Hernia 9(2):115–119PubMedCrossRef Junge K, Rosch R, Klinge U, Saklak M, Klosterhalfen B, Peiper C, Schumpelick V (2005) Titanium coating of a polypropylene mesh for hernia repair: effect on biocompatibility. Hernia 9(2):115–119PubMedCrossRef
11.
go back to reference Birolini C, Utiyama EM, Rodrigues AJ Jr, Birolini D (2000) Elective colonic operation and prosthetic repair of incisional hernia: does contamination contraindicate abdominal wall prosthesis use? J Am Coll Surg 191(4):366–372PubMedCrossRef Birolini C, Utiyama EM, Rodrigues AJ Jr, Birolini D (2000) Elective colonic operation and prosthetic repair of incisional hernia: does contamination contraindicate abdominal wall prosthesis use? J Am Coll Surg 191(4):366–372PubMedCrossRef
12.
go back to reference Leber GE, Garb JL, Alexander AI, Reed WP (1998) Long-term complications associated with prosthetic repair of incisional hernias. Arch Surg 133(4):378–382PubMedCrossRef Leber GE, Garb JL, Alexander AI, Reed WP (1998) Long-term complications associated with prosthetic repair of incisional hernias. Arch Surg 133(4):378–382PubMedCrossRef
13.
go back to reference Vrijland WW, Jeekel J, Steyerberg EW, Den Hoed PT, Bonjer HJ (2000) Intraperitoneal polypropylene mesh repair of incisional hernia is not associated with enterocutaneous fistula. Br J Surg 87(3):348–352PubMedCrossRef Vrijland WW, Jeekel J, Steyerberg EW, Den Hoed PT, Bonjer HJ (2000) Intraperitoneal polypropylene mesh repair of incisional hernia is not associated with enterocutaneous fistula. Br J Surg 87(3):348–352PubMedCrossRef
14.
go back to reference Costerton JW, Stewart PS, Greenberg EP (1999) Bacterial biofilms: a common cause of persistent infections. Science 284:1318–1321PubMedCrossRef Costerton JW, Stewart PS, Greenberg EP (1999) Bacterial biofilms: a common cause of persistent infections. Science 284:1318–1321PubMedCrossRef
15.
go back to reference An YH, Friedman RJ (1998) Concise review of bacterial adhesion to biomaterial surfaces. J Biomed Mater Res 43:338–348PubMedCrossRef An YH, Friedman RJ (1998) Concise review of bacterial adhesion to biomaterial surfaces. J Biomed Mater Res 43:338–348PubMedCrossRef
16.
go back to reference Bellon JM, Garcia-Carranza A, Garcia-Honduvilla N, Carrera-San Martin A, Bujan J (2004) Tissue integration and biochemical behaviour of contaminated experimental polypropylene and expanded polytetrafluoroethylene implants. Br J Surg 91:489–494PubMedCrossRef Bellon JM, Garcia-Carranza A, Garcia-Honduvilla N, Carrera-San Martin A, Bujan J (2004) Tissue integration and biochemical behaviour of contaminated experimental polypropylene and expanded polytetrafluoroethylene implants. Br J Surg 91:489–494PubMedCrossRef
17.
go back to reference Bellon JM, Contreras LA, Bujan J (2000) Ultrastructural alterations of polytetrafluoroethylene prostheses implanted in abdominal wall provoked by infection: clinical and experimental study. World J Surg 24:528–532PubMedCrossRef Bellon JM, Contreras LA, Bujan J (2000) Ultrastructural alterations of polytetrafluoroethylene prostheses implanted in abdominal wall provoked by infection: clinical and experimental study. World J Surg 24:528–532PubMedCrossRef
18.
go back to reference Bleichrodt RP, Simmermacher RK, van der Lei B, Schakenraad JM (1993) Expanded polytetrafluoroethylene patch versus polypropylene mesh for the repair of contaminated defects of the abdominal wall. Surg Gynecol Obstet 176(1):18–24PubMed Bleichrodt RP, Simmermacher RK, van der Lei B, Schakenraad JM (1993) Expanded polytetrafluoroethylene patch versus polypropylene mesh for the repair of contaminated defects of the abdominal wall. Surg Gynecol Obstet 176(1):18–24PubMed
19.
go back to reference Junge K, Rosch R, Klinge U, Krones C, Klosterhalfen B, Mertens PR, Lynen P, Kunz D, Preiss A, Peltroche-Llacsahuanga H, Schumpelick V (2005) Gentamicin supplementation of polyvinylidenfluoride mesh materials for infection prophylaxis. Biomaterials 26(7):787–793PubMedCrossRef Junge K, Rosch R, Klinge U, Krones C, Klosterhalfen B, Mertens PR, Lynen P, Kunz D, Preiss A, Peltroche-Llacsahuanga H, Schumpelick V (2005) Gentamicin supplementation of polyvinylidenfluoride mesh materials for infection prophylaxis. Biomaterials 26(7):787–793PubMedCrossRef
Metadata
Title
Biocompatibility of bacterial contaminated prosthetic meshes and porcine dermal collagen used to repair abdominal wall defects
Authors
R. Ott
T. Hartwig
A. Tannapfel
R. Blatz
A. C. Rodloff
P. Madaj-Sterba
Ch. Möbius
F. Köckerling
Publication date
01-07-2007
Publisher
Springer-Verlag
Published in
Langenbeck's Archives of Surgery / Issue 4/2007
Print ISSN: 1435-2443
Electronic ISSN: 1435-2451
DOI
https://doi.org/10.1007/s00423-006-0080-2

Other articles of this Issue 4/2007

Langenbeck's Archives of Surgery 4/2007 Go to the issue