Published in: Pediatric Surgery International 7/2005

01-07-2005 | Original Article

Bacterial contamination of central venous catheters during insertion: a double blind randomised controlled trial

Authors: N. J. Hall, J. Hartley, N. Ade-Ajayi, K. Laughlan, D. Roebuck, T. Kleidon, D. Powis, A. Pierro

Published in: Pediatric Surgery International | Issue 7/2005

Login to get access

Abstract

Static electricity within sterile packaging may result in bacterial contamination of central venous catheters (CVCs) prior to insertion. To prevent this, some surgeons inject saline into the pack before opening it. This trial was designed to determine the effect of this procedure. A double blind randomised controlled trial of 47 CVCs comparing injection of 2 ml of sterile saline into the pack prior to opening with no injection was performed. Five centimetre lengths cut from the tip of the catheter before and after subcutaneous tunnelling were sent for microbiological culture. Eight catheters (17%) showed evidence of bacterial contamination prior to insertion into the vein. Two (4.2%) were contaminated prior to tunnelling and seven (14.9%) afterwards. One catheter was contaminated before and after tunnelling. All but one of the contaminating bacteria were coagulase negative staphylococci. There was no significant difference in the contamination rate between catheters from packs that had been injected (5/25) and those that had not (3/22), P=0.56. Just under one-fifth of the catheters were contaminated with bacteria prior to insertion into the vein but this was not influenced by prior injection of saline into the pack. We conclude that there is no evidence to support the practice of injecting the catheter pack prior to opening.
Literature
1.
go back to reference O’grady NP, Alexander M, Dellinger EP et al (2002) Guidelines for the prevention of intravascular catheter-related infections. Am J Infect Control 30:476–489PubMedCrossRef O’grady NP, Alexander M, Dellinger EP et al (2002) Guidelines for the prevention of intravascular catheter-related infections. Am J Infect Control 30:476–489PubMedCrossRef
2.
go back to reference Allen JE, Henshaw DL, Wynne H, Ross F, Oakhill A (2003) Static electric charge may contribute to infections in bone marrow transplant wards. J Hosp Infect 54:80–81CrossRefPubMed Allen JE, Henshaw DL, Wynne H, Ross F, Oakhill A (2003) Static electric charge may contribute to infections in bone marrow transplant wards. J Hosp Infect 54:80–81CrossRefPubMed
3.
go back to reference Cozanitis DA, Ojajarvi J, Makela P (1988) Antistatic treatment for reducing airborne contamination of insulating materials in intensive care. Acta Anaesthesiol Scand 32:343–346PubMedCrossRef Cozanitis DA, Ojajarvi J, Makela P (1988) Antistatic treatment for reducing airborne contamination of insulating materials in intensive care. Acta Anaesthesiol Scand 32:343–346PubMedCrossRef
4.
go back to reference Colomb V, Fabeiro M, Dabbas M, Goulet O, Merckx J, Ricour C (2000) Central venous catheter-related infections in children on long-term home parenteral nutrition: incidence and risk factors. Clin Nutr 19:355–359PubMedCrossRef Colomb V, Fabeiro M, Dabbas M, Goulet O, Merckx J, Ricour C (2000) Central venous catheter-related infections in children on long-term home parenteral nutrition: incidence and risk factors. Clin Nutr 19:355–359PubMedCrossRef
5.
go back to reference Das I, Philpott C, George RH (1997) Central venous catheter-related septicaemia in paediatric cancer patients. J Hosp Infect 36:67–76CrossRefPubMed Das I, Philpott C, George RH (1997) Central venous catheter-related septicaemia in paediatric cancer patients. J Hosp Infect 36:67–76CrossRefPubMed
6.
go back to reference Domm JA, Hudson MG, Janco RL (2003) Complications of central venous access devices in paediatric haemophilia patients. Haemophilia 9:50–56CrossRefPubMed Domm JA, Hudson MG, Janco RL (2003) Complications of central venous access devices in paediatric haemophilia patients. Haemophilia 9:50–56CrossRefPubMed
7.
go back to reference Tarantino MD, Lail A, Donfield SM et al (2003) Surveillance of infectious complications associated with central venous access devices in children with haemophilia. Haemophilia 9:588–592CrossRefPubMed Tarantino MD, Lail A, Donfield SM et al (2003) Surveillance of infectious complications associated with central venous access devices in children with haemophilia. Haemophilia 9:588–592CrossRefPubMed
8.
go back to reference Shaul DB, Scheer B, Rokhsar S et al (1998) Risk factors for early infection of central venous catheters in pediatric patients. J Am Coll Surg 186:654–658CrossRefPubMed Shaul DB, Scheer B, Rokhsar S et al (1998) Risk factors for early infection of central venous catheters in pediatric patients. J Am Coll Surg 186:654–658CrossRefPubMed
Metadata
Title
Bacterial contamination of central venous catheters during insertion: a double blind randomised controlled trial
Authors
N. J. Hall
J. Hartley
N. Ade-Ajayi
K. Laughlan
D. Roebuck
T. Kleidon
D. Powis
A. Pierro
Publication date
01-07-2005
Publisher
Springer-Verlag
Published in
Pediatric Surgery International / Issue 7/2005
Print ISSN: 0179-0358
Electronic ISSN: 1437-9813
DOI
https://doi.org/10.1007/s00383-005-1478-6

Other articles of this Issue 7/2005

Pediatric Surgery International 7/2005 Go to the issue