Skip to main content
Top
Published in: BMC Proceedings 3/2015

Open Access 01-12-2015 | Meeting abstract

Avoiding complication of volar locked plates

Author: Marcos Sanmartin Fernandez

Published in: BMC Proceedings | Special Issue 3/2015

Login to get access

Excerpt

Volar locking plates are designed to improve and maintain anatomic alignment, even in patients with dorsal comminution and poor metaphyseal bone quality. Its widespread use led to specific complications. Most part is related to tendon, nerve and complex regional pain syndrome [1] and could be avoided by meticulous attention to detail and surgical experience [2]. …
Literature
1.
go back to reference Bentohami K, de Burlet K, de Korte N, van den Bekerom MPJ, Goslings JC, Schep NWL: Complications following volar locking plate fixation for distal radial fractures: a systematic review. J Hand Surg Eur. 2014, 39 (7): 745-754. 10.1177/1753193413511936.CrossRef Bentohami K, de Burlet K, de Korte N, van den Bekerom MPJ, Goslings JC, Schep NWL: Complications following volar locking plate fixation for distal radial fractures: a systematic review. J Hand Surg Eur. 2014, 39 (7): 745-754. 10.1177/1753193413511936.CrossRef
2.
go back to reference Ward CM, Kuhl TL, Adams BD: Early complications of volar plating after distal radius fractures and their relationship to surgeon experience. Hand. 2011, 6 (2): 185-189. 10.1007/s11552-010-9313-5.PubMedPubMedCentralCrossRef Ward CM, Kuhl TL, Adams BD: Early complications of volar plating after distal radius fractures and their relationship to surgeon experience. Hand. 2011, 6 (2): 185-189. 10.1007/s11552-010-9313-5.PubMedPubMedCentralCrossRef
3.
go back to reference Bonatz E, Kramer TD, Masear VR: Rupture of the extensor pollicis longus tendon. Am J Orthop (Belle Mead NJ). 1996, 25 (2): 118-122. Bonatz E, Kramer TD, Masear VR: Rupture of the extensor pollicis longus tendon. Am J Orthop (Belle Mead NJ). 1996, 25 (2): 118-122.
4.
go back to reference Thomas A, Greenberg J: Use of Fluoroscopy in Determining Screw Overshoot in the Dorsal Distal Radius: A Cadaveric Study. J Hand Surg. 2009, 34A (2): 258-261.CrossRef Thomas A, Greenberg J: Use of Fluoroscopy in Determining Screw Overshoot in the Dorsal Distal Radius: A Cadaveric Study. J Hand Surg. 2009, 34A (2): 258-261.CrossRef
5.
go back to reference Kitay A, Swanstrom M, Schreiber JJ, Carlson MG, Nguyen JT, Weiland AJ, Daluiski A: Volar Plate Position and Flexor Tendon Rupture Following Distal Radius Fracture Fixation. J Hand Surg. 2013, 38 (6): 1091-1096. 10.1016/j.jhsa.2013.03.011.CrossRef Kitay A, Swanstrom M, Schreiber JJ, Carlson MG, Nguyen JT, Weiland AJ, Daluiski A: Volar Plate Position and Flexor Tendon Rupture Following Distal Radius Fracture Fixation. J Hand Surg. 2013, 38 (6): 1091-1096. 10.1016/j.jhsa.2013.03.011.CrossRef
6.
go back to reference Pace A, Cresswell T: Use of Articular Wrist Views to Assess Intra-Articular Screw Penetration in Surgical Fixation of Distal Radius Fractures. J Hand Surg. 2010, 35 (6): 1015-1018. 10.1016/j.jhsa.2010.03.041.CrossRef Pace A, Cresswell T: Use of Articular Wrist Views to Assess Intra-Articular Screw Penetration in Surgical Fixation of Distal Radius Fractures. J Hand Surg. 2010, 35 (6): 1015-1018. 10.1016/j.jhsa.2010.03.041.CrossRef
7.
go back to reference Smith DW, Henry MH: The 45-degree pronated oblique view for volar fixed angle plating of distal radius fractures. J Hand Surg. 2004, 29 (4): 703-706. 10.1016/j.jhsa.2004.04.006.CrossRef Smith DW, Henry MH: The 45-degree pronated oblique view for volar fixed angle plating of distal radius fractures. J Hand Surg. 2004, 29 (4): 703-706. 10.1016/j.jhsa.2004.04.006.CrossRef
8.
go back to reference Mehling M, Müller LP, Delinsky K, Mehler D, Burkhart KJ, Rommens PM: Number and Locations of Screw Fixation for Volar Fixed-Angle Plating of Distal Radius Fractures: Biomechanical Study. J Hand Surg. 2010, 35 (6): 885-891. 10.1016/j.jhsa.2010.03.027.CrossRef Mehling M, Müller LP, Delinsky K, Mehler D, Burkhart KJ, Rommens PM: Number and Locations of Screw Fixation for Volar Fixed-Angle Plating of Distal Radius Fractures: Biomechanical Study. J Hand Surg. 2010, 35 (6): 885-891. 10.1016/j.jhsa.2010.03.027.CrossRef
9.
go back to reference Wall LB, Brodt MD, Silva MJ, Boyer MI, Calfee RP: The Effects of Screw Length on Stability of Simulated Osteoporotic Distal Radius Fractures Fixed With Volar Locking Plates. J Hand Surg. 2012, 37 (3): 446-453. 10.1016/j.jhsa.2011.12.013.CrossRef Wall LB, Brodt MD, Silva MJ, Boyer MI, Calfee RP: The Effects of Screw Length on Stability of Simulated Osteoporotic Distal Radius Fractures Fixed With Volar Locking Plates. J Hand Surg. 2012, 37 (3): 446-453. 10.1016/j.jhsa.2011.12.013.CrossRef
10.
go back to reference Gyuricza C, Carlson MG, Weiland AJ, Wolfe SW, Hotchkiss RN, Daluiski A: Removal of Locked Volar Plates After Distal Radius Fractures. J Hand Surg. 2011, 36 (6): 982-985. 10.1016/j.jhsa.2011.03.032.CrossRef Gyuricza C, Carlson MG, Weiland AJ, Wolfe SW, Hotchkiss RN, Daluiski A: Removal of Locked Volar Plates After Distal Radius Fractures. J Hand Surg. 2011, 36 (6): 982-985. 10.1016/j.jhsa.2011.03.032.CrossRef
Metadata
Title
Avoiding complication of volar locked plates
Author
Marcos Sanmartin Fernandez
Publication date
01-12-2015
Publisher
BioMed Central
Published in
BMC Proceedings / Issue Special Issue 3/2015
Electronic ISSN: 1753-6561
DOI
https://doi.org/10.1186/1753-6561-9-S3-A42

Other articles of this Special Issue 3/2015

BMC Proceedings 3/2015 Go to the issue