Skip to main content
Top
Published in: Journal of Orthopaedic Surgery and Research 1/2014

Open Access 01-12-2014 | Research article

Assessment of retention force and bone apposition in two differently coated femoral stems after 6 months of loading in a goat model

Authors: Knut Harboe, Nils R Gjerdet, Einar Sudmann, Kari Indrekvam, Kjetil Søreide

Published in: Journal of Orthopaedic Surgery and Research | Issue 1/2014

Login to get access

Abstract

Background

Since the introduction of uncemented hip implants, there has been a search for the best surface coating to enhance bone apposition in order to improve retention. The surface coating of the different stems varies between products. The aim was to assess the retention force and bone adaption in two differently coated stems in a weight-bearing goat model.

Materials and methods

Hydroxyapatite (HA) and electrochemically deposited calcium phosphate (CP; Bonit®) on geometrically comparable titanium-based femoral stems were implanted into 12 (CP group) and 35 (HA group) goats. The animal model included physiological loading of the implants for 6 months. The pull-out force of the stems was measured, and bone apposition was microscopically evaluated.

Results

After exclusion criteria were applied, the number of available goats was 4 in the CP group and 11 in the HA group. The CP-coated stems had significantly lower retention forces compared with the HA-coated ones after 6 months (CP median 47 N, HA median 1,696 N, p = 0.003). Bone sections revealed a lower degree of bone apposition in the CP-coated stems, with more connective tissue in the bone/implant interface compared with the HA group.

Conclusion

In this study, HA had better bone apposition and needed greater pull-out force in loaded implants. The application of CP on the loaded titanium surface to enhance the apposition of bone is questioned.
Appendix
Available only for authorised users
Literature
1.
go back to reference Furnes O, Havelin L, Espehaug B, Steindal K, Sørås T: The Norwegian Arthroplasty Register - Annual Report. 2012, Norway, Bergen Furnes O, Havelin L, Espehaug B, Steindal K, Sørås T: The Norwegian Arthroplasty Register - Annual Report. 2012, Norway, Bergen
2.
go back to reference Azegami S, Gurusamy KS, Parker MJ: Cemented versus uncemented hemiarthroplasty for hip fractures: a systematic review of randomised controlled trials. Hip Int. 2011, 21: 509-517. 10.5301/HIP.2011.8640.CrossRefPubMed Azegami S, Gurusamy KS, Parker MJ: Cemented versus uncemented hemiarthroplasty for hip fractures: a systematic review of randomised controlled trials. Hip Int. 2011, 21: 509-517. 10.5301/HIP.2011.8640.CrossRefPubMed
3.
go back to reference Gjertsen JE, Lie SA, Vinje T, Engesaeter LB, Hallan G, Matre K, Furnes O: More re-operations after uncemented than cemented hemiarthroplasty used in the treatment of displaced fractures of the femoral neck: an observational study of 11,116 hemiarthroplasties from a national register. J Bone Joint Surg Br. 2012, 94: 1113-1119. 10.1302/0301-620X.94B8.29155.CrossRefPubMed Gjertsen JE, Lie SA, Vinje T, Engesaeter LB, Hallan G, Matre K, Furnes O: More re-operations after uncemented than cemented hemiarthroplasty used in the treatment of displaced fractures of the femoral neck: an observational study of 11,116 hemiarthroplasties from a national register. J Bone Joint Surg Br. 2012, 94: 1113-1119. 10.1302/0301-620X.94B8.29155.CrossRefPubMed
4.
go back to reference McMinn DJ, Snell KI, Daniel J, Treacy RB, Pynsent PB, Riley RD: Mortality and implant revision rates of hip arthroplasty in patients with osteoarthritis: registry based cohort study. BMJ. 2012, 344: e3319-10.1136/bmj.e3319.PubMedCentralCrossRefPubMed McMinn DJ, Snell KI, Daniel J, Treacy RB, Pynsent PB, Riley RD: Mortality and implant revision rates of hip arthroplasty in patients with osteoarthritis: registry based cohort study. BMJ. 2012, 344: e3319-10.1136/bmj.e3319.PubMedCentralCrossRefPubMed
5.
go back to reference Dale H, Fenstad AM, Hallan G, Havelin LI, Furnes O, Overgaard S, Pedersen AB, Karrholm J, Garellick G, Pulkkinen P, Eskelinen A, Makela K, Engesaeter LB: Increasing risk of prosthetic joint infection after total hip arthroplasty. Acta Orthop. 2012, 83: 449-458. 10.3109/17453674.2012.733918.PubMedCentralCrossRefPubMed Dale H, Fenstad AM, Hallan G, Havelin LI, Furnes O, Overgaard S, Pedersen AB, Karrholm J, Garellick G, Pulkkinen P, Eskelinen A, Makela K, Engesaeter LB: Increasing risk of prosthetic joint infection after total hip arthroplasty. Acta Orthop. 2012, 83: 449-458. 10.3109/17453674.2012.733918.PubMedCentralCrossRefPubMed
6.
go back to reference Brennan SA, Khan F, Kiernan C, Queally JM, McQuillan J, Gormley IC, O'Byrne JM: Dislocation of primary total hip arthroplasty and the risk of redislocation. Hip Int. 2012, 22: 500-504. 10.5301/HIP.2012.9747.CrossRefPubMed Brennan SA, Khan F, Kiernan C, Queally JM, McQuillan J, Gormley IC, O'Byrne JM: Dislocation of primary total hip arthroplasty and the risk of redislocation. Hip Int. 2012, 22: 500-504. 10.5301/HIP.2012.9747.CrossRefPubMed
7.
go back to reference Schmalzried TP: The painful hip: diagnosis and deliverance. J Bone Joint Surg Br. 2012, 94-B: 55-57. 10.1302/0301-620X.94B11.30825.CrossRef Schmalzried TP: The painful hip: diagnosis and deliverance. J Bone Joint Surg Br. 2012, 94-B: 55-57. 10.1302/0301-620X.94B11.30825.CrossRef
8.
go back to reference Reimeringer M, Nuno N, Desmarais-Trepanier C, Lavigne M, Vendittoli PA: The influence of uncemented femoral stem length and design on its primary stability: a finite element analysis. Comput Methods Biomech Biomed Engin. 2013, 16: 1221-1231. 10.1080/10255842.2012.662677.CrossRefPubMed Reimeringer M, Nuno N, Desmarais-Trepanier C, Lavigne M, Vendittoli PA: The influence of uncemented femoral stem length and design on its primary stability: a finite element analysis. Comput Methods Biomech Biomed Engin. 2013, 16: 1221-1231. 10.1080/10255842.2012.662677.CrossRefPubMed
9.
go back to reference Capello WN, D'Antonio JA, Feinberg JR, Manley MT: Ten-year results with hydroxyapatite-coated total hip femoral components in patients less than fifty years old. A concise follow-up of a previous report. J Bone Joint Surg Am. 2003, 85-A: 885-889.PubMed Capello WN, D'Antonio JA, Feinberg JR, Manley MT: Ten-year results with hydroxyapatite-coated total hip femoral components in patients less than fifty years old. A concise follow-up of a previous report. J Bone Joint Surg Am. 2003, 85-A: 885-889.PubMed
10.
go back to reference Hennessy DW, Callaghan JJ, Liu SS: Second-generation extensively porous-coated THA stems at minimum 10-year followup. Clin Orthop Relat Res. 2009, 467: 2290-2296. 10.1007/s11999-009-0831-9.PubMedCentralCrossRefPubMed Hennessy DW, Callaghan JJ, Liu SS: Second-generation extensively porous-coated THA stems at minimum 10-year followup. Clin Orthop Relat Res. 2009, 467: 2290-2296. 10.1007/s11999-009-0831-9.PubMedCentralCrossRefPubMed
11.
go back to reference Boe BG, Rohrl SM, Heier T, Snorrason F, Nordsletten L: A prospective randomized study comparing electrochemically deposited hydroxyapatite and plasma-sprayed hydroxyapatite on titanium stems. Acta Orthop. 2011, 82: 13-19. 10.3109/17453674.2010.548027.PubMedCentralCrossRefPubMed Boe BG, Rohrl SM, Heier T, Snorrason F, Nordsletten L: A prospective randomized study comparing electrochemically deposited hydroxyapatite and plasma-sprayed hydroxyapatite on titanium stems. Acta Orthop. 2011, 82: 13-19. 10.3109/17453674.2010.548027.PubMedCentralCrossRefPubMed
12.
go back to reference Harboe K, Enoksen CH, Gjerdet NR, Sudmann E: Development of a femoral stem providing strong anchorage and facilitated removal. An experimental study in goats. Vet Comp Orthop Traumatol. 2012, 25: 95-101. 10.3415/VCOT-11-02-0032.CrossRefPubMed Harboe K, Enoksen CH, Gjerdet NR, Sudmann E: Development of a femoral stem providing strong anchorage and facilitated removal. An experimental study in goats. Vet Comp Orthop Traumatol. 2012, 25: 95-101. 10.3415/VCOT-11-02-0032.CrossRefPubMed
13.
go back to reference Peters A: Postoperatieve fixatiewagen voor grote dieren. Biotechniek. 1990, 1990: 79-80. Peters A: Postoperatieve fixatiewagen voor grote dieren. Biotechniek. 1990, 1990: 79-80.
14.
go back to reference An YH, Draughn RA: Mechanical Testing of Bone and the Bone-Implant Interface. 2000, CRC, South Carolina An YH, Draughn RA: Mechanical Testing of Bone and the Bone-Implant Interface. 2000, CRC, South Carolina
15.
go back to reference Geesink RG, De Groot K, Klein CP: Chemical implant fixation using hydroxyl-apatite coatings. The development of a human total hip prosthesis for chemical fixation to bone using hydroxyl-apatite coatings on titanium substrates. Clin Orthop Relat Res. 1987, 225: 147-170.PubMed Geesink RG, De Groot K, Klein CP: Chemical implant fixation using hydroxyl-apatite coatings. The development of a human total hip prosthesis for chemical fixation to bone using hydroxyl-apatite coatings on titanium substrates. Clin Orthop Relat Res. 1987, 225: 147-170.PubMed
16.
go back to reference Reigstad O, Franke-Stenport V, Johansson CB, Wennerberg A, Rokkum M, Reigstad A: Improved bone ingrowth and fixation with a thin calcium phosphate coating intended for complete resorption. J Biomed Mater Res B Appl Biomater. 2007, 83: 9-15. 10.1002/jbm.b.30762.CrossRefPubMed Reigstad O, Franke-Stenport V, Johansson CB, Wennerberg A, Rokkum M, Reigstad A: Improved bone ingrowth and fixation with a thin calcium phosphate coating intended for complete resorption. J Biomed Mater Res B Appl Biomater. 2007, 83: 9-15. 10.1002/jbm.b.30762.CrossRefPubMed
17.
go back to reference Røkkum M, Reigstad A, Johansson CB: HA particles can be released from well-fixed HA-coated stems: histopathology of biopsies from 20 hips 2–8 years after implantation. Acta Orthop Scand. 2002, 73: 298-306. 10.1080/000164702320155293.CrossRefPubMed Røkkum M, Reigstad A, Johansson CB: HA particles can be released from well-fixed HA-coated stems: histopathology of biopsies from 20 hips 2–8 years after implantation. Acta Orthop Scand. 2002, 73: 298-306. 10.1080/000164702320155293.CrossRefPubMed
18.
go back to reference Bastian L, Hufner T, Mossinger E, Geerling J, Goesling T, Busche M, Kendoff D, Bading S, Rosenthal H, Krettek C: Integration of modern technologies in therapy of sarcomas of the pelvis. Computer-assisted hemipelvectomy and implantation of a “custom-made” Bonit gentamycin coated partial pelvic prosthesis. Unfallchirurg. 2003, 106: 956-962.PubMed Bastian L, Hufner T, Mossinger E, Geerling J, Goesling T, Busche M, Kendoff D, Bading S, Rosenthal H, Krettek C: Integration of modern technologies in therapy of sarcomas of the pelvis. Computer-assisted hemipelvectomy and implantation of a “custom-made” Bonit gentamycin coated partial pelvic prosthesis. Unfallchirurg. 2003, 106: 956-962.PubMed
20.
go back to reference Reigstad O, Johansson C, Stenport V, Wennerberg A, Reigstad A, Rokkum M: Different patterns of bone fixation with hydroxyapatite and resorbable CaP coatings in the rabbit tibia at 6, 12, and 52 weeks. J Biomed Mater Res B Appl Biomater. 2011, 99: 14-20. 10.1002/jbm.b.31866.CrossRefPubMed Reigstad O, Johansson C, Stenport V, Wennerberg A, Reigstad A, Rokkum M: Different patterns of bone fixation with hydroxyapatite and resorbable CaP coatings in the rabbit tibia at 6, 12, and 52 weeks. J Biomed Mater Res B Appl Biomater. 2011, 99: 14-20. 10.1002/jbm.b.31866.CrossRefPubMed
21.
go back to reference Becker P, Neumann HG, Nebe B, Luthen F, Rychly J: Cellular investigations on electrochemically deposited calcium phosphate composites. J Mater Sci Mater Med. 2004, 15: 437-440. 10.1023/B:JMSM.0000021116.13016.61.CrossRefPubMed Becker P, Neumann HG, Nebe B, Luthen F, Rychly J: Cellular investigations on electrochemically deposited calcium phosphate composites. J Mater Sci Mater Med. 2004, 15: 437-440. 10.1023/B:JMSM.0000021116.13016.61.CrossRefPubMed
22.
go back to reference Buratti CA, D'Arrigo C, Guido G, Lenzi F, Logroscino GD, Magliocchetti G, Mannocci C, Patella S, Patella V, Salvi V, Speranza A, Speciale D, Spinarelli A, Topa D: Assessment of the initial stability of the Symax femoral stem with EBRA-FCA: a multicentric study of 85 cases. Hip Int. 2009, 19: 24-29.PubMed Buratti CA, D'Arrigo C, Guido G, Lenzi F, Logroscino GD, Magliocchetti G, Mannocci C, Patella S, Patella V, Salvi V, Speranza A, Speciale D, Spinarelli A, Topa D: Assessment of the initial stability of the Symax femoral stem with EBRA-FCA: a multicentric study of 85 cases. Hip Int. 2009, 19: 24-29.PubMed
23.
go back to reference ten Broeke RH, Alves A, Baumann A, Arts JJ, Geesink RG: Bone reaction to a biomimetic third-generation hydroxyapatite coating and new surface treatment for the Symax hip stem. J Bone Joint Surg Br. 2011, 93: 760-768. 10.1302/0301-620X.93B6.24986.CrossRefPubMed ten Broeke RH, Alves A, Baumann A, Arts JJ, Geesink RG: Bone reaction to a biomimetic third-generation hydroxyapatite coating and new surface treatment for the Symax hip stem. J Bone Joint Surg Br. 2011, 93: 760-768. 10.1302/0301-620X.93B6.24986.CrossRefPubMed
24.
go back to reference ten Broeke RH, Hendrickx RP, Leffers P, Jutten LM, Geesink RG: Randomised trial comparing bone remodelling around two uncemented stems using modified Gruen zones. Hip Int. 2012, 22: 41-49. 10.5301/HIP.2012.9103.CrossRefPubMed ten Broeke RH, Hendrickx RP, Leffers P, Jutten LM, Geesink RG: Randomised trial comparing bone remodelling around two uncemented stems using modified Gruen zones. Hip Int. 2012, 22: 41-49. 10.5301/HIP.2012.9103.CrossRefPubMed
25.
go back to reference Morscher EW, Hefti A, Aebi U: Severe osteolysis after third-body wear due to hydroxyapatite particles from acetabular cup coating. J Bone Joint Surg Br. 1998, 80: 267-272. 10.1302/0301-620X.80B2.8316.CrossRefPubMed Morscher EW, Hefti A, Aebi U: Severe osteolysis after third-body wear due to hydroxyapatite particles from acetabular cup coating. J Bone Joint Surg Br. 1998, 80: 267-272. 10.1302/0301-620X.80B2.8316.CrossRefPubMed
26.
go back to reference Wang J, Sun C, Wang Y: Early bone apposition and 1-year performance of the electrodeposited calcium phosphate coatings: an experimental study in rabbit femora. Clin Oral Implants Res. 2010, 21: 951-960.PubMed Wang J, Sun C, Wang Y: Early bone apposition and 1-year performance of the electrodeposited calcium phosphate coatings: an experimental study in rabbit femora. Clin Oral Implants Res. 2010, 21: 951-960.PubMed
27.
go back to reference Soballe K, Hansen ES, B-Rasmussen H, Jorgensen PH, Bunger C: Tissue ingrowth into titanium and hydroxyapatite-coated implants during stable and unstable mechanical conditions. J Orthop Res. 1992, 10: 285-299. 10.1002/jor.1100100216.CrossRefPubMed Soballe K, Hansen ES, B-Rasmussen H, Jorgensen PH, Bunger C: Tissue ingrowth into titanium and hydroxyapatite-coated implants during stable and unstable mechanical conditions. J Orthop Res. 1992, 10: 285-299. 10.1002/jor.1100100216.CrossRefPubMed
28.
go back to reference Stephenson PK, Freeman MA, Revell PA, Germain J, Tuke M, Pirie CJ: The effect of hydroxyapatite coating on ingrowth of bone into cavities in an implant. J Arthroplasty. 1991, 6: 51-58. 10.1016/S0883-5403(06)80157-9.CrossRefPubMed Stephenson PK, Freeman MA, Revell PA, Germain J, Tuke M, Pirie CJ: The effect of hydroxyapatite coating on ingrowth of bone into cavities in an implant. J Arthroplasty. 1991, 6: 51-58. 10.1016/S0883-5403(06)80157-9.CrossRefPubMed
29.
go back to reference Klenke FM, Liu Y, Yuan H, Hunziker EB, Siebenrock KA, Hofstetter W: Impact of pore size on the vascularization and osseointegration of ceramic bone substitutes in vivo. J Biomed Mater Res A. 2008, 85: 777-786. 10.1002/jbm.a.31559.CrossRefPubMed Klenke FM, Liu Y, Yuan H, Hunziker EB, Siebenrock KA, Hofstetter W: Impact of pore size on the vascularization and osseointegration of ceramic bone substitutes in vivo. J Biomed Mater Res A. 2008, 85: 777-786. 10.1002/jbm.a.31559.CrossRefPubMed
30.
go back to reference Yamamoto M, Tabata Y, Kawasaki H, Ikada Y: Promotion of fibrovascular tissue ingrowth into porous sponges by basic fibroblast growth factor. J Mater Sci Mater Med. 2000, 11: 213-218. 10.1023/A:1008960024262.CrossRefPubMed Yamamoto M, Tabata Y, Kawasaki H, Ikada Y: Promotion of fibrovascular tissue ingrowth into porous sponges by basic fibroblast growth factor. J Mater Sci Mater Med. 2000, 11: 213-218. 10.1023/A:1008960024262.CrossRefPubMed
Metadata
Title
Assessment of retention force and bone apposition in two differently coated femoral stems after 6 months of loading in a goat model
Authors
Knut Harboe
Nils R Gjerdet
Einar Sudmann
Kari Indrekvam
Kjetil Søreide
Publication date
01-12-2014
Publisher
BioMed Central
Published in
Journal of Orthopaedic Surgery and Research / Issue 1/2014
Electronic ISSN: 1749-799X
DOI
https://doi.org/10.1186/s13018-014-0069-4

Other articles of this Issue 1/2014

Journal of Orthopaedic Surgery and Research 1/2014 Go to the issue