Abstract

Background

Low risk prostate cancers are commonly treated with low dose rate (LDR) brachytherapy involving I-125 seeds. The implementation of a ‘live-planning’ technique at the Royal Adelaide Hospital (RAH) in 2007 enabled the completion of the whole procedure (i.e. scanning, planning and implant) in one sitting. ‘Live-planning’ has the advantage of a more reliable delivery of the planned treatment compared to the ‘traditional pre-plan’ technique (where patient is scanned and planned in the weeks prior to implant). During live planning, the actual implanted needle positions are updated real-time on the treatment planning system and the dosimetry is automatically recalculated. The aim of this investigation was to assess the differences and clinical relevance between the planned dosimetry and the updated real-time implant dosimetry.

Methods

A number of 162 patients were included in this dosimetric study. A paired t-test was performed on the D90, V100, V150 and V200 target parameters and the differences between the planned and implanted dose distributions were analysed. Similarly, dosimetric differences for the organs at risk (OAR) were also evaluated.

Results

Small differences between the primary dosimetric parameters for the target were found. Still, the incidence of hotspots was increased with approximately 20% for V200. Statistically significant increases were observed in the doses delivered to the OAR between the planned and implanted data; however, these increases were consistently below 3% thus probably without clinical consequences.

Conclusions

The current study assessed the accuracy of prostate implants with I-125 seeds when compared to initial plans. The results confirmed the precision of the implant technique which RAH has in place. Nevertheless, geographical misses, anatomical restrictions and needle displacements during implant can have repercussions for centres without live-planning option if dosimetric changes are not taken into consideration.
Appendix
Available only for authorised users
Literature
1.
go back to reference Kumar PP, Bartone FF: Transperineal percutaneous I-125 implant of prostate. Urology 1981,17(3):238-240. 10.1016/0090-4295(81)90037-6CrossRefPubMed Kumar PP, Bartone FF: Transperineal percutaneous I-125 implant of prostate. Urology 1981,17(3):238-240. 10.1016/0090-4295(81)90037-6CrossRefPubMed
2.
go back to reference Prada PJ, Juan G, Fernández J, González-Suárez H, Martínez A, González J, Alonso A: Conformal prostate brachytherapy guided by realtime dynamic dose calculations using permanent 125iodine implants: technical description and preliminary experience. Arch Esp Urol 2006,59(9):933-940.CrossRefPubMed Prada PJ, Juan G, Fernández J, González-Suárez H, Martínez A, González J, Alonso A: Conformal prostate brachytherapy guided by realtime dynamic dose calculations using permanent 125iodine implants: technical description and preliminary experience. Arch Esp Urol 2006,59(9):933-940.CrossRefPubMed
3.
go back to reference Sharifi N, Gulley JL, Dahut WL: Androgen deprivation therapy for prostate cancer. JAMA 2005,294(2):238-244. 10.1001/jama.294.2.238CrossRefPubMed Sharifi N, Gulley JL, Dahut WL: Androgen deprivation therapy for prostate cancer. JAMA 2005,294(2):238-244. 10.1001/jama.294.2.238CrossRefPubMed
4.
go back to reference Blasko JC, Ragde H, Schumacher D: Transperineal percutaneous Iodine-125 implantation for prostatic carcinoma using transrectal ultrasound and template guidance. Endocuerietherapy Hyperthermia Oncology 1987, 3: 131. Blasko JC, Ragde H, Schumacher D: Transperineal percutaneous Iodine-125 implantation for prostatic carcinoma using transrectal ultrasound and template guidance. Endocuerietherapy Hyperthermia Oncology 1987, 3: 131.
5.
go back to reference Grimm PD, Blasko JC, Ragde H: Ultrasound-guided transperineal implantation of Iodine-125 and Palladium-103 for the treatment of early stage prostate cancer-technical concepts in planning, operative technique, and evaluation. Atlas Ural Clin N Am 1994, 2: 113. Grimm PD, Blasko JC, Ragde H: Ultrasound-guided transperineal implantation of Iodine-125 and Palladium-103 for the treatment of early stage prostate cancer-technical concepts in planning, operative technique, and evaluation. Atlas Ural Clin N Am 1994, 2: 113.
6.
go back to reference Marcu LG, Lawson JM, Rutten T, Gowda R: Quality indicators and technique for analyzing permanent I-125 prostate seed implants: seven years postimplant dosimetry evaluation. Med Phys 2012,39(7):4123-4131. 10.1118/1.4725173CrossRefPubMed Marcu LG, Lawson JM, Rutten T, Gowda R: Quality indicators and technique for analyzing permanent I-125 prostate seed implants: seven years postimplant dosimetry evaluation. Med Phys 2012,39(7):4123-4131. 10.1118/1.4725173CrossRefPubMed
7.
go back to reference Davis BJ, Horwitz EM, Lee WR, et al.: American brachytherapy society consensus guidelines for transrectal ultrasound-guided permanent prostate brachytherapy. Brachytherapy 2012,11(1):6-19. 10.1016/j.brachy.2011.07.005CrossRefPubMed Davis BJ, Horwitz EM, Lee WR, et al.: American brachytherapy society consensus guidelines for transrectal ultrasound-guided permanent prostate brachytherapy. Brachytherapy 2012,11(1):6-19. 10.1016/j.brachy.2011.07.005CrossRefPubMed
8.
go back to reference Salembier C, Lavagnini P, Nickers P, et al.: Tumour and target volumes in permanent prostate brachytherapy: A supplement to the ESTRO/EAU/EORTC recommendations on prostate brachytherapy. Radiother Oncol 2007, 83: 3-10. 10.1016/j.radonc.2007.01.014CrossRefPubMed Salembier C, Lavagnini P, Nickers P, et al.: Tumour and target volumes in permanent prostate brachytherapy: A supplement to the ESTRO/EAU/EORTC recommendations on prostate brachytherapy. Radiother Oncol 2007, 83: 3-10. 10.1016/j.radonc.2007.01.014CrossRefPubMed
9.
go back to reference Cormack RA, Tempany CM, D’Amico AV: Optimizing target coverage by dosimetric feedback during prostate brachytherapy. Int J Radiat Oncol Biol Phys 2000,48(4):1245-1249. 10.1016/S0360-3016(00)00742-2CrossRefPubMed Cormack RA, Tempany CM, D’Amico AV: Optimizing target coverage by dosimetric feedback during prostate brachytherapy. Int J Radiat Oncol Biol Phys 2000,48(4):1245-1249. 10.1016/S0360-3016(00)00742-2CrossRefPubMed
10.
go back to reference Raben A, Chen H, Grebler A, Geltzeiler J, Geltzeiler M, Keselman I, et al.: Prostate seed implantation using 3D-computer assisted intraoperative planning vs. a standard look-up nomogram: Improved target conformality with reduction in urethral and rectal wall dose. Int J Radiat Oncol Biol Phys 2004,60(5):1631-1638. 10.1016/j.ijrobp.2004.08.003CrossRefPubMed Raben A, Chen H, Grebler A, Geltzeiler J, Geltzeiler M, Keselman I, et al.: Prostate seed implantation using 3D-computer assisted intraoperative planning vs. a standard look-up nomogram: Improved target conformality with reduction in urethral and rectal wall dose. Int J Radiat Oncol Biol Phys 2004,60(5):1631-1638. 10.1016/j.ijrobp.2004.08.003CrossRefPubMed
11.
go back to reference Stromberg J, Martinez A, Gonzales J, et al.: Ultrasound-guided high dose rate conformal brachytherapy boost in prostate cancer: Treatment description and preliminary results of a phase I/II clinical trial”. Int J Radiat Oncol Biol Phys 1995, 33: 161. 10.1016/0360-3016(95)00035-WCrossRefPubMed Stromberg J, Martinez A, Gonzales J, et al.: Ultrasound-guided high dose rate conformal brachytherapy boost in prostate cancer: Treatment description and preliminary results of a phase I/II clinical trial”. Int J Radiat Oncol Biol Phys 1995, 33: 161. 10.1016/0360-3016(95)00035-WCrossRefPubMed
12.
go back to reference Kovacs G, Galalae R, Wirth B, et al.: Optimization of interstitial brachytherapy for locally advanced prostate cancer by a new implantation technique. Strahlenther Onco 1995, 171: 685. Kovacs G, Galalae R, Wirth B, et al.: Optimization of interstitial brachytherapy for locally advanced prostate cancer by a new implantation technique. Strahlenther Onco 1995, 171: 685.
13.
go back to reference Stock RG, Stone NN, Lo YC: Intraoperative dosimetric representation of the real-time ultrasound-guided prostate in plant”. Tech Urol 2000, 6: 95.PubMed Stock RG, Stone NN, Lo YC: Intraoperative dosimetric representation of the real-time ultrasound-guided prostate in plant”. Tech Urol 2000, 6: 95.PubMed
14.
go back to reference Wilkinson DA, Lee EJ, Ciezki JP, Mohan DS, Zippe C, Angermeier K, Ulchaker J, Klein EA: Dosimetric comparison of pre-planned and or-planned prostate seed brachytherapy. Int J Radiat Oncol Biol Phys 2000,48(4):1241-1244. 10.1016/S0360-3016(00)00734-3CrossRefPubMed Wilkinson DA, Lee EJ, Ciezki JP, Mohan DS, Zippe C, Angermeier K, Ulchaker J, Klein EA: Dosimetric comparison of pre-planned and or-planned prostate seed brachytherapy. Int J Radiat Oncol Biol Phys 2000,48(4):1241-1244. 10.1016/S0360-3016(00)00734-3CrossRefPubMed
15.
go back to reference Polo A, Salembier C, Venselaar J, Hoskin P, PROBATE group of the GEC ESTRO: Review of intraoperative imaging and planning techniques in permanent seed prostate brachytherapy. Radiother Oncol 2010,94(1):12-23. 10.1016/j.radonc.2009.12.012CrossRefPubMed Polo A, Salembier C, Venselaar J, Hoskin P, PROBATE group of the GEC ESTRO: Review of intraoperative imaging and planning techniques in permanent seed prostate brachytherapy. Radiother Oncol 2010,94(1):12-23. 10.1016/j.radonc.2009.12.012CrossRefPubMed
Metadata
Title
Assessment of I-125 seed implant accuracy when using the live-planning technique for low dose rate prostate brachytherapy
Authors
Joshua Moorrees
John M Lawson
Loredana G Marcu
Publication date
01-12-2012
Publisher
BioMed Central
Published in
Radiation Oncology / Issue 1/2012
Electronic ISSN: 1748-717X
DOI
https://doi.org/10.1186/1748-717X-7-196

Other articles of this Issue 1/2012

Radiation Oncology 1/2012 Go to the issue