Skip to main content
Top
Published in: Journal of Digital Imaging 1/2012

01-02-2012

Assessment of Coronary Artery Calcium Using Dual-Energy Subtraction Digital Radiography

Authors: John N. Mafi, Baowei Fei, Sharon Roble, Anthony Dota, Prashanth Katrapati, Hiram G. Bezerra, Hesheng Wang, Wei Wang, Leslie Ciancibello, Marco Costa, Daniel I. Simon, Carl E. Orringer, Robert C. Gilkeson

Published in: Journal of Imaging Informatics in Medicine | Issue 1/2012

Login to get access

Abstract

Cardiovascular disease is the leading cause of global mortality, yet its early detection remains a vexing problem of modern medicine. Although the computed tomography (CT) calcium score predicts cardiovascular risk, relatively high cost ($250–400) and radiation dose (1–3 mSv) limit its universal utility as a screening tool. Dual-energy digital subtraction radiography (DE; <$60, 0.07 mSv) enables detection of calcified structures with high sensitivity. In this pilot study, we examined DE radiography’s ability to quantify coronary artery calcification (CAC). We identified 25 patients who underwent non-contrast CT and DE chest imaging performed within 12 months using documented CAC as the major inclusion criteria. A DE calcium score was developed based on pixel intensity multiplied by the area of the calcified plaque. DE scores were plotted against CT scores. Subsequently, a validation cohort of 14 additional patients was independently evaluated to confirm the accuracy and precision of CAC quantification, yielding a total of 39 subjects. Among all subjects (n = 39), the DE score demonstrated a correlation coefficient of 0.87 (p < 0.0001) when compared with the CT score. For the 13 patients with CT scores of <400, the correlation coefficient was −0.26. For the 26 patients with CT scores of ≥400, the correlation coefficient yielded 0.86. This pilot study demonstrates the feasibility of DE radiography to identify patients at the highest cardiovascular risk. DE radiography’s accuracy at lower scores remains unclear. Further evaluation of DE radiography as an inexpensive and low-radiation imaging tool to diagnose cardiovascular disease appears warranted.
Literature
1.
go back to reference Lloyd-Jones D, Adams RJ, Brown TM, et al: Heart disease and stroke statistics—2010 update: a report from the American Heart Association. Circulation 121(7):e46–e215, 2010PubMedCrossRef Lloyd-Jones D, Adams RJ, Brown TM, et al: Heart disease and stroke statistics—2010 update: a report from the American Heart Association. Circulation 121(7):e46–e215, 2010PubMedCrossRef
2.
go back to reference Khot UN, Khot MB, Bajzer CT, et al: Prevalence of conventional risk factors in patients with coronary heart disease. JAMA 290(7):898–904, 2003PubMedCrossRef Khot UN, Khot MB, Bajzer CT, et al: Prevalence of conventional risk factors in patients with coronary heart disease. JAMA 290(7):898–904, 2003PubMedCrossRef
3.
go back to reference Weintraub WS, Diamond GA: Predicting cardiovascular events with coronary calcium scoring. N Engl J Med 358(13):1394–1396, 2008PubMedCrossRef Weintraub WS, Diamond GA: Predicting cardiovascular events with coronary calcium scoring. N Engl J Med 358(13):1394–1396, 2008PubMedCrossRef
4.
go back to reference Agatston AS, Janowitz WR, Hildner FJ, et al: Quantification of coronary artery calcium using ultrafast computed tomography. J Am Coll Cardiol 15(4):827–832, 1990PubMedCrossRef Agatston AS, Janowitz WR, Hildner FJ, et al: Quantification of coronary artery calcium using ultrafast computed tomography. J Am Coll Cardiol 15(4):827–832, 1990PubMedCrossRef
5.
go back to reference Greenland P, Bonow RO, Brundage BH, et al: ACCF/AHA 2007 clinical expert consensus document on coronary artery calcium scoring by computed tomography in global cardiovascular risk assessment and in evaluation of patients with chest pain: a report of the American College of Cardiology Foundation Clinical Expert Consensus Task Force (ACCF/AHA Writing Committee to Update the 2000 Expert Consensus Document on Electron Beam Computed Tomography) developed in collaboration with the Society of Atherosclerosis Imaging and Prevention and the Society of Cardiovascular Computed Tomography. J Am Coll Cardiol 49(3):378–402, 2007PubMedCrossRef Greenland P, Bonow RO, Brundage BH, et al: ACCF/AHA 2007 clinical expert consensus document on coronary artery calcium scoring by computed tomography in global cardiovascular risk assessment and in evaluation of patients with chest pain: a report of the American College of Cardiology Foundation Clinical Expert Consensus Task Force (ACCF/AHA Writing Committee to Update the 2000 Expert Consensus Document on Electron Beam Computed Tomography) developed in collaboration with the Society of Atherosclerosis Imaging and Prevention and the Society of Cardiovascular Computed Tomography. J Am Coll Cardiol 49(3):378–402, 2007PubMedCrossRef
6.
go back to reference Detrano R, Guerci AD, Carr JJ, et al: Coronary calcium as a predictor of coronary events in four racial or ethnic groups. N Engl J Med 358(13):1336–1345, 2008PubMedCrossRef Detrano R, Guerci AD, Carr JJ, et al: Coronary calcium as a predictor of coronary events in four racial or ethnic groups. N Engl J Med 358(13):1336–1345, 2008PubMedCrossRef
7.
go back to reference Brenner DJ, Hall EJ: Computed tomography—an increasing source of radiation exposure. N Engl J Med 357(22):2277–2284, 2007PubMedCrossRef Brenner DJ, Hall EJ: Computed tomography—an increasing source of radiation exposure. N Engl J Med 357(22):2277–2284, 2007PubMedCrossRef
8.
go back to reference Gerber TC, Carr JJ, Arai AE, et al: Ionizing radiation in cardiac imaging: a science advisory from the american heart association committee on cardiac imaging of the council on clinical cardiology and committee on cardiovascular imaging and intervention of the council on cardiovascular radiology and intervention. Circulation 119(7):1056–1065, 2009PubMedCrossRef Gerber TC, Carr JJ, Arai AE, et al: Ionizing radiation in cardiac imaging: a science advisory from the american heart association committee on cardiac imaging of the council on clinical cardiology and committee on cardiovascular imaging and intervention of the council on cardiovascular radiology and intervention. Circulation 119(7):1056–1065, 2009PubMedCrossRef
9.
go back to reference Berrington de González A, Mahesh M, Kim K, et al: Projected cancer risks from computed tomographic scans performed in the United States in 2007. Arch Intern Med 169(22):2071–2077, 2009PubMedCrossRef Berrington de González A, Mahesh M, Kim K, et al: Projected cancer risks from computed tomographic scans performed in the United States in 2007. Arch Intern Med 169(22):2071–2077, 2009PubMedCrossRef
11.
go back to reference Fischbach F, Freund T, Röttgen R, et al: Dual-energy chest radiography with a flat-panel digital detector: revealing calcified chest abnormalities. AJR Am J Roentgenol 181(6):1519–1524, 2003PubMed Fischbach F, Freund T, Röttgen R, et al: Dual-energy chest radiography with a flat-panel digital detector: revealing calcified chest abnormalities. AJR Am J Roentgenol 181(6):1519–1524, 2003PubMed
12.
go back to reference Brody WR, Butt G, Hall A, Macovski A: A method for selective tissue and bone visualization using dual energy scanned projection radiography. Med Phys 8(3):353–357, 1981PubMedCrossRef Brody WR, Butt G, Hall A, Macovski A: A method for selective tissue and bone visualization using dual energy scanned projection radiography. Med Phys 8(3):353–357, 1981PubMedCrossRef
13.
go back to reference Hickey NM, Niklason LT, Sabbagh E, et al: Dual-energy digital radiographic quantification of calcium in simulated pulmonary nodules. AJR Am J Roentgenol 148(1):19–24, 1987PubMed Hickey NM, Niklason LT, Sabbagh E, et al: Dual-energy digital radiographic quantification of calcium in simulated pulmonary nodules. AJR Am J Roentgenol 148(1):19–24, 1987PubMed
14.
go back to reference Gilkeson RC, Novak RD, Sachs P: Digital radiography with dual-energy subtraction: improved evaluation of cardiac calcification. AJR Am J Roentgenol 183(5):1233–1238, 2004PubMed Gilkeson RC, Novak RD, Sachs P: Digital radiography with dual-energy subtraction: improved evaluation of cardiac calcification. AJR Am J Roentgenol 183(5):1233–1238, 2004PubMed
15.
go back to reference Molloi S, Detrano R, Ersahin A, Roeck W, Morcos C: Quantification of coronary arterial calcium by dual energy digital subtraction fluoroscopy. Med Phys 18(2):295–298, 1991PubMedCrossRef Molloi S, Detrano R, Ersahin A, Roeck W, Morcos C: Quantification of coronary arterial calcium by dual energy digital subtraction fluoroscopy. Med Phys 18(2):295–298, 1991PubMedCrossRef
16.
go back to reference Xu T, Ducote JL, Wong JT, Molloi S: Feasibility of real time dual-energy imaging based on a flat panel detector for coronary artery calcium quantification. Med Phys 33(6):1612–1622, 2006PubMedCrossRef Xu T, Ducote JL, Wong JT, Molloi S: Feasibility of real time dual-energy imaging based on a flat panel detector for coronary artery calcium quantification. Med Phys 33(6):1612–1622, 2006PubMedCrossRef
17.
go back to reference Brody WR, Cassel DM, Sommer FG, et al: Dual-energy projection radiography: initial clinical experience. AJR Am J Roentgenol 137(2):201–205, 1981PubMed Brody WR, Cassel DM, Sommer FG, et al: Dual-energy projection radiography: initial clinical experience. AJR Am J Roentgenol 137(2):201–205, 1981PubMed
18.
go back to reference Chen X, Gilkeson RC, Fei B: Automatic 3D-to-2D registration for CT and dual-energy digital radiography for calcification detection. Med Phys 34(12):4934–4943, 2007PubMedCrossRef Chen X, Gilkeson RC, Fei B: Automatic 3D-to-2D registration for CT and dual-energy digital radiography for calcification detection. Med Phys 34(12):4934–4943, 2007PubMedCrossRef
19.
go back to reference Fei B, Chen X, Wang H, et al: Automatic registration of CT volumes and dual-energy digital radiography for detection of cardiac and lung diseases. Conf Proc IEEE Eng Med Biol Soc 1:1976–1979, 2006PubMedCrossRef Fei B, Chen X, Wang H, et al: Automatic registration of CT volumes and dual-energy digital radiography for detection of cardiac and lung diseases. Conf Proc IEEE Eng Med Biol Soc 1:1976–1979, 2006PubMedCrossRef
20.
go back to reference Shaw LJ, Raggi P, Berman DS, Callister TQ: Cost effectiveness of screening for cardiovascular disease with measures of coronary calcium. Prog Cardiovasc Dis 46(2):171–184, 2003PubMedCrossRef Shaw LJ, Raggi P, Berman DS, Callister TQ: Cost effectiveness of screening for cardiovascular disease with measures of coronary calcium. Prog Cardiovasc Dis 46(2):171–184, 2003PubMedCrossRef
21.
go back to reference Oudkerk M, Stillman AE, Halliburton SS, et al: Coronary artery calcium screening: current status and recommendations from the European Society of Cardiac Radiology and North American Society for Cardiovascular Imaging. Int J Cardiovasc Imaging 24(6):645–671, 2008PubMedCrossRef Oudkerk M, Stillman AE, Halliburton SS, et al: Coronary artery calcium screening: current status and recommendations from the European Society of Cardiac Radiology and North American Society for Cardiovascular Imaging. Int J Cardiovasc Imaging 24(6):645–671, 2008PubMedCrossRef
22.
go back to reference Lukaski HC: Soft tissue composition and bone mineral status: evaluation by dual-energy X-ray absorptiometry. J Nutr 123(2 Suppl):438–443, 1993PubMed Lukaski HC: Soft tissue composition and bone mineral status: evaluation by dual-energy X-ray absorptiometry. J Nutr 123(2 Suppl):438–443, 1993PubMed
23.
go back to reference Mahnken AH, Wein BB, Sinha AM, Günther RW, Wildberger JE: Value of conventional chest radiography for the detection of coronary calcifications: comparison with MSCT. Eur J Radiol 69(3):510–516, 2009PubMedCrossRef Mahnken AH, Wein BB, Sinha AM, Günther RW, Wildberger JE: Value of conventional chest radiography for the detection of coronary calcifications: comparison with MSCT. Eur J Radiol 69(3):510–516, 2009PubMedCrossRef
24.
go back to reference Sakuma H, Takeda K, Hirano T, et al: Plain chest radiograph with computed radiography: improved sensitivity for the detection of coronary artery calcification. AJR Am J Roentgenol 151(1):27–30, 1988PubMed Sakuma H, Takeda K, Hirano T, et al: Plain chest radiograph with computed radiography: improved sensitivity for the detection of coronary artery calcification. AJR Am J Roentgenol 151(1):27–30, 1988PubMed
25.
go back to reference Wu M, Yang P, Huang Y, et al: Coronary arterial calcification on low-dose ungated MDCT for lung cancer screening: concordance study with dedicated cardiac CT. AJR Am J Roentgenol 190(4):923–928, 2008PubMedCrossRef Wu M, Yang P, Huang Y, et al: Coronary arterial calcification on low-dose ungated MDCT for lung cancer screening: concordance study with dedicated cardiac CT. AJR Am J Roentgenol 190(4):923–928, 2008PubMedCrossRef
Metadata
Title
Assessment of Coronary Artery Calcium Using Dual-Energy Subtraction Digital Radiography
Authors
John N. Mafi
Baowei Fei
Sharon Roble
Anthony Dota
Prashanth Katrapati
Hiram G. Bezerra
Hesheng Wang
Wei Wang
Leslie Ciancibello
Marco Costa
Daniel I. Simon
Carl E. Orringer
Robert C. Gilkeson
Publication date
01-02-2012
Publisher
Springer-Verlag
Published in
Journal of Imaging Informatics in Medicine / Issue 1/2012
Print ISSN: 2948-2925
Electronic ISSN: 2948-2933
DOI
https://doi.org/10.1007/s10278-011-9385-y

Other articles of this Issue 1/2012

Journal of Digital Imaging 1/2012 Go to the issue