Skip to main content
Top
Published in: Knee Surgery, Sports Traumatology, Arthroscopy 3/2010

01-03-2010 | Shoulder

Arthroscopic removal of proximal humerus locking plates

Authors: Joshua S. Dines, Carolyn M. Hettrich, Bryan T. Kelly, Felix H. Savoie III, Dean G. Lorich

Published in: Knee Surgery, Sports Traumatology, Arthroscopy | Issue 3/2010

Login to get access

Abstract

A technique of removing proximal humerus locking plates using an arthroscopic technique is described. Though technically demanding, benefits include smaller incisions, decreased risk of infection, and the ability to visualize and protect the axillary nerve throughout the course of the procedure. Furthermore, arthroscopy affords the surgeon with the ability to address concomitant intraarticular pathology at the time of surgery.
Literature
1.
go back to reference Brunner F, Sommer C, Bahrs C, Heuwinkel R, Hafner C, Rillmann P, Kohut G, Ekelund A, Muller M, Audige L, Babst R (2009) Open reduction and internal fixation of proximal humerus fractures using a proximal humeral locked plate: a prospective multicenter analysis. J Orthop Trauma 23:163–172CrossRefPubMed Brunner F, Sommer C, Bahrs C, Heuwinkel R, Hafner C, Rillmann P, Kohut G, Ekelund A, Muller M, Audige L, Babst R (2009) Open reduction and internal fixation of proximal humerus fractures using a proximal humeral locked plate: a prospective multicenter analysis. J Orthop Trauma 23:163–172CrossRefPubMed
2.
go back to reference Egol KA, Ong CC, Walsh M, Jazrawi LM, Tejwani NC, Zuckerman JD (2008) Early complications in proximal humerus fractures (OTA Types 11) treated with locked plates. J Orthop Trauma 22:159–164CrossRefPubMed Egol KA, Ong CC, Walsh M, Jazrawi LM, Tejwani NC, Zuckerman JD (2008) Early complications in proximal humerus fractures (OTA Types 11) treated with locked plates. J Orthop Trauma 22:159–164CrossRefPubMed
3.
go back to reference Fankhauser F, Boldin C, Schippinger G, Haunschmid C, Szyszkowitz R (2005) A new locking plate for unstable fractures of the proximal humerus. Clin Orthop Relat Res 430:176–181CrossRefPubMed Fankhauser F, Boldin C, Schippinger G, Haunschmid C, Szyszkowitz R (2005) A new locking plate for unstable fractures of the proximal humerus. Clin Orthop Relat Res 430:176–181CrossRefPubMed
4.
go back to reference Gardner MJ, Griffith MH, Dines JS, Briggs SM, Weiland AJ, Lorich DG (2005) The extended anterolateral acromial approach allows minimally invasive access to the proximal humerus. Clin Orthop Relat Res 434:123–129CrossRefPubMed Gardner MJ, Griffith MH, Dines JS, Briggs SM, Weiland AJ, Lorich DG (2005) The extended anterolateral acromial approach allows minimally invasive access to the proximal humerus. Clin Orthop Relat Res 434:123–129CrossRefPubMed
5.
go back to reference Gardner MJ, Griffith MH, Dines JS, Lorich DG (2004) A minimally invasive approach for plate fixation of the proximal humerus. Bull Hosp Jt Dis 62:18–23PubMed Gardner MJ, Griffith MH, Dines JS, Lorich DG (2004) A minimally invasive approach for plate fixation of the proximal humerus. Bull Hosp Jt Dis 62:18–23PubMed
6.
go back to reference Kirschoff C, Braunstein V, Kirschoff S et al (2008) Outcome analysis following removal of locking plate fixation of the proximal humerus. BMC 9:138 Kirschoff C, Braunstein V, Kirschoff S et al (2008) Outcome analysis following removal of locking plate fixation of the proximal humerus. BMC 9:138
7.
go back to reference Lee CW, Shin SJ (2009) Prognostic factors for unstable proximal humeral fractures treated with locking-plate fixation. J Should Elb Surg 18:83–88CrossRef Lee CW, Shin SJ (2009) Prognostic factors for unstable proximal humeral fractures treated with locking-plate fixation. J Should Elb Surg 18:83–88CrossRef
8.
go back to reference Owsley KC, Gorczyca JT (2008) Fracture displacement and screw cutout after open reduction and locked plate fixation of proximal humeral fractures. J Bone Jt Surg Am 90:233–240CrossRef Owsley KC, Gorczyca JT (2008) Fracture displacement and screw cutout after open reduction and locked plate fixation of proximal humeral fractures. J Bone Jt Surg Am 90:233–240CrossRef
9.
go back to reference Thalhammer G, Platzer P, Oberleitner G, Fialka C, Greitbauer M, Vecsei V (2009) Angular stable fixation of proximal humeral fractures. J Trauma 66:204–210CrossRefPubMed Thalhammer G, Platzer P, Oberleitner G, Fialka C, Greitbauer M, Vecsei V (2009) Angular stable fixation of proximal humeral fractures. J Trauma 66:204–210CrossRefPubMed
Metadata
Title
Arthroscopic removal of proximal humerus locking plates
Authors
Joshua S. Dines
Carolyn M. Hettrich
Bryan T. Kelly
Felix H. Savoie III
Dean G. Lorich
Publication date
01-03-2010
Publisher
Springer-Verlag
Published in
Knee Surgery, Sports Traumatology, Arthroscopy / Issue 3/2010
Print ISSN: 0942-2056
Electronic ISSN: 1433-7347
DOI
https://doi.org/10.1007/s00167-009-0991-x

Other articles of this Issue 3/2010

Knee Surgery, Sports Traumatology, Arthroscopy 3/2010 Go to the issue