Skip to main content
Top
Published in: International Orthopaedics 1/2018

01-01-2018 | Original Paper

Applicability of the AAOS appropriate-use criteria for distal radius fractures in surgical practice

Authors: Talal Ibrahim, Osama M. S. Aldahamsheh, Abdelsalam Hegazy, Hassan M. K. Ghomrawi

Published in: International Orthopaedics | Issue 1/2018

Login to get access

Abstract

Purpose

The appropriate-use criteria (AUC) for distal radius fracture (DRF) was developed by the American Academy of Orthopedic Surgeons (AAOS) to aid surgeons in making evidence-based treatment decisions for DRFs. The aim of our study was to cross-reference the management of operatively treated DRFs with the web-based AAOS published AUC recommendations.

Methods

The AUC for DRF evaluates the appropriateness of ten treatment options for each of 240 mutually exclusive patient scenarios based on the combination of five factors. For every scenario, each treatment is classified as appropriate, maybe appropriate or rarely appropriate. We retrospectively reviewed the medical charts and radiographs of all adult patients ≥19 years who underwent surgery for DRFs between 1 January and 31 December 2014 and determined the rate of appropriateness of treatment in this consecutive series of patients.

Results

Over the study period, 108 patients (83.3% men; mean age 39.8 years) with 113 DRFs (five bilateral) were treated surgically. The most frequent scenario was represented by a type C fracture, high-energy mechanism, normal functional demand, American Society Anesthesiologists (ASA) status 1–3 and no associated injuries. The most frequently used treatment was volar locking plate (54.0%). Based on the AUC, treatment was appropriate for 96 cases (85.0%), maybe appropriate for 15 (13.2%), and rarely appropriate for two (1.8%).

Conclusions

A web-based electronic AUC application can be an attractive and easy decision-making aid for orthopaedic surgeons. Application of the AUC to clinical data was relatively simple, and most operatively treated DRFs were managed appropriately.
Level of Evidence: IV.
Literature
1.
2.
go back to reference Chung KC, Shauver MJ, Yin H, Kim HM, Baser O, Birkmeyer JD (2011) Variations in the use of internal fixation for distal radial fracture in the United States medicare population. J Bone Joint Surg Am 93:2154–2162CrossRefPubMedPubMedCentral Chung KC, Shauver MJ, Yin H, Kim HM, Baser O, Birkmeyer JD (2011) Variations in the use of internal fixation for distal radial fracture in the United States medicare population. J Bone Joint Surg Am 93:2154–2162CrossRefPubMedPubMedCentral
3.
go back to reference Hammert WC, Kramer RC, Graham B, Keith MW (2013) AAOS appropriate use criteria: treatment of distal radius fractures. J Am Acad Orthop Surg 21:506–509CrossRefPubMed Hammert WC, Kramer RC, Graham B, Keith MW (2013) AAOS appropriate use criteria: treatment of distal radius fractures. J Am Acad Orthop Surg 21:506–509CrossRefPubMed
4.
go back to reference Lawson EH, Gibbons MM, Ko CY, Shekelle PG (2012) The appropriateness method has acceptable reliability and validity for assessing overuse and underuse of surgical procedures. J Clin Epidemiol 65:1133–1143CrossRefPubMed Lawson EH, Gibbons MM, Ko CY, Shekelle PG (2012) The appropriateness method has acceptable reliability and validity for assessing overuse and underuse of surgical procedures. J Clin Epidemiol 65:1133–1143CrossRefPubMed
5.
go back to reference Watters WC, Sanders JO, Murray J, Patel N (2014) The American Academy of Orthopaedic surgeons appropriate use criteria on treating distal radius fractures. J Bone Joint Surg Am 96:160–161CrossRefPubMed Watters WC, Sanders JO, Murray J, Patel N (2014) The American Academy of Orthopaedic surgeons appropriate use criteria on treating distal radius fractures. J Bone Joint Surg Am 96:160–161CrossRefPubMed
6.
go back to reference American Academy of Orthopaedic Surgeons (2013) Appropriate use criteria for treatment of distal radius fractures. Rosemont, IL, American Academy of Orthopaedic Surgeons. Available at: http://www.aaos.org/research/ Appropriate_Use/DRF_AUC.pdf. Accessed 1 April 2016 American Academy of Orthopaedic Surgeons (2013) Appropriate use criteria for treatment of distal radius fractures. Rosemont, IL, American Academy of Orthopaedic Surgeons. Available at: http://​www.​aaos.​org/​research/​ Appropriate_Use/DRF_AUC.pdf. Accessed 1 April 2016
8.
go back to reference Kyriakedes JC, Tsai E, Yu C, Hoyen HA, Malone KJ, Bafus BT (2015) Distal radius fractures: AAOS appropriate use criteria versus actual Management at a Level one Trauma Center. J. Hand. Surg. [Am.] 40:e6–e7CrossRef Kyriakedes JC, Tsai E, Yu C, Hoyen HA, Malone KJ, Bafus BT (2015) Distal radius fractures: AAOS appropriate use criteria versus actual Management at a Level one Trauma Center. J. Hand. Surg. [Am.] 40:e6–e7CrossRef
10.
go back to reference Lichtman DM, Bindra RR, Boyer MI et al (2010) Treatment of distal radius fractures. J Am Acad Orthop Surg 18:180–189CrossRefPubMed Lichtman DM, Bindra RR, Boyer MI et al (2010) Treatment of distal radius fractures. J Am Acad Orthop Surg 18:180–189CrossRefPubMed
11.
go back to reference Ghomrawi HM, Alexiades M, Pavlov H et al (2014) Evaluation of two appropriateness criteria for total knee replacement. Arthritis Care Res 66:1749–1753CrossRef Ghomrawi HM, Alexiades M, Pavlov H et al (2014) Evaluation of two appropriateness criteria for total knee replacement. Arthritis Care Res 66:1749–1753CrossRef
12.
go back to reference Ibrahim T, Hegazy A, Abulhail SI, Ghomrawi HM (2017) Utility of the AAOS appropriate use criteria (AUC) for pediatric Supracondylar Humerus fractures in clinical practice. J Pediatr Orthop 37:14–19CrossRefPubMed Ibrahim T, Hegazy A, Abulhail SI, Ghomrawi HM (2017) Utility of the AAOS appropriate use criteria (AUC) for pediatric Supracondylar Humerus fractures in clinical practice. J Pediatr Orthop 37:14–19CrossRefPubMed
13.
go back to reference Quintana JM, Arostegui I, Escobar A, Azkarate J, Goenaga JI, Lafuente I (2008) Prevalence of knee and hip osteoarthritis and the appropriateness of joint replacement in an older population. Arch Intern Med 168:1576–1584CrossRefPubMed Quintana JM, Arostegui I, Escobar A, Azkarate J, Goenaga JI, Lafuente I (2008) Prevalence of knee and hip osteoarthritis and the appropriateness of joint replacement in an older population. Arch Intern Med 168:1576–1584CrossRefPubMed
14.
go back to reference Quintana JM, Escobar A, Arostegui I et al (2006) Health-related quality of life and appropriateness of knee or hip joint replacement. Arch Intern Med 166:220–226CrossRefPubMed Quintana JM, Escobar A, Arostegui I et al (2006) Health-related quality of life and appropriateness of knee or hip joint replacement. Arch Intern Med 166:220–226CrossRefPubMed
Metadata
Title
Applicability of the AAOS appropriate-use criteria for distal radius fractures in surgical practice
Authors
Talal Ibrahim
Osama M. S. Aldahamsheh
Abdelsalam Hegazy
Hassan M. K. Ghomrawi
Publication date
01-01-2018
Publisher
Springer Berlin Heidelberg
Published in
International Orthopaedics / Issue 1/2018
Print ISSN: 0341-2695
Electronic ISSN: 1432-5195
DOI
https://doi.org/10.1007/s00264-017-3678-9

Other articles of this Issue 1/2018

International Orthopaedics 1/2018 Go to the issue