Skip to main content
Top
Published in: Surgical and Radiologic Anatomy 2/2017

01-02-2017 | Original Article

Anterior loop of the mental nerve, mental foramen and incisive nerve emergency: tridimensional assessment and surgical applications

Authors: Juan Carlos Prados-Frutos, Carmen Salinas-Goodier, Ángel Manchón, Rosa Rojo

Published in: Surgical and Radiologic Anatomy | Issue 2/2017

Login to get access

Abstract

Purpose

The aim of this study was to investigate the prevalence and length of the anterior loop (AL), the distance from this landmark to the alveolar crest and its relation with the shape of the foramen and emergency pattern in the Spanish population on helical computed tomography scan (helical CT scan) through tridimensional reconstructions.

Methods

Helical CT scan images of 41 patients aged 65 or older were analyzed. A total of 82 human hemi-mandibles were examined in this study. A tridimensional reconstruction of each mandible and Inferior Alveolar Nerve canal was created in AMIRA® software (AMIRA, Mercury Computer Systems, Berlin, Germany). Prevalence, length and distance between the AL, mental foramen and alveolar ridge were measured. This retrospective observational study was performed according to the STROBE guidelines.

Results

Prevalence of the AL was 53.7 % (n = 44) and the mean length was 1.3 ± 0.64 mm. The mean distance from the highest point of the loop to the alveolar ridge was 13.4 ± 2.8 mm. The mean diameter of the mental foramen was 3.5 ± 0.65 mm and the proportion of the oval-shaped was 62.2 % (n = 51) and round-shaped was 37.8 % (n = 31). The study found that patients with type 1 pattern emergency pattern had a higher prevalence of the AL (p = 0.03).

Conclusions

Prevalence, location and length of the anterior loop can be overlooked if only two-dimensional pre-surgical studies are performed. Therefore, three-dimensional imaging and modeling of anatomic structures should be used for the pre-operative examination of the interforaminal area. Given the wide variability of the emergency pattern of the mental nerve and the prevalence and location of the anterior loop, it should be studied in every patient individually.
Literature
1.
go back to reference Alonso MB, Cortes AR, Camargo AJ, Arita ES, Haiter-Neto F, Watanabe PC (2011) Assessment of panoramic radiomorphometric indices of the mandible in a Brazilian population. ISRN Rheumatol 854287 Alonso MB, Cortes AR, Camargo AJ, Arita ES, Haiter-Neto F, Watanabe PC (2011) Assessment of panoramic radiomorphometric indices of the mandible in a Brazilian population. ISRN Rheumatol 854287
2.
go back to reference Angelopoulos C, Thomas SL, Hechler S, Parissis N, Hlavacek M (2008) Comparison between digital panoramic radiography and cone-beam computed tomography for the identification of the mandibular canal as part of presurgical dental implant assessment. J Oral Maxillofac Surg 66:2130–2135CrossRefPubMed Angelopoulos C, Thomas SL, Hechler S, Parissis N, Hlavacek M (2008) Comparison between digital panoramic radiography and cone-beam computed tomography for the identification of the mandibular canal as part of presurgical dental implant assessment. J Oral Maxillofac Surg 66:2130–2135CrossRefPubMed
3.
go back to reference Apostolakis D, Brown JE (2012) The anterior loop of the inferior alveolar nerve: prevalence, measurement of its length and recommendation for interforaminal implant installation based on cone beam CT imaging. Clin Oral Implants Res 23:1022–1030CrossRefPubMed Apostolakis D, Brown JE (2012) The anterior loop of the inferior alveolar nerve: prevalence, measurement of its length and recommendation for interforaminal implant installation based on cone beam CT imaging. Clin Oral Implants Res 23:1022–1030CrossRefPubMed
4.
go back to reference Bavitz JB, Harn SD, Hansen CA, Lang M (1993) An anatomical study of mental neurovascular bundle-implant relationships. Int J Oral Maxillofac Implants 8:563–567PubMed Bavitz JB, Harn SD, Hansen CA, Lang M (1993) An anatomical study of mental neurovascular bundle-implant relationships. Int J Oral Maxillofac Implants 8:563–567PubMed
5.
go back to reference Benninger B, Miller D, Maharathi A, Carter W (2011) Dental implant placement investigation: is the anterior loop of the mental nerve clinically relevant? J Oral Maxillofac Surg 69:182–185CrossRefPubMed Benninger B, Miller D, Maharathi A, Carter W (2011) Dental implant placement investigation: is the anterior loop of the mental nerve clinically relevant? J Oral Maxillofac Surg 69:182–185CrossRefPubMed
6.
go back to reference Chen JC, Lin LM, Geist JR, Chen JY, Chen CH, Chen YK (2013) A retrospective comparison of the location and diameter of the inferior alveolar canal at the mental foramen and length of the anterior loop between American and Taiwanese cohorts using CBCT. Surg Radiol Anat 35:11–18CrossRefPubMed Chen JC, Lin LM, Geist JR, Chen JY, Chen CH, Chen YK (2013) A retrospective comparison of the location and diameter of the inferior alveolar canal at the mental foramen and length of the anterior loop between American and Taiwanese cohorts using CBCT. Surg Radiol Anat 35:11–18CrossRefPubMed
7.
go back to reference de Oliveira-Santos C, Souza PH, de Azambuja Berti-Couto S, Stinkens L, Moyaert K, Rubira-Bullen IR et al (2012) Assessment of variations of the mandibular canal through cone beam computed tomography. Clin Oral Investig 16:387–393CrossRefPubMed de Oliveira-Santos C, Souza PH, de Azambuja Berti-Couto S, Stinkens L, Moyaert K, Rubira-Bullen IR et al (2012) Assessment of variations of the mandibular canal through cone beam computed tomography. Clin Oral Investig 16:387–393CrossRefPubMed
8.
go back to reference Deeb GR, Dierks E, So YT (2009) Sensory nerve conduction study of the mental nerve. Muscle Nerve 23:1121–1124CrossRef Deeb GR, Dierks E, So YT (2009) Sensory nerve conduction study of the mental nerve. Muscle Nerve 23:1121–1124CrossRef
9.
go back to reference Filo K, Schneider T, Locher MC, Kruse AL, Lübbers HT (2014) The inferior alveolar nerve’s loop at the mental foramen and its implications for surgery. J Am Dent Assoc 145:260–269CrossRefPubMed Filo K, Schneider T, Locher MC, Kruse AL, Lübbers HT (2014) The inferior alveolar nerve’s loop at the mental foramen and its implications for surgery. J Am Dent Assoc 145:260–269CrossRefPubMed
10.
go back to reference Greenstein G, Tarnow D (2006) The mental foramen and nerve: clinical and anatomical factors related to dental implant placement: a literature review. J Periodontol 77:1933–1943CrossRefPubMed Greenstein G, Tarnow D (2006) The mental foramen and nerve: clinical and anatomical factors related to dental implant placement: a literature review. J Periodontol 77:1933–1943CrossRefPubMed
11.
go back to reference Hu KS, Yun HS, Hur MS, Kwon HJ, Abe S, Kim HJ (2007) Branching patterns and intraosseous course of the mental nerve. J Oral Maxillofac Surg 65:2288–2294CrossRefPubMed Hu KS, Yun HS, Hur MS, Kwon HJ, Abe S, Kim HJ (2007) Branching patterns and intraosseous course of the mental nerve. J Oral Maxillofac Surg 65:2288–2294CrossRefPubMed
12.
go back to reference Jacobs R, Mraiwa N, Van Steenberghe D, Sanderink G, Quirynen M (2004) Appearance of the mandibular incisive canal on panoramic radiographs. Surg Radiol Anat 26:329–333CrossRefPubMed Jacobs R, Mraiwa N, Van Steenberghe D, Sanderink G, Quirynen M (2004) Appearance of the mandibular incisive canal on panoramic radiographs. Surg Radiol Anat 26:329–333CrossRefPubMed
13.
go back to reference Kaya Y, Sencimen M, Sahin S, Okcu KM, Dogan N, Bahcecitapar M (2008) Retrospective radiographic evaluation of the anterior loop of the mental nerve: comparison between panoramic radiography and spiral computerized tomography. Int J Oral Maxillofac Implants 23:919–925PubMed Kaya Y, Sencimen M, Sahin S, Okcu KM, Dogan N, Bahcecitapar M (2008) Retrospective radiographic evaluation of the anterior loop of the mental nerve: comparison between panoramic radiography and spiral computerized tomography. Int J Oral Maxillofac Implants 23:919–925PubMed
14.
go back to reference Khan I, Halli R, Gadre P, Gadre KS (2011) Correlation of panoramic radiographs and spiral CT scan in the preoperative assessment of intimacy of the inferior alveolar canal to impacted mandibular third molars. J Craniofac Surg 22:566–570CrossRefPubMed Khan I, Halli R, Gadre P, Gadre KS (2011) Correlation of panoramic radiographs and spiral CT scan in the preoperative assessment of intimacy of the inferior alveolar canal to impacted mandibular third molars. J Craniofac Surg 22:566–570CrossRefPubMed
15.
go back to reference Kieser J, Kuzmanovic D, Payne A, Dennison J, Herbison P (2002) Patterns of emergence of the human mental nerve. Arch Oral Biol 47:743–747CrossRefPubMed Kieser J, Kuzmanovic D, Payne A, Dennison J, Herbison P (2002) Patterns of emergence of the human mental nerve. Arch Oral Biol 47:743–747CrossRefPubMed
16.
go back to reference Kuzmanovic DV, Payne AG, Kieser JA, Dias GJ (2003) Anterior loop of the mental nerve: a morphological and radiographic study. Clin Oral Implants Res 14:464–471CrossRefPubMed Kuzmanovic DV, Payne AG, Kieser JA, Dias GJ (2003) Anterior loop of the mental nerve: a morphological and radiographic study. Clin Oral Implants Res 14:464–471CrossRefPubMed
17.
go back to reference Lekholm U, Zarb GA. In: Patient selection and preparation. Tissue integrated prostheses: osseointegration in clinical dentistry. Branemark PI, Zarb GA, Albrektsson T, editor. Chicago: Quintessence Publishing Company y 199–209. pp 199–209 Lekholm U, Zarb GA. In: Patient selection and preparation. Tissue integrated prostheses: osseointegration in clinical dentistry. Branemark PI, Zarb GA, Albrektsson T, editor. Chicago: Quintessence Publishing Company y 199–209. pp 199–209
18.
go back to reference Li X, Jin ZK, Zhao H, Yang K, Duan JM, Wang WJ (2013) The prevalence, length and position of the anterior loop of the inferior alveolar nerve in Chinese, assessed by spiral computed tomography. Surg Radiol Anat 35:823–830CrossRefPubMed Li X, Jin ZK, Zhao H, Yang K, Duan JM, Wang WJ (2013) The prevalence, length and position of the anterior loop of the inferior alveolar nerve in Chinese, assessed by spiral computed tomography. Surg Radiol Anat 35:823–830CrossRefPubMed
19.
go back to reference Lu CI, Won J, Al-Ardah A, Santana R, Rice D, Lozada J (2015) Assessment of the anterior loop of the mental nerve using cone beam CT-scan. J Oral Implantol 41:632–639CrossRefPubMed Lu CI, Won J, Al-Ardah A, Santana R, Rice D, Lozada J (2015) Assessment of the anterior loop of the mental nerve using cone beam CT-scan. J Oral Implantol 41:632–639CrossRefPubMed
20.
go back to reference Neiva RF, Gapski R, Wang HL (2004) Morphometric analysis of implant-related anatomy in Caucasian skulls. J Periodontol 75:1061–1067CrossRefPubMed Neiva RF, Gapski R, Wang HL (2004) Morphometric analysis of implant-related anatomy in Caucasian skulls. J Periodontol 75:1061–1067CrossRefPubMed
21.
go back to reference Ngeow WC, Dionysius DD, Ishak H, Nambiar P (2009) A radiographic study on the visualization of the anterior loop in dentate subjects of different age groups. J Oral Sci 51:231–237CrossRefPubMed Ngeow WC, Dionysius DD, Ishak H, Nambiar P (2009) A radiographic study on the visualization of the anterior loop in dentate subjects of different age groups. J Oral Sci 51:231–237CrossRefPubMed
22.
go back to reference Parnia F, Moslehifard E, Hafezeqoran A, Mahboub F, Mojaver-Kahnamoui H (2012) Characteristics of anatomical landmarks in the mandibular interforaminal region: a cone-beam computed tomography study. Med Oral Patol Oral Cir Bucal 17:420–425CrossRef Parnia F, Moslehifard E, Hafezeqoran A, Mahboub F, Mojaver-Kahnamoui H (2012) Characteristics of anatomical landmarks in the mandibular interforaminal region: a cone-beam computed tomography study. Med Oral Patol Oral Cir Bucal 17:420–425CrossRef
23.
go back to reference Rosa MB, Sotto-Maior BS, de Machado V, Francischone CE (2013) Retrospective study of the anterior loop of the inferior alveolar nerve and the incisive canal using cone beam computed tomography. Int J Oral Maxillofac Implants 28:388–392CrossRefPubMed Rosa MB, Sotto-Maior BS, de Machado V, Francischone CE (2013) Retrospective study of the anterior loop of the inferior alveolar nerve and the incisive canal using cone beam computed tomography. Int J Oral Maxillofac Implants 28:388–392CrossRefPubMed
24.
go back to reference Sahman H, Sekerci AE, Sisman Y, Payveren M (2014) Assessment of the visibility and characteristics of the mandibular incisive canal: cone beam computed tomography versus panoramic radiography. Int J Oral Maxillofac Implants 29:71–78CrossRefPubMed Sahman H, Sekerci AE, Sisman Y, Payveren M (2014) Assessment of the visibility and characteristics of the mandibular incisive canal: cone beam computed tomography versus panoramic radiography. Int J Oral Maxillofac Implants 29:71–78CrossRefPubMed
25.
go back to reference Sankar DK, Bhanu SP, Susan PJ (2011) Morphometrical and morphological study of mental foramen in dry dentulous mandibles of South Andhra population of India. Indian J Dent Res 22:542–546CrossRefPubMed Sankar DK, Bhanu SP, Susan PJ (2011) Morphometrical and morphological study of mental foramen in dry dentulous mandibles of South Andhra population of India. Indian J Dent Res 22:542–546CrossRefPubMed
26.
go back to reference Uchida Y, Noguchi N, Goto M, Yamashita Y, Hanihara T, Takamori H et al (2009) Measurement of anterior loop length for the mandibular canal and diameter of the mandibular incisive canal to avoid nerve damage when installing endosseous implants in the interforaminal region: a second attempt introducing cone beam computed tomography. J Oral Maxillofac Surg 67:744–750CrossRefPubMed Uchida Y, Noguchi N, Goto M, Yamashita Y, Hanihara T, Takamori H et al (2009) Measurement of anterior loop length for the mandibular canal and diameter of the mandibular incisive canal to avoid nerve damage when installing endosseous implants in the interforaminal region: a second attempt introducing cone beam computed tomography. J Oral Maxillofac Surg 67:744–750CrossRefPubMed
27.
go back to reference von Arx T, Häfliger J, Chappuis V (2005) Neurosensory disturbances following bone harvesting in the symphysis: a prospective clinical study. Clin Oral Implants Res 16:432–439CrossRef von Arx T, Häfliger J, Chappuis V (2005) Neurosensory disturbances following bone harvesting in the symphysis: a prospective clinical study. Clin Oral Implants Res 16:432–439CrossRef
28.
go back to reference von Elm E, Altman DG, Egger M, Pocock SJ, Gøtzsche PC, Vandenbroucke JP, y Initiative., STROBE (2008) The Strengthening the Reporting of Observational Studies in Epidemiology (STROBE)statement: guidelines for reporting observational studies. J Clin Epidemiol 61(4):344–349CrossRef von Elm E, Altman DG, Egger M, Pocock SJ, Gøtzsche PC, Vandenbroucke JP, y Initiative., STROBE (2008) The Strengthening the Reporting of Observational Studies in Epidemiology (STROBE)statement: guidelines for reporting observational studies. J Clin Epidemiol 61(4):344–349CrossRef
29.
go back to reference Vujanovic-Eskenazi A, Valero-James JM, Sánchez-Garcés MA, Gay-Escoda C (2015) A retrospective radiographic evaluation of the anterior loop of the mental nerve: comparison between panoramic radiography and cone beam computerized tomography. Med Oral Patol Oral Cir Bucal 20:239–245CrossRef Vujanovic-Eskenazi A, Valero-James JM, Sánchez-Garcés MA, Gay-Escoda C (2015) A retrospective radiographic evaluation of the anterior loop of the mental nerve: comparison between panoramic radiography and cone beam computerized tomography. Med Oral Patol Oral Cir Bucal 20:239–245CrossRef
30.
go back to reference Watanabe H, Mohammad Abdul M, Kurabayashi T, Aoki H (2010) Mandible size and morphology determined wit. CT on a premise of dental implant operation. Surg Radiol Anat 32:343–349CrossRefPubMed Watanabe H, Mohammad Abdul M, Kurabayashi T, Aoki H (2010) Mandible size and morphology determined wit. CT on a premise of dental implant operation. Surg Radiol Anat 32:343–349CrossRefPubMed
Metadata
Title
Anterior loop of the mental nerve, mental foramen and incisive nerve emergency: tridimensional assessment and surgical applications
Authors
Juan Carlos Prados-Frutos
Carmen Salinas-Goodier
Ángel Manchón
Rosa Rojo
Publication date
01-02-2017
Publisher
Springer Paris
Published in
Surgical and Radiologic Anatomy / Issue 2/2017
Print ISSN: 0930-1038
Electronic ISSN: 1279-8517
DOI
https://doi.org/10.1007/s00276-016-1690-1

Other articles of this Issue 2/2017

Surgical and Radiologic Anatomy 2/2017 Go to the issue