Anterior chamber indices in a population-based study using the Pentacam

Authors: Hassan Hashemi, AbbasAli Yekta, Farzad Khodamoradi, Mohamadreza Aghamirsalim, Amir Asharlous, Mehrdad Assadpour, Mehdi Khabazkhoob

Published in: International Ophthalmology | Issue 9/2019

Login to get access

Abstract

Purpose

To determine the distribution of anterior chamber depth (ACD), anterior chamber volume (ACV), and anterior chamber angle (ACA) values in a rural population over 5 years of age using the Pentacam.

Methods

In this cross-sectional study, samples were selected from over 1-year-old inhabitants of two villages in Iran using a multistage cluster sampling approach. All participants underwent the measurement of uncorrected and corrected visual acuity and auto-refraction, retinoscopy, subjective refraction, and slit lamp examination. Finally, corneal imaging was done for all subjects over 5 years of age using the Pentacam.

Results

Of 3851 selected individuals, 3314 participated in the study, of whom 2681 met the inclusion criteria. The mean age of the sample was 36.03 ± 18.5 years (range 6–90 years). The mean ACD, ACA, and ACV values were 3.37 mm (95% CI: 3.37–3.39), 34.82° (95% CI: 34.45–35.2), and 159.17 µL (95% CI: 156–161.36), respectively. The results of multiple linear regression models showed that ACD, ACA, and ACV values reduced with age, and ACD and ACV values were significantly higher in males. ACA and ACV values correlated inversely with central corneal thickness, while the ACA value correlated directly with keratometry and inversely with the ACV value.

Conclusion

This study is one of the few studies in the world showing changes in ACD values in different age groups using the Pentacam. According to the results, aging was associated with a decline in the mean ACD, ACA, and ACV values. These parameters were the largest in patients with emmetropia and smallest in hyperopic subjects.
Literature
6.
go back to reference Barrett BT, McGraw PV, Murray LA et al (1996) Anterior chamber depth measurement in clinical practice. Optom Vis Sci 73:482–486CrossRefPubMed Barrett BT, McGraw PV, Murray LA et al (1996) Anterior chamber depth measurement in clinical practice. Optom Vis Sci 73:482–486CrossRefPubMed
18.
go back to reference Fontana ST, Brubaker RF (1980) Volume and depth of the anterior chamber in the normal aging human eye. Arch Ophthalmol 98:1803–1808CrossRefPubMed Fontana ST, Brubaker RF (1980) Volume and depth of the anterior chamber in the normal aging human eye. Arch Ophthalmol 98:1803–1808CrossRefPubMed
21.
go back to reference Maeng H-SRE, Chung T-Y, Chung E-S (2010) Effects of anterior chamber depth and axial length on refractive error after intraocular lens implantation. J Korean Ophthalmol Soc 51:195–202CrossRef Maeng H-SRE, Chung T-Y, Chung E-S (2010) Effects of anterior chamber depth and axial length on refractive error after intraocular lens implantation. J Korean Ophthalmol Soc 51:195–202CrossRef
29.
go back to reference Dinc U, Oncel B, Gorgun E et al (2009) Quantitative assessment of anterior chamber volume using slit-lamp OCT and Pentacam. Eur J Ophthalmol 19:411–415CrossRefPubMed Dinc U, Oncel B, Gorgun E et al (2009) Quantitative assessment of anterior chamber volume using slit-lamp OCT and Pentacam. Eur J Ophthalmol 19:411–415CrossRefPubMed
31.
go back to reference Auffarth GU, Tetz MR, Biazid Y et al (1997) Measuring anterior chamber depth with Orbscan Topography System. J Cataract Refract Surg 23:1351–1355CrossRefPubMed Auffarth GU, Tetz MR, Biazid Y et al (1997) Measuring anterior chamber depth with Orbscan Topography System. J Cataract Refract Surg 23:1351–1355CrossRefPubMed
32.
go back to reference Lackner B, Schmidinger G, Skorpik C (2005) Validity and repeatability of anterior chamber depth measurements with Pentacam and Orbscan. Optom Vis Sci 82:858–861CrossRefPubMed Lackner B, Schmidinger G, Skorpik C (2005) Validity and repeatability of anterior chamber depth measurements with Pentacam and Orbscan. Optom Vis Sci 82:858–861CrossRefPubMed
33.
go back to reference Hashemi H, Khabazkhoob M, Miraftab M et al (2012) The distribution of axial length, anterior chamber depth, lens thickness, and vitreous chamber depth in an adult population of Shahroud, Iran. BMC Ophthalmol 12:50CrossRefPubMedPubMedCentral Hashemi H, Khabazkhoob M, Miraftab M et al (2012) The distribution of axial length, anterior chamber depth, lens thickness, and vitreous chamber depth in an adult population of Shahroud, Iran. BMC Ophthalmol 12:50CrossRefPubMedPubMedCentral
Metadata
Title
Anterior chamber indices in a population-based study using the Pentacam
Authors
Hassan Hashemi
AbbasAli Yekta
Farzad Khodamoradi
Mohamadreza Aghamirsalim
Amir Asharlous
Mehrdad Assadpour
Mehdi Khabazkhoob
Publication date
01-09-2019
Publisher
Springer Netherlands
Published in
International Ophthalmology / Issue 9/2019
Print ISSN: 0165-5701
Electronic ISSN: 1573-2630
DOI
https://doi.org/10.1007/s10792-018-1037-5

Other articles of this Issue 9/2019

International Ophthalmology 9/2019 Go to the issue