Skip to main content
Top
Published in: European Spine Journal 6/2013

01-11-2013 | Original Article

Anterior cervical fusion for radicular-disc conflict performed by three different procedures: clinical and radiographic analysis at long-term follow-up

Authors: A. Zagra, L. Zagra, L. Scaramuzzo, L. Minoia, M. Archetti, F. Giudici

Published in: European Spine Journal | Special Issue 6/2013

Login to get access

Abstract

Purpose

Purpose of the study was to analyze in a retrospective way the clinical and radiographic outcome of three different surgical techniques in patients who underwent anterior cervical fusion.

Methods

Eighty-six patients affected by symptomatic cervical disc herniation or spondylosis underwent cervical anterior fusion. Patients were divided in three groups considering the surgical technique. Clinical outcomes were evaluated by Visual Analog Scale, Odom’s criteria, Neck Disability Index. Radiographic evaluation included standard and functional X-rays.

Results

At 7 years mean follow-up, a comparable improvement in clinical symptoms was observed in all groups. Radiographic findings showed a solid fusion in all patients but seven cases in group 2 showed a subsidence of the cage.

Conclusions

As shown by the obtained clinical and radiographic results, the anterior interbody fusion with stand-alone peek cage containing β-tricalcium phosphate could be considered an effective and reliable procedure.
Literature
1.
go back to reference Robinson RA, Smith GW (1955) Anterolateral disc removal and interbody fusion for cervical disc syndrome. Bull Johns Hopkins Hosp 96:223–224 Robinson RA, Smith GW (1955) Anterolateral disc removal and interbody fusion for cervical disc syndrome. Bull Johns Hopkins Hosp 96:223–224
2.
3.
go back to reference Caspar WB, Klara DD (1989) Anterior cervical fusion and Caspar plate stabilization for cervical trauma. Neurosurgery 25:491–502PubMedCrossRef Caspar WB, Klara DD (1989) Anterior cervical fusion and Caspar plate stabilization for cervical trauma. Neurosurgery 25:491–502PubMedCrossRef
4.
go back to reference Morsher E, Sutter F, Jenny H et al (1986) Anterior plating of the cervical spine with the hollow screw-plate system of titanium. Chirurg 57:702–707 Morsher E, Sutter F, Jenny H et al (1986) Anterior plating of the cervical spine with the hollow screw-plate system of titanium. Chirurg 57:702–707
5.
go back to reference Orozco DR, Llovet TR (1971) Osteosintesis en las lesions traumaticas y degeneratives de la columna vertebral. Revista Traumatol Chirurg Rehabil 1:45–52 Orozco DR, Llovet TR (1971) Osteosintesis en las lesions traumaticas y degeneratives de la columna vertebral. Revista Traumatol Chirurg Rehabil 1:45–52
6.
go back to reference Christodoulou A, Ploumis A, Terzidis I et al (2004) Combined interbody cage and anterior plating in the surgical treatment of cervical disc disease. Acta Orthop Belg 70:461–465PubMed Christodoulou A, Ploumis A, Terzidis I et al (2004) Combined interbody cage and anterior plating in the surgical treatment of cervical disc disease. Acta Orthop Belg 70:461–465PubMed
7.
go back to reference Hacker RJ, Cauthen JC, Gilbert TJ et al (2000) A prospective randomized multicenter clinical evaluation of an anterior cervical fusion cage. Spine (Phila pha 1976) 25:2646–2655CrossRef Hacker RJ, Cauthen JC, Gilbert TJ et al (2000) A prospective randomized multicenter clinical evaluation of an anterior cervical fusion cage. Spine (Phila pha 1976) 25:2646–2655CrossRef
8.
go back to reference Samandouras G, Shafafy M, Hamlyn PJ (2001) A new anterior cervical instrumentation system combining an intradiscal cage with an integrated plate: an early technical report. Spine (Phila pha) 26:1188–1192CrossRef Samandouras G, Shafafy M, Hamlyn PJ (2001) A new anterior cervical instrumentation system combining an intradiscal cage with an integrated plate: an early technical report. Spine (Phila pha) 26:1188–1192CrossRef
9.
go back to reference Cho DY, Lee WY, Sheu PC et al (2005) Cage containing a biphasic calcium phosphate ceramic (triosite) for the treatment of cervical spondylosis. Surg Neurol 63:497–504PubMedCrossRef Cho DY, Lee WY, Sheu PC et al (2005) Cage containing a biphasic calcium phosphate ceramic (triosite) for the treatment of cervical spondylosis. Surg Neurol 63:497–504PubMedCrossRef
10.
go back to reference Gercek E, Arlet V, Delisle J et al (2003) Subsidence of stand-alone cervical cages in anterior interbody fusion: warning. Eur Spine J 12:513–516PubMedCrossRef Gercek E, Arlet V, Delisle J et al (2003) Subsidence of stand-alone cervical cages in anterior interbody fusion: warning. Eur Spine J 12:513–516PubMedCrossRef
11.
go back to reference Bartles RH, Donk RD, Feuth T (2006) Subsidence of stand-alone cervical carbon fiber cage. Neurosurgery 58:502–508CrossRef Bartles RH, Donk RD, Feuth T (2006) Subsidence of stand-alone cervical carbon fiber cage. Neurosurgery 58:502–508CrossRef
12.
go back to reference Day LY, Jiang LS (2008) Anterior cervical fusion with interbody cage containing B-tricalcium phosphate augmented with plate fixation. A prospective randomized study with 2-year follow up. Eur Spine J 17:698–705CrossRef Day LY, Jiang LS (2008) Anterior cervical fusion with interbody cage containing B-tricalcium phosphate augmented with plate fixation. A prospective randomized study with 2-year follow up. Eur Spine J 17:698–705CrossRef
13.
go back to reference Matge G (1998) Anterior interbody fusion with the BAK-cage in cervical spondylosis. Acta Neurochir 140:1–8PubMedCrossRef Matge G (1998) Anterior interbody fusion with the BAK-cage in cervical spondylosis. Acta Neurochir 140:1–8PubMedCrossRef
14.
go back to reference Santos ER, Gross DG, Morcom RK et al (2003) Radiologic assessment of interbody fusion using carbon fiber cages. Spine (Phila pha) 28:997–1001 Santos ER, Gross DG, Morcom RK et al (2003) Radiologic assessment of interbody fusion using carbon fiber cages. Spine (Phila pha) 28:997–1001
15.
go back to reference Bartles RH, Donk RD, Van Azn RD (2001) Height of cervical foramina after anterior discectomy and implantation of a carbon fiber cage. J Neurosurg 95(1 Suppl):40–42 Bartles RH, Donk RD, Van Azn RD (2001) Height of cervical foramina after anterior discectomy and implantation of a carbon fiber cage. J Neurosurg 95(1 Suppl):40–42
16.
go back to reference Payer M, May D, Reverdin A et al (2003) Implantation of an empty carbon fiber composite frame cage after single-level anterior cervical discectomy in the treatment of cervical disc herniation: preliminary results. J Neurosurg 98:143–148PubMed Payer M, May D, Reverdin A et al (2003) Implantation of an empty carbon fiber composite frame cage after single-level anterior cervical discectomy in the treatment of cervical disc herniation: preliminary results. J Neurosurg 98:143–148PubMed
17.
go back to reference Agrillo U, Mastronardi L, Puzzilli F (2002) Anterior cervical fusion with carbon fiber cages containing coralline hydroxyapatite: preliminary observations in 45 consecutive cases of soft-disc herniation. J Neurosurg 96:273–276PubMed Agrillo U, Mastronardi L, Puzzilli F (2002) Anterior cervical fusion with carbon fiber cages containing coralline hydroxyapatite: preliminary observations in 45 consecutive cases of soft-disc herniation. J Neurosurg 96:273–276PubMed
18.
go back to reference Shah RR, Mohammed S, Saifuddin A et al (2003) Comparison of plain radiographs with CT scan to evaluate interbody fusion following the use of titanium interbody cages and transpedicular instrumentation. Eur Spine J 12:378–385PubMedCrossRef Shah RR, Mohammed S, Saifuddin A et al (2003) Comparison of plain radiographs with CT scan to evaluate interbody fusion following the use of titanium interbody cages and transpedicular instrumentation. Eur Spine J 12:378–385PubMedCrossRef
19.
go back to reference Shimamoto N, Cunningham BW, Dmitriev AE et al (2001) Biomechanical evaluation of stand-alone interbody fusion cages in the cervical spine. Spine (Phila pha) 26:432–436CrossRef Shimamoto N, Cunningham BW, Dmitriev AE et al (2001) Biomechanical evaluation of stand-alone interbody fusion cages in the cervical spine. Spine (Phila pha) 26:432–436CrossRef
Metadata
Title
Anterior cervical fusion for radicular-disc conflict performed by three different procedures: clinical and radiographic analysis at long-term follow-up
Authors
A. Zagra
L. Zagra
L. Scaramuzzo
L. Minoia
M. Archetti
F. Giudici
Publication date
01-11-2013
Publisher
Springer Berlin Heidelberg
Published in
European Spine Journal / Issue Special Issue 6/2013
Print ISSN: 0940-6719
Electronic ISSN: 1432-0932
DOI
https://doi.org/10.1007/s00586-013-3006-z

Other articles of this Special Issue 6/2013

European Spine Journal 6/2013 Go to the issue