Skip to main content
Top
Published in: Archives of Orthopaedic and Trauma Surgery 5/2021

01-05-2021 | Ankle Bone Fracture | Trauma Surgery

Inducing pilon fractures in human cadaveric specimens depending on the injury mechanism: a fracture simulation

Authors: N. Ott, A. Harbrecht, M. Hackl, T. Leschinger, J. Knifka, L. P. Müller, K. Wegmann

Published in: Archives of Orthopaedic and Trauma Surgery | Issue 5/2021

Login to get access

Abstract

Background

Operative management of pilon fractures, especially high-energy compression injuries, is a challenge. Operative education is of vital importance to handle these entities. Not rarely, it is cut by economics and staff shortage. As public awareness toward operative competence rises, surgical cadaver courses that provide pre-fractured specimens can improve realism of teaching scenarios. The aim of this study is to introduce a realistic pilon fracture simulation setup regarding the injury mechanism.

Materials and methods

8 cadaveric specimens (two left, six right) were fixed onto a custom drop-test bench in dorsiflexion (20°) and light supination (10°). The proximal part of the lower leg was potted, and the specimen was exposed to a high energetic impulse via an axial impactor. CT imaging was performed after fracture simulation to detect the exact fracture patterns and to classify the achieved fractures by two independent trauma surgeons. (AO/OTA recommendations and the Rüedi/Allgöwer).

Results

All cadaveric specimens could be successfully fractured: 6 (75%) were identified as a 43-C fracture and 2 (25%) as 43-B fracture type. Regardless of the identical mechanism two different kinds of fracture types were reported. In five cases (62.5%), the fibula was also fractured and in three specimens, a talus fracture was described. There was no statistically significant correlation found regarding Hounsfield Units (HU) and age as well as HU and required kinetic energy.

Conclusion

A high energetic axial impulse on a fixed ankle specimen in light dorsiflexion (20°) and supination (10°) induced by a custom-made drop-test bench can successfully simulate realistic pilon fractures in cadaveric specimens with intact soft tissue envelope. Although six out of eight fractures (75%) were classified as a 43-C fracture and despite putting a lot of effort into the mechanical setup, we could not achieve an absolute level of precision. Therefore, we suggest that the injury mechanism is most likely a combination of axial loading, shear and rotation.

Level of evidence

III
Literature
1.
go back to reference Atesok K, Mabrey JD, Jazrawi LM, Egol KA (2012) Surgical simulation in orthopaedic skills training. J Am Acad Orthop Sur 20(7):410–422 Atesok K, Mabrey JD, Jazrawi LM, Egol KA (2012) Surgical simulation in orthopaedic skills training. J Am Acad Orthop Sur 20(7):410–422
2.
go back to reference Blauth M, Bastian L, Krettek C, Knop C, Evans S (2001) Surgical options for the treatment of severe tibial pilon fractures: a study of three techniques. J Orthop Trauma 15(3):153–160CrossRef Blauth M, Bastian L, Krettek C, Knop C, Evans S (2001) Surgical options for the treatment of severe tibial pilon fractures: a study of three techniques. J Orthop Trauma 15(3):153–160CrossRef
3.
go back to reference Bonar SK, Marsh JL (1994) Tibial plafond fractures: changing principles of treatment. J Am Acad Orthop Surg 2:297–306CrossRef Bonar SK, Marsh JL (1994) Tibial plafond fractures: changing principles of treatment. J Am Acad Orthop Surg 2:297–306CrossRef
4.
go back to reference Darzi SA, Munz Y (2004) The impact of minimally invasive surgical techniques. Annu Rev Med 55:223–237CrossRef Darzi SA, Munz Y (2004) The impact of minimally invasive surgical techniques. Annu Rev Med 55:223–237CrossRef
5.
go back to reference Gilbody J, Prasthofer AW, Ho K, Costa ML (2011) The use and effectiveness of cadaveric workshops in higher surgical training: a systematic review. Ann R Coll Surg Engl 93(5):347–352CrossRef Gilbody J, Prasthofer AW, Ho K, Costa ML (2011) The use and effectiveness of cadaveric workshops in higher surgical training: a systematic review. Ann R Coll Surg Engl 93(5):347–352CrossRef
6.
go back to reference Holland JP, Waugh L, Horgan A, Paleri V, Deehan DJ (2011) Cadaveric hands-on training for surgical specialties: is this back to the future for surgical skills development? J Surg Educ 68(2):110–116CrossRef Holland JP, Waugh L, Horgan A, Paleri V, Deehan DJ (2011) Cadaveric hands-on training for surgical specialties: is this back to the future for surgical skills development? J Surg Educ 68(2):110–116CrossRef
7.
go back to reference Kuhls DA, Risucci DA, Bowyer MW, Luchette FA (2013) Advanced surgical skills for exposure in trauma: a new surgical skills cadaver course for surgery residents and fellows. J Trauma Acute Care Surg 74(2):664–670CrossRef Kuhls DA, Risucci DA, Bowyer MW, Luchette FA (2013) Advanced surgical skills for exposure in trauma: a new surgical skills cadaver course for surgery residents and fellows. J Trauma Acute Care Surg 74(2):664–670CrossRef
8.
go back to reference Lauge-Hansen N (1953) Fractures of the ankleV: pronation-dorsiflexion fractures. Arch Surg 67:813–820CrossRef Lauge-Hansen N (1953) Fractures of the ankleV: pronation-dorsiflexion fractures. Arch Surg 67:813–820CrossRef
9.
go back to reference Lee S, Chung CK, Oh SH, Park SB (2013) Correlation between bone mineral density measured by dual-energy X-ray absorptiometry and Hounsfield units measured by diagnostic CT in lumbar spine. J Korean Neurosurg S 54(5):384–389CrossRef Lee S, Chung CK, Oh SH, Park SB (2013) Correlation between bone mineral density measured by dual-energy X-ray absorptiometry and Hounsfield units measured by diagnostic CT in lumbar spine. J Korean Neurosurg S 54(5):384–389CrossRef
10.
go back to reference Martin JS, Marsh JL, Bonar SK, DeCoster TA, Found EM, Brandser EA (1997) Assessment of the AO/ASIF fracture classification for the distal tibia. J Orthop Trauma 11:477–483CrossRef Martin JS, Marsh JL, Bonar SK, DeCoster TA, Found EM, Brandser EA (1997) Assessment of the AO/ASIF fracture classification for the distal tibia. J Orthop Trauma 11:477–483CrossRef
11.
go back to reference Nutt J, Mehdian R, Parkin I, Dent J, Kellett C (2012) Cadaveric surgery: a novel approach to teaching clinical anatomy. Clin Teach 9(3):148–151CrossRef Nutt J, Mehdian R, Parkin I, Dent J, Kellett C (2012) Cadaveric surgery: a novel approach to teaching clinical anatomy. Clin Teach 9(3):148–151CrossRef
12.
go back to reference Patel SP, Lee JJ, Hecht GG, Holcombe SA, Wang SC, Goulet JA (2016) Normative vertebral Hounsfield unit values and correlation with bone mineral density. J Clin Exp Orthopaed 2(114):1–7 Patel SP, Lee JJ, Hecht GG, Holcombe SA, Wang SC, Goulet JA (2016) Normative vertebral Hounsfield unit values and correlation with bone mineral density. J Clin Exp Orthopaed 2(114):1–7
13.
go back to reference Pellegrini CA (2006) Surgical education in the United States: navigating the white waters. Ann Surg 244(3):335–342CrossRef Pellegrini CA (2006) Surgical education in the United States: navigating the white waters. Ann Surg 244(3):335–342CrossRef
14.
go back to reference Pennington DG (2006) The impact of new technology on cardiothoracic surgical practice. Ann Thorac Surg 81(1):10–18CrossRef Pennington DG (2006) The impact of new technology on cardiothoracic surgical practice. Ann Thorac Surg 81(1):10–18CrossRef
15.
go back to reference Ruedi T, Allgower M (1969) Fractures of the lower end of the tibia into the ankle-joint. Injury 1:92CrossRef Ruedi T, Allgower M (1969) Fractures of the lower end of the tibia into the ankle-joint. Injury 1:92CrossRef
16.
go back to reference Ruedi TP, Allgower M (1979) The operative treatment of intra-articular fractures of the lower end of the tibia. Clin Orthop 138:105–110 Ruedi TP, Allgower M (1979) The operative treatment of intra-articular fractures of the lower end of the tibia. Clin Orthop 138:105–110
17.
go back to reference Schreiber JJ, Anderson PA, Hsu WK (2014) Use of computed tomography for assessing bone mineral density. Neurosurg Focus 37(1):E4CrossRef Schreiber JJ, Anderson PA, Hsu WK (2014) Use of computed tomography for assessing bone mineral density. Neurosurg Focus 37(1):E4CrossRef
18.
go back to reference Schwindel L, Statton J, Porta D, Kress T, Robers CS (2007) Can pilon fractures be created in vitro? A biomechnical study of axial loading. OsteoTraumaCare 15:128–130 Schwindel L, Statton J, Porta D, Kress T, Robers CS (2007) Can pilon fractures be created in vitro? A biomechnical study of axial loading. OsteoTraumaCare 15:128–130
19.
go back to reference Swiontkowski MF, Sands AK, Agel J, Diab M, Schwappach JR, Kreder HJ (1997) Interobserver variation in the AO/OTA fracture classication system for pilon fractures: is there a problem? J Orthop Trauma 11:467–470CrossRef Swiontkowski MF, Sands AK, Agel J, Diab M, Schwappach JR, Kreder HJ (1997) Interobserver variation in the AO/OTA fracture classication system for pilon fractures: is there a problem? J Orthop Trauma 11:467–470CrossRef
20.
go back to reference Tornetta P, Weiner L, Bergman M et al (1993) Pilon fractures: treatment with combined internal and external fixation. J Orthop Trauma 7:489–496CrossRef Tornetta P, Weiner L, Bergman M et al (1993) Pilon fractures: treatment with combined internal and external fixation. J Orthop Trauma 7:489–496CrossRef
21.
go back to reference Wegmann K, Engel K, Burkhart KJ, Ebinger M, Holz R, Bruggemann GP, Muller LP (2014) Sequence of the Essex-Lopresti lesion—a high-speed video documentation and kinematic analysis. Acta Orthop 85(2):177–180CrossRef Wegmann K, Engel K, Burkhart KJ, Ebinger M, Holz R, Bruggemann GP, Muller LP (2014) Sequence of the Essex-Lopresti lesion—a high-speed video documentation and kinematic analysis. Acta Orthop 85(2):177–180CrossRef
23.
go back to reference Wegmann K, Rausch V, Burkhart KJ, Hackl M, Leschinger T, Muller L (2019) Advanced surgical trauma care course—evaluation of a fracture simulation course concept with intact soft tissue. Z Orthop Unfall 158(3):291–297CrossRef Wegmann K, Rausch V, Burkhart KJ, Hackl M, Leschinger T, Muller L (2019) Advanced surgical trauma care course—evaluation of a fracture simulation course concept with intact soft tissue. Z Orthop Unfall 158(3):291–297CrossRef
Metadata
Title
Inducing pilon fractures in human cadaveric specimens depending on the injury mechanism: a fracture simulation
Authors
N. Ott
A. Harbrecht
M. Hackl
T. Leschinger
J. Knifka
L. P. Müller
K. Wegmann
Publication date
01-05-2021
Publisher
Springer Berlin Heidelberg
Published in
Archives of Orthopaedic and Trauma Surgery / Issue 5/2021
Print ISSN: 0936-8051
Electronic ISSN: 1434-3916
DOI
https://doi.org/10.1007/s00402-020-03538-9

Other articles of this Issue 5/2021

Archives of Orthopaedic and Trauma Surgery 5/2021 Go to the issue