Abstract

Drug-eluting stent (DES) failure and conditions thereafter remain issues of concern despite generational advancements in DES technology. Registry data and pathological investigations have shown a variety of causes of late stent thrombosis and very late stent thrombosis. On the other hand, clinical imaging including serial studies can provide information on the conditions during the event, the previous status of the lesion, and the healing process after stent implantation. Therefore we investigated thrombus-related DES failure using coronary angioscopy (CAS), which is a robust tool for thrombus assessment. Five out of 8 thrombotic DES failures were documented during urgent repeat percutaneous coronary intervention (repeat PCI). Four patients underwent CAS before the event, and 5 patients were followed using CAS after repeat PCI for DES failure. Among these cases, there were data before and after the event in 4 patients, which highlighted various patterns of healing after repeat PCI for thrombus-related DES failure, including erosion and yellow plaque underneath the DES. The cause of thrombus formation in this series was delayed healing process, but other possible triggers included restenosis, insufficient DAPT duration, neoatherosclerosis, and vasospasm. In addition to these findings being consistent with previous segmental postmortem studies, invasive imaging modalities can provide data on more than just the event itself, such as sequential comparison and lesion features of the survivor. Accumulation of this knowledge would contribute to generating new hypothesis in the future.
Literature
1.
go back to reference Kimura T, Morimoto T, Nakagawa Y, Tamura T, Kadota K, Yasumoto H, et al. Antiplatelet therapy and stent thrombosis after sirolimus-eluting stent implantation. Circulation. 2009;119:987–95.PubMedCrossRef Kimura T, Morimoto T, Nakagawa Y, Tamura T, Kadota K, Yasumoto H, et al. Antiplatelet therapy and stent thrombosis after sirolimus-eluting stent implantation. Circulation. 2009;119:987–95.PubMedCrossRef
2.
go back to reference Raber L, Magro M, Stefanini GG, Kalesan B, van Domburg RT, Onuma Y, et al. Very late coronary stent thrombosis of a newer-generation everolimus-eluting stent compared with early-generation drug-eluting stents a prospective cohort study. Circulation. 2012;125:1110–21.PubMedCrossRef Raber L, Magro M, Stefanini GG, Kalesan B, van Domburg RT, Onuma Y, et al. Very late coronary stent thrombosis of a newer-generation everolimus-eluting stent compared with early-generation drug-eluting stents a prospective cohort study. Circulation. 2012;125:1110–21.PubMedCrossRef
3.
go back to reference Lüscher TF, Steffel J, Eberli FR, Joner M, Nakazawa G, Tanner FC, et al. Drug-eluting stent and coronary thrombosis biological mechanisms and clinical implications. Circulation. 2007;115:1051–8.PubMedCrossRef Lüscher TF, Steffel J, Eberli FR, Joner M, Nakazawa G, Tanner FC, et al. Drug-eluting stent and coronary thrombosis biological mechanisms and clinical implications. Circulation. 2007;115:1051–8.PubMedCrossRef
4.
go back to reference Kimura T, Morimoto T, Kozuma K, Honda Y, Kume T, Aizawa T, et al. Comparisons of baseline demographics, clinical presentation, and long-term outcome among patients with early, late, and very late stent thrombosis of sirolimus-eluting stents: observations from the Registry of Stent Thrombosis for Review and Reevaluation (RESTART). Circulation. 2010;122:52–61.PubMedCrossRef Kimura T, Morimoto T, Kozuma K, Honda Y, Kume T, Aizawa T, et al. Comparisons of baseline demographics, clinical presentation, and long-term outcome among patients with early, late, and very late stent thrombosis of sirolimus-eluting stents: observations from the Registry of Stent Thrombosis for Review and Reevaluation (RESTART). Circulation. 2010;122:52–61.PubMedCrossRef
5.
go back to reference Finn AV, Joner M, Nakazawa G, Kolodgie F, Newell J, John MC, et al. Pathological correlates of late drug-eluting stent thrombosis strut coverage as a marker of endothelialization. Circulation. 2007;115:2435–41. Finn AV, Joner M, Nakazawa G, Kolodgie F, Newell J, John MC, et al. Pathological correlates of late drug-eluting stent thrombosis strut coverage as a marker of endothelialization. Circulation. 2007;115:2435–41.
6.
go back to reference Nakazawa G, Finn AV, Joner M, Ladich E, Kutys R, Mont EK, et al. Delayed arterial healing and increased late stent thrombosis at culprit sites after drug-eluting stent placement for acute myocardial infarction patients: an autopsy study. Circulation. 2008;118:1138–45.PubMedCrossRef Nakazawa G, Finn AV, Joner M, Ladich E, Kutys R, Mont EK, et al. Delayed arterial healing and increased late stent thrombosis at culprit sites after drug-eluting stent placement for acute myocardial infarction patients: an autopsy study. Circulation. 2008;118:1138–45.PubMedCrossRef
7.
go back to reference Ikenaga H, Ishihara M, Dai K, Nakama Y, Ohtani T. Mechanisms of very late stent thrombosis after drug-eluting stent implantation: findings from coronary angioscopy and optical coherence tomography. JACC Cardiovasc Imaging. 2011;4:1217–9.PubMedCrossRef Ikenaga H, Ishihara M, Dai K, Nakama Y, Ohtani T. Mechanisms of very late stent thrombosis after drug-eluting stent implantation: findings from coronary angioscopy and optical coherence tomography. JACC Cardiovasc Imaging. 2011;4:1217–9.PubMedCrossRef
8.
go back to reference Guagliumi G, Farb A, Musumeci G, Valsecchi O, Tespili M, Motta T, et al. Sirolimus-eluting stent implanted in human coronary artery for 16 months: pathological findings. Circulation. 2003;107:1340–1.PubMedCrossRef Guagliumi G, Farb A, Musumeci G, Valsecchi O, Tespili M, Motta T, et al. Sirolimus-eluting stent implanted in human coronary artery for 16 months: pathological findings. Circulation. 2003;107:1340–1.PubMedCrossRef
9.
go back to reference Cook S, Ladich E, Nakazawa G, Eshtehardi P, Neidhart M, Vogel R, et al. Correlation of intravascular ultrasound findings with histopathological analysis of thrombus aspirates in patients with very late drug-eluting stent thrombosis. Circulation. 2009;120:391–9.PubMedCrossRef Cook S, Ladich E, Nakazawa G, Eshtehardi P, Neidhart M, Vogel R, et al. Correlation of intravascular ultrasound findings with histopathological analysis of thrombus aspirates in patients with very late drug-eluting stent thrombosis. Circulation. 2009;120:391–9.PubMedCrossRef
10.
go back to reference Nakazawa G, Otsuka F, Nakano M, Vorpahl M, Yazdani SK, Ladich E, et al. The pathology of neoatherosclerosis in human coronary implants bare-metal and drug-eluting stents. J Am Coll Cardiol. 2011;57:1314–22.PubMedCentralPubMedCrossRef Nakazawa G, Otsuka F, Nakano M, Vorpahl M, Yazdani SK, Ladich E, et al. The pathology of neoatherosclerosis in human coronary implants bare-metal and drug-eluting stents. J Am Coll Cardiol. 2011;57:1314–22.PubMedCentralPubMedCrossRef
11.
go back to reference Kotani J, Awata M, Nanto S, Uematsu M, Oshima F, Minamiguchi H, Mintz GS, et al. Incomplete neointimal coverage of sirolimus-eluting stents: angioscopic findings. J Am Coll Cardiol. 2006;162108–11.CrossRef Kotani J, Awata M, Nanto S, Uematsu M, Oshima F, Minamiguchi H, Mintz GS, et al. Incomplete neointimal coverage of sirolimus-eluting stents: angioscopic findings. J Am Coll Cardiol. 2006;162108–11.CrossRef
12.
go back to reference Takano M, Yamamoto M, Murakami D, Inami S, Okamatsu K, Seimiya K, et al. Lack of association between large angiographic late loss and low risk of in-stent thrombus: angioscopic comparison between paclitaxel- and sirolimus-eluting stents. Circ Cardiovasc Interv. 2008;1:20–7.PubMedCrossRef Takano M, Yamamoto M, Murakami D, Inami S, Okamatsu K, Seimiya K, et al. Lack of association between large angiographic late loss and low risk of in-stent thrombus: angioscopic comparison between paclitaxel- and sirolimus-eluting stents. Circ Cardiovasc Interv. 2008;1:20–7.PubMedCrossRef
13.
go back to reference Higo T, Ueda Y, Oyabu J, Okada K, Nishio M, Hirata A, et al. Atherosclerotic and thrombogenic neointima formed over sirolimus drug-eluting stent: an angioscopic study. JACC Cardiovasc Imaging. 2009;2:616–24.PubMedCrossRef Higo T, Ueda Y, Oyabu J, Okada K, Nishio M, Hirata A, et al. Atherosclerotic and thrombogenic neointima formed over sirolimus drug-eluting stent: an angioscopic study. JACC Cardiovasc Imaging. 2009;2:616–24.PubMedCrossRef
14.
go back to reference Oikawa Y, Yajima J, Costa MA, Matsuno S, Akabane M, Funada R, et al. Intravascular ultrasound, angioscopic and histopathological characterisation of heterogeneous patterns of restenosis after sirolimus-eluting stent implantation: insights into potential ‘‘thromborestenosis’’ phenomenon. EuroIntervention. 2010;6:380–7.PubMedCrossRef Oikawa Y, Yajima J, Costa MA, Matsuno S, Akabane M, Funada R, et al. Intravascular ultrasound, angioscopic and histopathological characterisation of heterogeneous patterns of restenosis after sirolimus-eluting stent implantation: insights into potential ‘‘thromborestenosis’’ phenomenon. EuroIntervention. 2010;6:380–7.PubMedCrossRef
15.
go back to reference den Heijer P, Foley DP, Hillege HL, Lablanche JM, van Dijk RB, Franzen D, et al. The “Ermenonville” classification of observations at coronary angioscopy: evaluation of intra- and inter-observer agreement. Eur Heart J. 1994;15:815–22. den Heijer P, Foley DP, Hillege HL, Lablanche JM, van Dijk RB, Franzen D, et al. The “Ermenonville” classification of observations at coronary angioscopy: evaluation of intra- and inter-observer agreement. Eur Heart J. 1994;15:815–22.
16.
go back to reference Tearney GJ, Regar E, Akasaka T, Adriaenssens T, Barlis P, Bezerra HG, et al. Consensus standards for acquisition, measurement, and reporting of intravascular optical coherence tomography studies. A report from the international working group for intravascular optical coherence tomography standardization and varidation. J Am Coll Cardiol. 2012;59:1058–72.PubMedCrossRef Tearney GJ, Regar E, Akasaka T, Adriaenssens T, Barlis P, Bezerra HG, et al. Consensus standards for acquisition, measurement, and reporting of intravascular optical coherence tomography studies. A report from the international working group for intravascular optical coherence tomography standardization and varidation. J Am Coll Cardiol. 2012;59:1058–72.PubMedCrossRef
17.
go back to reference Cutlip DE, Windecker S, Mehran R, Boam A, Cohen DJ, van Es GA, et al. Clinical end points in coronary stent trials: a case for standardized definitions. Circulation. 2007;115:2344–51.PubMedCrossRef Cutlip DE, Windecker S, Mehran R, Boam A, Cohen DJ, van Es GA, et al. Clinical end points in coronary stent trials: a case for standardized definitions. Circulation. 2007;115:2344–51.PubMedCrossRef
18.
go back to reference Kang S-J, Mintz GS, Akasaka T, Park D-W, Lee JY, Kim W-J, et al. Optical coherence tomographic analysis of in-stent neoatherosclerosis after drug-eluting stent implantation. Circulation. 2011;123:2954–63.PubMedCrossRef Kang S-J, Mintz GS, Akasaka T, Park D-W, Lee JY, Kim W-J, et al. Optical coherence tomographic analysis of in-stent neoatherosclerosis after drug-eluting stent implantation. Circulation. 2011;123:2954–63.PubMedCrossRef
19.
go back to reference Kashiwagi M, Tanaka A, Kitabata H, Ino Y, Tsujioka H, Komukai K, et al. OCT-verified neointimal hyperplasia is increased at fracture site in drug-eluting stents. JACC Cardiovasc Imaging. 2012;5:230–6.CrossRef Kashiwagi M, Tanaka A, Kitabata H, Ino Y, Tsujioka H, Komukai K, et al. OCT-verified neointimal hyperplasia is increased at fracture site in drug-eluting stents. JACC Cardiovasc Imaging. 2012;5:230–6.CrossRef
20.
go back to reference Otake H, Shite J, Shinke T. Evaluation of the peri-strut low intensity area following sirolimus- and paclitaxel-eluting stents implantation: insights from an optical coherence tomography study in humans. Int J Cardiol. 2012;157:38–42.PubMedCrossRef Otake H, Shite J, Shinke T. Evaluation of the peri-strut low intensity area following sirolimus- and paclitaxel-eluting stents implantation: insights from an optical coherence tomography study in humans. Int J Cardiol. 2012;157:38–42.PubMedCrossRef
21.
go back to reference Chen MS, John JM, Chew DP, Lee DS, Ellis SG, Bhatt DL. Bare metal stent restenosis is not a benign clinical entity. Am Heart J. 2006;151:1260–4.PubMedCrossRef Chen MS, John JM, Chew DP, Lee DS, Ellis SG, Bhatt DL. Bare metal stent restenosis is not a benign clinical entity. Am Heart J. 2006;151:1260–4.PubMedCrossRef
22.
go back to reference Hayashi T, Kotani J, Ishibashi-Ueda H, Yasuda S. Thrombus-related focal in-stent restenosis after everolimus-eluting stent implantation. Heart Vessels. 2014;29:273–7.PubMedCrossRef Hayashi T, Kotani J, Ishibashi-Ueda H, Yasuda S. Thrombus-related focal in-stent restenosis after everolimus-eluting stent implantation. Heart Vessels. 2014;29:273–7.PubMedCrossRef
23.
go back to reference Farb A, Burke AP, Tang AL, Liang TY, Mannan P, Smialek J, et al. Coronary plaque erosion without rupture into a lipid core. A frequent cause of coronary thrombosis in sudden coronary death. Circulation. 1996;93:1354–63.PubMedCrossRef Farb A, Burke AP, Tang AL, Liang TY, Mannan P, Smialek J, et al. Coronary plaque erosion without rupture into a lipid core. A frequent cause of coronary thrombosis in sudden coronary death. Circulation. 1996;93:1354–63.PubMedCrossRef
24.
go back to reference Kubo T, Imanishi T, Takarada S, Kuroi A, Ueno S, Yamano T, et al. Assessment of culprit lesion morphology in acute myocardial infarction: ability of optical coherence tomography compared with intravascular ultrasound and coronary angioscopy. J Am Coll Cardiol. 2007;50:933–9.PubMedCrossRef Kubo T, Imanishi T, Takarada S, Kuroi A, Ueno S, Yamano T, et al. Assessment of culprit lesion morphology in acute myocardial infarction: ability of optical coherence tomography compared with intravascular ultrasound and coronary angioscopy. J Am Coll Cardiol. 2007;50:933–9.PubMedCrossRef
25.
go back to reference Falk E, Nakano M, Bentzon JF, Finn AV, Virmani R. Update on acute coronary syndromes: the pathologists’ view. Eur Heart J. 2013;34:719–28.PubMedCrossRef Falk E, Nakano M, Bentzon JF, Finn AV, Virmani R. Update on acute coronary syndromes: the pathologists’ view. Eur Heart J. 2013;34:719–28.PubMedCrossRef
26.
go back to reference Mitsutake Y, Ueno T, Yokoyama S, Sasaki K, Sugi Y, Toyama Y, et al. Coronary endothelial dysfunction distal to stent of first-generation drug-eluting stents. JACC Cardiovasc Interv. 2012;5:966–73.PubMedCrossRef Mitsutake Y, Ueno T, Yokoyama S, Sasaki K, Sugi Y, Toyama Y, et al. Coronary endothelial dysfunction distal to stent of first-generation drug-eluting stents. JACC Cardiovasc Interv. 2012;5:966–73.PubMedCrossRef
27.
go back to reference Chen SL, Xu T, Zhang JJ, Ye F, Hu ZY, Tian NL, et al. Angioscopy study from a large patient population comparing sirolimus-eluting stent with biodegradable versus durable polymer. Catheter Cardiovasc Interv. 2012;80:420–8.PubMedCrossRef Chen SL, Xu T, Zhang JJ, Ye F, Hu ZY, Tian NL, et al. Angioscopy study from a large patient population comparing sirolimus-eluting stent with biodegradable versus durable polymer. Catheter Cardiovasc Interv. 2012;80:420–8.PubMedCrossRef
28.
go back to reference Prati F, Uemura S, Souteyrand G, Virmani R, Motreff P, Di Vito L, et al. OCT-based diagnosis and management of STEMI associated with intact fibrous cap. JACC Cardiovasc Imaging. 2013;6:283–7.PubMedCrossRef Prati F, Uemura S, Souteyrand G, Virmani R, Motreff P, Di Vito L, et al. OCT-based diagnosis and management of STEMI associated with intact fibrous cap. JACC Cardiovasc Imaging. 2013;6:283–7.PubMedCrossRef
29.
go back to reference Sakai S, Mizuno K, Yokoyama S, Tanabe J, Shinada T, Seimiya K, et al. Morphologic changes in infarct-related plaque after coronary stent placement: a serial angioscopy study. J Am Coll Cardiol. 2003;42:1558–65.PubMedCrossRef Sakai S, Mizuno K, Yokoyama S, Tanabe J, Shinada T, Seimiya K, et al. Morphologic changes in infarct-related plaque after coronary stent placement: a serial angioscopy study. J Am Coll Cardiol. 2003;42:1558–65.PubMedCrossRef
Metadata
Title
Angioscopic findings before and after thrombus-related drug-eluting stent failure
Authors
Jun-ichi Kotani
Shinsuke Nanto
Yasunori Ueda
Masaaki Uematsu
Masami Nishino
Shunichi Miyazaki
Yoshinori Yasaka
Satoshi Yasuda
Kyoichi Mizuno
Publication date
01-07-2015
Publisher
Springer Japan
Published in
Cardiovascular Intervention and Therapeutics / Issue 3/2015
Print ISSN: 1868-4300
Electronic ISSN: 1868-4297
DOI
https://doi.org/10.1007/s12928-014-0301-5

Other articles of this Issue 3/2015

Cardiovascular Intervention and Therapeutics 3/2015 Go to the issue