Abstract

Background and Purpose

The GestSure system is an Food and Drugs Administration (FDA)-registered depth-sensing infrared device initially developed for touchless image navigation during open surgery. The goal of this study was to explore the feasibility of this technology with medical students, residents, fellows and staff neurointerventionalists, using cases of intracranial aneurysm coiling.

Material and Methods

This was a prospective cohort study of operative performance using standard keyboard and mouse against a gestural interface. A total of four medical students, six residents, six fellows and five staff neurointerventionalists were involved in the training and subsequent testing. Training involved description and demonstration of a set of gestures optimized for 3D software functions. Cases were selected from the set of patients who underwent endovascular aneurysm coiling at the Toronto Western Hospital.

Results and Conclusion

For the overall group 15/21 (71.4%) individuals learned the left anterior oblique 30 degrees (LAO30) task within 20 cases, 17/21 (80.9%) learned the aneurysm neck task within 20 cases, 16/21 (76.2%) learned the parent vessel task and 14/21 (66%) learned the neck and parent vessel (anatomical) tasks. Staff were more consistent (i.e. smallest standard deviation) amongst the groups compared to medical students and residents; however, it was noted that a significant learning effect was observed in participants across every level of medical and angiographic expertise. Touchless angiography suite control with a gestural interface is feasible for the manipulation of angiographic images for neuroendovascular procedures. Learning to use the system was rapid across any level of medical training but greatest for staff neurointerventionalists.
Appendix
Available only for authorised users
Literature
1.
go back to reference Roe DB, Wang Y. A voice-controlled network for universal control of devices in the OR. Minim Invasive Ther Allied Technol. 2000;9:185–91.CrossRef Roe DB, Wang Y. A voice-controlled network for universal control of devices in the OR. Minim Invasive Ther Allied Technol. 2000;9:185–91.CrossRef
2.
go back to reference Strickland M, Tremaine J, Brigley G, Law C. Using a depth-sensing infrared camera system to access and manipulate medical imaging from within the sterile operating field. Can J Surg. 2013;56:E1–6.CrossRef Strickland M, Tremaine J, Brigley G, Law C. Using a depth-sensing infrared camera system to access and manipulate medical imaging from within the sterile operating field. Can J Surg. 2013;56:E1–6.CrossRef
3.
go back to reference Mewes A, Hensen B, Wacker F, Hansen C. Touchless interaction with software in interventional radiology and surgery: a systematic literature review. Int J Comput Assist Radiol Surg. 2017;12:291-305.CrossRef Mewes A, Hensen B, Wacker F, Hansen C. Touchless interaction with software in interventional radiology and surgery: a systematic literature review. Int J Comput Assist Radiol Surg. 2017;12:291-305.CrossRef
4.
go back to reference Hall MJ, Schwartzman A, Zhang J, Liu X. Ambulatory Surgery Data From Hospitals and Ambulatory Surgery Centers: United States, 2010. Natl Health Stat Report. 2017;102:1–15. Hall MJ, Schwartzman A, Zhang J, Liu X. Ambulatory Surgery Data From Hospitals and Ambulatory Surgery Centers: United States, 2010. Natl Health Stat Report. 2017;102:1–15.
5.
go back to reference Macario A. What does one minute of operating room time cost? J Clin Anesth. 2010;22:233–6.CrossRef Macario A. What does one minute of operating room time cost? J Clin Anesth. 2010;22:233–6.CrossRef
6.
go back to reference Shippert RD. A study of time-dependent operating room fees and how to save $100 000 by using time-saving products. Am J Cosmet Surg. 2005;22:25–34.CrossRef Shippert RD. A study of time-dependent operating room fees and how to save $100 000 by using time-saving products. Am J Cosmet Surg. 2005;22:25–34.CrossRef
7.
go back to reference Albergotti WG, Gooding WE, Kubik MW, Geltzeiler M, Kim S, Duvvuri U, Ferris RL. Assessment of surgical learning curves in transoral robotic surgery for squamous cell carcinoma of the oropharynx. JAMA Otolaryngol Head Neck Surg. 2017;143:542-8.CrossRefPubMedPubMedCentral Albergotti WG, Gooding WE, Kubik MW, Geltzeiler M, Kim S, Duvvuri U, Ferris RL. Assessment of surgical learning curves in transoral robotic surgery for squamous cell carcinoma of the oropharynx. JAMA Otolaryngol Head Neck Surg. 2017;143:542-8.CrossRefPubMedPubMedCentral
8.
go back to reference Grätzel C, Fong T, Grange S, Baur C. A non-contact mouse for surgeon-computer interaction. Technol Health Care. 2004;12:245–57.CrossRef Grätzel C, Fong T, Grange S, Baur C. A non-contact mouse for surgeon-computer interaction. Technol Health Care. 2004;12:245–57.CrossRef
9.
go back to reference Wipfli R, Dubois-Ferrière V, Budry S, Hoffmeyer P, Lovis C. Gesture-controlled image management for operating room: a randomized crossover study to compare interaction using gestures, mouse, and third person relaying. PLoS One. 2016;11:e0153596.CrossRef Wipfli R, Dubois-Ferrière V, Budry S, Hoffmeyer P, Lovis C. Gesture-controlled image management for operating room: a randomized crossover study to compare interaction using gestures, mouse, and third person relaying. PLoS One. 2016;11:e0153596.CrossRef
10.
go back to reference Yoshimitsu K, Muragaki Y, Maruyama T, Yamato M, Iseki H. Development and initial clinical testing of “OPECT”: an innovative device for fully intangible control of the intraoperative image-displaying monitor by the surgeon. Neurosurgery. 2014;10 Suppl 1:46–50; discussion 50.PubMed Yoshimitsu K, Muragaki Y, Maruyama T, Yamato M, Iseki H. Development and initial clinical testing of “OPECT”: an innovative device for fully intangible control of the intraoperative image-displaying monitor by the surgeon. Neurosurgery. 2014;10 Suppl 1:46–50; discussion 50.PubMed
11.
go back to reference Salama IA, Schwaitzberg SD. Utility of a voice-activated system in minimally invasive surgery. J Laparoendosc Adv Surg Tech A. 2005;15:443–6.CrossRef Salama IA, Schwaitzberg SD. Utility of a voice-activated system in minimally invasive surgery. J Laparoendosc Adv Surg Tech A. 2005;15:443–6.CrossRef
12.
go back to reference Wipfli R et al (2016) Gesture-Controlled Image Management for Operating Room: A Randomized Crossover Study to Compare Interaction Using Gestures, Mouse, and Third Person Relaying. PLoS ONE 11(4):e0153596.CrossRef Wipfli R et al (2016) Gesture-Controlled Image Management for Operating Room: A Randomized Crossover Study to Compare Interaction Using Gestures, Mouse, and Third Person Relaying. PLoS ONE 11(4):e0153596.CrossRef
Metadata
Title
Evaluation of a Touchless Angiography Suite Computer Controller for Neuroendovascular Procedures
Authors
Adam A. Dmytriw
Kevin Phan
Jamie Tremaine
Matt Strickland
Ivan Radovanovic
Timo Krings
Vitor M. Pereira
Publication date
01-03-2021
Publisher
Springer Berlin Heidelberg
Published in
Clinical Neuroradiology / Issue 1/2021
Print ISSN: 1869-1439
Electronic ISSN: 1869-1447
DOI
https://doi.org/10.1007/s00062-019-00829-6

Other articles of this Issue 1/2021

Clinical Neuroradiology 1/2021 Go to the issue