Skip to main content
Top
Published in: Neuroradiology 5/2012

01-05-2012 | Interventional Neuroradiology

Angiographically confirmed stent over expansion in the internal carotid artery during stenting: incidence, predictors, and outcomes

Authors: Masanori Tsutsumi, Hiroshi Aikawa, Kouhei Nii, Housei Etou, Kimiya Sakamoto, Hidenori Yoshida, Yoshihisa Matsumoto, Shuko Hamaguchi, Kiyoshi Kazekawa

Published in: Neuroradiology | Issue 5/2012

Login to get access

Abstract

Introduction

Selection of the appropriate diameter of stent is difficult in patients with the size mismatch between the internal carotid artery (ICA) and the common carotid artery (CCA). Although stent overexpansion (SOE) in the ICA after carotid artery stenting (CAS) is suspected of producing restenosis, SOE has not been well established. We discuss its incidence, predictors, and outcomes.

Methods

We retrospectively reviewed follow-up angiographs of 206 CAS-treated arteries in 201 patients who had undergone CAS. SOE was defined as angiographic evidence of an intimal gap between the non-stented normal and the dilated stented ICA at the distal stent edge. We also collected data on the patients’ clinical status, comorbidities, and radiological and procedural data. Patients with SOE were further followed up closely by duplex ultrasound scans.

Results

SOE was detected in nine of 206 CAS-treated ICAs (4.4%). Univariate analysis revealed a significant association between SOE and open-cell stents, the stent diameter (p < 0.01), pre-procedural stenosis, the ICA diameter, ICA/CCA ratio, and the ICA/stent ratio (p < 0.05). Entering these variables into a logistic regression model, open-cell stents were the only variable that significantly increased the risk for SOE (OR 2.36; 95% CI 0.99–4.60; p < 0.05). During a mean clinical follow-up of 31.1 months (range 24–39 months), none of the patients with SOE developed new neurologic ischemic symptoms, stent-edge stenosis, or in-stent restenosis.

Conclusion

SOE after CAS was not associated with clinical adverse effects. This study suggests that the diameter of stent should be determined by reference to the CCA diameter without respect to the ICA diameter.
Literature
1.
go back to reference Zhao HQ, Nikanorov A, Virmani R et al (2009) Late stent expansion and neointimal proliferation of oversized Nitinol stents in peripheral arteries. Cardiovasc Intervent Radiol 32:720–726PubMedCrossRef Zhao HQ, Nikanorov A, Virmani R et al (2009) Late stent expansion and neointimal proliferation of oversized Nitinol stents in peripheral arteries. Cardiovasc Intervent Radiol 32:720–726PubMedCrossRef
2.
go back to reference Roubin GS, Iyer S, Halkin A et al (2006) Realizing the potential of carotid artery stenting: proposed paradigms for patient selection and procedural technique. Circulation 113:2021–2030PubMedCrossRef Roubin GS, Iyer S, Halkin A et al (2006) Realizing the potential of carotid artery stenting: proposed paradigms for patient selection and procedural technique. Circulation 113:2021–2030PubMedCrossRef
3.
go back to reference Brown KE, Usman A, Kibbe MR et al (2009) Carotid stenting using tapered and nontapered stents: associated neurological complications and restenosis rates. Ann Vasc Surg 23:439–445PubMedCrossRef Brown KE, Usman A, Kibbe MR et al (2009) Carotid stenting using tapered and nontapered stents: associated neurological complications and restenosis rates. Ann Vasc Surg 23:439–445PubMedCrossRef
4.
go back to reference Clark DJ, Lessio S, O’Donoghue M et al (2006) Mechanisms and predictors of carotid artery stent restenosis: a serial intravascular ultrasound study. J Am Coll Cardiol 47:2390–2396PubMedCrossRef Clark DJ, Lessio S, O’Donoghue M et al (2006) Mechanisms and predictors of carotid artery stent restenosis: a serial intravascular ultrasound study. J Am Coll Cardiol 47:2390–2396PubMedCrossRef
5.
go back to reference Piamsomboon C, Roubin GS, Liu MW et al (1998) Relationship between oversizing of self-expanding stents and late loss index in carotid stenting. Cathet Cardiovasc Diagn 45:139–143PubMedCrossRef Piamsomboon C, Roubin GS, Liu MW et al (1998) Relationship between oversizing of self-expanding stents and late loss index in carotid stenting. Cathet Cardiovasc Diagn 45:139–143PubMedCrossRef
6.
go back to reference Roguin A, Grenadier E, Linn S et al (1999) Continued expansion of the nitinol self-expanding coronary stent: angiographic analysis and 1-year clinical follow-up. Am Heart J 138:326–333PubMedCrossRef Roguin A, Grenadier E, Linn S et al (1999) Continued expansion of the nitinol self-expanding coronary stent: angiographic analysis and 1-year clinical follow-up. Am Heart J 138:326–333PubMedCrossRef
7.
go back to reference Willfort-Ehringer A, Ahmadi R, Gruber D et al (2004) Arterial remodeling and hemodynamics in carotid stents: a prospective duplex ultrasound study over 2 years. J Vasc Surg 39:728–734PubMedCrossRef Willfort-Ehringer A, Ahmadi R, Gruber D et al (2004) Arterial remodeling and hemodynamics in carotid stents: a prospective duplex ultrasound study over 2 years. J Vasc Surg 39:728–734PubMedCrossRef
8.
go back to reference Wang TJ, Nam BH, Wilson PW et al (2002) Association of C-reactive protein with carotid atherosclerosis in men and women: the Framingham heart study. Arterioscler Thromb Vasc Biol 22:1662–1667PubMedCrossRef Wang TJ, Nam BH, Wilson PW et al (2002) Association of C-reactive protein with carotid atherosclerosis in men and women: the Framingham heart study. Arterioscler Thromb Vasc Biol 22:1662–1667PubMedCrossRef
9.
go back to reference North American Symptomatic Carotid Endarterectomy Trial Collaborators (1991) Beneficial effect of carotid endarterectomy in symptomatic patients with high-grade carotid stenosis. N Engl J Med 325:445–453CrossRef North American Symptomatic Carotid Endarterectomy Trial Collaborators (1991) Beneficial effect of carotid endarterectomy in symptomatic patients with high-grade carotid stenosis. N Engl J Med 325:445–453CrossRef
10.
go back to reference Tanaka N, Martin JB, Tokunaga K et al (2004) Conformity of carotid stents with vascular anatomy: evaluation in carotid models. AJNR Am J Neuroradiol 25:604–607PubMed Tanaka N, Martin JB, Tokunaga K et al (2004) Conformity of carotid stents with vascular anatomy: evaluation in carotid models. AJNR Am J Neuroradiol 25:604–607PubMed
11.
go back to reference Bosiers M, Deloose K, Verbist J et al (2005) Carotid artery stenting: which stent for which lesion? Vascular 13:205–210PubMed Bosiers M, Deloose K, Verbist J et al (2005) Carotid artery stenting: which stent for which lesion? Vascular 13:205–210PubMed
12.
go back to reference Maynar M, Baldi S, Rostagno R et al (2007) Carotid stenting without use of balloon angioplasty and distal protection devices: preliminary experience in 100 cases. AJNR Am J Neuroradiol 28:1378–1383PubMedCrossRef Maynar M, Baldi S, Rostagno R et al (2007) Carotid stenting without use of balloon angioplasty and distal protection devices: preliminary experience in 100 cases. AJNR Am J Neuroradiol 28:1378–1383PubMedCrossRef
13.
go back to reference Bussière M, Pelz DM, Kalapos P, Lee D, Gulka I, Leung A, Lownie SP (2008) Results using a self-expanding stent alone in the treatment of severe symptomatic carotid bifurcation stenosis. J Neurosurg 109:454–460PubMedCrossRef Bussière M, Pelz DM, Kalapos P, Lee D, Gulka I, Leung A, Lownie SP (2008) Results using a self-expanding stent alone in the treatment of severe symptomatic carotid bifurcation stenosis. J Neurosurg 109:454–460PubMedCrossRef
14.
go back to reference Kishikawa K, Kamouchi M, Okada Y et al (2002) Evaluation of distal extracranial internal carotid artery by transoral carotid ultrasonography in patients with severe carotid stenosis. AJNR Am J Neuroradiol 23:924–928PubMed Kishikawa K, Kamouchi M, Okada Y et al (2002) Evaluation of distal extracranial internal carotid artery by transoral carotid ultrasonography in patients with severe carotid stenosis. AJNR Am J Neuroradiol 23:924–928PubMed
15.
go back to reference Santana DB, Armentano RL, Zócalo Y et al (2007) Functional properties of fresh and cryopreserved carotid and femoral arteries, and of venous and synthetic grafts: comparison with arteries from normotensive and hypertensive patients. Cell Tissue Bank 8:43–857PubMedCrossRef Santana DB, Armentano RL, Zócalo Y et al (2007) Functional properties of fresh and cryopreserved carotid and femoral arteries, and of venous and synthetic grafts: comparison with arteries from normotensive and hypertensive patients. Cell Tissue Bank 8:43–857PubMedCrossRef
16.
go back to reference Timmins LH, Meyer CA, Moreno MR et al (2008) Mechanical modeling of stents deployed in tapered arteries. Ann Biomed Eng 36:2042–2050PubMedCrossRef Timmins LH, Meyer CA, Moreno MR et al (2008) Mechanical modeling of stents deployed in tapered arteries. Ann Biomed Eng 36:2042–2050PubMedCrossRef
17.
go back to reference Berry JL, Manoach E, Mekkaoui C et al (2002) Hemodynamics and wall mechanics of a compliance matching stent: in vitro and in vivo analysis. J Vasc Interv Radiol 13:97–105PubMedCrossRef Berry JL, Manoach E, Mekkaoui C et al (2002) Hemodynamics and wall mechanics of a compliance matching stent: in vitro and in vivo analysis. J Vasc Interv Radiol 13:97–105PubMedCrossRef
18.
go back to reference Sarembock IJ, LaVeau PJ, Sigal SL et al (1989) Influence of inflation pressure and balloon size on the development of intimal hyperplasia after balloon angioplasty. A study in the atherosclerotic rabbit. Circulation 80:1029–1040PubMedCrossRef Sarembock IJ, LaVeau PJ, Sigal SL et al (1989) Influence of inflation pressure and balloon size on the development of intimal hyperplasia after balloon angioplasty. A study in the atherosclerotic rabbit. Circulation 80:1029–1040PubMedCrossRef
19.
go back to reference Grenadier E, Shofti R, Beyar M et al (1994) Self-expandable and highly flexible nitinol stent: immediate and long-term results in dogs. Am Heart J 128:870–878PubMedCrossRef Grenadier E, Shofti R, Beyar M et al (1994) Self-expandable and highly flexible nitinol stent: immediate and long-term results in dogs. Am Heart J 128:870–878PubMedCrossRef
20.
go back to reference Schürmann K, Vorwerk D, Kulisch A et al (1996) Neointimal hyperplasia in low-profile Nitinol stents, Palmaz stents, and Wallstents: a comparative experimental study. Cardiovasc Intervent Radiol 19:248–254PubMedCrossRef Schürmann K, Vorwerk D, Kulisch A et al (1996) Neointimal hyperplasia in low-profile Nitinol stents, Palmaz stents, and Wallstents: a comparative experimental study. Cardiovasc Intervent Radiol 19:248–254PubMedCrossRef
Metadata
Title
Angiographically confirmed stent over expansion in the internal carotid artery during stenting: incidence, predictors, and outcomes
Authors
Masanori Tsutsumi
Hiroshi Aikawa
Kouhei Nii
Housei Etou
Kimiya Sakamoto
Hidenori Yoshida
Yoshihisa Matsumoto
Shuko Hamaguchi
Kiyoshi Kazekawa
Publication date
01-05-2012
Publisher
Springer-Verlag
Published in
Neuroradiology / Issue 5/2012
Print ISSN: 0028-3940
Electronic ISSN: 1432-1920
DOI
https://doi.org/10.1007/s00234-011-0902-y

Other articles of this Issue 5/2012

Neuroradiology 5/2012 Go to the issue