Skip to main content
Top
Published in: Neuroradiology 7/2020

01-07-2020 | Aneurysm | Interventional Neuroradiology

Simultaneous neck coverage and branch preservation using the proximal portion of a self-expandable open-cell stent for embolization of distal internal carotid artery aneurysms: multi-center, long-term results

Authors: Hyon-Jo Kwon, Seung-Hoon You, Jeong-Wook Lim, Hyoung Soo Byoun, Bon-Sub Gu, Su-Hee Cho, Hyeon-Song Koh

Published in: Neuroradiology | Issue 7/2020

Login to get access

Abstract

Purpose

We report the long-term results of a modified stent-assisted coil embolization technique using the far proximal part of a self-expanding open-cell stent. The technique was used to cover the neck of the aneurysm while simultaneously preserving the branches of the distal internal carotid artery in patients with aneurysms of the posterior communicating (Pcom) and anterior choroidal arteries (AchA).

Methods

We performed a retrospective review of the prospectively maintained databases at two tertiary neurosurgical centers to identify all patients who underwent embolization of Pcom or AchA aneurysms using this technique between January 2014 and July 2019. Postoperative and follow-up clinical and radiological results for initial (n = 16) or re-do (n = 4) embolizations were analyzed.

Results

We identified 19 patients with 20 (16 Pcom and 4 AchA) unruptured (n = 19) or ruptured (n = 1) aneurysms. Eighteen among 20 stents (90.0%) were deployed successfully, and complete occlusions were initially attained in 18 aneurysms (90.0%). At follow-up examinations 8 to 56 months later, 6 of 14 aneurysms (42.8%) showed neck remnants. All of the branches were saved and no thromboembolic event, rupture, or sequelae were noted during or after the procedures.

Conclusion

These results suggest that this modified stent-assisted technique is a feasible and reasonable alternative to conventional stent deployment for coil embolization of wide-necked sidewall aneurysms in the distal ICA.
Literature
1.
go back to reference Zhao B, Yin R, Lanzino G et al (2016) Endovascular coiling of wide-neck and wide-neck bifurcation aneurysms: a systematic review and meta-analysis. AJNR Am J Neuroradiol 9:1700–1705CrossRef Zhao B, Yin R, Lanzino G et al (2016) Endovascular coiling of wide-neck and wide-neck bifurcation aneurysms: a systematic review and meta-analysis. AJNR Am J Neuroradiol 9:1700–1705CrossRef
2.
go back to reference Wanke I, Forsting M (2008) Stents for intracranial widenecked aneurysms: more than mechanical protection. Neuroradiology 50:991–998CrossRef Wanke I, Forsting M (2008) Stents for intracranial widenecked aneurysms: more than mechanical protection. Neuroradiology 50:991–998CrossRef
3.
go back to reference Akpek S, Arat A, Morsi H et al (2005) Self-expandable stent-assisted coiling of wide-necked intracranial aneurysms: a single-center experience. AJNR Am J Neuroradiol 5:1223–1231 Akpek S, Arat A, Morsi H et al (2005) Self-expandable stent-assisted coiling of wide-necked intracranial aneurysms: a single-center experience. AJNR Am J Neuroradiol 5:1223–1231
4.
go back to reference Roy D, Milot G, Raymond J (2001) Endovascular treatment of unruptured aneurysms. Stroke 9:1998–2004CrossRef Roy D, Milot G, Raymond J (2001) Endovascular treatment of unruptured aneurysms. Stroke 9:1998–2004CrossRef
5.
go back to reference Chow MM, Woo HH, Masaryk TJ, Rasmussen PA (2004) A novel endovascular treatment of a wide-necked basilar apex aneurysm by using a Y-configuration, double-stent technique. AJNR Am J Neuroradiol 25:509–512PubMed Chow MM, Woo HH, Masaryk TJ, Rasmussen PA (2004) A novel endovascular treatment of a wide-necked basilar apex aneurysm by using a Y-configuration, double-stent technique. AJNR Am J Neuroradiol 25:509–512PubMed
6.
go back to reference Cho YD, Park SW, Lee JY et al (2012) Nonoverlapping Y-configuration stenting technique with dual closed-cell stents in wide-neck basilar tip aneurysms. Neurosurgery 2(Suppl Operative):244–249 Cho YD, Park SW, Lee JY et al (2012) Nonoverlapping Y-configuration stenting technique with dual closed-cell stents in wide-neck basilar tip aneurysms. Neurosurgery 2(Suppl Operative):244–249
7.
go back to reference Benndorf G, Klucznik RP, Meyer D et al (2006) “Cross-over” technique for horizontal stenting of an internal carotid bifurcation aneurysm using a new self-expandable stent: technical case report. Neurosurgery 1(Suppl):ONS–E172 Benndorf G, Klucznik RP, Meyer D et al (2006) “Cross-over” technique for horizontal stenting of an internal carotid bifurcation aneurysm using a new self-expandable stent: technical case report. Neurosurgery 1(Suppl):ONS–E172
8.
go back to reference Cho YD, Kang HS, Kim JE et al (2014) Modified protection using far proximal portion of self-expandable closed-cell stents for embolization of wide-necked intracranial aneurysms. Neuroradiology 10:851–857CrossRef Cho YD, Kang HS, Kim JE et al (2014) Modified protection using far proximal portion of self-expandable closed-cell stents for embolization of wide-necked intracranial aneurysms. Neuroradiology 10:851–857CrossRef
9.
go back to reference Lubicz B (2011) Linear stent-assisted coiling: another way to treat very wide-necked intracranial aneurysms. Neuroradiology 6:457–459CrossRef Lubicz B (2011) Linear stent-assisted coiling: another way to treat very wide-necked intracranial aneurysms. Neuroradiology 6:457–459CrossRef
10.
go back to reference Kühn AL, Hou SY, Puri AS et al (2016) Stent-assisted coil embolization of aneurysms with small parent vessels: safety and efficacy analysis. J Neurointerv Surg 6:581–585CrossRef Kühn AL, Hou SY, Puri AS et al (2016) Stent-assisted coil embolization of aneurysms with small parent vessels: safety and efficacy analysis. J Neurointerv Surg 6:581–585CrossRef
11.
go back to reference Hong B, Patel NV, Gounis MJ et al (2009) Semi-jailing technique for coil embolization of complex, wide-necked intracranial aneurysms. Neurosurgery 6:1131–1138CrossRef Hong B, Patel NV, Gounis MJ et al (2009) Semi-jailing technique for coil embolization of complex, wide-necked intracranial aneurysms. Neurosurgery 6:1131–1138CrossRef
12.
go back to reference Mangubat EZ, Johnson AK, Keigher KM et al (2012) Initial experience with Neuroform EZ in the treatment of wide-neck cerebral aneurysms. Neurointervention 1:34–39CrossRef Mangubat EZ, Johnson AK, Keigher KM et al (2012) Initial experience with Neuroform EZ in the treatment of wide-neck cerebral aneurysms. Neurointervention 1:34–39CrossRef
13.
go back to reference Ulfert C, Pham M, Sonnberger M et al (2018) The Neuroform Atlas stent to assist coil embolization of intracranial aneurysms: a multicentre experience. J Neurointerv Surg 12:1192–1196CrossRef Ulfert C, Pham M, Sonnberger M et al (2018) The Neuroform Atlas stent to assist coil embolization of intracranial aneurysms: a multicentre experience. J Neurointerv Surg 12:1192–1196CrossRef
14.
go back to reference Cho SH, Jo WI, Jo YE et al (2017) Bench-top comparison of physical properties of 4 commercially-available self-expanding intracranial stents. Neurointervention 1:31–39CrossRef Cho SH, Jo WI, Jo YE et al (2017) Bench-top comparison of physical properties of 4 commercially-available self-expanding intracranial stents. Neurointervention 1:31–39CrossRef
15.
go back to reference Krischek O, Miloslavski E, Fischer S et al (2011) A comparison of functional and physical properties of self-expanding intracranial stents [Neuroform3, Wingspan, Solitaire, Leo+, Enterprise]. Minim Invasive Neurosurg 1:21–28CrossRef Krischek O, Miloslavski E, Fischer S et al (2011) A comparison of functional and physical properties of self-expanding intracranial stents [Neuroform3, Wingspan, Solitaire, Leo+, Enterprise]. Minim Invasive Neurosurg 1:21–28CrossRef
16.
go back to reference Kelly ME, Turner RD 4th, Moskowitz SI et al (2008) Delayed migration of a self-expanding intracranial microstent. AJNR Am J Neuroradiol 10:1959–1960CrossRef Kelly ME, Turner RD 4th, Moskowitz SI et al (2008) Delayed migration of a self-expanding intracranial microstent. AJNR Am J Neuroradiol 10:1959–1960CrossRef
17.
go back to reference Piotin M, Mounayer C, Spelle L et al (2004) Endovascular treatment of anterior choroidal artery aneurysms. AJNR Am J Neuroradiol 2:314–318 Piotin M, Mounayer C, Spelle L et al (2004) Endovascular treatment of anterior choroidal artery aneurysms. AJNR Am J Neuroradiol 2:314–318
18.
go back to reference Cho YD, Jung SC, Kim CH et al (2015) Posterior communicating artery compromise in coil embolization of posterior communicating artery aneurysms. Clin Neuroradiol 3:275–279CrossRef Cho YD, Jung SC, Kim CH et al (2015) Posterior communicating artery compromise in coil embolization of posterior communicating artery aneurysms. Clin Neuroradiol 3:275–279CrossRef
19.
go back to reference Endo H, Sato K, Kondo R et al (2012) Tuberothalamic artery infarctions following coil embolization of ruptured posterior communicating artery aneurysms with posterior communicating artery sacrifice. AJNR Am J Neuroradiol 3:500–506CrossRef Endo H, Sato K, Kondo R et al (2012) Tuberothalamic artery infarctions following coil embolization of ruptured posterior communicating artery aneurysms with posterior communicating artery sacrifice. AJNR Am J Neuroradiol 3:500–506CrossRef
20.
go back to reference Cho YD, Lee WJ, Kim KM et al (2013) Stent-assisted coil embolization of posterior communicating artery aneurysms. AJNR Am J Neuroradiol 11:2171–2176CrossRef Cho YD, Lee WJ, Kim KM et al (2013) Stent-assisted coil embolization of posterior communicating artery aneurysms. AJNR Am J Neuroradiol 11:2171–2176CrossRef
Metadata
Title
Simultaneous neck coverage and branch preservation using the proximal portion of a self-expandable open-cell stent for embolization of distal internal carotid artery aneurysms: multi-center, long-term results
Authors
Hyon-Jo Kwon
Seung-Hoon You
Jeong-Wook Lim
Hyoung Soo Byoun
Bon-Sub Gu
Su-Hee Cho
Hyeon-Song Koh
Publication date
01-07-2020
Publisher
Springer Berlin Heidelberg
Keywords
Aneurysm
Aneurysm
Published in
Neuroradiology / Issue 7/2020
Print ISSN: 0028-3940
Electronic ISSN: 1432-1920
DOI
https://doi.org/10.1007/s00234-020-02411-1

Other articles of this Issue 7/2020

Neuroradiology 7/2020 Go to the issue