Introduction

The purpose of this study was to measure the structures of the ventral of lateral masses using cadaver specimens and to quantitatively compare the safety zone for the two major techniques used on each vertebral level from C3 to C6.

Methods

This study is based on 52 cervical vertebrae of 13 cadavers. The anatomical measurements focused on the anterior surface of the lateral mass. We investigated the safety width, heights, and the height of nerve roots.

Results

The mean values of the safety width of the Magerl technique from C3 to C6 were 6.1, 7.3, 6.4 and 4.3 mm, respectively. The mean values of the safety width of the Roy-Camille technique were 6.7, 6.6, 5.8 and 5.4 mm, respectively. The mean values of the safety height of the Magerl technique were 5.0, 5.4, 5.8 and 5.2 mm, respectively. The mean values of the safety height of the Roy-Camille technique were 4.9, 4.0, 1.0 and −1.2 mm, respectively. The mean values of the nerve root height were 3.9, 4.9, 5.9 and 6.9 mm, respectively.

Conclusion

The safety width of the Magerl technique was shorter at C6 because the vertebral artery runs more laterally at C6. The height for the Magerl technique was not significantly different from C3 to C6, however, the safety height for the Roy-Camille technique was significantly shorter at C5 and C6. Our findings suggest that it is important to ensure that the screw(s) penetrate through the cranial side of the ventral aspect of a lateral mass when performing the Magerl technique at all vertebral levels, and to carefully select the screw length when using the Roy-Camille technique, especially at C5 and C6, in order to avoid nerve root injury.
Literature
1.
go back to reference An HS, Gordin R, Renner K (1991) Anatomic consideration for plate-screw fixation of the cervical spine. Spine 16(Suppl):S548–S551PubMedCrossRef An HS, Gordin R, Renner K (1991) Anatomic consideration for plate-screw fixation of the cervical spine. Spine 16(Suppl):S548–S551PubMedCrossRef
2.
go back to reference Anderson PA, Henley MB, Grady MS, Montesano PX, Winn HR (1991) Posterior cervical arthrodesis with AO reconstruction plate and bone graft. Spine 16(Suppl):S72–S79PubMedCrossRef Anderson PA, Henley MB, Grady MS, Montesano PX, Winn HR (1991) Posterior cervical arthrodesis with AO reconstruction plate and bone graft. Spine 16(Suppl):S72–S79PubMedCrossRef
3.
go back to reference Barrey C, Mertens P, Jund J et al (2005) Quantitative anatomic evaluation of cervical lateral mass fixation with a comparison of the Roy-Camille and the Magerl screw techniques. Spine 30:E140–E147PubMedCrossRef Barrey C, Mertens P, Jund J et al (2005) Quantitative anatomic evaluation of cervical lateral mass fixation with a comparison of the Roy-Camille and the Magerl screw techniques. Spine 30:E140–E147PubMedCrossRef
4.
go back to reference Cho KH, Shin YS, Yoon SH et al (2005) Poor surgical technique in cervical plating leading to vertebral artery injury and brain stem infarction—Case report. Surg Neurol 64:221–225PubMedCrossRef Cho KH, Shin YS, Yoon SH et al (2005) Poor surgical technique in cervical plating leading to vertebral artery injury and brain stem infarction—Case report. Surg Neurol 64:221–225PubMedCrossRef
5.
go back to reference Choueka J, Spivak JM, Kummer FJ, Steger T (1996) Fixation failure of posterior cervical lateral mass screws. Spine 21:462–468PubMedCrossRef Choueka J, Spivak JM, Kummer FJ, Steger T (1996) Fixation failure of posterior cervical lateral mass screws. Spine 21:462–468PubMedCrossRef
6.
go back to reference Deen HG, Nottmeier EW, Reimer R (2006) Early complications of posterior rod-screw fixation of the cervical and upper thoracic spine. Neurosurgery 59:1062–1067 (discussion 7–8) Deen HG, Nottmeier EW, Reimer R (2006) Early complications of posterior rod-screw fixation of the cervical and upper thoracic spine. Neurosurgery 59:1062–1067 (discussion 7–8)
7.
go back to reference Ebraheim NA, Xu R, Yeasting RA (1996) The location of the vertebral artery foramen and its relation to posterior lateral mass screw fixation. Spine 21:1291–1295PubMedCrossRef Ebraheim NA, Xu R, Yeasting RA (1996) The location of the vertebral artery foramen and its relation to posterior lateral mass screw fixation. Spine 21:1291–1295PubMedCrossRef
8.
go back to reference Ebraheim NA, Klausner T, Xu R et al (1998) Safe lateral mass screw lengths in the Roy-Camille and Magerl technique Anatomic study. Spine 23:1739–1742PubMedCrossRef Ebraheim NA, Klausner T, Xu R et al (1998) Safe lateral mass screw lengths in the Roy-Camille and Magerl technique Anatomic study. Spine 23:1739–1742PubMedCrossRef
9.
go back to reference Gill K, Paschal S, Corin J, Asham R, Bucholz R (1988) Posterior plating of the cervical spine: a biomechanical comparison of different posterior fusion techniques. Spine 13:813–816PubMedCrossRef Gill K, Paschal S, Corin J, Asham R, Bucholz R (1988) Posterior plating of the cervical spine: a biomechanical comparison of different posterior fusion techniques. Spine 13:813–816PubMedCrossRef
10.
go back to reference Graham AW, Swank ML, Kinard RE, Lowery GL, Dials BE (1996) Posterior cervical arthrodesis and stabilization with a lateral mass plate: clinical and computed tomography evaluation of lateral mass screw placement and associated complications. Spine 21:323–329PubMedCrossRef Graham AW, Swank ML, Kinard RE, Lowery GL, Dials BE (1996) Posterior cervical arthrodesis and stabilization with a lateral mass plate: clinical and computed tomography evaluation of lateral mass screw placement and associated complications. Spine 21:323–329PubMedCrossRef
11.
go back to reference Heller JG, Garlson GD, Abitbol J, Garfin SR (1991) Anatomic comparison of the Roy-Camille and Magerl techniques for screw placement. Spine 16(suppl):S552–S557PubMedCrossRef Heller JG, Garlson GD, Abitbol J, Garfin SR (1991) Anatomic comparison of the Roy-Camille and Magerl techniques for screw placement. Spine 16(suppl):S552–S557PubMedCrossRef
12.
go back to reference Jeanneret B, Magerl F, Ward EH, Ward J (1991) Posterior stabilization of the cervical spine with hook plates. Spine 16(suppl):S56–S63PubMedCrossRef Jeanneret B, Magerl F, Ward EH, Ward J (1991) Posterior stabilization of the cervical spine with hook plates. Spine 16(suppl):S56–S63PubMedCrossRef
13.
go back to reference Levine AM, Mazel C, Roy-Camille R (1992) Management fracture separations of the articular mass using posterior cervical plating. Spine 17:S447–S454PubMedCrossRef Levine AM, Mazel C, Roy-Camille R (1992) Management fracture separations of the articular mass using posterior cervical plating. Spine 17:S447–S454PubMedCrossRef
14.
go back to reference Muffoletto AJ, Yang J, Vadhva M et al (2003) Cervical stability with lateral mass plating: unicortical versus bicortical screw purchase. Spine 28:778–781PubMed Muffoletto AJ, Yang J, Vadhva M et al (2003) Cervical stability with lateral mass plating: unicortical versus bicortical screw purchase. Spine 28:778–781PubMed
15.
go back to reference Roy-Camille R, Saillant G, Lavile C, Mazel C (1989) Internal fixation of lower cervical spine by a posterior osteosynthesis with plates and screws. In: Cervical Spine Research Society (ed) The cervical spine, 2nd edn. JB Lippicott, Philadelphia, pp 390–430 Roy-Camille R, Saillant G, Lavile C, Mazel C (1989) Internal fixation of lower cervical spine by a posterior osteosynthesis with plates and screws. In: Cervical Spine Research Society (ed) The cervical spine, 2nd edn. JB Lippicott, Philadelphia, pp 390–430
16.
go back to reference Roy-Camille R, Saillant G, Berteaux D, Serge MA (1992) Treatment of lower cervical spinal injuries-C3 to C7. Spine 17(Suppl):S442–S446PubMedCrossRef Roy-Camille R, Saillant G, Berteaux D, Serge MA (1992) Treatment of lower cervical spinal injuries-C3 to C7. Spine 17(Suppl):S442–S446PubMedCrossRef
17.
go back to reference Sekhon LH (2005) Posterior cervical lateral mass screw fixation, analysis of 1026 consecutive screws in 143 patients. J Spinal Disord Tech 18:297–303PubMedCrossRef Sekhon LH (2005) Posterior cervical lateral mass screw fixation, analysis of 1026 consecutive screws in 143 patients. J Spinal Disord Tech 18:297–303PubMedCrossRef
18.
go back to reference Stemper BD, Marawar SV et al (2004) Quantitative anatomy of subaxial cervical lateral mass. An analysis of safe screw lengths for Roy-camille and Magerl techniques. J Spinal Disord Tech 17:102–107CrossRef Stemper BD, Marawar SV et al (2004) Quantitative anatomy of subaxial cervical lateral mass. An analysis of safe screw lengths for Roy-camille and Magerl techniques. J Spinal Disord Tech 17:102–107CrossRef
Metadata
Title
Anatomy of subaxial cervical foramens: the safety zone for lateral mass screwing
Authors
Masahiro Nishinome
Haku Iizuka
Yoichi Iizuka
Kenji Takagishi
Publication date
01-02-2012
Publisher
Springer-Verlag
Published in
European Spine Journal / Issue 2/2012
Print ISSN: 0940-6719
Electronic ISSN: 1432-0932
DOI
https://doi.org/10.1007/s00586-011-1984-2

Other articles of this Issue 2/2012

European Spine Journal 2/2012 Go to the issue