Abstract

Objective

To determine the presence of a consistent osseous corridor through S1 and S2 and fluoroscopic landmarks thereof, which could be used for safe trans ilio-sacroiliac screw fixation of posterior pelvic ring disorders.

Study design

Computed tomography (CT) based anatomical investigation utilising multiplanar image and trajectory reconstruction (Agfa-IMPAX Version 5.2 software). Determination of the presence and dimension of a continuous osseous corridor in the coronal plane of the sacrum at the S1 and S2 vertebral levels.

Outcome measures

Determination of: (a) the presence of an osseous corridor in the coronal plane through S1 and S2 in males and females; (b) the dimension of the corridor with regard to diameter and length; (c) the fluoroscopic landmarks of the corridor.

Results

The mean cross-sectional area for S1 corridors in males and females was 2.13 and 1.47 cm2 , respectively. The mean cross-sectional area for the S2 corridor in males and females was 1.46 and 1.13 cm2, respectively. The limiting anatomical factor is the sagittal diameter of the sacral ala at the junction to the vertebral body. The centre of the S1 and S2 corridor is located in close proximity to the centre of the S1 and S2 vertebrae on the lateral fluoroscopic view as determined by the adjacent endplates and anterior and posterior vertebral cortices.

Conclusion

Two-thirds of males and females have a complete osseous corridor to pass a trans-sacroiliac S1 screw of 8 mm diameter. The S2 corridor was present in all males but only in 87 % of females. Preoperative review of the axial CT slices at the midpoint of the S1 or S2 vertebral body allows the presence of a trans-sacroiliac osseous corridor to be determined by assessing the passage at the narrowest point of the corridor at the junction of the sacral ala to the vertebral body.
Literature
1.
go back to reference Roy-Camille R, Saillant G, Gagna G, Mazel C (1985) Transverse fracture of the upper sacrum. Suicidal jumper’s fracture. Spine (Phila Pa 1976) 10:838–845CrossRef Roy-Camille R, Saillant G, Gagna G, Mazel C (1985) Transverse fracture of the upper sacrum. Suicidal jumper’s fracture. Spine (Phila Pa 1976) 10:838–845CrossRef
3.
5.
go back to reference Schildhauer TA, Bellabarba C, Nork SE et al (2006) Decompression and lumbopelvic fixation for sacral fracture-dislocations with spino-pelvic dissociation. J Orthop Trauma 20:447–457CrossRefPubMed Schildhauer TA, Bellabarba C, Nork SE et al (2006) Decompression and lumbopelvic fixation for sacral fracture-dislocations with spino-pelvic dissociation. J Orthop Trauma 20:447–457CrossRefPubMed
7.
go back to reference Matta JM, Tornetta P (1996) Internal fixation of unstable pelvic ring injuries. Clin Orthop Relat Res 329:129–140CrossRefPubMed Matta JM, Tornetta P (1996) Internal fixation of unstable pelvic ring injuries. Clin Orthop Relat Res 329:129–140CrossRefPubMed
10.
go back to reference Routt M Jr (2006) Posterior pelvic-ring disruptions: iliosacral screws. In: Wiss D (ed) Fractures. Lippincott, Williams & Wilkins, Philadelphia, pp 649–667 Routt M Jr (2006) Posterior pelvic-ring disruptions: iliosacral screws. In: Wiss D (ed) Fractures. Lippincott, Williams & Wilkins, Philadelphia, pp 649–667
13.
go back to reference Noojin FK, Malkani AL, Haikal L et al (2000) Cross-sectional geometry of the sacral ala for safe insertion of iliosacral lag screws: a computed tomography model. J Orthop Trauma 14:31–35CrossRefPubMed Noojin FK, Malkani AL, Haikal L et al (2000) Cross-sectional geometry of the sacral ala for safe insertion of iliosacral lag screws: a computed tomography model. J Orthop Trauma 14:31–35CrossRefPubMed
14.
go back to reference Day CS, Prayson MJ, Shuler TE et al (2000) Transsacral versus modified pelvic landmarks for percutaneous iliosacral screw placement—a computed tomographic analysis and cadaveric study. Am J Orthop (Belle Mead NJ) 29:16–21 Day CS, Prayson MJ, Shuler TE et al (2000) Transsacral versus modified pelvic landmarks for percutaneous iliosacral screw placement—a computed tomographic analysis and cadaveric study. Am J Orthop (Belle Mead NJ) 29:16–21
16.
go back to reference Vanderschot P, Meuleman C, Lefevre A, Broos P (2001) Trans iliac–sacral–iliac bar stabilisation to treat bilateral lesions of the sacro–iliac joint or sacrum: anatomical considerations and clinical experience. Injury 32:587–592CrossRefPubMed Vanderschot P, Meuleman C, Lefevre A, Broos P (2001) Trans iliac–sacral–iliac bar stabilisation to treat bilateral lesions of the sacro–iliac joint or sacrum: anatomical considerations and clinical experience. Injury 32:587–592CrossRefPubMed
17.
go back to reference König M, Seidel U, Heini P (2013) Minimal-invasive percutaneous reduction and transsacral screw fixation for U-shaped fractures. J Spinal Disord Tech 00:1–7 König M, Seidel U, Heini P (2013) Minimal-invasive percutaneous reduction and transsacral screw fixation for U-shaped fractures. J Spinal Disord Tech 00:1–7
19.
go back to reference Carlson DA, Scheid DK, Maar DC et al (2000) Safe placement of S1 and S2 iliosacral screws: the “vestibule” concept. J Orthop Trauma 14:264–269CrossRefPubMed Carlson DA, Scheid DK, Maar DC et al (2000) Safe placement of S1 and S2 iliosacral screws: the “vestibule” concept. J Orthop Trauma 14:264–269CrossRefPubMed
21.
25.
Metadata
Title
Anatomical considerations for percutaneous trans ilio-sacroiliac S1 and S2 screw placement
Authors
M. A. König
R. O. Sundaram
P. Saville
S. Jehan
Bronek M. Boszczyk
Publication date
01-06-2016
Publisher
Springer Berlin Heidelberg
Published in
European Spine Journal / Issue 6/2016
Print ISSN: 0940-6719
Electronic ISSN: 1432-0932
DOI
https://doi.org/10.1007/s00586-015-4327-x

Other articles of this Issue 6/2016

European Spine Journal 6/2016 Go to the issue