Skip to main content
Top
Published in: BMC Neurology 1/2013

Open Access 01-12-2013 | Research article

An ultrasound model to calculate the brain blood outflow through collateral vessels: a pilot study

Authors: Paolo Zamboni, Francesco Sisini, Erica Menegatti, Angelo Taibi, Anna Maria Malagoni, Sandra Morovic, Mauro Gambaccini

Published in: BMC Neurology | Issue 1/2013

Login to get access

Abstract

Background

The quantification of the flow returning from the head through the cervical veins and the collaterals of the internal jugular vein (IJV), is becoming of prominent interest in clinical practice. We developed a novel model to calculate the cerebral venous return, normalized to the arterial inflow, in the different segments of the IJV.

Methods

We assessed, by established Echo Colour Doppler (ECD) methodology, the head inflow (HBinF) defined as the sum of common carotids and vertebral arteries, as well as the cerebral flow (CBF) defined as the sum of internal carotid and vertebral arteries. We also assessed the head outflow (HBoutF) defined as the sum of the measurements at the junction of the IJV and the vertebral veins. In addition, we also calculated the collateral flow index (CFI) by estimating the flow which re-enters directly into the superior vena cava as the amount of blood extrapolated by the difference between the HBinF and the HBoutF. We preliminarily tested the model by comparing ten healthy controls (HC) with ten patients affected by chronic cerebral spinal venous insufficiency (CCSVI), a condition characterized by some blockages in the IJV which are bypassed by collateral circulation.

Results

In HC the HBinF was 956+-105ml/min, whereas the HBoutF was > 90% of the HBinF, leading to a final CFI value of 1%. The last result shows that a very small amount of blood is drained by the collaterals. In upright we confirmed a reduction of the outflow through the IJV which increased CFI to 9%. When we applied the model to CCSVI, the HBinF was not significantly different from controls. In supine, the flow of CCSVI patients in the IJV junction was significantly lower (p < 0.001) while the correspondent CFI value significantly increased (61%, p < 0.0002).

Conclusions

Our preliminary application of the novel model in the clinical setting suggests the pivotal role of the collateral network in draining the blood into the superior vena cava under CCSVI condition.
Appendix
Available only for authorised users
Literature
1.
go back to reference Gisolf J, van Lieshout JJ, van Heusden K, Pott F, Stok WJ, Karemaker JM: Human cerebral venous outflow pathway depends on posture and central venous pressure. J Physiol. 2004, 560: 317-327. 10.1113/jphysiol.2004.070409.CrossRefPubMedPubMedCentral Gisolf J, van Lieshout JJ, van Heusden K, Pott F, Stok WJ, Karemaker JM: Human cerebral venous outflow pathway depends on posture and central venous pressure. J Physiol. 2004, 560: 317-327. 10.1113/jphysiol.2004.070409.CrossRefPubMedPubMedCentral
2.
go back to reference Schaller B: Physiology of cerebral venous blood flow: from experimental data in animals to normal function in humans. Brain Res Rev. 2004, 46: 243-260. 10.1016/j.brainresrev.2004.04.005.CrossRefPubMed Schaller B: Physiology of cerebral venous blood flow: from experimental data in animals to normal function in humans. Brain Res Rev. 2004, 46: 243-260. 10.1016/j.brainresrev.2004.04.005.CrossRefPubMed
3.
go back to reference Valdueza JM, von Münster T, Hoffman O, Schreiber S, Einhäupl KM: Postural dependency of the cerebral venous outflow. Lancet. 2000, 355: 200-201.CrossRefPubMed Valdueza JM, von Münster T, Hoffman O, Schreiber S, Einhäupl KM: Postural dependency of the cerebral venous outflow. Lancet. 2000, 355: 200-201.CrossRefPubMed
4.
go back to reference Doepp F, Schreiber SJ, von Münster T, Rademacher J, Klingebiel R, Valdueza JM: How does the blood leave the brain? A systematic ultrasound analysis of cerebral venous drainage patterns. Neuroradiology. 2004, 46: 565-570.CrossRefPubMed Doepp F, Schreiber SJ, von Münster T, Rademacher J, Klingebiel R, Valdueza JM: How does the blood leave the brain? A systematic ultrasound analysis of cerebral venous drainage patterns. Neuroradiology. 2004, 46: 565-570.CrossRefPubMed
5.
go back to reference Zamboni P, Morovic S, Menegatti E, Viselner G, Nicolaides AN, The Intersociety Faculty: Screening for chronic cerebrospinal venous insufficiency (CCSVI) using ultrasound. Recommendation for a protocol. Int Angiol. 2011, 30: 571-597.PubMed Zamboni P, Morovic S, Menegatti E, Viselner G, Nicolaides AN, The Intersociety Faculty: Screening for chronic cerebrospinal venous insufficiency (CCSVI) using ultrasound. Recommendation for a protocol. Int Angiol. 2011, 30: 571-597.PubMed
6.
go back to reference Zamboni P, Menegatti E, Pomidori L, Morovic S, Taibi A, Malagoni AM, Cogo AL, Gambaccini M: Does thoracic pump influence the cerebral venous return?. J Appl Physiol. 2012, 112: 904-910. 10.1152/japplphysiol.00712.2011.CrossRefPubMed Zamboni P, Menegatti E, Pomidori L, Morovic S, Taibi A, Malagoni AM, Cogo AL, Gambaccini M: Does thoracic pump influence the cerebral venous return?. J Appl Physiol. 2012, 112: 904-910. 10.1152/japplphysiol.00712.2011.CrossRefPubMed
7.
go back to reference Zamboni P, Consorti G, Galeotti R, Gianesini S, Menegatti E, Tacconi G, Carinci F: Venous collateral circulation of the extracranial cerebrospinal outflow routes. Curr Neurovasc Res. 2009, 6: 204-212. 10.2174/156720209788970054.CrossRefPubMed Zamboni P, Consorti G, Galeotti R, Gianesini S, Menegatti E, Tacconi G, Carinci F: Venous collateral circulation of the extracranial cerebrospinal outflow routes. Curr Neurovasc Res. 2009, 6: 204-212. 10.2174/156720209788970054.CrossRefPubMed
8.
go back to reference Evans DH: On the measurement of the mean velocity of blood flow over the cardiac cycle using Doppler ultrasound. Ultrasound Med Biol. 1985, 11: 735-741. 10.1016/0301-5629(85)90107-3.CrossRefPubMed Evans DH: On the measurement of the mean velocity of blood flow over the cardiac cycle using Doppler ultrasound. Ultrasound Med Biol. 1985, 11: 735-741. 10.1016/0301-5629(85)90107-3.CrossRefPubMed
9.
go back to reference Maulik D: Doppler ultrasound in obstetrics and gynaecology. 1996, Heidelberg: Springer Maulik D: Doppler ultrasound in obstetrics and gynaecology. 1996, Heidelberg: Springer
10.
go back to reference Hoskins P, Thrush A, Martin K, Whittingam T: Diagnostic Ultrasound: Physics and Equipment Diagnostic, Greenwich Medical Media. 2010, New York, NY: Cambridge University PressCrossRef Hoskins P, Thrush A, Martin K, Whittingam T: Diagnostic Ultrasound: Physics and Equipment Diagnostic, Greenwich Medical Media. 2010, New York, NY: Cambridge University PressCrossRef
11.
go back to reference Ponzini R, Vergara C, Rizzo G, Veneziani A, Roghi A, Vanzulli A, Parodi O, Redaelli A: Womersley number-based estimates of blood flow rate in Doppler analysis: in vivo validation by means of phase-contrast MRI. IEEE Trans Biomed Eng. 2010, 57: 1807-1815.CrossRefPubMed Ponzini R, Vergara C, Rizzo G, Veneziani A, Roghi A, Vanzulli A, Parodi O, Redaelli A: Womersley number-based estimates of blood flow rate in Doppler analysis: in vivo validation by means of phase-contrast MRI. IEEE Trans Biomed Eng. 2010, 57: 1807-1815.CrossRefPubMed
12.
go back to reference Li S, Hoskins PR, Anderson T, McDicken WN: Measurement of mean velocity during pulsatile flow using time-averaged maximum frequency of Doppler ultrasound waveforms. Ultrasound Med Biol. 1993, 19: 105-113. 10.1016/0301-5629(93)90002-6.CrossRefPubMed Li S, Hoskins PR, Anderson T, McDicken WN: Measurement of mean velocity during pulsatile flow using time-averaged maximum frequency of Doppler ultrasound waveforms. Ultrasound Med Biol. 1993, 19: 105-113. 10.1016/0301-5629(93)90002-6.CrossRefPubMed
13.
go back to reference Zhong Z, Song H, Chui TY, Petrig BL, Burns SA: Noninvasive measurements and analysis of blood velocity profiles in human retinal vessels. Invest Ophthalmol Vis Sci. 2011, 52: 4151-4157. 10.1167/iovs.10-6940.CrossRefPubMedPubMedCentral Zhong Z, Song H, Chui TY, Petrig BL, Burns SA: Noninvasive measurements and analysis of blood velocity profiles in human retinal vessels. Invest Ophthalmol Vis Sci. 2011, 52: 4151-4157. 10.1167/iovs.10-6940.CrossRefPubMedPubMedCentral
14.
go back to reference Vergara C, Ponzini R, Veneziani A, Redaelli A, Neglia D, Parodi O: Womersley number-based estimation of flow rate with Doppler ultrasound: sensitivity analysis and first clinical application. Comput Methods Programs Biomed. 2010, 98 (2): 151-160. 10.1016/j.cmpb.2009.09.013. MayCrossRefPubMed Vergara C, Ponzini R, Veneziani A, Redaelli A, Neglia D, Parodi O: Womersley number-based estimation of flow rate with Doppler ultrasound: sensitivity analysis and first clinical application. Comput Methods Programs Biomed. 2010, 98 (2): 151-160. 10.1016/j.cmpb.2009.09.013. MayCrossRefPubMed
15.
go back to reference Womersley JR: Flow in the larger arteries and its relation to the oscillating pressure. J Physiol. 1954, 124 (2): 31-32.PubMed Womersley JR: Flow in the larger arteries and its relation to the oscillating pressure. J Physiol. 1954, 124 (2): 31-32.PubMed
16.
go back to reference Yamamoto M, Carrillo J, Insunza A, Mari G, Ville Y: Error Introduced into Velocity Measurements by Inappropriate Doppler Angle Assignment. Ultrasound Obstet Gynecol. 2006, 28 (6): 853-854. 10.1002/uog.3847.CrossRefPubMed Yamamoto M, Carrillo J, Insunza A, Mari G, Ville Y: Error Introduced into Velocity Measurements by Inappropriate Doppler Angle Assignment. Ultrasound Obstet Gynecol. 2006, 28 (6): 853-854. 10.1002/uog.3847.CrossRefPubMed
17.
go back to reference Schoning M, Walter J, Scheel P: Estimation of Cerebral Blood Flow Through Color Duplex Sonography of the Carotid and Vertebral Arteries in Healthy Adults. Stroke. 2004, 25: 17-22.CrossRef Schoning M, Walter J, Scheel P: Estimation of Cerebral Blood Flow Through Color Duplex Sonography of the Carotid and Vertebral Arteries in Healthy Adults. Stroke. 2004, 25: 17-22.CrossRef
18.
go back to reference Mortensen JD, Talbot S, Burkart JA: Cross sectional Internal Diameters of Human Cervical and Femoral Blood Vessels: Relationship to Subject’s Sex, Age, Body Size. Anat Rec. 1990, 226 (1): 115-124. 10.1002/ar.1092260114.CrossRefPubMed Mortensen JD, Talbot S, Burkart JA: Cross sectional Internal Diameters of Human Cervical and Femoral Blood Vessels: Relationship to Subject’s Sex, Age, Body Size. Anat Rec. 1990, 226 (1): 115-124. 10.1002/ar.1092260114.CrossRefPubMed
19.
go back to reference Doepp F, Paul F, Valdueza JM, Schmierer K, Schreiber SJ: No cerebrocervical venous congestion in patients with multiple sclerosis. Ann Neurol. 2010, 68: 173-183.CrossRefPubMed Doepp F, Paul F, Valdueza JM, Schmierer K, Schreiber SJ: No cerebrocervical venous congestion in patients with multiple sclerosis. Ann Neurol. 2010, 68: 173-183.CrossRefPubMed
20.
go back to reference Bastianello S, Bergamaschi F, Viselner G, et al: An international multicenter observatory on prevalence of CCSVI in MS. BMC Neurol. 2011, in press Bastianello S, Bergamaschi F, Viselner G, et al: An international multicenter observatory on prevalence of CCSVI in MS. BMC Neurol. 2011, in press
21.
go back to reference Monti L, Menci E, Ulivelli M, Cerase A, Bartalini S, Piu P, Marotti N, Leonini S, Galluzzi P, Romano DG, Casasco AE, Venturi C: Quantitative ColourDopplerSonography evaluation of cerebral venous outflow: a comparative study between patients with multiple sclerosis and controls. PLoSOne. 2011, 6 (9): e25012-CrossRef Monti L, Menci E, Ulivelli M, Cerase A, Bartalini S, Piu P, Marotti N, Leonini S, Galluzzi P, Romano DG, Casasco AE, Venturi C: Quantitative ColourDopplerSonography evaluation of cerebral venous outflow: a comparative study between patients with multiple sclerosis and controls. PLoSOne. 2011, 6 (9): e25012-CrossRef
22.
go back to reference Mayer CA, Waltraud P, Matthias WL, Nedelmann M, Bechmann I, Ziemann , Steinmetz : The perfect crime? CCSVI not leaving a trace in MS. J Neurol Neurosurg Psychiatry. 2011, 82: 436-440. 10.1136/jnnp.2010.231613.CrossRefPubMedPubMedCentral Mayer CA, Waltraud P, Matthias WL, Nedelmann M, Bechmann I, Ziemann , Steinmetz : The perfect crime? CCSVI not leaving a trace in MS. J Neurol Neurosurg Psychiatry. 2011, 82: 436-440. 10.1136/jnnp.2010.231613.CrossRefPubMedPubMedCentral
23.
go back to reference Baracchini C, Perini P, Calabrese M, Causin F, Rinaldi F, Gallo P: No evidence of chronic cerebrospinal venous insufficiency at multiple sclerosis onset. Ann Neurol. 2011, 69: 90-99. 10.1002/ana.22228.CrossRefPubMed Baracchini C, Perini P, Calabrese M, Causin F, Rinaldi F, Gallo P: No evidence of chronic cerebrospinal venous insufficiency at multiple sclerosis onset. Ann Neurol. 2011, 69: 90-99. 10.1002/ana.22228.CrossRefPubMed
24.
go back to reference Blinkenberg M, Akeson P, Sillesen H, Lövgaard S, Sellebjerg F, Paulson OB, Siebner HR, Sørensen PS: Chronic cerebrospinal venous insufficiency and venous stenoses in multiple sclerosis. Acta Neurol Scand. 2012, 126 (6): 421-427. 10.1111/j.1600-0404.2012.01671.x.CrossRefPubMed Blinkenberg M, Akeson P, Sillesen H, Lövgaard S, Sellebjerg F, Paulson OB, Siebner HR, Sørensen PS: Chronic cerebrospinal venous insufficiency and venous stenoses in multiple sclerosis. Acta Neurol Scand. 2012, 126 (6): 421-427. 10.1111/j.1600-0404.2012.01671.x.CrossRefPubMed
25.
go back to reference McAuliffe W, Kermode AG: Mystery of Chronic Cerebrospinal Venous Insufficiency: Identical Venographic and Ultrasound Findings in Patients with MS and Controls. AJNR Am J Neuroradiol. 2013, Jan 31. [Epub ahead of print] McAuliffe W, Kermode AG: Mystery of Chronic Cerebrospinal Venous Insufficiency: Identical Venographic and Ultrasound Findings in Patients with MS and Controls. AJNR Am J Neuroradiol. 2013, Jan 31. [Epub ahead of print]
26.
go back to reference Utriainen D, Trifan G, Sethi S, Elias S, Hewett J, Feng W, Haacke EM: Magnetic resonance imaging signatures of vascular pathology in multiple sclerosis. Neurol Res. 2012, 34 (8): 780-92. 10.1179/1743132812Y.0000000078. OctCrossRefPubMed Utriainen D, Trifan G, Sethi S, Elias S, Hewett J, Feng W, Haacke EM: Magnetic resonance imaging signatures of vascular pathology in multiple sclerosis. Neurol Res. 2012, 34 (8): 780-92. 10.1179/1743132812Y.0000000078. OctCrossRefPubMed
27.
go back to reference Utriainen D, Feng W, Elias S, Latif Z, Hubbard D, Haacke EM: Using magnetic resonance imaging as a means to study chronic cerebral spinal venous insufficiency in multiple sclerosis patients. Tech Vasc Interv Radiol. 2012, 15 (2): 101-12. 10.1053/j.tvir.2012.02.003. JunCrossRefPubMed Utriainen D, Feng W, Elias S, Latif Z, Hubbard D, Haacke EM: Using magnetic resonance imaging as a means to study chronic cerebral spinal venous insufficiency in multiple sclerosis patients. Tech Vasc Interv Radiol. 2012, 15 (2): 101-12. 10.1053/j.tvir.2012.02.003. JunCrossRefPubMed
28.
go back to reference Laupacis A, Lillie E, Dueck A, Straus S, Perrier L, Burton JM, Aviv R, Thorpe K, Feasby T, Spears J: Association between chronic cerebrospinal venous insufficiency and multiple sclerosis: a meta-analysis. CMAJ. 2011, 183 (16): E1203-12.CrossRefPubMedPubMedCentral Laupacis A, Lillie E, Dueck A, Straus S, Perrier L, Burton JM, Aviv R, Thorpe K, Feasby T, Spears J: Association between chronic cerebrospinal venous insufficiency and multiple sclerosis: a meta-analysis. CMAJ. 2011, 183 (16): E1203-12.CrossRefPubMedPubMedCentral
29.
go back to reference Zivadinov R, Schirda C, Dwyer MG, Haacke ME, Weinstock-Guttman B, Menegatti E, Heininen-Brown M, Magnano C, Malagoni AM, Wack DS, Hojnacki D, Kennedy C, Carl E, Bergsland N, Hussein S, Poloni G, Bartolomei I, Salvi F, Zamboni P: Chronic cerebrospinal venous insufficiency and iron deposition on susceptibility-weighted imaging in patients with multiple sclerosis: a pilot case-control study. Int Angiol. 2010, 29 (2): 158-75.PubMed Zivadinov R, Schirda C, Dwyer MG, Haacke ME, Weinstock-Guttman B, Menegatti E, Heininen-Brown M, Magnano C, Malagoni AM, Wack DS, Hojnacki D, Kennedy C, Carl E, Bergsland N, Hussein S, Poloni G, Bartolomei I, Salvi F, Zamboni P: Chronic cerebrospinal venous insufficiency and iron deposition on susceptibility-weighted imaging in patients with multiple sclerosis: a pilot case-control study. Int Angiol. 2010, 29 (2): 158-75.PubMed
30.
go back to reference Pozniak MA, Zagzebski JA, Scanlan KA: Spectral Doppler and Color Doppler Artifacts. Radiographics. 1992, 12: 35-44.CrossRefPubMed Pozniak MA, Zagzebski JA, Scanlan KA: Spectral Doppler and Color Doppler Artifacts. Radiographics. 1992, 12: 35-44.CrossRefPubMed
31.
go back to reference Steinman AH, Yu AC, Johnston KW, Cobbold RS: Effects of beam steering in pulsed-wave ultrasound velocity estimation. Ultrasound Med Biol. 2005, 31 (8): 1073-1082. 10.1016/j.ultrasmedbio.2005.04.005.CrossRefPubMed Steinman AH, Yu AC, Johnston KW, Cobbold RS: Effects of beam steering in pulsed-wave ultrasound velocity estimation. Ultrasound Med Biol. 2005, 31 (8): 1073-1082. 10.1016/j.ultrasmedbio.2005.04.005.CrossRefPubMed
32.
go back to reference Mancini M, Morra VB, Di Donato O, et al: Multiple sclerosis: cerebral circulation time. Radiol. 2012, 262 (3): 947-955. 10.1148/radiol.11111239.CrossRef Mancini M, Morra VB, Di Donato O, et al: Multiple sclerosis: cerebral circulation time. Radiol. 2012, 262 (3): 947-955. 10.1148/radiol.11111239.CrossRef
33.
go back to reference Beggs C, Shepherd S, Zamboni P: Cerebral venous outflow resistance and interpretation of cervical plethysmography data with respect to the diagnosis of chronic cerebrospinal venous insufficiency. Phlebology. 2012, Oct 11. [Epub ahead of print] Beggs C, Shepherd S, Zamboni P: Cerebral venous outflow resistance and interpretation of cervical plethysmography data with respect to the diagnosis of chronic cerebrospinal venous insufficiency. Phlebology. 2012, Oct 11. [Epub ahead of print]
34.
go back to reference Zamboni P, Menegatti E, Conforti P, Shepherd S, Tessari M, Beggs C: Assessment of cerebral venous return by a novel plethysmography method. J Vasc Surg. 2012, 56 (3): 677-685. 10.1016/j.jvs.2012.01.074.CrossRefPubMed Zamboni P, Menegatti E, Conforti P, Shepherd S, Tessari M, Beggs C: Assessment of cerebral venous return by a novel plethysmography method. J Vasc Surg. 2012, 56 (3): 677-685. 10.1016/j.jvs.2012.01.074.CrossRefPubMed
Metadata
Title
An ultrasound model to calculate the brain blood outflow through collateral vessels: a pilot study
Authors
Paolo Zamboni
Francesco Sisini
Erica Menegatti
Angelo Taibi
Anna Maria Malagoni
Sandra Morovic
Mauro Gambaccini
Publication date
01-12-2013
Publisher
BioMed Central
Published in
BMC Neurology / Issue 1/2013
Electronic ISSN: 1471-2377
DOI
https://doi.org/10.1186/1471-2377-13-81

Other articles of this Issue 1/2013

BMC Neurology 1/2013 Go to the issue