Skip to main content
Top
Published in: Journal of Medical Systems 2/2013

01-04-2013 | Original Paper

An Awareness Approach to Analyze ECG Streaming Data

Authors: Don S., Duckwon Chung, Eunmi Choi, Dugki Min

Published in: Journal of Medical Systems | Issue 2/2013

Login to get access

Abstract

Real-time remote health monitoring systems are experiencing tremendous advancement resulting from improvements in low power, reliable sensors; yet they are still constrained to low-level interpretation. Automatic data analysis continues to be a tedious task due to a lack of efficient, reliable platforms for data analysis. In this paper, we present a system for monitoring patients remotely by emphasizing the strength of Complex Event Processing (CEP) and Situation Awareness. In this approach, the system makes decisions in a declarative way, which helps medical experts to understand the situation in a more realistic manner. The primary objective of this paper is to explicate the different components inside the system. To verify the technical feasibility of each component, the proposed system is implemented and tested using ECG data.
Literature
1.
go back to reference Lloyd-Jones, D., Adams, R., Carnethon, M., De Simone, G., Ferguson, T. B., Flegal, K., Ford, E., Furie, K., Go, A., Greenlund, K., Haase, N., Hailpern, S., Ho, M., Howard, V., Kissela, B., Kittner, S., Lackland, D., Lisabeth, L., Marelli, A., McDermott, M., Meigs, J., Mozaffarian, D., Nichol, G., O’Donnell, C., Roger, V., Rosamond, W., Sacco, R., Sorlie, P., Stafford, R., Steinberger, J., Thom, T., Wasserthiel-Smoller, S., Wong, N., Wylie-Rosett, J., and Hong, Y., ‘Heart disease and stroke statistics-2009 Update. A report from the American Heart Association Statistics Committee and Stroke statistics Subcommittee’. J. American Heart Association 119(3):e21–e181, 2009. Lloyd-Jones, D., Adams, R., Carnethon, M., De Simone, G., Ferguson, T. B., Flegal, K., Ford, E., Furie, K., Go, A., Greenlund, K., Haase, N., Hailpern, S., Ho, M., Howard, V., Kissela, B., Kittner, S., Lackland, D., Lisabeth, L., Marelli, A., McDermott, M., Meigs, J., Mozaffarian, D., Nichol, G., O’Donnell, C., Roger, V., Rosamond, W., Sacco, R., Sorlie, P., Stafford, R., Steinberger, J., Thom, T., Wasserthiel-Smoller, S., Wong, N., Wylie-Rosett, J., and Hong, Y., ‘Heart disease and stroke statistics-2009 Update. A report from the American Heart Association Statistics Committee and Stroke statistics Subcommittee’. J. American Heart Association 119(3):e21–e181, 2009.
2.
go back to reference Barbeau, S. J., Perez, R. A., Labrador, M. A., Perez, A. J., Winters, P. L., Georggi, N. I., ‘A location-aware framework for Intelligent real-time mobile applications’. IEEE CS 58–67, 2011 Barbeau, S. J., Perez, R. A., Labrador, M. A., Perez, A. J., Winters, P. L., Georggi, N. I., ‘A location-aware framework for Intelligent real-time mobile applications’. IEEE CS 58–67, 2011
3.
go back to reference Exarchos, P. T., Papaloukas, C., Fotiadis, D. I., and Michalis, L., ‘An association rule mining-based methodology for automated detection of ischemic ECG beats’. IEEE Trans on BioMed Engg 53(8):1531–1540, 2006.CrossRef Exarchos, P. T., Papaloukas, C., Fotiadis, D. I., and Michalis, L., ‘An association rule mining-based methodology for automated detection of ischemic ECG beats’. IEEE Trans on BioMed Engg 53(8):1531–1540, 2006.CrossRef
4.
go back to reference Lin, C.-T., Chang, K.-C., Lin, C.-L., Chiang, C.-C., Lu, S.-W., Chang, S.-S., Lin, B.-S., Liang, H.-Y., Chen, R.-J., Lee, Y.-T., and Ko, L.-W., An Intelligent Telecardiology system using a wearable and wireless ECG to detect atrial fibrillation. IEEE Tran on InfoTech in BioMed 14(3):726–733, 2010.CrossRef Lin, C.-T., Chang, K.-C., Lin, C.-L., Chiang, C.-C., Lu, S.-W., Chang, S.-S., Lin, B.-S., Liang, H.-Y., Chen, R.-J., Lee, Y.-T., and Ko, L.-W., An Intelligent Telecardiology system using a wearable and wireless ECG to detect atrial fibrillation. IEEE Tran on InfoTech in BioMed 14(3):726–733, 2010.CrossRef
5.
go back to reference Buttussi, F., and Chittaro, L., MOPET: A context-aware and user-adaptive wearable system for fitness training. Artif Intell Med 42(2):153–163, 2008.CrossRef Buttussi, F., and Chittaro, L., MOPET: A context-aware and user-adaptive wearable system for fitness training. Artif Intell Med 42(2):153–163, 2008.CrossRef
6.
go back to reference Woodward, B., Istepanian, H., ‘The use of underwater acoustic biotelemetry for monitoring the ECG of a swimming patient’. IEEE EMBS 121-122, 1995 Woodward, B., Istepanian, H., ‘The use of underwater acoustic biotelemetry for monitoring the ECG of a swimming patient’. IEEE EMBS 121-122, 1995
7.
go back to reference Khatib, A., Poletti, F., Bertozzi, D., Benini, L., Bechara, M., Khalifeh, H., Jantsch, A., Nabiev, R., ‘A multiprocessor system-on-chip for real time biomedical and analysis: Architectural design space exploration’. IEEE Design Automation Conf 125–130, 2006. Khatib, A., Poletti, F., Bertozzi, D., Benini, L., Bechara, M., Khalifeh, H., Jantsch, A., Nabiev, R., ‘A multiprocessor system-on-chip for real time biomedical and analysis: Architectural design space exploration’. IEEE Design Automation Conf 125–130, 2006.
8.
go back to reference Di, W., Rundensteiner, E. A., Wang, H., and Ellison, R. T., ‘Active complex event processing: Application in real-time health care’. VLDB Endowment 3(2):1545–1548, 2010. Di, W., Rundensteiner, E. A., Wang, H., and Ellison, R. T., ‘Active complex event processing: Application in real-time health care’. VLDB Endowment 3(2):1545–1548, 2010.
9.
go back to reference Wang, H., Peng, D., Wang, W., Sharif, H., Chen, H.-H., and Khoynezhad, A., ‘Resource-aware secure ECG healthcare monitoring through body sensor networks’. IEEE Wireless Communication 17(1):12–19, 2010.CrossRef Wang, H., Peng, D., Wang, W., Sharif, H., Chen, H.-H., and Khoynezhad, A., ‘Resource-aware secure ECG healthcare monitoring through body sensor networks’. IEEE Wireless Communication 17(1):12–19, 2010.CrossRef
10.
go back to reference Wood, A. D., Stankovic, J. A., Virone, G., Selavo, L., He, Z., Cao, Q., Doan, T., Wu, Y., Fang, L., and Stoleru, R., ‘Context-aware wireless sensor networks for assisted living and residential monitoring’. IEEE Netw. 22(4):26–33, 2008.CrossRef Wood, A. D., Stankovic, J. A., Virone, G., Selavo, L., He, Z., Cao, Q., Doan, T., Wu, Y., Fang, L., and Stoleru, R., ‘Context-aware wireless sensor networks for assisted living and residential monitoring’. IEEE Netw. 22(4):26–33, 2008.CrossRef
11.
go back to reference Varady, P., Benyo, Z., and Benyo, B., An open architecture patient monitoring system using standard technologies. IEEE Tran Info Tech & BioMed 6(1):95–98, 2002.CrossRef Varady, P., Benyo, Z., and Benyo, B., An open architecture patient monitoring system using standard technologies. IEEE Tran Info Tech & BioMed 6(1):95–98, 2002.CrossRef
12.
go back to reference Lin, C.-H., Shuenn-Tsong, A., and Kuo, T.-S., ‘A remote data access architecture for home-monitoring health care applications’. Elsevier Journal of Medical Engineering & Physics 29:199–204, 2007.CrossRef Lin, C.-H., Shuenn-Tsong, A., and Kuo, T.-S., ‘A remote data access architecture for home-monitoring health care applications’. Elsevier Journal of Medical Engineering & Physics 29:199–204, 2007.CrossRef
13.
go back to reference Taleb, T., Bottazzi, D., and Nasser, N., A novel middleware solution to improve ubiquitous healthcare systems aided by affective information. IEEE Tran InfoTech in BioMed 14(2):335–349, 2010.CrossRef Taleb, T., Bottazzi, D., and Nasser, N., A novel middleware solution to improve ubiquitous healthcare systems aided by affective information. IEEE Tran InfoTech in BioMed 14(2):335–349, 2010.CrossRef
14.
go back to reference Kang, K., Park, K.-J., Song, J.-J., Yoo, C.-H., and Sha, L., ‘A medical-grade wireless architecture for remote electrocardiography’. IEEE Tran InfoTech in BioMed 15(2):260–267, 2011.CrossRef Kang, K., Park, K.-J., Song, J.-J., Yoo, C.-H., and Sha, L., ‘A medical-grade wireless architecture for remote electrocardiography’. IEEE Tran InfoTech in BioMed 15(2):260–267, 2011.CrossRef
15.
go back to reference Varshney, U., A framework for supporting emergency message in wireless patient monitoring. Elsevier, Decision Support Systems 45:981–996, 2008.CrossRef Varshney, U., A framework for supporting emergency message in wireless patient monitoring. Elsevier, Decision Support Systems 45:981–996, 2008.CrossRef
16.
go back to reference Celler, B. G., Earnshaw, W., Ilsar, E. D., Betbeder-Matibet, L., Harris, M. F., Clark, R., Hesketh, T., and Lovell, N. H., ‘Remote monitoring of health status if the elderly at home. A multidisciplinary project on aging at the University of New South Wales’. International Journal of Bio-medical Computing 40:147–155, 1995.CrossRef Celler, B. G., Earnshaw, W., Ilsar, E. D., Betbeder-Matibet, L., Harris, M. F., Clark, R., Hesketh, T., and Lovell, N. H., ‘Remote monitoring of health status if the elderly at home. A multidisciplinary project on aging at the University of New South Wales’. International Journal of Bio-medical Computing 40:147–155, 1995.CrossRef
17.
go back to reference Nee, O., Hein, A., Gorath, T., Hulsmann, N., Laleci, G. B., Yuksel, M., Olduz, M., Tasyurt, I., Orhan, U., Dogac, A., Fruntelata, A., Ghiorghe, S., and Ludwig, R., ‘SAPHIRE: Intelligent healthcare monitoring based on semantic interoperability platform: Pilot applications’. IET Communication 2(2):192–201, 2008.CrossRef Nee, O., Hein, A., Gorath, T., Hulsmann, N., Laleci, G. B., Yuksel, M., Olduz, M., Tasyurt, I., Orhan, U., Dogac, A., Fruntelata, A., Ghiorghe, S., and Ludwig, R., ‘SAPHIRE: Intelligent healthcare monitoring based on semantic interoperability platform: Pilot applications’. IET Communication 2(2):192–201, 2008.CrossRef
18.
go back to reference Barnes, G. E., and Warren, S., ‘A wearable Bluetooth enabled system for home health care’. IEEE EMBS/BMES 3:1879–1880, 2002. Barnes, G. E., and Warren, S., ‘A wearable Bluetooth enabled system for home health care’. IEEE EMBS/BMES 3:1879–1880, 2002.
19.
go back to reference Figueredo, M. V. M., Dias, J. S., ‘Mobile telemedicine system for home care and patient monitoring’. IEEE EMBS, 3387–3390, 2004. Figueredo, M. V. M., Dias, J. S., ‘Mobile telemedicine system for home care and patient monitoring’. IEEE EMBS, 3387–3390, 2004.
20.
go back to reference Korhonen, I., and Parkka, J., Health monitoring in the home of the future. IEEE Eng in Med & Bio Magazine 22(3):66–73, 2003.CrossRef Korhonen, I., and Parkka, J., Health monitoring in the home of the future. IEEE Eng in Med & Bio Magazine 22(3):66–73, 2003.CrossRef
21.
go back to reference Blount, M., Batra, V. M., Capella, A. N., Ebling, M. R., Jerome, W. F., Martin, S. M., Nidd, M., Niemi, M. R., and Wright, S. P., ‘Remote health care monitoring using personal care connect’. IBM System Journal 46(1):95–113, 2007.CrossRef Blount, M., Batra, V. M., Capella, A. N., Ebling, M. R., Jerome, W. F., Martin, S. M., Nidd, M., Niemi, M. R., and Wright, S. P., ‘Remote health care monitoring using personal care connect’. IBM System Journal 46(1):95–113, 2007.CrossRef
22.
go back to reference Bottazzi, D., Corradi, A., and Montanari, R., Context-aware middleware solutions for anytime and anywhere emergency assistance to elderly people. IEEE Communication Magazine 44(4):82–90, 2006.CrossRef Bottazzi, D., Corradi, A., and Montanari, R., Context-aware middleware solutions for anytime and anywhere emergency assistance to elderly people. IEEE Communication Magazine 44(4):82–90, 2006.CrossRef
23.
go back to reference Fioratou, E., Flin, R., Glavin, R., and Patey, R., Beyond monitoring: Distributed situation awareness in anaesthesia. Br. J. Anaesth. 105(1):83–90, 2010.CrossRef Fioratou, E., Flin, R., Glavin, R., and Patey, R., Beyond monitoring: Distributed situation awareness in anaesthesia. Br. J. Anaesth. 105(1):83–90, 2010.CrossRef
24.
go back to reference Endsley, M. R., ‘Theoretical underpinning of situation awareness: A critical review’. In: Endsley, M. R., and Garland, D. J., (Eds.), Situation Awareness Analysis and Measurement, Lawrence Erlbaum, Mahwah, NJ, pp. 3–32, 2000. Endsley, M. R., ‘Theoretical underpinning of situation awareness: A critical review’. In: Endsley, M. R., and Garland, D. J., (Eds.), Situation Awareness Analysis and Measurement, Lawrence Erlbaum, Mahwah, NJ, pp. 3–32, 2000.
25.
go back to reference Endsely, M. R., ‘Towards a theory of situation awareness in dynamic systems’. Human Factors 37(1):32–64, 1995.CrossRef Endsely, M. R., ‘Towards a theory of situation awareness in dynamic systems’. Human Factors 37(1):32–64, 1995.CrossRef
26.
go back to reference Endsley, M. R., Bolte, B., and Jones, D. G., Designing for situation awareness: An approach to user centered design. Taylor & Francis, New York, 2003. Endsley, M. R., Bolte, B., and Jones, D. G., Designing for situation awareness: An approach to user centered design. Taylor & Francis, New York, 2003.
27.
go back to reference Velandia, C. D., Don, S., Cho, N-Y., Choi, E., Min, D., ‘Adaptive signal management using event processing networks’. IEEE NCM 738–745, 2010. Velandia, C. D., Don, S., Cho, N-Y., Choi, E., Min, D., ‘Adaptive signal management using event processing networks’. IEEE NCM 738–745, 2010.
28.
go back to reference Chazal, P. D., O’Dwyer, M., and Reilly, R. B., ‘Automatic classification of heartbeats using ECG morphology and heartbeat interval features’. IEEE Trans on BioMed Engg 51(7):1195–1206, 2004. Chazal, P. D., O’Dwyer, M., and Reilly, R. B., ‘Automatic classification of heartbeats using ECG morphology and heartbeat interval features’. IEEE Trans on BioMed Engg 51(7):1195–1206, 2004.
29.
go back to reference Wang, X. H., Zhang, D. Q., Gu, T., Pung, H. K., ‘Ontology based context modeling and reasoning using OWL’. IEEE PERCOMW’04, 18–22, 2004 Wang, X. H., Zhang, D. Q., Gu, T., Pung, H. K., ‘Ontology based context modeling and reasoning using OWL’. IEEE PERCOMW’04, 18–22, 2004
30.
go back to reference Moody, G. B., and Mark, R. G., The impact of the MIT-BIT arrhythmia database. IEEE Eng. Med. Biol Mag 20(3):45–50, 2001.CrossRef Moody, G. B., and Mark, R. G., The impact of the MIT-BIT arrhythmia database. IEEE Eng. Med. Biol Mag 20(3):45–50, 2001.CrossRef
31.
go back to reference Lee, S., Kim, J., and Lee, M., A real-time ECG data compression and transmission algorithm for an e-health device. IEEE Trans on BioMed Engg 58(9):2448–2455, 2011.CrossRef Lee, S., Kim, J., and Lee, M., A real-time ECG data compression and transmission algorithm for an e-health device. IEEE Trans on BioMed Engg 58(9):2448–2455, 2011.CrossRef
Metadata
Title
An Awareness Approach to Analyze ECG Streaming Data
Authors
Don S.
Duckwon Chung
Eunmi Choi
Dugki Min
Publication date
01-04-2013
Publisher
Springer US
Published in
Journal of Medical Systems / Issue 2/2013
Print ISSN: 0148-5598
Electronic ISSN: 1573-689X
DOI
https://doi.org/10.1007/s10916-012-9901-8

Other articles of this Issue 2/2013

Journal of Medical Systems 2/2013 Go to the issue