01-04-2017 | Laboratory Investigation

An Attempt to Shorten Loading Time of Epirubicin into DC Beads® Using Vibration and a Sieve

Authors: Akinaga Sonoda, Norihisa Nitta, Takefumi Yamamoto, Yuki Tomozawa, Shinichi Ohta, Shobu Watanabe, Kiyoshi Murata

Published in: CardioVascular and Interventional Radiology | Issue 4/2017

Login to get access

Abstract

Purpose

We investigated the possibility of shortening the time required for loading epirubicin into calibrated polyvinyl alcohol-based hydrogel beads (DC Beads®) to be used for transarterial chemoembolization.

Method

After separating the beads suspended in phosphate-buffered saline (PBS) solution by the use of a sieve (clearance 75 µm), epirubicin hydrochloride (EH) was loaded for 20, 30, or 60 s under vibration into DC beads. The EH loading rate into conventionally prepared (control) beads, i.e., beads loaded for 30 min without vibration, and vibration-loaded beads were calculated from the residual EH concentration in the bead-depleted EH solution. The amount of EH eluted from conventionally and vibration-loaded samples into a PBS solution (pH 7.0) was measured at 15 and 30 min and 1, 2, 6, 12, and 24 h. We also recorded the inhibitory effect of the PBS solution on the loading time. Using frozen sections, the EH load in the beads was evaluated visually under a fluorescence microscope.

Results

Spectrophotometry (495 nm) showed that the loading rate was 98.98 ± 0.34, 99.02 ± 0.32, and 99.50 ± 0.11 % with 20-, 30-, and 60-s vibration, respectively. The eluted rate was statistically similar between vibration- and statically loaded (control) beads. The PBS solution hampered EH loading into the beads. Visually, the distribution of EH in conventionally and vibration-loaded DC beads was similar.

Discussion

The use of vibration and the removal of PBS solution when epirubicin hydrochloride was loaded into DC beads dramatically shortened the loading time of epirubicin hydrochloride into DC beads.
Literature
1.
go back to reference Aliberti C, Fiorentini G, Muzzio PC, et al. Trans-arterial chemoembolization of metastatic colorectal carcinoma to the liver adopting DC Bead®, drug-eluting bead loaded with irinotecan: results of a phase II clinical study. Anticancer Res. 2011;31(12):4581–7.PubMed Aliberti C, Fiorentini G, Muzzio PC, et al. Trans-arterial chemoembolization of metastatic colorectal carcinoma to the liver adopting DC Bead®, drug-eluting bead loaded with irinotecan: results of a phase II clinical study. Anticancer Res. 2011;31(12):4581–7.PubMed
2.
go back to reference Boyd GE, Adamson AW, Myers LS Jr. The exchange adsorption of ions from aqueous solutions by organic zeolites. II kinetics1. J Am Chem Soc. 1947;69(11):2836–48.CrossRefPubMed Boyd GE, Adamson AW, Myers LS Jr. The exchange adsorption of ions from aqueous solutions by organic zeolites. II kinetics1. J Am Chem Soc. 1947;69(11):2836–48.CrossRefPubMed
3.
go back to reference Gonzalez MV, Tang Y, Phillips GJ, et al. Doxorubicin eluting beads—2: methods for evaluating drug elution and in vitro: in vivo correlation. J Mater Sci: Mater Med. 2008;19(2):767–75. Gonzalez MV, Tang Y, Phillips GJ, et al. Doxorubicin eluting beads—2: methods for evaluating drug elution and in vitro: in vivo correlation. J Mater Sci: Mater Med. 2008;19(2):767–75.
4.
go back to reference Lewis AL, Gonzalez MV, Leppard SW, et al. Doxorubicin eluting beads—1: effects of drug loading on bead characteristics and drug distribution. J Mater Sci: Mater Med. 2007;18(9):1691–9. Lewis AL, Gonzalez MV, Leppard SW, et al. Doxorubicin eluting beads—1: effects of drug loading on bead characteristics and drug distribution. J Mater Sci: Mater Med. 2007;18(9):1691–9.
5.
go back to reference Lewis AL, Gonzalez MV, Lloyd AW, et al. DC bead: in vitro characterization of a drug-delivery device for transarterial chemoembolization. J Vasc Interv Radiol. 2006;17(2 Pt 1):335–42.CrossRefPubMed Lewis AL, Gonzalez MV, Lloyd AW, et al. DC bead: in vitro characterization of a drug-delivery device for transarterial chemoembolization. J Vasc Interv Radiol. 2006;17(2 Pt 1):335–42.CrossRefPubMed
6.
go back to reference Lewis AL, Taylor RR, Hall B, Gonzalez MV, Willis SL, Stratford PW. Pharmacokinetic and safety study of doxorubicin-eluting beads in a porcine model of hepatic arterial embolization. J Vasc Interv Radiol. 2006;17(8):1335–43.CrossRefPubMed Lewis AL, Taylor RR, Hall B, Gonzalez MV, Willis SL, Stratford PW. Pharmacokinetic and safety study of doxorubicin-eluting beads in a porcine model of hepatic arterial embolization. J Vasc Interv Radiol. 2006;17(8):1335–43.CrossRefPubMed
Metadata
Title
An Attempt to Shorten Loading Time of Epirubicin into DC Beads® Using Vibration and a Sieve
Authors
Akinaga Sonoda
Norihisa Nitta
Takefumi Yamamoto
Yuki Tomozawa
Shinichi Ohta
Shobu Watanabe
Kiyoshi Murata
Publication date
01-04-2017
Publisher
Springer US
Published in
CardioVascular and Interventional Radiology / Issue 4/2017
Print ISSN: 0174-1551
Electronic ISSN: 1432-086X
DOI
https://doi.org/10.1007/s00270-016-1354-x

Other articles of this Issue 4/2017

CardioVascular and Interventional Radiology 4/2017 Go to the issue