Abstract

Background

Adjustable single-incision mini-sling (SIMS) is a new category of SIMS for stress urinary incontinence (SUI). The aim of this study was to compare the efficacy and safety of adjustable single-incision mini-sling with other slings.

Methods

Literature search in databases such as Pubmed, and Conchrane Library was performed up to December, 2015. The outcomes including cure rate, operation time, postoperative pain score and complications were reanalyzed. The pooled relative risk (RR) and mean difference (MD) with their 95% confidence interval (95% CI) were calculated by RevMan v5.0.

Results

Eight studies with 1093 SUI female patients were included. There was no significant difference between adjustable SIMS and other slings (transobturator slings and MiniArc) in patients subjective cure rate and objective cure rate. In addition, adjustable SIMS was associated with a significantly shorter operative time and lower postoperative pain score when comparing adjustable SIMS with transobturator tape (MD = − 1.35; 95%CI: -2.24 to − 0.46, P = 0.003). For the complications, there was also no significant difference between adjustable SIMS and transobturator slings.

Conclusions

Adjustable SIMS had equally efficacy for SUI compared with transobturator slings and MiniArc. However, the significantly shorter operative time and lower postoperative pain score than transobturator tape supported the clinical application of adjustable SIMS.
Literature
1.
go back to reference Donkelaar CST, Rosier PFWM, Kort LMOD: 990 international continence society definition of detrusor underactivity; analysis of clinical parameters and comparison with contractility grading methods. Eur Urol Suppl 2016, 15(3):e975-e975. Donkelaar CST, Rosier PFWM, Kort LMOD: 990 international continence society definition of detrusor underactivity; analysis of clinical parameters and comparison with contractility grading methods. Eur Urol Suppl 2016, 15(3):e975-e975.
2.
go back to reference Kavia R, Rashid T, Ockrim J. Stress urinary incontinence. J Clin Urol. 2013;6(6):377–90.CrossRef Kavia R, Rashid T, Ockrim J. Stress urinary incontinence. J Clin Urol. 2013;6(6):377–90.CrossRef
3.
go back to reference Fritel X, Fauconnier A, Bader G, Cosson M, Debodinance P, Deffieux X, Denys P, Dompeyre P, Faltin D, Fatton B. Diagnosis and management of adult female stress urinary incontinence: guidelines for clinical practice from the French College of Gynaecologists and Obstetricians. Eur J Obstet Gynecol Reprod Biol. 2010;151(1):14–9.CrossRefPubMed Fritel X, Fauconnier A, Bader G, Cosson M, Debodinance P, Deffieux X, Denys P, Dompeyre P, Faltin D, Fatton B. Diagnosis and management of adult female stress urinary incontinence: guidelines for clinical practice from the French College of Gynaecologists and Obstetricians. Eur J Obstet Gynecol Reprod Biol. 2010;151(1):14–9.CrossRefPubMed
4.
go back to reference Fong ED, Nitti VW. REVIEW ARTICLE: mid-urethral synthetic slings for female stress urinary incontinence. BJU Int. 2010;106(5):596–608.CrossRefPubMed Fong ED, Nitti VW. REVIEW ARTICLE: mid-urethral synthetic slings for female stress urinary incontinence. BJU Int. 2010;106(5):596–608.CrossRefPubMed
5.
go back to reference Nilsson C, Palva K, Aarnio R, Morcos E, Falconer C. Seventeen years’ follow-up of the tension-free vaginal tape procedure for female stress urinary incontinence. Int Urogynecol J. 2013;24(8):1265–9.CrossRefPubMed Nilsson C, Palva K, Aarnio R, Morcos E, Falconer C. Seventeen years’ follow-up of the tension-free vaginal tape procedure for female stress urinary incontinence. Int Urogynecol J. 2013;24(8):1265–9.CrossRefPubMed
6.
go back to reference Kroon N, Smith K, Gill J: Bowel injury at TVT: an issue of consent. Journal of Obstetrics & Gynecology 2007, 27(7):741-741. Kroon N, Smith K, Gill J: Bowel injury at TVT: an issue of consent. Journal of Obstetrics & Gynecology 2007, 27(7):741-741.
7.
go back to reference Agostini A, Bretelle F, Franchi F, Roger V, Cravello L, Blanc B. Immediate complications of tension-free vaginal tape (TVT): results of a French survey. Eur J Obstet Gynecol Reprod Biol. 2006;124(2):237–9.CrossRefPubMed Agostini A, Bretelle F, Franchi F, Roger V, Cravello L, Blanc B. Immediate complications of tension-free vaginal tape (TVT): results of a French survey. Eur J Obstet Gynecol Reprod Biol. 2006;124(2):237–9.CrossRefPubMed
8.
go back to reference Serati M, Braga A, Cattoni E, Siesto G, Cromi A, Ghezzi F, Salvatore S. Transobturator vaginal tape for the treatment of stress urinary incontinence in elderly women without concomitant pelvic organ prolapse: is it effective and safe? Eur J Obstet Gynecol Reprod Biol. 2013;166(1):107–10.CrossRefPubMed Serati M, Braga A, Cattoni E, Siesto G, Cromi A, Ghezzi F, Salvatore S. Transobturator vaginal tape for the treatment of stress urinary incontinence in elderly women without concomitant pelvic organ prolapse: is it effective and safe? Eur J Obstet Gynecol Reprod Biol. 2013;166(1):107–10.CrossRefPubMed
9.
go back to reference Potić M, Ignjatović I, Bašić D. Tension free vaginal tape (TVT) vs transobturator tape (TOT) complications and outcomes. Acta Chirurgica Iugoslavica. 2014;61(1):81–4.CrossRefPubMed Potić M, Ignjatović I, Bašić D. Tension free vaginal tape (TVT) vs transobturator tape (TOT) complications and outcomes. Acta Chirurgica Iugoslavica. 2014;61(1):81–4.CrossRefPubMed
10.
go back to reference Bozkurt M, Yumru A, Salman S. Assessment of perioperative, early, and late postoperative complications of the inside-out transobturator tape procedure in the treatment of stress urinary incontinence. Clin Exper Obstet Gynecol. 2014;42(1):82–9. Bozkurt M, Yumru A, Salman S. Assessment of perioperative, early, and late postoperative complications of the inside-out transobturator tape procedure in the treatment of stress urinary incontinence. Clin Exper Obstet Gynecol. 2014;42(1):82–9.
11.
go back to reference Neuman M, Sosnovski V, Kais M, Ophir E, Bornstein J. Transobturator vs single-incision suburethral mini-slings for treatment of female stress urinary incontinence: early postoperative pain and 3-year follow-up. J Minim Invasive Gynecol. 2011;18(6):769–73.CrossRefPubMed Neuman M, Sosnovski V, Kais M, Ophir E, Bornstein J. Transobturator vs single-incision suburethral mini-slings for treatment of female stress urinary incontinence: early postoperative pain and 3-year follow-up. J Minim Invasive Gynecol. 2011;18(6):769–73.CrossRefPubMed
12.
go back to reference Oliveira R, Botelho F, Silva P, Resende A, Silva C, Dinis P, Cruz F. Exploratory study assessing efficacy and complications of TVT-O, TVT-Secur, and mini-arc: results at 12-month follow-up. Eur Urol. 2011;59(6):940–4.CrossRefPubMed Oliveira R, Botelho F, Silva P, Resende A, Silva C, Dinis P, Cruz F. Exploratory study assessing efficacy and complications of TVT-O, TVT-Secur, and mini-arc: results at 12-month follow-up. Eur Urol. 2011;59(6):940–4.CrossRefPubMed
13.
go back to reference Mostafa A, Lim CP, Hopper L, Madhuvrata P, Abdel-Fattah M. Single-incision mini-slings versus standard midurethral slings in surgical management of female stress urinary incontinence: an updated systematic review and meta-analysis of effectiveness and complications. Eur Urol. 2013;29:00860–9. Mostafa A, Lim CP, Hopper L, Madhuvrata P, Abdel-Fattah M. Single-incision mini-slings versus standard midurethral slings in surgical management of female stress urinary incontinence: an updated systematic review and meta-analysis of effectiveness and complications. Eur Urol. 2013;29:00860–9.
14.
go back to reference Meschia M, Barbacini P, Baccichet R, Buonaguidi A, Maffiolini M, Ricci L, Braghin C, Brusati V, Dell’Utri C, Spreafico L. Short-term outcomes with the Ajust™ system: a new single incision sling for the treatment of stress urinary incontinence. Int Urogynecol J. 2011;22(2):177–82.CrossRefPubMed Meschia M, Barbacini P, Baccichet R, Buonaguidi A, Maffiolini M, Ricci L, Braghin C, Brusati V, Dell’Utri C, Spreafico L. Short-term outcomes with the Ajust™ system: a new single incision sling for the treatment of stress urinary incontinence. Int Urogynecol J. 2011;22(2):177–82.CrossRefPubMed
15.
go back to reference Abdel-Fattah M, Agur W, Abdel-All M, Guerrero K, Allam M, Mackintosh A, Mostafa A, Yousef M. Prospective multi-Centre study of adjustable single-incision mini-sling (Ajust®) in the management of stress urinary incontinence in women: 1-year follow-up study. BJU Int. 2012;109(6):880–6.CrossRefPubMed Abdel-Fattah M, Agur W, Abdel-All M, Guerrero K, Allam M, Mackintosh A, Mostafa A, Yousef M. Prospective multi-Centre study of adjustable single-incision mini-sling (Ajust®) in the management of stress urinary incontinence in women: 1-year follow-up study. BJU Int. 2012;109(6):880–6.CrossRefPubMed
16.
go back to reference Martan A, Krhut J, MAŠATA J, ŠVABÍK K, HALAŠKA M, HORČIČKA L, Zachoval R. Prospective randomized study of MiniArc and Ajust single incision sling procedures. LUTS. 2014;6(3):172–4.PubMed Martan A, Krhut J, MAŠATA J, ŠVABÍK K, HALAŠKA M, HORČIČKA L, Zachoval R. Prospective randomized study of MiniArc and Ajust single incision sling procedures. LUTS. 2014;6(3):172–4.PubMed
17.
go back to reference Moher D, Liberati A, Tetzlaff J, Altman DG. Reprint—preferred reporting items for systematic reviews and meta-analyses: the PRISMA statement. Phys Ther. 2009;89(9):873–80.PubMed Moher D, Liberati A, Tetzlaff J, Altman DG. Reprint—preferred reporting items for systematic reviews and meta-analyses: the PRISMA statement. Phys Ther. 2009;89(9):873–80.PubMed
18.
go back to reference Jadad AR, Moore RA, Carroll D, Jenkinson C, Reynolds DJM, Gavaghan DJ, McQuay HJ. Assessing the quality of reports of randomized clinical trials: is blinding necessary? Control Clin Trials. 1996;17(1):1–12.CrossRefPubMed Jadad AR, Moore RA, Carroll D, Jenkinson C, Reynolds DJM, Gavaghan DJ, McQuay HJ. Assessing the quality of reports of randomized clinical trials: is blinding necessary? Control Clin Trials. 1996;17(1):1–12.CrossRefPubMed
19.
go back to reference Higgins JPT, Altman DG, Gøtzsche PC, Jüni P, Moher D, Oxman AD, Savović J, Schulz KF, Weeks L, Sterne JAC: The Cochrane Collaboration's tool for assessing risk of bias in randomised trials. BMJ 2011, 343(oct18 2):d5928-d5928. Higgins JPT, Altman DG, Gøtzsche PC, Jüni P, Moher D, Oxman AD, Savović J, Schulz KF, Weeks L, Sterne JAC: The Cochrane Collaboration's tool for assessing risk of bias in randomised trials. BMJ 2011, 343(oct18 2):d5928-d5928.
20.
go back to reference Boyers D, Kilonzo M, Mostafa A, Abdel-Fattah M. Comparison of an adjustable anchored single-incision mini-sling, Ajust®, with a standard mid-urethral sling, TVT-OTM: a health economic evaluation. BJU Int. 2013;112(8):1169–77.CrossRefPubMed Boyers D, Kilonzo M, Mostafa A, Abdel-Fattah M. Comparison of an adjustable anchored single-incision mini-sling, Ajust®, with a standard mid-urethral sling, TVT-OTM: a health economic evaluation. BJU Int. 2013;112(8):1169–77.CrossRefPubMed
21.
go back to reference Grigoriadis C, Bakas P, Derpapas A, Creatsa M, Liapis A. Tension-free vaginal tape obturator versus Ajust adjustable single incision sling procedure in women with urodynamic stress urinary incontinence. Eur J Obstet Gynecol Reprod Biol. 2013;170(2):563–6.CrossRefPubMed Grigoriadis C, Bakas P, Derpapas A, Creatsa M, Liapis A. Tension-free vaginal tape obturator versus Ajust adjustable single incision sling procedure in women with urodynamic stress urinary incontinence. Eur J Obstet Gynecol Reprod Biol. 2013;170(2):563–6.CrossRefPubMed
22.
go back to reference Schweitzer KJ, Milani AL, van Eijndhoven HW, Gietelink DA, Hallensleben E, Cromheecke G-J, van der Vaart CH. Postoperative pain after adjustable single-incision or Transobturator sling for incontinence: a randomized controlled trial. Obstet Gynecol. 2015;125(1):27–34.CrossRefPubMed Schweitzer KJ, Milani AL, van Eijndhoven HW, Gietelink DA, Hallensleben E, Cromheecke G-J, van der Vaart CH. Postoperative pain after adjustable single-incision or Transobturator sling for incontinence: a randomized controlled trial. Obstet Gynecol. 2015;125(1):27–34.CrossRefPubMed
23.
go back to reference Dati S, Rombolà P, Cappello S, Piccione E. M432 single-incision minisling (ajust) vs obturator tension-free vaginal shortened tape (tvt-abbrevo) in surgical management of female stress urinary incontinence. Int J Gynecol Obstet. 2012;119:S670.CrossRef Dati S, Rombolà P, Cappello S, Piccione E. M432 single-incision minisling (ajust) vs obturator tension-free vaginal shortened tape (tvt-abbrevo) in surgical management of female stress urinary incontinence. Int J Gynecol Obstet. 2012;119:S670.CrossRef
24.
go back to reference Mostafa A, Agur W, Abdel-All M, Guerrero K, Lim C, Allam M, Yousef M, N’Dow J, Abdel-Fattah M. A multicentre prospective randomised study of single-incision mini-sling (Ajust®) versus tension-free vaginal tape-obturator (TVT-O™) in the management of female stress urinary incontinence: pain profile and short-term outcomes. Eur J Obstet Gynecol Reprod Biol. 2012;165(1):115–21.CrossRefPubMed Mostafa A, Agur W, Abdel-All M, Guerrero K, Lim C, Allam M, Yousef M, N’Dow J, Abdel-Fattah M. A multicentre prospective randomised study of single-incision mini-sling (Ajust®) versus tension-free vaginal tape-obturator (TVT-O™) in the management of female stress urinary incontinence: pain profile and short-term outcomes. Eur J Obstet Gynecol Reprod Biol. 2012;165(1):115–21.CrossRefPubMed
25.
go back to reference Masata J, Svabik K, Zvara K, Hubka P, Toman A, Martan A. Comparison of the efficacy of tension-free vaginal tape obturator (TVT-O) and single-incision tension-free vaginal tape (Ajust™) in the treatment of female stress urinary incontinence: a 1-year follow-up randomized trial. Int Urogynecol J. 2016;27(10):1–9. Masata J, Svabik K, Zvara K, Hubka P, Toman A, Martan A. Comparison of the efficacy of tension-free vaginal tape obturator (TVT-O) and single-incision tension-free vaginal tape (Ajust™) in the treatment of female stress urinary incontinence: a 1-year follow-up randomized trial. Int Urogynecol J. 2016;27(10):1–9.
26.
go back to reference Xing X, Yue S, Xia Z. A comparison between adjustable single-incision sling and tension-free vaginal tape-obturator in treating stress urinary incontinence. Arch Gynecol Obstet. 2016;293(2):1–7. Xing X, Yue S, Xia Z. A comparison between adjustable single-incision sling and tension-free vaginal tape-obturator in treating stress urinary incontinence. Arch Gynecol Obstet. 2016;293(2):1–7.
27.
go back to reference Wang SM, Zhang ZY, Liu CD, Wang SZ. Study on concomitant surgical correction of pelvic organ prolapse and TVT-O for treatment of stress urinary incontinence. Zhonghua Fu Chan Ke Za Zhi. 2013;48(7):494–8.PubMed Wang SM, Zhang ZY, Liu CD, Wang SZ. Study on concomitant surgical correction of pelvic organ prolapse and TVT-O for treatment of stress urinary incontinence. Zhonghua Fu Chan Ke Za Zhi. 2013;48(7):494–8.PubMed
28.
go back to reference Zhang P, Fan B, Han H, Xu Y, Wang B, Zhang X. Meta-analysis of female stress urinary incontinence treatments with adjustable single-incision mini-slings and transobturator tension-free vaginal tape surgeries. BMC Urol. 2015;15(1):64.CrossRefPubMedPubMedCentral Zhang P, Fan B, Han H, Xu Y, Wang B, Zhang X. Meta-analysis of female stress urinary incontinence treatments with adjustable single-incision mini-slings and transobturator tension-free vaginal tape surgeries. BMC Urol. 2015;15(1):64.CrossRefPubMedPubMedCentral
29.
go back to reference Zhang X. Initial study with the Ajust~(TM) system:a single incision adjustable sling for the treatment of female stress urinary incontinence. J Clin Urol. 2012; Zhang X. Initial study with the Ajust~(TM) system:a single incision adjustable sling for the treatment of female stress urinary incontinence. J Clin Urol. 2012;
30.
go back to reference Palomba S, Oppedisano R, Torella M, Falbo A, Maiorana A, Materazzo C, Tartaglia E, Tolino A, Mastrantonio P, Alio L. A randomized controlled trial comparing three vaginal kits of single-incision mini-slings for stress urinary incontinence: surgical data. Eur J Obstet Gynecol Reprod Biol. 2012;163(1):108–12.CrossRefPubMed Palomba S, Oppedisano R, Torella M, Falbo A, Maiorana A, Materazzo C, Tartaglia E, Tolino A, Mastrantonio P, Alio L. A randomized controlled trial comparing three vaginal kits of single-incision mini-slings for stress urinary incontinence: surgical data. Eur J Obstet Gynecol Reprod Biol. 2012;163(1):108–12.CrossRefPubMed
Metadata
Title
Adjustable single-incision mini-slings (Ajust®) versus other slings in surgical management of female stress urinary incontinence: a meta-analysis of effectiveness and complications
Authors
Fuding Bai
Jimin Chen
Zhewei Zhang
Yichun Zheng
Jiaming Wen
Xiawa Mao
Nan Zhang
Publication date
01-12-2018
Publisher
BioMed Central
Published in
BMC Urology / Issue 1/2018
Electronic ISSN: 1471-2490
DOI
https://doi.org/10.1186/s12894-018-0357-0