Adaptations of aortic and pulmonary artery flow parameters measured by phase-contrast magnetic resonance angiography during supine aerobic exercise

Authors: Guido E. Pieles, Gergely Szantho, Jonathan C. L. Rodrigues, Christopher B. Lawton, A. Graham Stuart, Chiara Bucciarelli-Ducci, Mark S. Turner, Craig A. Williams, Robert M. R. Tulloh, Mark C. K. Hamilton

Published in: European Journal of Applied Physiology | Issue 5/2014

Login to get access

Abstract

Purpose

Increased oxygen uptake and utilisation during exercise depend on adequate adaptations of systemic and pulmonary vasculature. Recent advances in magnetic resonance imaging techniques allow for direct quantification of aortic and pulmonary blood flow using phase-contrast magnetic resonance angiography (PCMRA). This pilot study tested quantification of aortic and pulmonary haemodynamic adaptations to moderate aerobic supine leg exercise using PCMRA.

Methods

Nine adult healthy volunteers underwent pulse gated free breathing PCMRA while performing heart rate targeted aerobic lower limb exercise. Flow was assessed in mid ascending and mid descending thoracic aorta (AO) and main pulmonary artery (MPA) during exercise at 180 % of individual resting heart rate. Flow sequence analysis was performed by experienced operators using commercial offline software (Argus, Siemens Medical Systems).

Results

Exercise related increase in HR (rest: 69 ± 10 b min−1, exercise: 120 ± 13 b min−1) resulted in cardiac output increase (from 6.5 ± 1.4 to 12.5 ± 1.8 L min−1). At exercise, ascending aorta systolic peak velocity increased from 89 ± 14 to 122 ± 34 cm s−1 (p = 0.016), descending thoracic aorta systolic peak velocity increased from 104 ± 14 to 144 ± 33 cm s−1 (p = 0.004), MPA systolic peak velocity from 86 ± 18 to 140 ± 48 cm s−1 (p = 0.007), ascending aorta systolic peak flow rate from 415 ± 83 to 550 ± 135 mL s−1 (p = 0.002), descending thoracic aorta systolic peak flow rate from 264 ± 70 to 351 ± 82 mL s−1 (p = 0.004) and MPA systolic peak flow rate from 410 ± 80 to 577 ± 180 mL s−1 (p = 0.006).

Conclusion

Quantitative blood flow and velocity analysis during exercise using PCMRA is feasible and detected a steep exercise flow and velocity increase in the aorta and MPA. Exercise PCMRA can serve as a research and clinical tool to help quantify exercise blood flow adaptations in health and disease and investigate patho-physiological mechanisms in cardio-pulmonary disease.
Appendix
Available only for authorised users
Literature
go back to reference Arheden H, Holmqvist C, Thilen U, Hanseus K, Bjorkhem G, Pahlm O, Laurin S, Stahlberg F (1999) Left-to-right cardiac shunts: comparison of measurements obtained with MR velocity mapping and with radionuclide angiography. Radiology 211(2):453–458PubMedCrossRef Arheden H, Holmqvist C, Thilen U, Hanseus K, Bjorkhem G, Pahlm O, Laurin S, Stahlberg F (1999) Left-to-right cardiac shunts: comparison of measurements obtained with MR velocity mapping and with radionuclide angiography. Radiology 211(2):453–458PubMedCrossRef
go back to reference Balady GJ, Arena R, Sietsema K, Myers J, Coke L, Fletcher GF, Forman D, Franklin B, Guazzi M, Gulati M, Keteyian SJ, Lavie CJ, Macko R, Mancini D, Milani RV (2010) Clinician’s guide to cardiopulmonary exercise testing in adults: a scientific statement from the American Heart Association. Circulation 122(2):191–225. doi:10.1161/CIR.0b013e3181e52e69 PubMedCrossRef Balady GJ, Arena R, Sietsema K, Myers J, Coke L, Fletcher GF, Forman D, Franklin B, Guazzi M, Gulati M, Keteyian SJ, Lavie CJ, Macko R, Mancini D, Milani RV (2010) Clinician’s guide to cardiopulmonary exercise testing in adults: a scientific statement from the American Heart Association. Circulation 122(2):191–225. doi:10.​1161/​CIR.​0b013e3181e52e69​ PubMedCrossRef
go back to reference Bassett DR Jr, Howley ET (2000) Limiting factors for maximum oxygen uptake and determinants of endurance performance. Med Sci Sports Exerc 32(1):70–84PubMedCrossRef Bassett DR Jr, Howley ET (2000) Limiting factors for maximum oxygen uptake and determinants of endurance performance. Med Sci Sports Exerc 32(1):70–84PubMedCrossRef
go back to reference Beerbaum P, Korperich H, Gieseke J, Barth P, Peuster M, Meyer H (2005) Blood flow quantification in adults by phase-contrast MRI combined with SENSE––a validation study. J Cardiovasc Magn Reson 7(2):361–369PubMedCrossRef Beerbaum P, Korperich H, Gieseke J, Barth P, Peuster M, Meyer H (2005) Blood flow quantification in adults by phase-contrast MRI combined with SENSE––a validation study. J Cardiovasc Magn Reson 7(2):361–369PubMedCrossRef
go back to reference Bestler M, Alt E, Montoya P, Schandry R (1992) Effect of body posture on heart rate and cardiocirculatory parameters in stress––implications for frequency-adapted pacemaker systems. Z Kardiol 81(1):25–29PubMed Bestler M, Alt E, Montoya P, Schandry R (1992) Effect of body posture on heart rate and cardiocirculatory parameters in stress––implications for frequency-adapted pacemaker systems. Z Kardiol 81(1):25–29PubMed
go back to reference Bevegard S, Holmgren A, Jonsson B (1963) Circulatory studies in well trained athletes at rest and during heavy exercise. with special reference to stroke volume and the influence of body position. Acta Physiol Scand 57:26–50PubMedCrossRef Bevegard S, Holmgren A, Jonsson B (1963) Circulatory studies in well trained athletes at rest and during heavy exercise. with special reference to stroke volume and the influence of body position. Acta Physiol Scand 57:26–50PubMedCrossRef
go back to reference Flamm SD, Taki J, Moore R, Lewis SF, Keech F, Maltais F, Ahmad M, Callahan R, Dragotakes S, Alpert N et al (1990) Redistribution of regional and organ blood volume and effect on cardiac function in relation to upright exercise intensity in healthy human subjects. Circulation 81(5):1550–1559PubMedCrossRef Flamm SD, Taki J, Moore R, Lewis SF, Keech F, Maltais F, Ahmad M, Callahan R, Dragotakes S, Alpert N et al (1990) Redistribution of regional and organ blood volume and effect on cardiac function in relation to upright exercise intensity in healthy human subjects. Circulation 81(5):1550–1559PubMedCrossRef
go back to reference Granath A, Jonsson B, Strandell T (1964) Circulation in healthy old men, studied by right heart catheterization at rest and during exercise in supine and sitting position. Acta Med Scand 176:425–446PubMedCrossRef Granath A, Jonsson B, Strandell T (1964) Circulation in healthy old men, studied by right heart catheterization at rest and during exercise in supine and sitting position. Acta Med Scand 176:425–446PubMedCrossRef
go back to reference Groepenhoff H, Holverda S, Marcus JT, Postmus PE, Boonstra A, Vonk-Noordegraaf A (2007) Stroke volume response during exercise measured by acetylene uptake and MRI. Physiol Meas 28(1):1–11PubMedCrossRef Groepenhoff H, Holverda S, Marcus JT, Postmus PE, Boonstra A, Vonk-Noordegraaf A (2007) Stroke volume response during exercise measured by acetylene uptake and MRI. Physiol Meas 28(1):1–11PubMedCrossRef
go back to reference Higginbotham MB, Morris KG, Williams RS, McHale PA, Coleman RE, Cobb FR (1986) Regulation of stroke volume during submaximal and maximal upright exercise in normal man. Circ Res 58(2):281–291PubMedCrossRef Higginbotham MB, Morris KG, Williams RS, McHale PA, Coleman RE, Cobb FR (1986) Regulation of stroke volume during submaximal and maximal upright exercise in normal man. Circ Res 58(2):281–291PubMedCrossRef
go back to reference La Gerche A, Heidbuchel H, Burns AT, Mooney DJ, Taylor AJ, Pfluger HB, Inder WJ, Macisaac AI, Prior DL (2011) Disproportionate exercise load and remodeling of the athlete’s right ventricle. Med Sci Sports Exerc 43(6):974–981. doi:10.1249/MSS.0b013e31820607a3 PubMedCrossRef La Gerche A, Heidbuchel H, Burns AT, Mooney DJ, Taylor AJ, Pfluger HB, Inder WJ, Macisaac AI, Prior DL (2011) Disproportionate exercise load and remodeling of the athlete’s right ventricle. Med Sci Sports Exerc 43(6):974–981. doi:10.​1249/​MSS.​0b013e31820607a3​ PubMedCrossRef
go back to reference La Gerche A, Burns AT, Mooney DJ, Inder WJ, Taylor AJ, Bogaert J, Macisaac AI, Heidbuchel H, Prior DL (2012a) Exercise-induced right ventricular dysfunction and structural remodelling in endurance athletes. Eur Heart J 33(8):998–1006. doi:10.1093/eurheartj/ehr397[pii]PubMedCrossRef La Gerche A, Burns AT, Mooney DJ, Inder WJ, Taylor AJ, Bogaert J, Macisaac AI, Heidbuchel H, Prior DL (2012a) Exercise-induced right ventricular dysfunction and structural remodelling in endurance athletes. Eur Heart J 33(8):998–1006. doi:10.​1093/​eurheartj/​ehr397[pii]PubMedCrossRef
go back to reference La Gerche A, Claessen G, Van De Bruaene A, Pattyn N, Van Cleemput J, Gewillig M, Bogaert J, Dymarkowski S, Claus P, Heidbuchel H (2012b) Cardiac magnetic resonance imaging: a new gold standard for ventricular volume quantification during high-intensity exercise. Circ Cardiovasc Imaging. doi:10.1161/CIRCIMAGING.112.980037 PubMed La Gerche A, Claessen G, Van De Bruaene A, Pattyn N, Van Cleemput J, Gewillig M, Bogaert J, Dymarkowski S, Claus P, Heidbuchel H (2012b) Cardiac magnetic resonance imaging: a new gold standard for ventricular volume quantification during high-intensity exercise. Circ Cardiovasc Imaging. doi:10.​1161/​CIRCIMAGING.​112.​980037 PubMed
go back to reference Ley S, Unterhinninghofen R, Ley-Zaporozhan J, Schenk JP, Kauczor HU, Szabo G (2008) Validation of magnetic resonance phase-contrast flow measurements in the main pulmonary artery and aorta using perivascular ultrasound in a large animal model. Invest Radiol 43(6):421–426. doi:10.1097/RLI.0b013e318169015d PubMedCrossRef Ley S, Unterhinninghofen R, Ley-Zaporozhan J, Schenk JP, Kauczor HU, Szabo G (2008) Validation of magnetic resonance phase-contrast flow measurements in the main pulmonary artery and aorta using perivascular ultrasound in a large animal model. Invest Radiol 43(6):421–426. doi:10.​1097/​RLI.​0b013e318169015d​ PubMedCrossRef
go back to reference Lotz J, Meier C, Leppert A, Galanski M (2002) Cardiovascular flow measurement with phase-contrast MR imaging: basic facts and implementation. Radiographics 22(3):651–671PubMedCrossRef Lotz J, Meier C, Leppert A, Galanski M (2002) Cardiovascular flow measurement with phase-contrast MR imaging: basic facts and implementation. Radiographics 22(3):651–671PubMedCrossRef
go back to reference Lurz P, Muthurangu V, Schievano S, Nordmeyer J, Bonhoeffer P, Taylor AM, Hansen MS (2009) Feasibility and reproducibility of biventricular volumetric assessment of cardiac function during exercise using real-time radial k-t SENSE magnetic resonance imaging. J Magn Reson Imaging 29(5):1062–1070. doi:10.1002/jmri.21762 PubMedCrossRef Lurz P, Muthurangu V, Schievano S, Nordmeyer J, Bonhoeffer P, Taylor AM, Hansen MS (2009) Feasibility and reproducibility of biventricular volumetric assessment of cardiac function during exercise using real-time radial k-t SENSE magnetic resonance imaging. J Magn Reson Imaging 29(5):1062–1070. doi:10.​1002/​jmri.​21762 PubMedCrossRef
go back to reference Parker JO, Thadani U (1979) Cardiac performance at rest and during exercise in normal subjects. Bull Eur Physiopathol Respir 15(5):935–949PubMed Parker JO, Thadani U (1979) Cardiac performance at rest and during exercise in normal subjects. Bull Eur Physiopathol Respir 15(5):935–949PubMed
go back to reference Pinsky MR (1984) Determinants of pulmonary arterial flow variation during respiration. J Appl Physiol 56(5):1237–1245PubMed Pinsky MR (1984) Determinants of pulmonary arterial flow variation during respiration. J Appl Physiol 56(5):1237–1245PubMed
go back to reference Poliner LR, Dehmer GJ, Lewis SE, Parkey RW, Blomqvist CG, Willerson JT (1980) Left ventricular performance in normal subjects: a comparison of the responses to exercise in the upright and supine positions. Circulation 62(3):528–534PubMedCrossRef Poliner LR, Dehmer GJ, Lewis SE, Parkey RW, Blomqvist CG, Willerson JT (1980) Left ventricular performance in normal subjects: a comparison of the responses to exercise in the upright and supine positions. Circulation 62(3):528–534PubMedCrossRef
go back to reference Steding-Ehrenborg K, Jablonowski R, Arvidsson PM, Carlsson M, Saltin B, Arheden H (2013) Moderate intensity supine exercise causes decreased cardiac volumes and increased outer volume variations: a cardiovascular magnetic resonance study. J Cardiovasc Magn Reson 15(1):96. doi:10.1186/1532-429X-15-96[pii]PubMedCrossRef Steding-Ehrenborg K, Jablonowski R, Arvidsson PM, Carlsson M, Saltin B, Arheden H (2013) Moderate intensity supine exercise causes decreased cardiac volumes and increased outer volume variations: a cardiovascular magnetic resonance study. J Cardiovasc Magn Reson 15(1):96. doi:10.​1186/​1532-429X-15-96[pii]PubMedCrossRef
go back to reference Steeden JA, Atkinson D, Taylor AM, Muthurangu V (2010) Assessing vascular response to exercise using a combination of real-time spiral phase contrast MR and noninvasive blood pressure measurements. J Magn Reson Imaging 31(4):997–1003. doi:10.1002/jmri.22105 PubMedCrossRef Steeden JA, Atkinson D, Taylor AM, Muthurangu V (2010) Assessing vascular response to exercise using a combination of real-time spiral phase contrast MR and noninvasive blood pressure measurements. J Magn Reson Imaging 31(4):997–1003. doi:10.​1002/​jmri.​22105 PubMedCrossRef
go back to reference Varaprasathan GA, Araoz PA, Higgins CB, Reddy GP (2002) Quantification of flow dynamics in congenital heart disease: applications of velocity-encoded cine MR imaging. Radiographics 22(4):895–905 discussion 905–896PubMedCrossRef Varaprasathan GA, Araoz PA, Higgins CB, Reddy GP (2002) Quantification of flow dynamics in congenital heart disease: applications of velocity-encoded cine MR imaging. Radiographics 22(4):895–905 discussion 905–896PubMedCrossRef
go back to reference Warburton DE, Haykowsky MJ, Quinney HA, Blackmore D, Teo KK, Humen DP (2002) Myocardial response to incremental exercise in endurance-trained athletes: influence of heart rate, contractility and the Frank-Starling effect. Exp Physiol 87(5):613–622PubMedCrossRef Warburton DE, Haykowsky MJ, Quinney HA, Blackmore D, Teo KK, Humen DP (2002) Myocardial response to incremental exercise in endurance-trained athletes: influence of heart rate, contractility and the Frank-Starling effect. Exp Physiol 87(5):613–622PubMedCrossRef
go back to reference Weber TF, von Tengg-Kobligk H, Kopp-Schneider A, Ley-Zaporozhan J, Kauczor HU, Ley S (2011) High-resolution phase-contrast MRI of aortic and pulmonary blood flow during rest and physical exercise using a MRI compatible bicycle ergometer. Eur J Radiol 80(1):103–108. doi:10.1016/j.ejrad.2010.06.045 PubMedCrossRef Weber TF, von Tengg-Kobligk H, Kopp-Schneider A, Ley-Zaporozhan J, Kauczor HU, Ley S (2011) High-resolution phase-contrast MRI of aortic and pulmonary blood flow during rest and physical exercise using a MRI compatible bicycle ergometer. Eur J Radiol 80(1):103–108. doi:10.​1016/​j.​ejrad.​2010.​06.​045 PubMedCrossRef
Metadata
Title
Adaptations of aortic and pulmonary artery flow parameters measured by phase-contrast magnetic resonance angiography during supine aerobic exercise
Authors
Guido E. Pieles
Gergely Szantho
Jonathan C. L. Rodrigues
Christopher B. Lawton
A. Graham Stuart
Chiara Bucciarelli-Ducci
Mark S. Turner
Craig A. Williams
Robert M. R. Tulloh
Mark C. K. Hamilton
Publication date
01-05-2014
Publisher
Springer Berlin Heidelberg
Published in
European Journal of Applied Physiology / Issue 5/2014
Print ISSN: 1439-6319
Electronic ISSN: 1439-6327
DOI
https://doi.org/10.1007/s00421-014-2833-x

Other articles of this Issue 5/2014

European Journal of Applied Physiology 5/2014 Go to the issue