Skip to main content
Top
Published in: Lasers in Medical Science 5/2018

01-07-2018 | Original Article

Adaptation and micro-structure of Co-Cr alloy maxillary complete denture base plates fabricated by selective laser melting technique

Authors: Ye Ye, Ting Jiao, Jiarui Zhu, Jian Sun

Published in: Lasers in Medical Science | Issue 5/2018

Login to get access

Abstract

The purpose of the study was to evaluate the adaptation and micro-structure of Co-Cr alloy maxillary complete denture base plates fabricated by the selective laser melting (SLM) technique. Twenty pairs of edentulous casts were randomly and evenly divided into two groups, and manufacturing of the Co-Cr alloy maxillary complete denture base was conducted either by the SLM technique or by the conventional method. The base-cast sets were transversally sectioned into three sections at the distal canines, mesial of the first molars and the posterior palatal zone. The gap between the metal base and cast was measured in these three sections with a stereoscopic microscope, and the data were analysed using t tests. A total of five specimens of 5 mm diameter were fabricated with the Co-Cr alloy by SLM and the traditional casting technology. A scanning electron microscope (SEM) was used to evaluate the differences in microstructure between these specimens. There was no statistical difference between the three sections in all four groups (P > 0.05). At the region of the canines, the clearance value for the SLM Co-Cr alloy group was larger than that of the conventional method group (P < 0.05). At the mesial of the first molar region and the posterior palatal zone, there was no statistical difference between the gaps observed in the two groups (P > 0.05). The SLM Co-Cr alloy has a denser microstructure behaviour and less casting defect than the cast Co-Cr alloy. The SLM technique showed initial feasibility for the manufacture of dental bases of complete dentures, but large sample studies are needed to prove its reliability in clinical applications. The mechanical properties and microstructure of the denture frameworks prepared by selective laser melting indicate that these dentures are appropriate for clinical use.
Literature
1.
go back to reference Sun J, Zhang F (2012) The application of rapid prototyping in prosthodontics. J Prosthodont 21:641–644CrossRefPubMed Sun J, Zhang F (2012) The application of rapid prototyping in prosthodontics. J Prosthodont 21:641–644CrossRefPubMed
2.
go back to reference Bibb R, Brown R (2000) The application of computer aided product development techniques in medical modelling. Biomed Sci Instrum 36:319–324PubMed Bibb R, Brown R (2000) The application of computer aided product development techniques in medical modelling. Biomed Sci Instrum 36:319–324PubMed
3.
go back to reference Alghazzawi TF, Lemons J, Liu PR et al (2012) The failure load of CAD/CAM generated zirconia and glass-ceramic laminate veneers with different preparation designs[J]. J Prosthet Dent 108(6):386–393CrossRefPubMed Alghazzawi TF, Lemons J, Liu PR et al (2012) The failure load of CAD/CAM generated zirconia and glass-ceramic laminate veneers with different preparation designs[J]. J Prosthet Dent 108(6):386–393CrossRefPubMed
4.
go back to reference Castillo-Oyague R, Osorio R, Osorio E et al (2012) The effect of surface treatments on the microroughness of laser-sintered and vacuum-cast base metal alloys for dental prosthetic frameworks. Microsc Res Tech 75:1206–1212CrossRefPubMed Castillo-Oyague R, Osorio R, Osorio E et al (2012) The effect of surface treatments on the microroughness of laser-sintered and vacuum-cast base metal alloys for dental prosthetic frameworks. Microsc Res Tech 75:1206–1212CrossRefPubMed
6.
go back to reference Castillo-de-Oyague R, Sanchez-Turrion A, Lopez-Lozano JF et al (2012) Vertical misfit of laser-sintered and vacuum-cast implant-supported crown copings luted with definitive and temporary luting agents. Med Oral Patol Oral Cir Bucal 17:e610–e617CrossRefPubMedPubMedCentral Castillo-de-Oyague R, Sanchez-Turrion A, Lopez-Lozano JF et al (2012) Vertical misfit of laser-sintered and vacuum-cast implant-supported crown copings luted with definitive and temporary luting agents. Med Oral Patol Oral Cir Bucal 17:e610–e617CrossRefPubMedPubMedCentral
7.
go back to reference Williams RJ, Bibb R, Eggbeer D et al (2006) Use of CAD/CAM technology to fabricate a removable partial denture framework[J]. J Prosthet Dent 96(2):96–99CrossRefPubMed Williams RJ, Bibb R, Eggbeer D et al (2006) Use of CAD/CAM technology to fabricate a removable partial denture framework[J]. J Prosthet Dent 96(2):96–99CrossRefPubMed
8.
go back to reference Wu J, Gao B, Tan H et al (2010) A feasibility study on laser rapid forming of a complete titanium denture base plate[J]. Lasers Med Sci 25(3):309–315CrossRefPubMed Wu J, Gao B, Tan H et al (2010) A feasibility study on laser rapid forming of a complete titanium denture base plate[J]. Lasers Med Sci 25(3):309–315CrossRefPubMed
9.
go back to reference Consani RLX, Iwasaki RY et al (2008) Effect of repeated simulated disinfections by microwave energy on the complete denture base adaptation. Open Dent J 2:61–66CrossRefPubMedPubMedCentral Consani RLX, Iwasaki RY et al (2008) Effect of repeated simulated disinfections by microwave energy on the complete denture base adaptation. Open Dent J 2:61–66CrossRefPubMedPubMedCentral
10.
go back to reference Inokoshi M, Kanazawa M, Minakuchi S (2012) Evaluation of a complete denture trial method applying rapid prototyping[J]. Dent Mater J 31(1):40CrossRefPubMed Inokoshi M, Kanazawa M, Minakuchi S (2012) Evaluation of a complete denture trial method applying rapid prototyping[J]. Dent Mater J 31(1):40CrossRefPubMed
11.
go back to reference Kanazawa M, Iwaki M, Minakuchi S et al (2014) Fabrication of titanium alloy frameworks for complete dentures by selective laser melting[J]. J Prosthet Dent 112(6):1441–17.9CrossRefPubMed Kanazawa M, Iwaki M, Minakuchi S et al (2014) Fabrication of titanium alloy frameworks for complete dentures by selective laser melting[J]. J Prosthet Dent 112(6):1441–17.9CrossRefPubMed
12.
go back to reference Ye Y, Xiong Y Y, Zhu J R, et al. (2017) [comparison of adaptation and microstructure of titanium upper complete denture base fabricated by selecting laser melting and electron beam melting][J]. Zhonghua Kou Qiang Yi Xue Za Zhi, 52(6):346–350 Ye Y, Xiong Y Y, Zhu J R, et al. (2017) [comparison of adaptation and microstructure of titanium upper complete denture base fabricated by selecting laser melting and electron beam melting][J]. Zhonghua Kou Qiang Yi Xue Za Zhi, 52(6):346–350
13.
go back to reference Koutsoukis T, Zinelis S, Eliades G et al (2015) Selective laser melting technique of co-Cr dental alloys: a review of structure and properties and comparative analysis with other available techniques.[J]. J Prosthodont 24(4):303CrossRefPubMed Koutsoukis T, Zinelis S, Eliades G et al (2015) Selective laser melting technique of co-Cr dental alloys: a review of structure and properties and comparative analysis with other available techniques.[J]. J Prosthodont 24(4):303CrossRefPubMed
14.
go back to reference Williams RJ, Bibb R, Rafik T (2004) A technique for fabricating patterns for removable partial denture frameworks using digitized casts and electronic surveying[J]. J Prosthet Dent 91(1):85–88CrossRefPubMed Williams RJ, Bibb R, Rafik T (2004) A technique for fabricating patterns for removable partial denture frameworks using digitized casts and electronic surveying[J]. J Prosthet Dent 91(1):85–88CrossRefPubMed
15.
go back to reference Peyton FA, Anthony DH (1963) Evaluation of dentures processed by different techniques. J Prosthet Dent 13:269–282CrossRef Peyton FA, Anthony DH (1963) Evaluation of dentures processed by different techniques. J Prosthet Dent 13:269–282CrossRef
16.
go back to reference Hasegawa K (1976) The adaptability of cast metal denture[J]. Nihon Hotetsu Shika Gakkai Zasshi 20(3):423–447CrossRef Hasegawa K (1976) The adaptability of cast metal denture[J]. Nihon Hotetsu Shika Gakkai Zasshi 20(3):423–447CrossRef
17.
go back to reference Yamada T (1979) Basic studies on the adaptation of cast metal denture plate[J]. Nihon Hotetsu Shika Gakkai Zasshi 23(2):288–309CrossRef Yamada T (1979) Basic studies on the adaptation of cast metal denture plate[J]. Nihon Hotetsu Shika Gakkai Zasshi 23(2):288–309CrossRef
18.
go back to reference Kishi M (1972) Experimental studies on the relation between area and displacement of loading surfaces in connection with displaceability in the mucosa of edentulous alveolar ridge under pressure. Shikwa Gakuho 72:1043–1071 Kishi M (1972) Experimental studies on the relation between area and displacement of loading surfaces in connection with displaceability in the mucosa of edentulous alveolar ridge under pressure. Shikwa Gakuho 72:1043–1071
20.
go back to reference Kruth JP, Mercelis P, Van Vaerenbergh J et al (2005) Binding mechanisms in selective laser sintering and selective laser melting. Rapid Prototyping J 11:26–36CrossRef Kruth JP, Mercelis P, Van Vaerenbergh J et al (2005) Binding mechanisms in selective laser sintering and selective laser melting. Rapid Prototyping J 11:26–36CrossRef
21.
go back to reference Takaichi A, Suyalatu, Nakamoto T, Joko N, Nomura N, Tsutsumi Y et al (2013) Microstructures and mechanical properties of co-29Cr-6Mo alloy fabricated by selective laser melting process for dental applications[J]. J Mech Biomed Mater 21(1):67–76CrossRef Takaichi A, Suyalatu, Nakamoto T, Joko N, Nomura N, Tsutsumi Y et al (2013) Microstructures and mechanical properties of co-29Cr-6Mo alloy fabricated by selective laser melting process for dental applications[J]. J Mech Biomed Mater 21(1):67–76CrossRef
22.
go back to reference Ucar Y, Akova T, Akyil MS et al (2009) Internal fit evaluation of crowns prepared using a new dental crown fabrication technique: laser-sintered co-Cr crowns. J Prosthet Dent 102:253–259CrossRefPubMed Ucar Y, Akova T, Akyil MS et al (2009) Internal fit evaluation of crowns prepared using a new dental crown fabrication technique: laser-sintered co-Cr crowns. J Prosthet Dent 102:253–259CrossRefPubMed
23.
go back to reference Tara MA, Eschbach S, Bohlsen F et al (2011) Clinical outcome of metal-ceramic crowns fabricated with laser-sintering technology. Int J Prosthodont 24:46–48PubMed Tara MA, Eschbach S, Bohlsen F et al (2011) Clinical outcome of metal-ceramic crowns fabricated with laser-sintering technology. Int J Prosthodont 24:46–48PubMed
24.
go back to reference Akova T, Ucar Y, Tukay A et al (2008) Comparison of the bond strength of laser-sintered and cast base metal dental alloys to porcelain. Dent Mater 24:1400–1404CrossRefPubMed Akova T, Ucar Y, Tukay A et al (2008) Comparison of the bond strength of laser-sintered and cast base metal dental alloys to porcelain. Dent Mater 24:1400–1404CrossRefPubMed
25.
go back to reference Yadroitsev I, Krakhmalev P, Yadroitsava I (2014) Selective laser melting of Ti6Al4V alloy for biomedical applications: temperature monitoring and microstructural evolution[J]. J Alloys Compd 583:404–409CrossRef Yadroitsev I, Krakhmalev P, Yadroitsava I (2014) Selective laser melting of Ti6Al4V alloy for biomedical applications: temperature monitoring and microstructural evolution[J]. J Alloys Compd 583:404–409CrossRef
26.
go back to reference Xin XZ, Chen J, Xiang N, Wei B (2013) Surface properties and corrosion behavior of co-Cr alloy fabricated with selective laser melting technique[J]. Cell Biochem Biophys 67:983–990CrossRefPubMed Xin XZ, Chen J, Xiang N, Wei B (2013) Surface properties and corrosion behavior of co-Cr alloy fabricated with selective laser melting technique[J]. Cell Biochem Biophys 67:983–990CrossRefPubMed
Metadata
Title
Adaptation and micro-structure of Co-Cr alloy maxillary complete denture base plates fabricated by selective laser melting technique
Authors
Ye Ye
Ting Jiao
Jiarui Zhu
Jian Sun
Publication date
01-07-2018
Publisher
Springer London
Published in
Lasers in Medical Science / Issue 5/2018
Print ISSN: 0268-8921
Electronic ISSN: 1435-604X
DOI
https://doi.org/10.1007/s10103-018-2438-4

Other articles of this Issue 5/2018

Lasers in Medical Science 5/2018 Go to the issue