Abstract

Background

Several studies have reported that the transverse acetabular ligament (TAL) can be used to orient the acetabular component during total hip arthroplasty and that it can be identified in nearly all patients.

Questions/purposes

We attempted to determine how often the TAL could be identified during primary THA and its accuracy as a guide for acetabular component positioning.

Methods

In a prospective series of 63 patients (64 hips) undergoing primary THA, two surgeons attempted to identify the TAL and, if it was found, to use it for acetabular component orientation. Patients in whom the TAL was identified served as the study group and the ligament was used for cup orientation in those patients; the remaining patients in whom the ligament could not be identified served as a control group and had free-hand cup positioning. Anteversion was determined by radiographic measurement from true lateral views.

Results

The TAL was identified in only 30 hips (47%) and was more likely to be found in patients who did not have inferior acetabular osteophytes. Acetabular position was not improved using this ligament for reference.

Conclusions

The TAL could not be routinely identified at surgery and when used for cup orientation it was no more accurate for cup positioning than free-hand technique.
Literature
1.
go back to reference Archbold HA, Mockford B, Molloy D, McConway J, Ogonda L, Beverland D. The transverse acetabular ligament: an aid to orientation of the acetabular component during primary total hip replacement: a preliminary study of 1000 cases investigating postoperative stability. J Bone Joint Surg Br. 2006;88:883–886.CrossRefPubMed Archbold HA, Mockford B, Molloy D, McConway J, Ogonda L, Beverland D. The transverse acetabular ligament: an aid to orientation of the acetabular component during primary total hip replacement: a preliminary study of 1000 cases investigating postoperative stability. J Bone Joint Surg Br. 2006;88:883–886.CrossRefPubMed
2.
go back to reference Archbold HA, Slomczykowski M, Crone M, Eckman K, Jaramaz B, Beverland DE. The relationship of the orientation of the transverse acetabular ligament and acetabular labrum to the suggested safe zones of cup positioning in total hip arthroplasty. Hip Int. 2008;18:1–6.PubMed Archbold HA, Slomczykowski M, Crone M, Eckman K, Jaramaz B, Beverland DE. The relationship of the orientation of the transverse acetabular ligament and acetabular labrum to the suggested safe zones of cup positioning in total hip arthroplasty. Hip Int. 2008;18:1–6.PubMed
3.
go back to reference Biedermann R, Tonin A, Krismer M, Rachbauer F, Eibl G, Stöckl B. Reducing the risk of dislocation after total hip arthroplasty: the effect of orientation of the acetabular component. J Bone Joint Surg Br. 2005;87:762–769.CrossRefPubMed Biedermann R, Tonin A, Krismer M, Rachbauer F, Eibl G, Stöckl B. Reducing the risk of dislocation after total hip arthroplasty: the effect of orientation of the acetabular component. J Bone Joint Surg Br. 2005;87:762–769.CrossRefPubMed
4.
go back to reference Coventry MB, Beckenbaugh RD, Nolan DR, Ilstrup DM. 2,012 total hip arthroplasties: a study of postoperative course and early complications. J Bone Joint Surg Am. 1974;56:273–284.PubMed Coventry MB, Beckenbaugh RD, Nolan DR, Ilstrup DM. 2,012 total hip arthroplasties: a study of postoperative course and early complications. J Bone Joint Surg Am. 1974;56:273–284.PubMed
5.
go back to reference Devane PA, Horne JG, Martin K, Coldham G, Krause B. Three-dimensional polyethylene wear of a press-fit titanium prosthesis: factors influencing generation of polyethylene debris. J Arthroplasty. 1997;12:256–266.CrossRefPubMed Devane PA, Horne JG, Martin K, Coldham G, Krause B. Three-dimensional polyethylene wear of a press-fit titanium prosthesis: factors influencing generation of polyethylene debris. J Arthroplasty. 1997;12:256–266.CrossRefPubMed
6.
go back to reference Fackler CD, Poss R. Dislocation in total hip arthroplasties. Clin Orthop Relat Res. 1980;151:169–178.PubMed Fackler CD, Poss R. Dislocation in total hip arthroplasties. Clin Orthop Relat Res. 1980;151:169–178.PubMed
7.
go back to reference Hedlunch U, Fredin H. Patient characteristics in dislocations after primary total hip arthroplasty: 60 patients compared with a control group. Acta Orthop Scand. 1995;66:225–228.CrossRef Hedlunch U, Fredin H. Patient characteristics in dislocations after primary total hip arthroplasty: 60 patients compared with a control group. Acta Orthop Scand. 1995;66:225–228.CrossRef
8.
go back to reference Kennedy JG, Rogers WB, Soffe KE, Sullivan RJ, Griffen DG, Sheehan LJ. Effect of acetabular component orientation on recurrent dislocation, pelvic osteolysis, polyethylene wear, and component migration. J Arthroplasty. 1998;13:530–534.CrossRefPubMed Kennedy JG, Rogers WB, Soffe KE, Sullivan RJ, Griffen DG, Sheehan LJ. Effect of acetabular component orientation on recurrent dislocation, pelvic osteolysis, polyethylene wear, and component migration. J Arthroplasty. 1998;13:530–534.CrossRefPubMed
9.
go back to reference Lewinnek GE, Lewis JL, Tarr R, Compere CL, Zimmerman JR. Dislocations after total hip-replacement arthroplasties. J Bone Joint Surg Am. 1978;60:217–220.PubMed Lewinnek GE, Lewis JL, Tarr R, Compere CL, Zimmerman JR. Dislocations after total hip-replacement arthroplasties. J Bone Joint Surg Am. 1978;60:217–220.PubMed
10.
go back to reference Patil S, Bergula A, Chen PC, Colwell CW Jr, D’Lima DD. Polyethylene wear and acetabular component orientation. J Bone Joint Surg Am. 2003;85(Suppl 4):56–63.PubMed Patil S, Bergula A, Chen PC, Colwell CW Jr, D’Lima DD. Polyethylene wear and acetabular component orientation. J Bone Joint Surg Am. 2003;85(Suppl 4):56–63.PubMed
11.
go back to reference Pearce CJ, Sexton SA, Davies DC, Khaleel A. The transverse acetabular ligament may be used to align the acetabular cup in total hip arthroplasty. Hip Int. 2008;18:7–10.PubMed Pearce CJ, Sexton SA, Davies DC, Khaleel A. The transverse acetabular ligament may be used to align the acetabular cup in total hip arthroplasty. Hip Int. 2008;18:7–10.PubMed
12.
go back to reference Woo RY, Morrey BF. Dislocation after total hip arthroplasty. J Bone Joint Surg Am. 1982;64:1295–1306.PubMed Woo RY, Morrey BF. Dislocation after total hip arthroplasty. J Bone Joint Surg Am. 1982;64:1295–1306.PubMed
Metadata
Title
Acetabular Component Positioning Using the Transverse Acetabular Ligament: Can You Find It and Does It Help?
Authors
Noah J. Epstein, MD
Steven T. Woolson, MD
Nicholas J. Giori, MD
Publication date
01-02-2011
Publisher
Springer-Verlag
Published in
Clinical Orthopaedics and Related Research® / Issue 2/2011
Print ISSN: 0009-921X
Electronic ISSN: 1528-1132
DOI
https://doi.org/10.1007/s11999-010-1523-1

Other articles of this Issue 2/2011

Clinical Orthopaedics and Related Research® 2/2011 Go to the issue

Symposium: Papers Presented at the Hip Society Meetings

High Complication Rate With Anterior Total Hip Arthroplasties on a Fracture Table