Accuracy of an Automatic Patient-Positioning System Based on the Correlation of Two Edge Images in Radiotherapy

Authors: Myonggeun Yoon, Minho Cheong, Jinsung Kim, Dong Ho Shin, Sung Yong Park, Se Byeong Lee

Published in: Journal of Imaging Informatics in Medicine | Issue 2/2011

Login to get access

Abstract

We have clinically evaluated the accuracy of an automatic patient-positioning system based on the image correlation of two edge images in radiotherapy. Ninety-six head & neck images from eight patients undergoing proton therapy were compared with a digitally reconstructed radiograph (DRR) of planning CT. Two edge images, a reference image and a test image, were extracted by applying a Canny edge detector algorithm to a DRR and a 2D X-ray image, respectively, of each patient before positioning. In a simulation using a humanoid phantom, performed to verify the effectiveness of the proposed method, no registration errors were observed for given ranges of rotation, pitch, and translation in the x, y, and z directions. For real patients, however, there were discrepancies between the automatic positioning method and manual positioning by physicians or technicians. Using edged head coronal- and sagittal-view images, the average differences in registration between these two methods for the x, y, and z directions were 0.11 cm, 0.09 cm and 0.11 cm, respectively, whereas the maximum discrepancies were 0.34 cm, 0.38 cm, and 0.50 cm, respectively. For rotation and pitch, the average registration errors were 0.95° and 1.00°, respectively, and the maximum errors were 3.6° and 2.3°, respectively. The proposed automatic patient-positioning system based on edge image comparison was relatively accurate for head and neck patients. However, image deformation during treatment may render the automatic method less accurate, since the test image many differ significantly from the reference image.
Literature
1.
go back to reference Langer M, Leong J: Optimization of beam weights under dose–volume restrictions. Int J Radiat Oncol Biol Phys 13:1255–1260, 1987PubMedCrossRef Langer M, Leong J: Optimization of beam weights under dose–volume restrictions. Int J Radiat Oncol Biol Phys 13:1255–1260, 1987PubMedCrossRef
2.
go back to reference Miften MM, Das SK, Su M, Marks LB: A dose–volume-based tool for evaluating and ranking IMRT treatment plans. J Appl Clin Med Phys 5:1–14, 2004PubMedCrossRef Miften MM, Das SK, Su M, Marks LB: A dose–volume-based tool for evaluating and ranking IMRT treatment plans. J Appl Clin Med Phys 5:1–14, 2004PubMedCrossRef
3.
go back to reference Morill SM, Lane RG, Wong JA, Rosen II: Dose–volume considerations with linear programming optimization. Med Phys 18:1201–1210, 1991PubMedCrossRef Morill SM, Lane RG, Wong JA, Rosen II: Dose–volume considerations with linear programming optimization. Med Phys 18:1201–1210, 1991PubMedCrossRef
4.
go back to reference Lips IM, van der Heide UA, Kotte AN, van Vulpen M, Bel A: Effect of translational and rotational errors on complex dose distributions with off-line and on-line position verification. Int J Radiat Oncol Biol Phys 74:1600–1608, 2009PubMedCrossRef Lips IM, van der Heide UA, Kotte AN, van Vulpen M, Bel A: Effect of translational and rotational errors on complex dose distributions with off-line and on-line position verification. Int J Radiat Oncol Biol Phys 74:1600–1608, 2009PubMedCrossRef
5.
go back to reference Engelsman M, Kooy HM: Target volume dose considerations in proton beam treatment planning for lung tumors. Med Phys 32:3549–3557, 2005PubMedCrossRef Engelsman M, Kooy HM: Target volume dose considerations in proton beam treatment planning for lung tumors. Med Phys 32:3549–3557, 2005PubMedCrossRef
6.
go back to reference Uríe M, Goítein M, Wagner M: Compensating for heterogeneities in proton radiation therapy. Phys Med Biol 29:553–566, 1984PubMedCrossRef Uríe M, Goítein M, Wagner M: Compensating for heterogeneities in proton radiation therapy. Phys Med Biol 29:553–566, 1984PubMedCrossRef
7.
go back to reference Rabinowitz I, Broomberg J, Goitein M, McCarthy K, Leong J: Accuracy of radiation field alignment in clinical practice. Int J Radiat Oncol Biol Phys 11:1857–1867, 1985PubMedCrossRef Rabinowitz I, Broomberg J, Goitein M, McCarthy K, Leong J: Accuracy of radiation field alignment in clinical practice. Int J Radiat Oncol Biol Phys 11:1857–1867, 1985PubMedCrossRef
8.
go back to reference Leszczynski KW, Loose S, Boyko S: An image registration scheme applied to verification of radiation therapy. Br J Radiol 71:413–426, 1998PubMed Leszczynski KW, Loose S, Boyko S: An image registration scheme applied to verification of radiation therapy. Br J Radiol 71:413–426, 1998PubMed
9.
go back to reference Girouard LM, Pouliot J, Maldague X, Zaccarin A: Automatic setup deviation measurements with electronic portal images for pelvic fields. Med Phys 25:1180–1185, 1998PubMedCrossRef Girouard LM, Pouliot J, Maldague X, Zaccarin A: Automatic setup deviation measurements with electronic portal images for pelvic fields. Med Phys 25:1180–1185, 1998PubMedCrossRef
10.
go back to reference Eilertsen K, Skretting A, Tennvassås T: Methods for fully automated verification of patient set-up in external beam radiotherapy with polygon shaped fields. Phys Med Biol 39:993–1012, 1994PubMedCrossRef Eilertsen K, Skretting A, Tennvassås T: Methods for fully automated verification of patient set-up in external beam radiotherapy with polygon shaped fields. Phys Med Biol 39:993–1012, 1994PubMedCrossRef
11.
go back to reference Kim J, Fessler JA, Lam KL, Balter JM, Ten Haken RK: A feasibility study of mutual information based setup error estimation for radiotherapy. Med Phys 28:2507–2517, 2001PubMedCrossRef Kim J, Fessler JA, Lam KL, Balter JM, Ten Haken RK: A feasibility study of mutual information based setup error estimation for radiotherapy. Med Phys 28:2507–2517, 2001PubMedCrossRef
12.
go back to reference Plattard D, Soret M, Troccaz J, et al: Patient set-up using portal images: 2D/2D image registration using mutual information. Comput Aided Surg 5:246–262, 2000PubMedCrossRef Plattard D, Soret M, Troccaz J, et al: Patient set-up using portal images: 2D/2D image registration using mutual information. Comput Aided Surg 5:246–262, 2000PubMedCrossRef
13.
go back to reference Radcliffe T, Rajapakshe R, Shalev S: Pseudocorrelation: a fast, robust, absolute, gray-level image alignment algorithm. Med Phys 21:761–769, 1994PubMedCrossRef Radcliffe T, Rajapakshe R, Shalev S: Pseudocorrelation: a fast, robust, absolute, gray-level image alignment algorithm. Med Phys 21:761–769, 1994PubMedCrossRef
14.
go back to reference Jones SM, Boyer AL: Investigation of an FFT-based correlation technique for verification of radiation treatment setup. Med Phys 18:1116–1125, 1991PubMedCrossRef Jones SM, Boyer AL: Investigation of an FFT-based correlation technique for verification of radiation treatment setup. Med Phys 18:1116–1125, 1991PubMedCrossRef
15.
go back to reference Dong L, Boyer AL: An image correlation procedure for digitally reconstructed radiographs and electronic portal images. Int J Radiat Oncol Biol Phys 33:1053–1060, 1996 Dong L, Boyer AL: An image correlation procedure for digitally reconstructed radiographs and electronic portal images. Int J Radiat Oncol Biol Phys 33:1053–1060, 1996
16.
go back to reference Petrascu O, Bel A, Linthout N, Verellen D, Soete G, Storme G: Automatic on-line electronic portal image analysis with a wavelet-based edge detector. Med Phys 27:321–329, 2000PubMedCrossRef Petrascu O, Bel A, Linthout N, Verellen D, Soete G, Storme G: Automatic on-line electronic portal image analysis with a wavelet-based edge detector. Med Phys 27:321–329, 2000PubMedCrossRef
17.
go back to reference Sawada A, Yoda K, Numano M, et al: Patient positioning method based on binary image correlation between two edge images for proton-beam radiation therapy. Med Phys 32:3106–3111, 2005PubMedCrossRef Sawada A, Yoda K, Numano M, et al: Patient positioning method based on binary image correlation between two edge images for proton-beam radiation therapy. Med Phys 32:3106–3111, 2005PubMedCrossRef
18.
go back to reference Stern D, Kurz L: Edge detection in correlated noise using Latin squares models. Pattern Recogn 21:119–129, 1988CrossRef Stern D, Kurz L: Edge detection in correlated noise using Latin squares models. Pattern Recogn 21:119–129, 1988CrossRef
19.
go back to reference Haberstroh J, Kurz L: Line detection in noisy and structured background using Graco-Latin squares, CVGIP. Graph Models Image Proc 55:161–179, 1993 Haberstroh J, Kurz L: Line detection in noisy and structured background using Graco-Latin squares, CVGIP. Graph Models Image Proc 55:161–179, 1993
20.
go back to reference Nahi N, Assefi T: Bayesian recursive image estimation. IEEE Trans Comput 7:734–738, 1972 Nahi N, Assefi T: Bayesian recursive image estimation. IEEE Trans Comput 7:734–738, 1972
21.
go back to reference Prewitt J: Object enhancement and extraction. In: Lipkin BS, Rosenfeld A Eds. Picture Processing and Psychopictorics. New York: Academic, 1970 Prewitt J: Object enhancement and extraction. In: Lipkin BS, Rosenfeld A Eds. Picture Processing and Psychopictorics. New York: Academic, 1970
22.
go back to reference Kirsh R: Computer determination of the constituent structure of biological images. Comput Biomed Res 4:314–328, 1971 Kirsh R: Computer determination of the constituent structure of biological images. Comput Biomed Res 4:314–328, 1971
23.
24.
go back to reference Haralick R: Digital step edges from zero crossing second directional derivatives. IEEE Trans Pattern Anal Mach Intell PAMI 58–68, 1984 Haralick R: Digital step edges from zero crossing second directional derivatives. IEEE Trans Pattern Anal Mach Intell PAMI 58–68, 1984
25.
go back to reference Huechel M: An operator which locates edges in digitized pictures. J Assoc Comput Mach 18:113–125, 1971 Huechel M: An operator which locates edges in digitized pictures. J Assoc Comput Mach 18:113–125, 1971
26.
go back to reference Canny J: A computational approach to edge detection. IEEE Trans Pattern Anal Mach Intell 8:679–698, 1986CrossRef Canny J: A computational approach to edge detection. IEEE Trans Pattern Anal Mach Intell 8:679–698, 1986CrossRef
Metadata
Title
Accuracy of an Automatic Patient-Positioning System Based on the Correlation of Two Edge Images in Radiotherapy
Authors
Myonggeun Yoon
Minho Cheong
Jinsung Kim
Dong Ho Shin
Sung Yong Park
Se Byeong Lee
Publication date
01-04-2011
Publisher
Springer-Verlag
Published in
Journal of Imaging Informatics in Medicine / Issue 2/2011
Print ISSN: 2948-2925
Electronic ISSN: 2948-2933
DOI
https://doi.org/10.1007/s10278-009-9269-6

Other articles of this Issue 2/2011

Journal of Digital Imaging 2/2011 Go to the issue