Skip to main content
Top

17-05-2024 | Cataract | Cataract

Accuracy of 10 MHz ultrasonography for evaluation of posterior lens capsule in traumatic cataract

Authors: Xixuan Ke, Cuilian Li, Liyu Lin, Yuqiang Huang, Honghe Xia, Chuang Jin, Tingkun Shi, Qi Zhang, Xulong Liao, Haoyu Chen

Published in: Graefe's Archive for Clinical and Experimental Ophthalmology

Login to get access

Abstract

Purpose

To investigate the performance of 10 MHz ultrasonography in detecting posterior lens capsule defects before traumatic cataract surgery.

Methods

This retrospective analysis includes patients with traumatic cataracts who underwent cataract surgery. Preoperative 10 MHz ultrasonography was performed to evaluate whether the posterior lens capsule was defective or intact, and the results were compared to the intraoperative findings. Sensitivity, specificity, positive predictive value, negative predictive value, accuracy, and kappa were calculated.

Results

The study included 140 eyes of 140 patients. There were 68 eyes with closed-globe injuries and 72 eyes with open-globe injuries. The sensitivity, specificity, positive predictive value, negative predictive value, accuracy, and kappa of 10 MHz ultrasonography was 86.76%, 90.28%, 89.39%, 87.84%, 88.57% and 0.771, respectively. The accuracy was 86.11% and 91.18% in open-globe and closed-globe injury groups, respectively.

Conclusion

The accuracy of 10 MHz ultrasonography in evaluating the posterior lens capsule in traumatic cataracts is high. Preoperative 10 MHz ultrasonography would help to make an appropriate surgical plan.
Literature
1.
2.
go back to reference Tabatabaei A, Kiarudi MY, Ghassemi F et al (2012) Evaluation of posterior lens capsule by 20-MHz ultrasound probe in traumatic cataract. Am J Ophthalmol 153:51–54CrossRefPubMed Tabatabaei A, Kiarudi MY, Ghassemi F et al (2012) Evaluation of posterior lens capsule by 20-MHz ultrasound probe in traumatic cataract. Am J Ophthalmol 153:51–54CrossRefPubMed
3.
go back to reference Tabatabaei A, Hasanlou N, Kheirkhah A et al (2014) Accuracy of 3 imaging modalities for evaluation of the posterior lens capsule in traumatic cataract. J Cataract Refract Surg 40:1092–1096CrossRefPubMed Tabatabaei A, Hasanlou N, Kheirkhah A et al (2014) Accuracy of 3 imaging modalities for evaluation of the posterior lens capsule in traumatic cataract. J Cataract Refract Surg 40:1092–1096CrossRefPubMed
4.
go back to reference Tabatabaei SA, Soleimani M, Etesali H et al (2020) Accuracy of swept-source optical coherence tomography and ultrasound biomicroscopy for evaluation of posterior lens capsule in traumatic cataract. Am J Ophthalmol 216:55–58CrossRefPubMed Tabatabaei SA, Soleimani M, Etesali H et al (2020) Accuracy of swept-source optical coherence tomography and ultrasound biomicroscopy for evaluation of posterior lens capsule in traumatic cataract. Am J Ophthalmol 216:55–58CrossRefPubMed
5.
go back to reference Nguyen TN, Mansour M, Deschenes J et al (2003) Visualization of posterior lens capsule integrity by 20-MHz ultrasound probe in ocular trauma. Am J Ophthalmol 136:754–755CrossRefPubMed Nguyen TN, Mansour M, Deschenes J et al (2003) Visualization of posterior lens capsule integrity by 20-MHz ultrasound probe in ocular trauma. Am J Ophthalmol 136:754–755CrossRefPubMed
6.
go back to reference Wu B, Li Q, Liu Y et al (2019) Application of 14-MHz ultrasonography with tissue harmonic imaging to determine posterior capsule integrity in traumatic cataract. Journal of ophthalmology 2019:4903703CrossRefPubMedPubMedCentral Wu B, Li Q, Liu Y et al (2019) Application of 14-MHz ultrasonography with tissue harmonic imaging to determine posterior capsule integrity in traumatic cataract. Journal of ophthalmology 2019:4903703CrossRefPubMedPubMedCentral
7.
go back to reference Perry LJ (2012) The evaluation of patients with traumatic cataracts by ultrasound technologies. Semin Ophthalmol 27:121–124CrossRefPubMed Perry LJ (2012) The evaluation of patients with traumatic cataracts by ultrasound technologies. Semin Ophthalmol 27:121–124CrossRefPubMed
8.
go back to reference Wu B, Yuan X, Chen S (2021) Comperative analysis of accuracy between low-frequency ultrasound biomicroscopy and 14-MHz ultrasonography with tissue harmonic imaging for the evaluation of the posterior lens capsule in traumatic cataracts. BMC Ophthalmol 21:375CrossRefPubMedPubMedCentral Wu B, Yuan X, Chen S (2021) Comperative analysis of accuracy between low-frequency ultrasound biomicroscopy and 14-MHz ultrasonography with tissue harmonic imaging for the evaluation of the posterior lens capsule in traumatic cataracts. BMC Ophthalmol 21:375CrossRefPubMedPubMedCentral
9.
go back to reference Hewick SA, Fairhead AC, Culy JC et al (2004) A comparison of 10 MHz and 20 MHz ultrasound probes in imaging the eye and orbit. Br J Ophthalmol 88:551–555CrossRefPubMedPubMedCentral Hewick SA, Fairhead AC, Culy JC et al (2004) A comparison of 10 MHz and 20 MHz ultrasound probes in imaging the eye and orbit. Br J Ophthalmol 88:551–555CrossRefPubMedPubMedCentral
10.
go back to reference Sen P, Kumar N, Mohan A et al (2021) Role of Scheimpflug imaging for assessment of posterior lens capsule in pediatric traumatic cataract. Indian J Ophthalmol 69:3520–3524CrossRefPubMedPubMedCentral Sen P, Kumar N, Mohan A et al (2021) Role of Scheimpflug imaging for assessment of posterior lens capsule in pediatric traumatic cataract. Indian J Ophthalmol 69:3520–3524CrossRefPubMedPubMedCentral
11.
go back to reference Grewal DS, Jain R, Brar GS et al (2008) Posterior capsule rupture following closed globe injury: Scheimpflug imaging, pathogenesis, and management. Eur J Ophthalmol 18:453–455CrossRefPubMed Grewal DS, Jain R, Brar GS et al (2008) Posterior capsule rupture following closed globe injury: Scheimpflug imaging, pathogenesis, and management. Eur J Ophthalmol 18:453–455CrossRefPubMed
12.
go back to reference Milcu AI, Istrate SL, Ungureanu E et al (2022) The role of vitreous management in the posterior capsule rupture associated with cataract surgery on the protection of the corneal endothelium. Roman J Ophthalmol 66:132–134 Milcu AI, Istrate SL, Ungureanu E et al (2022) The role of vitreous management in the posterior capsule rupture associated with cataract surgery on the protection of the corneal endothelium. Roman J Ophthalmol 66:132–134
Metadata
Title
Accuracy of 10 MHz ultrasonography for evaluation of posterior lens capsule in traumatic cataract
Authors
Xixuan Ke
Cuilian Li
Liyu Lin
Yuqiang Huang
Honghe Xia
Chuang Jin
Tingkun Shi
Qi Zhang
Xulong Liao
Haoyu Chen
Publication date
17-05-2024
Publisher
Springer Berlin Heidelberg
Published in
Graefe's Archive for Clinical and Experimental Ophthalmology
Print ISSN: 0721-832X
Electronic ISSN: 1435-702X
DOI
https://doi.org/10.1007/s00417-024-06523-9