Abstract

Purpose

To compare efficacy and safety results of an ab interno gel implant in patients with pseudoexfoliation glaucoma (PXG) and primary open angle glaucoma (POAG).

Methods

Retrospective analysis of the medical records of 110 consecutive eyes with open angle glaucoma who had received a XEN45 gel implant between March 2014 and June 2015. Intraocular pressure course, number of glaucoma medications, the need for additional intervention (including needling) and complications were evaluated until 12 months postoperatively.

Results

Data of 67 eyes with POAG and 43 eyes with PXG were analyzed. At 12 months postoperatively, the mean IOP had significantly decreased by 54.0% from preoperatively 31.85 ± 8.5 mmHg to 13.99 ± 2.6 mmHg in the POAG group, (p = 0.000; Wilcoxon test), and by 55.2% from 31.63 ± 9.0 mmHg to 13.28 ± 3.1 mmHg in the PXG group (p = 0.000; Wilcoxon test). The mean number of anti-glaucoma medications had significantly decreased from 3.25 ± 0.8 at baseline to 0.3 ± 0.7 medications at 12 months postoperatively in POAG eyes (p = 0.000; Wilcoxon test), and from 3.05 ± 1.0 to 0.3 ± 0.6 medications in PXG eyes (p = 0.000; Wilcoxon test). Hypotony (IOP ≤ 6 mmHg) was observed in 2 POAG eyes (3.0%) and in 5 PXG eyes (11.7%) at 1 month but normalized in all eyes at 12 months postoperatively. Severe complications were not observed. No statistically significant differences were found between PXG eyes and POAG eyes.

Conclusion

Our data indicate that the XEN45 gel implant provides significant and comparable reduction in IOP and anti-glaucoma medication during the one-year follow-up period in POAG as well as PXG eyes. This suggests that it may be a noteworthy alternative to traditional filtering procedures in patients with POAG and PXG respectively.
Literature
1.
go back to reference Cvenkel B, Kontestabile AS. Correlation between nerve fibre layer thickness measured with spectral domain OCT and visual field in patients with different stages of glaucoma. Graefes Arch Clin Exp Ophthalmol. 2011;249:575–84.CrossRef Cvenkel B, Kontestabile AS. Correlation between nerve fibre layer thickness measured with spectral domain OCT and visual field in patients with different stages of glaucoma. Graefes Arch Clin Exp Ophthalmol. 2011;249:575–84.CrossRef
2.
go back to reference Tham YC, Li X, Wong TY, Quigley HA, et al. Global prevalence of glaucoma and projections of glaucoma burden through 2040: a systematic review and meta-analysis. Ophthalmology. 2014;121:2081–90.CrossRef Tham YC, Li X, Wong TY, Quigley HA, et al. Global prevalence of glaucoma and projections of glaucoma burden through 2040: a systematic review and meta-analysis. Ophthalmology. 2014;121:2081–90.CrossRef
3.
go back to reference Heijl A, Leske MC, Bengtsson B, Early Manifest Glaucoma Trial Group, et al. Reduction of intraocular pressure and glaucoma progression: results from the Early Manifest Glaucoma Trial. Arch Ophthalmol. 2002;120:1268–79.CrossRef Heijl A, Leske MC, Bengtsson B, Early Manifest Glaucoma Trial Group, et al. Reduction of intraocular pressure and glaucoma progression: results from the Early Manifest Glaucoma Trial. Arch Ophthalmol. 2002;120:1268–79.CrossRef
4.
go back to reference European Glaucoma Society (EGS). Terminology and guidelines for glaucoma. 4th ed; 2014. European Glaucoma Society (EGS). Terminology and guidelines for glaucoma. 4th ed; 2014.
5.
go back to reference Gedde SJ, Herndon LW, Brandt JD, et al. Tube versus trabeculectomy study group. Postoperative complications in the tube versus trabeculectomy (TVT) study during five years of follow-up. Am J Ophthalmol. 2012;153:804–14.CrossRef Gedde SJ, Herndon LW, Brandt JD, et al. Tube versus trabeculectomy study group. Postoperative complications in the tube versus trabeculectomy (TVT) study during five years of follow-up. Am J Ophthalmol. 2012;153:804–14.CrossRef
6.
go back to reference Gedde SJ, Schiffman JC, Feuer WJ, et al. Tube versus trabeculectomy study group. Treatment outcomes in the tube versus trabeculectomy (TVT) study after five years of follow-up. Am J Ophthalmol. 2012;153:789–803.CrossRef Gedde SJ, Schiffman JC, Feuer WJ, et al. Tube versus trabeculectomy study group. Treatment outcomes in the tube versus trabeculectomy (TVT) study after five years of follow-up. Am J Ophthalmol. 2012;153:789–803.CrossRef
7.
go back to reference Jampel HD, Musch DC, Gillespie BW, et al. Perioperative complications of trabeculectomy in the collaborative initial glaucoma treatment study (CIGTS). Am J Ophthalmol. 2005;140:16–22.CrossRef Jampel HD, Musch DC, Gillespie BW, et al. Perioperative complications of trabeculectomy in the collaborative initial glaucoma treatment study (CIGTS). Am J Ophthalmol. 2005;140:16–22.CrossRef
8.
go back to reference Richter GM, Coleman AL. Minimally invasive glaucoma surgery: current status and future prospects. Clin Ophthalmol. 2016;10:189–206.PubMedPubMedCentral Richter GM, Coleman AL. Minimally invasive glaucoma surgery: current status and future prospects. Clin Ophthalmol. 2016;10:189–206.PubMedPubMedCentral
9.
go back to reference Vera VI, Horvath C. XEN gel stent: the solution designed by Aquesys. In: Samples JR, Ahmed IIK, editors. Surgical innovations in glaucoma. New York: Springer Science + Business Media NY; 2014. p. 189–98.CrossRef Vera VI, Horvath C. XEN gel stent: the solution designed by Aquesys. In: Samples JR, Ahmed IIK, editors. Surgical innovations in glaucoma. New York: Springer Science + Business Media NY; 2014. p. 189–98.CrossRef
10.
go back to reference Lewis RA. Ab interno approach to the subconjunctival space using a collagen glaucoma stent. J Cat Refract Surg. 2014;40:1301–6.CrossRef Lewis RA. Ab interno approach to the subconjunctival space using a collagen glaucoma stent. J Cat Refract Surg. 2014;40:1301–6.CrossRef
11.
go back to reference Sheybani A, Reitsamer H, Ahmed IIK. Fluid dynamics of a novel micro-fistula implant for the surgical treatment of glaucoma. Invest Ophthalmol Vis Sci. 2015;56:4789–95.CrossRef Sheybani A, Reitsamer H, Ahmed IIK. Fluid dynamics of a novel micro-fistula implant for the surgical treatment of glaucoma. Invest Ophthalmol Vis Sci. 2015;56:4789–95.CrossRef
12.
go back to reference Yu D-Y, Morgan WH, Sun X, et al. The critical role of the conjunctiva in glaucoma filtration surgery. Prog Retin Eye Res. 2009;28:303–28.CrossRef Yu D-Y, Morgan WH, Sun X, et al. The critical role of the conjunctiva in glaucoma filtration surgery. Prog Retin Eye Res. 2009;28:303–28.CrossRef
13.
go back to reference Sheybani A, Dick B, Ahmed IIK. Early clinical results of a novel ab interno gel stent for the surgical treatment of open-angle glaucoma. J Glaucoma. 2016;25:e691–6.CrossRef Sheybani A, Dick B, Ahmed IIK. Early clinical results of a novel ab interno gel stent for the surgical treatment of open-angle glaucoma. J Glaucoma. 2016;25:e691–6.CrossRef
14.
go back to reference Hengerer FH, Kohnen T, Mueller M, Conrad-Hengerer I. Ab interno gel implant for the treatment of glaucoma patients with or without prior glaucoma surgery - one year results. J Glaucoma. 2017;26:1130–6.PubMed Hengerer FH, Kohnen T, Mueller M, Conrad-Hengerer I. Ab interno gel implant for the treatment of glaucoma patients with or without prior glaucoma surgery - one year results. J Glaucoma. 2017;26:1130–6.PubMed
15.
go back to reference Grover DS, Flynn WJ, Bashford KP, Lewis RA, Duh YJ, Nangia RS, Niksch B. Performance and safety of a new ab interno gelatin stent in refractory glaucoma at 12 months. Am J Ophthalmol. 2017;183:25–36.CrossRef Grover DS, Flynn WJ, Bashford KP, Lewis RA, Duh YJ, Nangia RS, Niksch B. Performance and safety of a new ab interno gelatin stent in refractory glaucoma at 12 months. Am J Ophthalmol. 2017;183:25–36.CrossRef
16.
go back to reference Galal A, Bilgic A, Eltanamly R, Osman A. XEN glaucoma implant with mitomycin C 1-year follow-up: result and complications. J Ophthalmol. 2017;2017:5457246.CrossRef Galal A, Bilgic A, Eltanamly R, Osman A. XEN glaucoma implant with mitomycin C 1-year follow-up: result and complications. J Ophthalmol. 2017;2017:5457246.CrossRef
18.
go back to reference Sheybani A, Ahmed IK. Ab interno gelatin stent with mitomycin-C combined with cataract surgery for treatment of open-angle glaucoma: 1-year results: Presented at ASCRS; 2015. Sheybani A, Ahmed IK. Ab interno gelatin stent with mitomycin-C combined with cataract surgery for treatment of open-angle glaucoma: 1-year results: Presented at ASCRS; 2015.
19.
go back to reference Barton K, Sng C, Vera V. XEN45™ implantation for primary open-angle glaucoma: one-year results of a multicenter study: Poster presented at the ASCRS; 2016. p. 6.01. Barton K, Sng C, Vera V. XEN45™ implantation for primary open-angle glaucoma: one-year results of a multicenter study: Poster presented at the ASCRS; 2016. p. 6.01.
20.
go back to reference Directions for use for the XEN 45 GLAUCOMA TREATMENT SYSTEM. Europe. Directions for use for the XEN 45 GLAUCOMA TREATMENT SYSTEM. Europe.
21.
go back to reference Directions for use for the XEN 45 GLAUCOMA TREATMENT SYSTEM. U.S. Directions for use for the XEN 45 GLAUCOMA TREATMENT SYSTEM. U.S.
22.
go back to reference Aboobakar IF, Johnson WM, Stamer WD, Hauser MA, Allingham RR. Major review: exfoliation syndrome; advances in disease genetics, molecular biology, and epidemiology. Exp Eye Res. 2017;154:88–103.CrossRef Aboobakar IF, Johnson WM, Stamer WD, Hauser MA, Allingham RR. Major review: exfoliation syndrome; advances in disease genetics, molecular biology, and epidemiology. Exp Eye Res. 2017;154:88–103.CrossRef
23.
go back to reference Brooks AMV, Gillies WE. The presentation and prognosis of glaucoma in pseudoexfoliation of the lens capsule. Ophthalmology. 1988;95:271–6.CrossRef Brooks AMV, Gillies WE. The presentation and prognosis of glaucoma in pseudoexfoliation of the lens capsule. Ophthalmology. 1988;95:271–6.CrossRef
24.
go back to reference Quaranta L, Riva I, Gerardi C, et al. Quality of life in glaucoma: a review of the literature. Adv Ther. 2016;33:959–81.CrossRef Quaranta L, Riva I, Gerardi C, et al. Quality of life in glaucoma: a review of the literature. Adv Ther. 2016;33:959–81.CrossRef
25.
go back to reference Ilveskoski L, Tuuminen R. Combined microinvasive glaucoma and cataract surgery in patients with pseudoexfoliation glaucoma: clinical results of a gel stent. J Cataract Refract Surg. 2017;43:1124–5.CrossRef Ilveskoski L, Tuuminen R. Combined microinvasive glaucoma and cataract surgery in patients with pseudoexfoliation glaucoma: clinical results of a gel stent. J Cataract Refract Surg. 2017;43:1124–5.CrossRef
Metadata
Title
Ab interno gel implant in patients with primary open angle glaucoma and pseudoexfoliation glaucoma
Authors
Fritz H. Hengerer
Gerd U. Auffarth
Timur M. Yildirim
Ina Conrad-Hengerer
Publication date
01-12-2018
Publisher
BioMed Central
Published in
BMC Ophthalmology / Issue 1/2018
Electronic ISSN: 1471-2415
DOI
https://doi.org/10.1186/s12886-018-0989-6

Other articles of this Issue 1/2018

BMC Ophthalmology 1/2018 Go to the issue