01-01-2008 | Original Article

A time resolved intense pulsed light spectral analysis system

Authors: D. M. Clarkson, D. Gill, M. Odeke

Published in: Lasers in Medical Science | Issue 1/2008

Login to get access

Abstract

Intense pulsed light systems are currently in widespread use in clinical applications. Verification of spectral content and associated pulse waveforms is, however, not featured in product support and calibration. A measurement system was developed to determine the spectral output of such sources within a series of discrete wavelength intervals. Such a system utilised a series of 11 broadband optical filters with centre wavelengths within the range 450–950 nm in circuit with silicon photodiodes as optical detectors. Signals were captured using a low cost 8-channel 16-bit universal serial bus data capture module interfaced to a laptop computer. This allowed the pulse profile of selected filter components to be separately captured and analysed. Calibration of individual filter channels was undertaken using a Bentham dmc150 spectroradiometer and reference tungsten light source. Initial measurements undertaken of the intense pulsed light output of a Lumenis One system using the system are described.
Literature
2.
go back to reference Ross EV (2006) Laser versus intense pulsed light: competing technologies in dermatology. Lasers Surg Med 38:261–272PubMedCrossRef Ross EV (2006) Laser versus intense pulsed light: competing technologies in dermatology. Lasers Surg Med 38:261–272PubMedCrossRef
3.
go back to reference Myers P, Bowler P, Hills S (2005) A retrospective study of the efficacy of intense pulsed light for the treatment of dermatologic disorders presenting to a cosmetic skin clinic. J Cosmet Dermatol 4:262–266PubMedCrossRef Myers P, Bowler P, Hills S (2005) A retrospective study of the efficacy of intense pulsed light for the treatment of dermatologic disorders presenting to a cosmetic skin clinic. J Cosmet Dermatol 4:262–266PubMedCrossRef
4.
go back to reference Fodor L, Ramon Y, Fodor A, Carmi N, Peled IJ, Ullman Y (2006) A side-by-side prospective study of intense pulsed light and Nd:YAG laser treatment for vascular lesions. Ann Plast Surg 56:164–170PubMedCrossRef Fodor L, Ramon Y, Fodor A, Carmi N, Peled IJ, Ullman Y (2006) A side-by-side prospective study of intense pulsed light and Nd:YAG laser treatment for vascular lesions. Ann Plast Surg 56:164–170PubMedCrossRef
5.
go back to reference Schroeter CA, Haaf-von Below S, Neuman HA (2005) Effective treatment of rosacea using intense pulsed light systems. Dermatol Surg 31:1285–1289PubMedCrossRef Schroeter CA, Haaf-von Below S, Neuman HA (2005) Effective treatment of rosacea using intense pulsed light systems. Dermatol Surg 31:1285–1289PubMedCrossRef
6.
go back to reference Veynberg B, Epshtein PV (2005) Spectrum controlled IPL. Proc SPIE Int Soc Opt Eng 5686:119–125 Veynberg B, Epshtein PV (2005) Spectrum controlled IPL. Proc SPIE Int Soc Opt Eng 5686:119–125
7.
go back to reference Clarkson DM (2004) The role of measurement of pulse duration and pulse profile for lasers and intense pulsed light sources. J Med Eng 28:132–136CrossRef Clarkson DM (2004) The role of measurement of pulse duration and pulse profile for lasers and intense pulsed light sources. J Med Eng 28:132–136CrossRef
8.
go back to reference EN14255-1 (2005) Measurement and assessment of personal exposures to incoherent optical radiation—part 2: visible and infrared radiation emitted by artificial sources in the workplace EN14255-1 (2005) Measurement and assessment of personal exposures to incoherent optical radiation—part 2: visible and infrared radiation emitted by artificial sources in the workplace
9.
go back to reference ICNIRP (1997) Guidelines on limits of exposure to broad-band incoherent optical radiation (0.38 to 3 μm). Health Phys 73:539–554 ICNIRP (1997) Guidelines on limits of exposure to broad-band incoherent optical radiation (0.38 to 3 μm). Health Phys 73:539–554
10.
go back to reference Clarkson DM (2006) Determination of eye safety filter protection factors associated with retinal thermal hazard and blue light photochemical hazard for intense pulsed light sources. Phys Med Biol 51:N59–N64PubMedCrossRef Clarkson DM (2006) Determination of eye safety filter protection factors associated with retinal thermal hazard and blue light photochemical hazard for intense pulsed light sources. Phys Med Biol 51:N59–N64PubMedCrossRef
Metadata
Title
A time resolved intense pulsed light spectral analysis system
Authors
D. M. Clarkson
D. Gill
M. Odeke
Publication date
01-01-2008
Publisher
Springer-Verlag
Published in
Lasers in Medical Science / Issue 1/2008
Print ISSN: 0268-8921
Electronic ISSN: 1435-604X
DOI
https://doi.org/10.1007/s10103-007-0457-7

Other articles of this Issue 1/2008

Lasers in Medical Science 1/2008 Go to the issue