Skip to main content
Top
Published in: Journal of Clinical Monitoring and Computing 3/2018

01-06-2018 | Original Research

A smartphone application to determine body length for body weight estimation in children: a prospective clinical trial

Authors: Oliver Wetzel, Alexander R. Schmidt, Michelle Seiler, Davide Scaramuzza, Burkhardt Seifert, Donat R. Spahn, Philipp Stein

Published in: Journal of Clinical Monitoring and Computing | Issue 3/2018

Login to get access

Abstract

The aim of this study was to test the feasibility and accuracy of a smartphone application to measure the body length of children using the integrated camera and to evaluate the subsequent weight estimates. A prospective clinical trial of children aged 0–<13 years admitted to the emergency department of the University Children’s Hospital Zurich. The primary outcome was to validate the length measurement by the smartphone application «Optisizer». The secondary outcome was to correlate the virtually calculated ordinal categories based on the length measured by the app to the categories based on the real length. The third and independent outcome was the comparison of the different weight estimations by physicians, nurses, parents and the app. For all 627 children, the Bland Altman analysis showed a bias of −0.1% (95% CI −0.3–0.2%) comparing real length and length measured by the app. Ordinal categories of real length were in excellent agreement with categories virtually calculated based upon app length (kappa = 0.83, 95% CI 0.79–0.86). Children’s real weight was underestimated by physicians (−3.3, 95% CI −4.4 to −2.2%, p < 0.001), nurses (−2.6, 95% CI −3.8 to −1.5%, p < 0.001) and parents (−1.3, 95% CI −1.9 to −0.6%, p < 0.001) but overestimated by categories based upon app length (1.6, 95% CI 0.3–2.8%, p = 0.02) and categories based upon real length (2.3, 95% CI 1.1–3.5%, p < 0.001). Absolute weight differences were lowest, if estimated by the parents (5.4, 95% CI 4.9–5.9%, p < 0.001). This study showed the accuracy of length measurement of children by a smartphone application: body length determined by the smartphone application is in good agreement with the real patient length. Ordinal length categories derived from app-measured length are in excellent agreement with the ordinal length categories based upon the real patient length. The body weight estimations based upon length corresponded to known data and limitations. Precision of body weight estimations by paediatric physicians and nurses were comparable and not different to length based estimations. In this non-emergency setting, parental weight estimation was significantly better than all other means of estimation (paediatric physicians and nurses, length based estimations) in terms of precision and absolute difference.
Literature
2.
go back to reference Schmidt AR, Haas T, Buehler KP, Ruetzler K, Weiss M, Schmitz A (2015) Comparison of Broselow® tape and pediatric emergency ruler. Notfall Rettungsmed. doi:10.1007/s10049-015-0070-4. Schmidt AR, Haas T, Buehler KP, Ruetzler K, Weiss M, Schmitz A (2015) Comparison of Broselow® tape and pediatric emergency ruler. Notfall Rettungsmed. doi:10.​1007/​s10049-015-0070-4.
4.
go back to reference Weiss M, Knirsch W, Kretschmar O, Dullenkopf A, Tomaske M, Balmer C, Stutz K, Gerber AC, Berger F. Tracheal tube-tip displacement in children during head-neck movement–a radiological assessment. Br J Anaesth. 2006;96:486–91. doi:10.1093/bja/ael014.CrossRefPubMed Weiss M, Knirsch W, Kretschmar O, Dullenkopf A, Tomaske M, Balmer C, Stutz K, Gerber AC, Berger F. Tracheal tube-tip displacement in children during head-neck movement–a radiological assessment. Br J Anaesth. 2006;96:486–91. doi:10.​1093/​bja/​ael014.CrossRefPubMed
5.
go back to reference Luten RC, Wears RL, Broselow J, Zaritsky A, Barnett TM, Lee T, Bailey A, Vally R, Brown R, Rosenthal B. Length-based endotracheal tube and emergency equipment in pediatrics. Ann Emerg Med. 1992;21:900–4.CrossRefPubMed Luten RC, Wears RL, Broselow J, Zaritsky A, Barnett TM, Lee T, Bailey A, Vally R, Brown R, Rosenthal B. Length-based endotracheal tube and emergency equipment in pediatrics. Ann Emerg Med. 1992;21:900–4.CrossRefPubMed
12.
13.
go back to reference Olson E (2011) AprilTag: a robust and flexible visual fiducial system. IEEE inter-national conference on robotics and automation ICRA 2011, pp 3400–3407. IEEE:New York. Olson E (2011) AprilTag: a robust and flexible visual fiducial system. IEEE inter-national conference on robotics and automation ICRA 2011, pp 3400–3407. IEEE:New York.
14.
go back to reference Lubitz DS, Seidel JS, Chameides L, Luten RC, Zaritsky AL, Campbell FW. A rapid method for estimating weight and resuscitation drug dosages from length in the pediatric age group. Ann Emerg Med. 1988;17:576–81.CrossRefPubMed Lubitz DS, Seidel JS, Chameides L, Luten RC, Zaritsky AL, Campbell FW. A rapid method for estimating weight and resuscitation drug dosages from length in the pediatric age group. Ann Emerg Med. 1988;17:576–81.CrossRefPubMed
15.
go back to reference Prader A, Largo RH, Molinari L, Issler C. Physical growth of Swiss children from birth to 20 years of age. First Zurich longitudinal study of growth and development. Helv Paediatr Acta Suppl. 1989;52:1–125.PubMed Prader A, Largo RH, Molinari L, Issler C. Physical growth of Swiss children from birth to 20 years of age. First Zurich longitudinal study of growth and development. Helv Paediatr Acta Suppl. 1989;52:1–125.PubMed
17.
go back to reference Hofer CK, Ganter M, Tucci M, Klaghofer R, Zollinger A. How reliable is length-based determination of body weight and tracheal tube size in the paediatric age group? The Broselow tape reconsidered. Br J Anaesth. 2002;88:283–5.CrossRefPubMed Hofer CK, Ganter M, Tucci M, Klaghofer R, Zollinger A. How reliable is length-based determination of body weight and tracheal tube size in the paediatric age group? The Broselow tape reconsidered. Br J Anaesth. 2002;88:283–5.CrossRefPubMed
21.
go back to reference Goldman RD, Buskin S, Augarten A. Parental estimates of their child’s weight: accurate for resuscitation drug doses. Pediatr Emerg Care. 1999;15:19–21.CrossRefPubMed Goldman RD, Buskin S, Augarten A. Parental estimates of their child’s weight: accurate for resuscitation drug doses. Pediatr Emerg Care. 1999;15:19–21.CrossRefPubMed
22.
go back to reference Trakulsrichai S, Boonsri C, Chatchaipun P, Chunharas A. Accuracy of three methods used for Thai children’s body weight estimation. J Med Assoc Thai. 2012;95:1194–9.PubMed Trakulsrichai S, Boonsri C, Chatchaipun P, Chunharas A. Accuracy of three methods used for Thai children’s body weight estimation. J Med Assoc Thai. 2012;95:1194–9.PubMed
23.
go back to reference Harris M, Patterson J, Morse J. Doctors, nurses, and parents are equally poor at estimating pediatric weights. Pediatr Emerg Care. 1999;15:17–8.CrossRefPubMed Harris M, Patterson J, Morse J. Doctors, nurses, and parents are equally poor at estimating pediatric weights. Pediatr Emerg Care. 1999;15:17–8.CrossRefPubMed
27.
30.
go back to reference KIM EJ, KIM SY, KIM WO, KIM H, KIL HK. Ultrasound measurement of subglottic diameter and an empirical formula for proper endotracheal tube fitting in children. Acta Anaesthesiol Scand. 2013;57:1124–30. doi:10.1111/aas.12167.CrossRefPubMed KIM EJ, KIM SY, KIM WO, KIM H, KIL HK. Ultrasound measurement of subglottic diameter and an empirical formula for proper endotracheal tube fitting in children. Acta Anaesthesiol Scand. 2013;57:1124–30. doi:10.​1111/​aas.​12167.CrossRefPubMed
31.
go back to reference Weiss M, Dullenkopf A, Bottcher S, Schmitz A, Stutz K, Gysin C, Gerber AC. Clinical evaluation of cuff and tube tip position in a newly designed paediatric preformed oral cuffed tracheal tube. Br J Anaesth. 2006;97:695–700. doi:10.1093/bja/ael247.CrossRefPubMed Weiss M, Dullenkopf A, Bottcher S, Schmitz A, Stutz K, Gysin C, Gerber AC. Clinical evaluation of cuff and tube tip position in a newly designed paediatric preformed oral cuffed tracheal tube. Br J Anaesth. 2006;97:695–700. doi:10.​1093/​bja/​ael247.CrossRefPubMed
Metadata
Title
A smartphone application to determine body length for body weight estimation in children: a prospective clinical trial
Authors
Oliver Wetzel
Alexander R. Schmidt
Michelle Seiler
Davide Scaramuzza
Burkhardt Seifert
Donat R. Spahn
Philipp Stein
Publication date
01-06-2018
Publisher
Springer Netherlands
Published in
Journal of Clinical Monitoring and Computing / Issue 3/2018
Print ISSN: 1387-1307
Electronic ISSN: 1573-2614
DOI
https://doi.org/10.1007/s10877-017-0041-z

Other articles of this Issue 3/2018

Journal of Clinical Monitoring and Computing 3/2018 Go to the issue