Skip to main content
Top
Published in: Journal of the Association for Research in Otolaryngology 1/2012

01-02-2012

A Psychophysical Method for Measuring Spatial Resolution in Cochlear Implants

Authors: Mahan Azadpour, Colette M. McKay

Published in: Journal of the Association for Research in Otolaryngology | Issue 1/2012

Login to get access

Abstract

A novel psychophysical method was developed for assessing spatial resolution in cochlear implants. Spectrally flat and spectrally peaked pulse train stimuli were generated by interleaving pulses on 11 electrodes. Spectrally flat stimuli used loudness-balanced currents and the spectrally peaked stimuli had a single spatial ripple with the current of the middle electrode raised to create a peak while the currents on two electrodes equally spaced at variable distance from the peak electrode were reduced to create valleys. The currents on peak and valley electrodes were adjusted to balance the overall loudness with the spectrally flat stimulus, while keeping the currents on flanking electrodes fixed. The psychometric functions obtained from percent correct discrimination of peaked and flat stimuli versus the distance between peak and valley electrodes were used to quantify spatial resolution for each of the eight subjects. The ability to resolve the spatial ripple correlated strongly with current level difference limens measured on the peak electrode. The results were consistent with a hypothesis that a factor other than spread of excitation (such as neural response variance) might underlie much of the variability in spatial resolution. Resolution ability was not correlated with phoneme recognition in quiet or sentence recognition in quiet and background noise, consistent with a hypothesis that implantees rely on cues other than fine spectral detail to identify speech, perhaps because this detail is poorly accessible or unreliable.
Literature
go back to reference Chatterjee M, Shannon RV (1998) Forward masked excitation patterns in multielectrode electrical stimulation. J Acoust Soc Am 103:2565–2572PubMedCrossRef Chatterjee M, Shannon RV (1998) Forward masked excitation patterns in multielectrode electrical stimulation. J Acoust Soc Am 103:2565–2572PubMedCrossRef
go back to reference Chatterjee M, Yu J (2010) A relation between electrode discrimination and amplitude modulation detection by cochlear implant listeners. J Acoust Soc Am 127:415–426PubMedCrossRef Chatterjee M, Yu J (2010) A relation between electrode discrimination and amplitude modulation detection by cochlear implant listeners. J Acoust Soc Am 127:415–426PubMedCrossRef
go back to reference Dorman MF, Loizou PC, Rainey D (1997) Speech intelligibility as a function of the number of channels of stimulation for signal processors using sine-wave and noise-band outputs. J Acoust Soc Am 102:2403–2411PubMedCrossRef Dorman MF, Loizou PC, Rainey D (1997) Speech intelligibility as a function of the number of channels of stimulation for signal processors using sine-wave and noise-band outputs. J Acoust Soc Am 102:2403–2411PubMedCrossRef
go back to reference Drennan WR, Pfingst BE (2006) Current-level discrimination in the context of interleaved, multichannel stimulation in cochlear implants: effects of number of stimulated electrodes, pulse rate, and electrode separation. J Assoc Res Otolaryngol 7:308–316PubMedCrossRef Drennan WR, Pfingst BE (2006) Current-level discrimination in the context of interleaved, multichannel stimulation in cochlear implants: effects of number of stimulated electrodes, pulse rate, and electrode separation. J Assoc Res Otolaryngol 7:308–316PubMedCrossRef
go back to reference Drennan WR, Won JH, Nie K, Jameyson E, Rubinstein JT (2010) Sensitivity of psychophysical measures to signal processor modifications in cochlear implant users. Hear Res 262:1–8PubMedCrossRef Drennan WR, Won JH, Nie K, Jameyson E, Rubinstein JT (2010) Sensitivity of psychophysical measures to signal processor modifications in cochlear implant users. Hear Res 262:1–8PubMedCrossRef
go back to reference Friesen LM, Shannon RV, Baskent D, Wang X (2001) Speech recognition in noise as a function of the number of spectral channels: comparison of acoustic hearing and cochlear implants. J Acoust Soc Am 110:1150–1163PubMedCrossRef Friesen LM, Shannon RV, Baskent D, Wang X (2001) Speech recognition in noise as a function of the number of spectral channels: comparison of acoustic hearing and cochlear implants. J Acoust Soc Am 110:1150–1163PubMedCrossRef
go back to reference Fu QJ, Nogaki G (2005) Noise susceptibility of cochlear implant users: the role of spectral resolution and smearing. J Assoc Res Otolaryngol 6:19–27PubMedCrossRef Fu QJ, Nogaki G (2005) Noise susceptibility of cochlear implant users: the role of spectral resolution and smearing. J Assoc Res Otolaryngol 6:19–27PubMedCrossRef
go back to reference Galvin JJ 3rd, Fu QJ (2005) Effects of stimulation rate, mode and level on modulation detection by cochlear implant users. J Assoc Res Otolaryngol 6:269–279PubMedCrossRef Galvin JJ 3rd, Fu QJ (2005) Effects of stimulation rate, mode and level on modulation detection by cochlear implant users. J Assoc Res Otolaryngol 6:269–279PubMedCrossRef
go back to reference Goupell MJ, Laback B, Majdak P, Baumgartner WD (2008) Current-level discrimination and spectral profile analysis in multi-channel electrical stimulation. J Acoust Soc Am 124:3142–3157PubMedCrossRef Goupell MJ, Laback B, Majdak P, Baumgartner WD (2008) Current-level discrimination and spectral profile analysis in multi-channel electrical stimulation. J Acoust Soc Am 124:3142–3157PubMedCrossRef
go back to reference Green DM (1988) Profile analysis: auditory intensity discrimination. Oxford University Press, Oxford Green DM (1988) Profile analysis: auditory intensity discrimination. Oxford University Press, Oxford
go back to reference Hansen M (2006) Lehre und ausbildung in psychoakustik mit psylab: Freie software für psychoakustische experimente. In: Fortschritte der akustik Dega, Braunschweig, pp 591–592 Hansen M (2006) Lehre und ausbildung in psychoakustik mit psylab: Freie software für psychoakustische experimente. In: Fortschritte der akustik Dega, Braunschweig, pp 591–592
go back to reference Henry BA, Turner CW (2003) The resolution of complex spectral patterns by cochlear implant and normal-hearing listeners. J Acoust Soc Am 113:2861–2873PubMedCrossRef Henry BA, Turner CW (2003) The resolution of complex spectral patterns by cochlear implant and normal-hearing listeners. J Acoust Soc Am 113:2861–2873PubMedCrossRef
go back to reference Henry BA, Turner CW, Behrens A (2005) Spectral peak resolution and speech recognition in quiet: normal hearing, hearing impaired, and cochlear implant listeners. J Acoust Soc Am 118:1111–1121PubMedCrossRef Henry BA, Turner CW, Behrens A (2005) Spectral peak resolution and speech recognition in quiet: normal hearing, hearing impaired, and cochlear implant listeners. J Acoust Soc Am 118:1111–1121PubMedCrossRef
go back to reference Hughes ML, Stille LJ (2008) Psychophysical versus physiological spatial forward masking and the relation to speech perception in cochlear implants. Ear Hear 29:435–452PubMedCrossRef Hughes ML, Stille LJ (2008) Psychophysical versus physiological spatial forward masking and the relation to speech perception in cochlear implants. Ear Hear 29:435–452PubMedCrossRef
go back to reference Litvak LM, Spahr AJ, Saoji AA, Fridman GY (2007) Relationship between perception of spectral ripple and speech recognition in cochlear implant and vocoder listeners. J Acoust Soc Am 122:982–991PubMedCrossRef Litvak LM, Spahr AJ, Saoji AA, Fridman GY (2007) Relationship between perception of spectral ripple and speech recognition in cochlear implant and vocoder listeners. J Acoust Soc Am 122:982–991PubMedCrossRef
go back to reference McKay CM, Remine MD, McDermott HJ (2001) Loudness summation for pulsatile electrical stimulation of the cochlea: effects of rate, electrode separation, level, and mode of stimulation. J Acoust Soc Am 110:1514–1524PubMedCrossRef McKay CM, Remine MD, McDermott HJ (2001) Loudness summation for pulsatile electrical stimulation of the cochlea: effects of rate, electrode separation, level, and mode of stimulation. J Acoust Soc Am 110:1514–1524PubMedCrossRef
go back to reference McKay CM, Henshall KR, Farrell RJ, McDermott HJ (2003) A practical method of predicting the loudness of complex electrical stimuli. J Acoust Soc Am 113:2054–2063PubMedCrossRef McKay CM, Henshall KR, Farrell RJ, McDermott HJ (2003) A practical method of predicting the loudness of complex electrical stimuli. J Acoust Soc Am 113:2054–2063PubMedCrossRef
go back to reference Nelson DA, Schmitz JL, Donaldson GS, Viemeister NF, Javel E (1996) Intensity discrimination as a function of stimulus level with electric stimulation. J Acoust Soc Am 100:2393–2414PubMedCrossRef Nelson DA, Schmitz JL, Donaldson GS, Viemeister NF, Javel E (1996) Intensity discrimination as a function of stimulus level with electric stimulation. J Acoust Soc Am 100:2393–2414PubMedCrossRef
go back to reference Nelson DA, Donaldson GS, Kreft H (2008) Forward-masked spatial tuning curves in cochlear implant users. J Acoust Soc Am 123:1522–1543PubMedCrossRef Nelson DA, Donaldson GS, Kreft H (2008) Forward-masked spatial tuning curves in cochlear implant users. J Acoust Soc Am 123:1522–1543PubMedCrossRef
go back to reference Saoji AA, Litvak L, Spahr AJ, Eddins DA (2009) Spectral modulation detection and vowel and consonant identifications in cochlear implant listeners. J Acoust Soc Am 126:955–958PubMedCrossRef Saoji AA, Litvak L, Spahr AJ, Eddins DA (2009) Spectral modulation detection and vowel and consonant identifications in cochlear implant listeners. J Acoust Soc Am 126:955–958PubMedCrossRef
go back to reference Spiegel MF, Green DM (1982) Signal and masker uncertainty with noise maskers of varying duration, bandwidth, and center frequency. J Acoust Soc Am 71:1204–1210PubMedCrossRef Spiegel MF, Green DM (1982) Signal and masker uncertainty with noise maskers of varying duration, bandwidth, and center frequency. J Acoust Soc Am 71:1204–1210PubMedCrossRef
go back to reference Supin A, Popov VV, Milekhina ON, Tarakanov MB (1998) Ripple density resolution for various rippled-noise patterns. J Acoust Soc Am 103:2042–2050PubMedCrossRef Supin A, Popov VV, Milekhina ON, Tarakanov MB (1998) Ripple density resolution for various rippled-noise patterns. J Acoust Soc Am 103:2042–2050PubMedCrossRef
go back to reference Throckmorton CS, Collins LM (1999) Investigation of the effects of temporal and spatial interactions on speech-recognition skills in cochlear-implant subjects. J Acoust Soc Am 105:861–873PubMedCrossRef Throckmorton CS, Collins LM (1999) Investigation of the effects of temporal and spatial interactions on speech-recognition skills in cochlear-implant subjects. J Acoust Soc Am 105:861–873PubMedCrossRef
go back to reference Won JH, Drennan WR, Rubinstein JT (2007) Spectral-ripple resolution correlates with speech reception in noise in cochlear implant users. J Assoc Res Otolaryngol 8:384–392PubMedCrossRef Won JH, Drennan WR, Rubinstein JT (2007) Spectral-ripple resolution correlates with speech reception in noise in cochlear implant users. J Assoc Res Otolaryngol 8:384–392PubMedCrossRef
Metadata
Title
A Psychophysical Method for Measuring Spatial Resolution in Cochlear Implants
Authors
Mahan Azadpour
Colette M. McKay
Publication date
01-02-2012
Publisher
Springer-Verlag
Published in
Journal of the Association for Research in Otolaryngology / Issue 1/2012
Print ISSN: 1525-3961
Electronic ISSN: 1438-7573
DOI
https://doi.org/10.1007/s10162-011-0294-z

Other articles of this Issue 1/2012

Journal of the Association for Research in Otolaryngology 1/2012 Go to the issue