Skip to main content
Top
Published in: International Journal of Computer Assisted Radiology and Surgery 4/2013

01-07-2013 | Original Article

A pilot study on magnetic navigation for transcatheter aortic valve implantation using dynamic aortic model and US image guidance

Authors: Zhe Luo, Junfeng Cai, Lixu Gu

Published in: International Journal of Computer Assisted Radiology and Surgery | Issue 4/2013

Login to get access

Abstract

Purpose   In this paper, we propose a pilot study for transcatheter aortic valve implantation guided by an augmented magnetic tracking system (MTS) with a dynamic aortic model and intra-operative ultrasound (US) images. Methods    The dynamic 3D aortic model is constructed from the preoperative 4D computed tomography, which is animated according to the real-time electrocardiograph (ECG) input of patient. Before the procedure, the US probe calibration is performed to map the US image coordinate to the tracked device coordinate. A temporal alignment is performed to synchronize the ECG signals, the intra-operative US image and the tracking information. Thereafter, with the assistance of synchronized ECG signals, the spatial registration is performed by using a feature-based registration. Then the augmented MTS guides the surgeon to confidently position and deploy the transcatheter aortic valve prosthesis to the target.
Results   The approach was validated by US probe calibration evaluation and animal study. The US calibration accuracy achieved \(1.37\pm 0.43\, \text{ mm}\), whereas in the animal study on three porcine subjects, fiducial, target, deployment distance and tilting errors reached \(3.16\pm 0.55\,\text{ mm}\), \(3.80\pm 1.83\,\text{ mm}\), \(3.13\pm 1.12\,\text{ mm}\) and \(5.87\pm 2.35^{\circ }\), respectively.
Conclusion   Our pilot study has revealed that the proposed approach is feasible and accurate for delivery and deployment of transcatheter aortic valve prosthesis.
Literature
1.
go back to reference Nkomo VR, Gardin JM, Skelton TN et al (2006) Burden of valvular heart diseases. Lancet 368:1005–11PubMedCrossRef Nkomo VR, Gardin JM, Skelton TN et al (2006) Burden of valvular heart diseases. Lancet 368:1005–11PubMedCrossRef
2.
go back to reference Otto CM, Knuusisto J, Reichenbach DD, Gown AM, O’Brien KD (1994) Characterization of the early lesion of “degenerative” valvular aortic stenosis. Histological and immunohistochemical studies. Circulation 90(2):844–853PubMedCrossRef Otto CM, Knuusisto J, Reichenbach DD, Gown AM, O’Brien KD (1994) Characterization of the early lesion of “degenerative” valvular aortic stenosis. Histological and immunohistochemical studies. Circulation 90(2):844–853PubMedCrossRef
3.
go back to reference Leon MB, Smith CR, Mack M, Miller DC, Moses JW et al (2010) Transcatheter aortic-valve implantation for aortic stenosis in patients who cannot undergo surgery. N Engl J Med 363(17): 1597–1607 Leon MB, Smith CR, Mack M, Miller DC, Moses JW et al (2010) Transcatheter aortic-valve implantation for aortic stenosis in patients who cannot undergo surgery. N Engl J Med 363(17): 1597–1607
4.
go back to reference Bonow R, Carabello B, Chatterjee K, de Leon AC, et al (2008) Focused update incorporated into the ACC/AHA 2006 guidelines for the management of patients with valvular heart disease: a report of the American College of Cardiology/American heart association task force on practice guidelines. doi:10.1016/j.jacc.2008.05.008 Bonow R, Carabello B, Chatterjee K, de Leon AC, et al (2008) Focused update incorporated into the ACC/AHA 2006 guidelines for the management of patients with valvular heart disease: a report of the American College of Cardiology/American heart association task force on practice guidelines. doi:10.​1016/​j.​jacc.​2008.​05.​008
5.
go back to reference Iung B, Cachier A, Baron G, Messika-Zeitoun D, Delahaye F et al (2005) Decision-making in elderly patients with severe aortic stenosis: why are so many denied surgery? Eur Heart J 26: 2714–2720 Iung B, Cachier A, Baron G, Messika-Zeitoun D, Delahaye F et al (2005) Decision-making in elderly patients with severe aortic stenosis: why are so many denied surgery? Eur Heart J 26: 2714–2720
6.
go back to reference Chu M, Borger M, Mohr F, Walther T (2010) Transcatheter heart-valve replacement: update. Can Med Assoc J 182(8):791–795CrossRef Chu M, Borger M, Mohr F, Walther T (2010) Transcatheter heart-valve replacement: update. Can Med Assoc J 182(8):791–795CrossRef
7.
go back to reference Cribier A, Eltchaninoff H, Bash A, Borenstein N, Tron C, Bauer F, Derumeaux G, Anselme F, Laborde F, Leon MB (2002) Percutaneous transcatheter implantation of an aortic valve prosthesis for calcific aortic stenosis: first human case description. Circulation 106:3006–3008PubMedCrossRef Cribier A, Eltchaninoff H, Bash A, Borenstein N, Tron C, Bauer F, Derumeaux G, Anselme F, Laborde F, Leon MB (2002) Percutaneous transcatheter implantation of an aortic valve prosthesis for calcific aortic stenosis: first human case description. Circulation 106:3006–3008PubMedCrossRef
8.
go back to reference Leipsic J, Gurvitch R, LaBounty TM, Min JK, Wood D, Johnson M, Ajlan AM, Wijesinghe N, Webb JG (2011) Multidetector computed tomography in transcatheter aortic valve implantation. J Am Coll Cardiol Imaging doi:10.1016/j.jcmg.2011.01.014 Leipsic J, Gurvitch R, LaBounty TM, Min JK, Wood D, Johnson M, Ajlan AM, Wijesinghe N, Webb JG (2011) Multidetector computed tomography in transcatheter aortic valve implantation. J Am Coll Cardiol Imaging doi:10.​1016/​j.​jcmg.​2011.​01.​014
9.
go back to reference Lang P, Seslija P, Chu MW, Bainbridge D, Guiraudon GM, Jones DL, Peters TM (2012) US-fluoroscopy registration for transcatheter aortic valve implantation. IEEE Trans Biomed Eng 59(5):1444–1453PubMedCrossRef Lang P, Seslija P, Chu MW, Bainbridge D, Guiraudon GM, Jones DL, Peters TM (2012) US-fluoroscopy registration for transcatheter aortic valve implantation. IEEE Trans Biomed Eng 59(5):1444–1453PubMedCrossRef
10.
go back to reference Delgado V, Ng A, Shanks M, Van Der Kley F, Schuijf J, Van De Veire N, Kroft L, Roos A, Schalij M, Bax J (2010) Transcatheter aortic valve implantation: role of multimodality cardiac imaging. Expert Rev Cardiovasc Ther 8(1):113–123PubMedCrossRef Delgado V, Ng A, Shanks M, Van Der Kley F, Schuijf J, Van De Veire N, Kroft L, Roos A, Schalij M, Bax J (2010) Transcatheter aortic valve implantation: role of multimodality cardiac imaging. Expert Rev Cardiovasc Ther 8(1):113–123PubMedCrossRef
11.
go back to reference Greenberg RK, Haulon S, O’Neill S, Lyden S, Ouriel K (2004) Primary endovascular repair of juxtarenal aneurysms with fenestrated endovascular grafting. Eur J Vasc Endovasc Surg 27:484–491PubMedCrossRef Greenberg RK, Haulon S, O’Neill S, Lyden S, Ouriel K (2004) Primary endovascular repair of juxtarenal aneurysms with fenestrated endovascular grafting. Eur J Vasc Endovasc Surg 27:484–491PubMedCrossRef
12.
go back to reference Tarek D (2009) An evidence-based approach to minimise contrast-induced neuropathy. N Z Med J 122(1299):39–41 Tarek D (2009) An evidence-based approach to minimise contrast-induced neuropathy. N Z Med J 122(1299):39–41
13.
go back to reference Kempfert J, Rastan A, Noettling A, Blumenstein J, Linke A, et al Perioperative dynact for improved imaging during transapical aortic valve implantation. Circulation. doi:10.1055/s-0029-1246838 Kempfert J, Rastan A, Noettling A, Blumenstein J, Linke A, et al Perioperative dynact for improved imaging during transapical aortic valve implantation. Circulation. doi:10.​1055/​s-0029-1246838
14.
go back to reference Horvath K, Mazilu D, Guttman M, Zetts A, Hunt T, Li M (2010) Midterm results of transapical aortic valve replacement via real-time magnetic resonance imaging guidance. J Thorac Cardiovasc Surg 139(2):424–430PubMedCrossRef Horvath K, Mazilu D, Guttman M, Zetts A, Hunt T, Li M (2010) Midterm results of transapical aortic valve replacement via real-time magnetic resonance imaging guidance. J Thorac Cardiovasc Surg 139(2):424–430PubMedCrossRef
15.
go back to reference Horvath K, Mazilu D, Kocaturk O, Li M (2011) Transapical aortic valve replacement under real-time magnetic resonance imaging guidance: experimental results with balloon-expandable and self-expanding stents. Eur J Cardio-Thorac Surg 39(6):822–828CrossRef Horvath K, Mazilu D, Kocaturk O, Li M (2011) Transapical aortic valve replacement under real-time magnetic resonance imaging guidance: experimental results with balloon-expandable and self-expanding stents. Eur J Cardio-Thorac Surg 39(6):822–828CrossRef
16.
go back to reference Wood BJ, Zhang H, Durrani A et al (2005) Navigation with electromagnetic tracking for interventional radiology procedures: a feasibility study. J Vasc Int Radiol 16:493–505CrossRef Wood BJ, Zhang H, Durrani A et al (2005) Navigation with electromagnetic tracking for interventional radiology procedures: a feasibility study. J Vasc Int Radiol 16:493–505CrossRef
17.
go back to reference Manstad-Hulaas F, Ommedal S, Tangen GA, Aadahl P, Hernes TN (2007) Side-branched AAA stent graft insertion using navigation technology: a phantom study. Eur Surg Res 39(6):364–371PubMedCrossRef Manstad-Hulaas F, Ommedal S, Tangen GA, Aadahl P, Hernes TN (2007) Side-branched AAA stent graft insertion using navigation technology: a phantom study. Eur Surg Res 39(6):364–371PubMedCrossRef
18.
go back to reference Abi-Jaoudeh N, Glossop N, Dake M, Pritchard WF, Chiesa A, Dreher MR, Tang T, Karanian JW, Wood BJ (2010) Electromagnetic navigation for thoracic aortic stent-graft deployment: a pilot study in swine. J Vasc Int Radiol 21:888–895CrossRef Abi-Jaoudeh N, Glossop N, Dake M, Pritchard WF, Chiesa A, Dreher MR, Tang T, Karanian JW, Wood BJ (2010) Electromagnetic navigation for thoracic aortic stent-graft deployment: a pilot study in swine. J Vasc Int Radiol 21:888–895CrossRef
19.
go back to reference Huang X, Moore J, Guiraudon G, Jones DL, Bainbridge D, Renand J, Peters TM (2009) Dynamic 2D ultrasound and 3D CT image registration of the beating heart. IEEE Trans Med Imaging 28: 1179–1189 Huang X, Moore J, Guiraudon G, Jones DL, Bainbridge D, Renand J, Peters TM (2009) Dynamic 2D ultrasound and 3D CT image registration of the beating heart. IEEE Trans Med Imaging 28: 1179–1189
20.
go back to reference Huber CH, Nasratulla M, Augstburger M, Von Segesser LK (2004) Ultrasound navigation through the heart for off-pump aortic valved stent implantation: new tool. J Endovasc Ther 11:503–510PubMedCrossRef Huber CH, Nasratulla M, Augstburger M, Von Segesser LK (2004) Ultrasound navigation through the heart for off-pump aortic valved stent implantation: new tool. J Endovasc Ther 11:503–510PubMedCrossRef
21.
go back to reference Lang P, Rajchl M, McLeod AJ, Chu MW, Peters TM (2011) Feature identification for image-guided transcatheter aortic valve implantation. In: Proceedings of SPIE Medical Imaging Conference, vol 8316. pp 83162X–83162X-14 Lang P, Rajchl M, McLeod AJ, Chu MW, Peters TM (2011) Feature identification for image-guided transcatheter aortic valve implantation. In: Proceedings of SPIE Medical Imaging Conference, vol 8316. pp 83162X–83162X-14
22.
go back to reference Luo Z, Cai JF, Wang S, Zhao Q, Peters T, Gu L (2012) Magnetic navigation for thoracic aortic stent-graft deployment using ultrasound image guidance. IEEE Trans Biomed Eng. doi:10.1109/TBME.2012.2206388 Luo Z, Cai JF, Wang S, Zhao Q, Peters T, Gu L (2012) Magnetic navigation for thoracic aortic stent-graft deployment using ultrasound image guidance. IEEE Trans Biomed Eng. doi:10.​1109/​TBME.​2012.​2206388
23.
go back to reference Sato Y, Nakamoto M, Tamaki Y et al (1998) Image guidance of breast cancer surgery using 3-D ultrasound images and augmented reality visualization. IEEE Trans Med Imaging 17:681–693PubMedCrossRef Sato Y, Nakamoto M, Tamaki Y et al (1998) Image guidance of breast cancer surgery using 3-D ultrasound images and augmented reality visualization. IEEE Trans Med Imaging 17:681–693PubMedCrossRef
24.
go back to reference Welch JN, Johnson JA, Bax M, Badr R, Shahidi R (2000) A real-time freehand 3D ultrasound system for image-guided surgery. In: Proceedings of the IEEE ultrasonic symposium, San Juan, Puerto Rico, pp 1601–1604 Welch JN, Johnson JA, Bax M, Badr R, Shahidi R (2000) A real-time freehand 3D ultrasound system for image-guided surgery. In: Proceedings of the IEEE ultrasonic symposium, San Juan, Puerto Rico, pp 1601–1604
25.
go back to reference Lindseth F, Tangen GA, Langø T et al (2003) Probe calibration for freehand 3-D ultrasound. Ultrasound Med Biol 29:1607–1623PubMedCrossRef Lindseth F, Tangen GA, Langø T et al (2003) Probe calibration for freehand 3-D ultrasound. Ultrasound Med Biol 29:1607–1623PubMedCrossRef
26.
go back to reference Frantz DD, Wiles AD, Leis SE, Kirsch SR (2003) Accuracy assessment protocols for electromagnetic tracking systems. Phys Med Biol 48:2241–2251PubMedCrossRef Frantz DD, Wiles AD, Leis SE, Kirsch SR (2003) Accuracy assessment protocols for electromagnetic tracking systems. Phys Med Biol 48:2241–2251PubMedCrossRef
27.
go back to reference Wierzbicki M, Drangova M, Guiraudon G, Peters T (2004 Sep) Validation of dynamic heart models obtained using non-linear registration for virtual reality training, planning, and guidance of minimally invasive cardiac surgeries. Med Image Anal 8(3): 387–401 Wierzbicki M, Drangova M, Guiraudon G, Peters T (2004 Sep) Validation of dynamic heart models obtained using non-linear registration for virtual reality training, planning, and guidance of minimally invasive cardiac surgeries. Med Image Anal 8(3): 387–401
28.
go back to reference Yuan, J, Bae, E, and Tai, X (2010) A study on continuous max-flow and min-cut approaches. In [IEEE conference on computer vision and pattern recognition], IEEE computer society conference on computer vision and, pattern recognition, pp 2217–2224 Yuan, J, Bae, E, and Tai, X (2010) A study on continuous max-flow and min-cut approaches. In [IEEE conference on computer vision and pattern recognition], IEEE computer society conference on computer vision and, pattern recognition, pp 2217–2224
29.
go back to reference Rajchl M, Yuan J, Ukwatta E, Peters TM (2012) Fast interactive multi-region cardiac segmentation with linearly ordered labels. In: International symposium on biomedical imaging (ISBI), 2012 IEEE International Conference on Rajchl M, Yuan J, Ukwatta E, Peters TM (2012) Fast interactive multi-region cardiac segmentation with linearly ordered labels. In: International symposium on biomedical imaging (ISBI), 2012 IEEE International Conference on
30.
go back to reference Cai JF, Luo Z, Gu L et al (2010) The implementation of an integrated computer-assisted system for minimally invasive cardiac surgery. Int J Med Robotics Comput Assist Surg 6:102–112 Cai JF, Luo Z, Gu L et al (2010) The implementation of an integrated computer-assisted system for minimally invasive cardiac surgery. Int J Med Robotics Comput Assist Surg 6:102–112
31.
go back to reference Northern Digital Inc. (2007) Aurora User Guide. Northern Digital: Waterloo, Canada Northern Digital Inc. (2007) Aurora User Guide. Northern Digital: Waterloo, Canada
32.
go back to reference John M, Liao R, Zheng YF, et al. System to Guide Transcatheter Aortic Valve Implantations Based on Interventional C-Arm CT Imaging. Med Image Comput Comput Assist Interv. doi:10.1007/978-3-642-15705-9_46 John M, Liao R, Zheng YF, et al. System to Guide Transcatheter Aortic Valve Implantations Based on Interventional C-Arm CT Imaging. Med Image Comput Comput Assist Interv. doi:10.​1007/​978-3-642-15705-9_​46
33.
go back to reference Li N, Beck T, Chen J, Biermann C, Guo L, Sun H, Gao F, Liu C (2011) Assessment of thoracic aortic elasticity: a preliminary study using electrocardiographically gated dual-source CT. Eur Radiol 21:1564–1572PubMedCrossRef Li N, Beck T, Chen J, Biermann C, Guo L, Sun H, Gao F, Liu C (2011) Assessment of thoracic aortic elasticity: a preliminary study using electrocardiographically gated dual-source CT. Eur Radiol 21:1564–1572PubMedCrossRef
Metadata
Title
A pilot study on magnetic navigation for transcatheter aortic valve implantation using dynamic aortic model and US image guidance
Authors
Zhe Luo
Junfeng Cai
Lixu Gu
Publication date
01-07-2013
Publisher
Springer Berlin Heidelberg
Published in
International Journal of Computer Assisted Radiology and Surgery / Issue 4/2013
Print ISSN: 1861-6410
Electronic ISSN: 1861-6429
DOI
https://doi.org/10.1007/s11548-012-0809-z

Other articles of this Issue 4/2013

International Journal of Computer Assisted Radiology and Surgery 4/2013 Go to the issue