Abstract

Background

Accurately aiming laser energy at a target from a two-dimensional endoscopic view is difficult during endoscopic laser surgery, particularly when the endoscope and the laser fiber are misaligned. We developed a composite optical fiberscope (COF) that can simultaneously visualize a target area and perform laser irradiation. The identical orientation of the endoscope and the laser fiber allows intuitive aiming at a target, even from a two-dimensional endoscopic view.

Methods

We developed an ultrasmall COF (1.1-mm diameter) with a central cauterizing laser fiber surrounded by imaging and illumination fibers as a tool for various surgical applications. Porcine mesenteric blood vessels were laser irradiated in vivo and the procedure was filmed using ultrahigh-speed (max 1,000,000 frames per second) and thermographic cameras. Blood flow and vessel diameters were measured before and after laser irradiation.

Results

The target vessels were highly visible and laser energy was delivered to the center of the view. Images from the ultrahigh-speed camera showed the blocking of the target vessel by the laser irradiation. The irradiated point initially became constricted, then discolored, and then decreased in size. Blood flow was decreased by 81.7% after laser irradiation and the diameter of the vessels at the irradiated point was approximately 46–48% smaller than that of the unirradiated vessels. Medical doctors also confirmed that the blood vessel was blocked after the experiments.

Conclusions

Our new laser surgery device may be useful for many surgical applications because it allows simultaneous diagnosis and treatment as well as intuitive aiming at a target despite its ultrasmall 1.1-mm diameter.
Literature
1.
go back to reference Kohl T (2010) Minimally invasive fetoscopic interventions: an overview in 2010. Surg Endosc 24(8):2056–2067PubMedCrossRef Kohl T (2010) Minimally invasive fetoscopic interventions: an overview in 2010. Surg Endosc 24(8):2056–2067PubMedCrossRef
2.
go back to reference Senat MV, Deprest J, Boulvain M, Paupe A, Winer N, Ville Y (2004) Endoscopic laser surgery versus serial amnioreduction for severe twin-to-twin transfusion syndrome. New Engl J Med 351(2):136–144PubMedCrossRef Senat MV, Deprest J, Boulvain M, Paupe A, Winer N, Ville Y (2004) Endoscopic laser surgery versus serial amnioreduction for severe twin-to-twin transfusion syndrome. New Engl J Med 351(2):136–144PubMedCrossRef
3.
go back to reference Noguchi M, Aoki E, Yoshida D, Kobayashi E, Omori S, Muragaki Y, Iseki H, Nakamura K, Sakuma I (2006) A novel robotic laser ablation system for precision neurosurgery with intraoperative 5-ALA-induced PpIX fluorescence detection. Med Image Comput Comput Assist Interv 9(Pt 1):543–550PubMed Noguchi M, Aoki E, Yoshida D, Kobayashi E, Omori S, Muragaki Y, Iseki H, Nakamura K, Sakuma I (2006) A novel robotic laser ablation system for precision neurosurgery with intraoperative 5-ALA-induced PpIX fluorescence detection. Med Image Comput Comput Assist Interv 9(Pt 1):543–550PubMed
4.
go back to reference Shah RJ, Shen JH, Joos KM (2007) Endoscopic free electron laser technique development for minimally invasive optic nerve sheath fenestration. Laser Surg Med 39(7):569–589CrossRef Shah RJ, Shen JH, Joos KM (2007) Endoscopic free electron laser technique development for minimally invasive optic nerve sheath fenestration. Laser Surg Med 39(7):569–589CrossRef
5.
go back to reference Lee J, Gianduzzo TR (2009) Advances in laser technology in urology. Urol Clin North Am 36(2):189–198PubMedCrossRef Lee J, Gianduzzo TR (2009) Advances in laser technology in urology. Urol Clin North Am 36(2):189–198PubMedCrossRef
6.
go back to reference Ansarin M, Santoro L, Cattaneo A, Massaro MA, Calabrese L, Giugliano G, Maffini F, Ostuni A, Chiesa F (2009) Laser surgery for early glottic cancer: impact of margin status on local control and organ preservation. Arch Otolaryngol 135(4):385–390 Ansarin M, Santoro L, Cattaneo A, Massaro MA, Calabrese L, Giugliano G, Maffini F, Ostuni A, Chiesa F (2009) Laser surgery for early glottic cancer: impact of margin status on local control and organ preservation. Arch Otolaryngol 135(4):385–390
7.
go back to reference Pedreira DA, Acácio GL, Drummond CL, Oliveira RC, Deustch AD, Taborda WG (2005) Laser for the treatment of twin to twin transfusion syndrome. Acta Cir Bras 20(6):478–481PubMedCrossRef Pedreira DA, Acácio GL, Drummond CL, Oliveira RC, Deustch AD, Taborda WG (2005) Laser for the treatment of twin to twin transfusion syndrome. Acta Cir Bras 20(6):478–481PubMedCrossRef
8.
go back to reference Oka K, Naganawa A, Yamashita H, Nakamura T, Chiba T (2008) Composite-type optical fiberscope for laser surgery for twin-to-twin transfusion syndrome. Lect Notes Comput Sci 5128:251–259CrossRef Oka K, Naganawa A, Yamashita H, Nakamura T, Chiba T (2008) Composite-type optical fiberscope for laser surgery for twin-to-twin transfusion syndrome. Lect Notes Comput Sci 5128:251–259CrossRef
9.
go back to reference Oka K, Seki T, Naganawa A, Yamashita H, Kim K, Chiba T (2010) The development of composite-type optical fiberscope system for fetoscopic laser photocoagulation of chorionic plate anastomosing vessels (FLPC). Minim Invasive Ther Allied Technol 19(2):94–99PubMedCrossRef Oka K, Seki T, Naganawa A, Yamashita H, Kim K, Chiba T (2010) The development of composite-type optical fiberscope system for fetoscopic laser photocoagulation of chorionic plate anastomosing vessels (FLPC). Minim Invasive Ther Allied Technol 19(2):94–99PubMedCrossRef
10.
go back to reference Seki T, Oka K, Naganawa A, Yamashita H, Kim K, Chiba T (2009) Blood flow measurement system for fetoscopic laser photocoagulation of chorionic plate anastomosing vessels. Minim Invasive Ther Allied Technol 18(6):350–355PubMedCrossRef Seki T, Oka K, Naganawa A, Yamashita H, Kim K, Chiba T (2009) Blood flow measurement system for fetoscopic laser photocoagulation of chorionic plate anastomosing vessels. Minim Invasive Ther Allied Technol 18(6):350–355PubMedCrossRef
11.
go back to reference Seki T, Oka K, Naganawa A, Yamashita H, Kim K, Chiba T (2010) Laser distance measurement using a newly developed composite-type optical fiberscope for fetoscopic laser surgery. Opt Lasers Eng 48:974–977CrossRef Seki T, Oka K, Naganawa A, Yamashita H, Kim K, Chiba T (2010) Laser distance measurement using a newly developed composite-type optical fiberscope for fetoscopic laser surgery. Opt Lasers Eng 48:974–977CrossRef
Metadata
Title
A novel ultrasmall composite optical fiberscope
Authors
Kiyoshi Oka
Takeshi Seki
Akihiro Naganawa
Keri Kim
Toshio Chiba
Publication date
01-07-2011
Publisher
Springer-Verlag
Published in
Surgical Endoscopy / Issue 7/2011
Print ISSN: 0930-2794
Electronic ISSN: 1432-2218
DOI
https://doi.org/10.1007/s00464-010-1540-x

Other articles of this Issue 7/2011

Surgical Endoscopy 7/2011 Go to the issue