Abstract

An intramedullary device has some advantages over external fixation in callus distraction for bone defect reconstruction. There are difficulties controlling motorized intramedullary devices and monitoring the distraction rate which may lead to poor results. The aim of this study was to design a fully implantable and non-motorized simple distraction nail for the treatment of bone defects. The fully implantable device comprises a tube-in-tube system and a wire pulling mechanism for callus distraction. For the treatment of femoral bone defects, a traction wire, attached to the device at one end, is fixed to the tibial tubercle at its other end. Flexion of the knee joint over a predetermined angle generates a traction force on the wire triggering bone segment transport. This callus distraction system was implanted into the femur of four human cadavers (total 8 femora), and bone segment transport was conducted over 60-mm defects with radiographic monitoring. All bone segments were transported reliably to the docking site. From these preliminary results, we conclude that this callus distraction system offers an alternative to the current intramedullary systems for the treatment of bone defects.
Literature
1.
go back to reference Claes L, Veeser A, Gockelmann M, Horvath D, Durselen L, Ignatius A (2010) A novel method for lateral callus distraction and its importance for the mechano-biology of bone formation. Bone 47(4):712–717CrossRefPubMed Claes L, Veeser A, Gockelmann M, Horvath D, Durselen L, Ignatius A (2010) A novel method for lateral callus distraction and its importance for the mechano-biology of bone formation. Bone 47(4):712–717CrossRefPubMed
2.
go back to reference Nayagam S (2010) Femoral lengthening with a rail external fixator: tips and tricks. Strateg Trauma Limb Reconstr 5(3):137–144CrossRef Nayagam S (2010) Femoral lengthening with a rail external fixator: tips and tricks. Strateg Trauma Limb Reconstr 5(3):137–144CrossRef
3.
go back to reference Horas K, Schnettler R, Maier G, Schneider G, Horas U (2015) The role of soft-tissue traction forces in bone segment transport for callus distraction: a force measurement cadaver study on eight human femora using a novel intramedullary callus distraction system. Strateg Trauma Limb Reconstr 10(1):21–26CrossRef Horas K, Schnettler R, Maier G, Schneider G, Horas U (2015) The role of soft-tissue traction forces in bone segment transport for callus distraction: a force measurement cadaver study on eight human femora using a novel intramedullary callus distraction system. Strateg Trauma Limb Reconstr 10(1):21–26CrossRef
5.
go back to reference Ilizarov GA (1989) The tension-stress effect on the genesis and growth of tissues. Part I. The influence of stability of fixation and soft-tissue preservation. Clin Orthop Relat Res 238:249–281PubMed Ilizarov GA (1989) The tension-stress effect on the genesis and growth of tissues. Part I. The influence of stability of fixation and soft-tissue preservation. Clin Orthop Relat Res 238:249–281PubMed
6.
go back to reference Gessmann J, Baecker H, Jettkant B, Muhr G, Seybold D (2011) Direct and indirect loading of the Ilizarov external fixator: the effect on the interfragmentary movements and compressive loads. Strateg Trauma Limb Reconstr 6(1):27–31CrossRef Gessmann J, Baecker H, Jettkant B, Muhr G, Seybold D (2011) Direct and indirect loading of the Ilizarov external fixator: the effect on the interfragmentary movements and compressive loads. Strateg Trauma Limb Reconstr 6(1):27–31CrossRef
7.
go back to reference Mekhail AO, Abraham E, Gruber B, Gonzalez M (2004) Bone transport in the management of posttraumatic bone defects in the lower extremity. J Trauma 56(2):368–378CrossRefPubMed Mekhail AO, Abraham E, Gruber B, Gonzalez M (2004) Bone transport in the management of posttraumatic bone defects in the lower extremity. J Trauma 56(2):368–378CrossRefPubMed
8.
go back to reference Oh CW, Song HR, Roh JY, Oh JK, Min WK, Kyung HS, Kim JW, Kim PT, Ihn JC (2008) Bone transport over an intramedullary nail for reconstruction of long bone defects in tibia. Arch Orthop Trauma Surg 128(8):801–808CrossRefPubMed Oh CW, Song HR, Roh JY, Oh JK, Min WK, Kyung HS, Kim JW, Kim PT, Ihn JC (2008) Bone transport over an intramedullary nail for reconstruction of long bone defects in tibia. Arch Orthop Trauma Surg 128(8):801–808CrossRefPubMed
9.
go back to reference Sun XT, Easwar TR, Manesh S, Ryu JH, Song SH, Kim SJ, Song HR (2011) Complications and outcome of tibial lengthening using the Ilizarov method with or without a supplementary intramedullary nail: a case-matched comparative study. J Bone Joint Surg Br 93(6):782–787CrossRefPubMed Sun XT, Easwar TR, Manesh S, Ryu JH, Song SH, Kim SJ, Song HR (2011) Complications and outcome of tibial lengthening using the Ilizarov method with or without a supplementary intramedullary nail: a case-matched comparative study. J Bone Joint Surg Br 93(6):782–787CrossRefPubMed
10.
go back to reference Liantis P, Mavrogenis AF, Stavropoulos NA, Kanellopoulos AD, Papagelopoulos PJ, Soucacos PN, Babis GC (2014) Risk factors for and complications of distraction osteogenesis. Eur J Orthop Surg Traumatol 5:693–698CrossRef Liantis P, Mavrogenis AF, Stavropoulos NA, Kanellopoulos AD, Papagelopoulos PJ, Soucacos PN, Babis GC (2014) Risk factors for and complications of distraction osteogenesis. Eur J Orthop Surg Traumatol 5:693–698CrossRef
11.
go back to reference Guichet JM, Deromedis B, Donnan LT, Peretti G, Lascombes P, Bado F (2003) Gradual femoral lengthening with the Albizzia intramedullary nail. J Bone Joint Surg Am 85-A(5):838–848PubMed Guichet JM, Deromedis B, Donnan LT, Peretti G, Lascombes P, Bado F (2003) Gradual femoral lengthening with the Albizzia intramedullary nail. J Bone Joint Surg Am 85-A(5):838–848PubMed
12.
go back to reference Betz A, Baumgart R, Schweiberer L (1990) First fully implantable intramedullary system for callus distraction–intramedullary nail with programmable drive for leg lengthening and segment displacement. Principles and initial clinical results. Der Chirurg; Zeitschrift fur alle Gebiete der operativen Medizien 61(8):605–609 Betz A, Baumgart R, Schweiberer L (1990) First fully implantable intramedullary system for callus distraction–intramedullary nail with programmable drive for leg lengthening and segment displacement. Principles and initial clinical results. Der Chirurg; Zeitschrift fur alle Gebiete der operativen Medizien 61(8):605–609
13.
go back to reference Cole JD, Justin D, Kasparis T, DeVlught D, Knobloch C (2001) The intramedullary skeletal kinetic distractor (ISKD): first clinical results of a new intramedullary nail for lengthening of the femur and tibia. Injury 32(Suppl 4):SD129–SD139CrossRefPubMed Cole JD, Justin D, Kasparis T, DeVlught D, Knobloch C (2001) The intramedullary skeletal kinetic distractor (ISKD): first clinical results of a new intramedullary nail for lengthening of the femur and tibia. Injury 32(Suppl 4):SD129–SD139CrossRefPubMed
14.
go back to reference Konofaos P, Kashyap A, Neel MD, Ver Halen JP (2012) A novel device for long bone osteodistraction: description of device and case series. Plast Reconstr Surg 130(3):418e–422eCrossRefPubMed Konofaos P, Kashyap A, Neel MD, Ver Halen JP (2012) A novel device for long bone osteodistraction: description of device and case series. Plast Reconstr Surg 130(3):418e–422eCrossRefPubMed
15.
go back to reference Baumgart R, Betz A, Schweiberer L (1997) A fully implantable motorized intramedullary nail for limb lengthening and bone transport. Clin Orthop Relat Res 343:135–143CrossRefPubMed Baumgart R, Betz A, Schweiberer L (1997) A fully implantable motorized intramedullary nail for limb lengthening and bone transport. Clin Orthop Relat Res 343:135–143CrossRefPubMed
16.
go back to reference Garcia-Cimbrelo E, Curto de la Mano A, Garcia-Rey E, Cordero J, Marti-Ciruelos R (2002) The intramedullary elongation nail for femoral lengthening. J Bone Joint Surg Br 84(7):971–977CrossRefPubMed Garcia-Cimbrelo E, Curto de la Mano A, Garcia-Rey E, Cordero J, Marti-Ciruelos R (2002) The intramedullary elongation nail for femoral lengthening. J Bone Joint Surg Br 84(7):971–977CrossRefPubMed
17.
go back to reference Schiedel FM, Pip S, Wacker S, Popping J, Tretow H, Leidinger B, Rodl R (2011) Intramedullary limb lengthening with the Intramedullary Skeletal Kinetic Distractor in the lower limb. J Bone Joint Surg Br 93(6):788–792CrossRefPubMed Schiedel FM, Pip S, Wacker S, Popping J, Tretow H, Leidinger B, Rodl R (2011) Intramedullary limb lengthening with the Intramedullary Skeletal Kinetic Distractor in the lower limb. J Bone Joint Surg Br 93(6):788–792CrossRefPubMed
18.
go back to reference Simpson AH, Shalaby H, Keenan G (2009) Femoral lengthening with the Intramedullary Skeletal Kinetic Distractor. J Bone Joint Surg Br 91(7):955–961CrossRefPubMed Simpson AH, Shalaby H, Keenan G (2009) Femoral lengthening with the Intramedullary Skeletal Kinetic Distractor. J Bone Joint Surg Br 91(7):955–961CrossRefPubMed
19.
go back to reference Kenawey M, Krettek C, Liodakis E, Wiebking U, Hankemeier S (2011) Leg lengthening using intramedullay skeletal kinetic distractor: results of 57 consecutive applications. Injury 42(2):150–155CrossRefPubMed Kenawey M, Krettek C, Liodakis E, Wiebking U, Hankemeier S (2011) Leg lengthening using intramedullay skeletal kinetic distractor: results of 57 consecutive applications. Injury 42(2):150–155CrossRefPubMed
20.
go back to reference Burghardt RD, Herzenberg JE, Specht SC, Paley D (2011) Mechanical failure of the Intramedullary Skeletal Kinetic Distractor in limb lengthening. J Bone Joint Surg Br 93(5):639–643CrossRefPubMed Burghardt RD, Herzenberg JE, Specht SC, Paley D (2011) Mechanical failure of the Intramedullary Skeletal Kinetic Distractor in limb lengthening. J Bone Joint Surg Br 93(5):639–643CrossRefPubMed
21.
go back to reference Masquelet AC, Fitoussi F, Begue T, Muller GP (2000) Reconstruction of the long bones by the induced membrane and spongy autograft. Ann Chir Plast Esthet 45(3):346–353PubMed Masquelet AC, Fitoussi F, Begue T, Muller GP (2000) Reconstruction of the long bones by the induced membrane and spongy autograft. Ann Chir Plast Esthet 45(3):346–353PubMed
22.
go back to reference Bieler D, Franke A, Willms A, Hentsch S, Kollig E (2014) Masquelet technique for reconstruction of osseous defects in a gunshot fracture of the proximal thigh-a case study. Mil Med 179(9):e1053–e1058CrossRefPubMed Bieler D, Franke A, Willms A, Hentsch S, Kollig E (2014) Masquelet technique for reconstruction of osseous defects in a gunshot fracture of the proximal thigh-a case study. Mil Med 179(9):e1053–e1058CrossRefPubMed
23.
go back to reference Horas U (2006) A novel internal callus distraction system. In: Leung KTG, Schnettler R, Alt V, Haarman HJTM (eds) Practice of Intramedullary Locked Nails. Springer, Berlin, pp 199–210CrossRef Horas U (2006) A novel internal callus distraction system. In: Leung KTG, Schnettler R, Alt V, Haarman HJTM (eds) Practice of Intramedullary Locked Nails. Springer, Berlin, pp 199–210CrossRef
24.
go back to reference Contzen H (1987) Development of intramedullary nailing and the interlocking nail. Aktuelle Traumatologie 17(6):250–252PubMed Contzen H (1987) Development of intramedullary nailing and the interlocking nail. Aktuelle Traumatologie 17(6):250–252PubMed
25.
go back to reference Menzel M (2004) Experimentelle Untersuchung zur Belastbarkeit und Funktion eines neuen Kallusdistraktionssystems unter Berücksichtigung der biologischen Rahmenbedingungen des Knochensegmenttransports. Dissertation, Justus-Liebig Universität, Giessen Menzel M (2004) Experimentelle Untersuchung zur Belastbarkeit und Funktion eines neuen Kallusdistraktionssystems unter Berücksichtigung der biologischen Rahmenbedingungen des Knochensegmenttransports. Dissertation, Justus-Liebig Universität, Giessen
26.
go back to reference Schandelmaier P, Krettek C, Tscherne H (1996) Biomechanical study of nine different tibia locking nails. J Orthop Trauma 10(1):37–44CrossRefPubMed Schandelmaier P, Krettek C, Tscherne H (1996) Biomechanical study of nine different tibia locking nails. J Orthop Trauma 10(1):37–44CrossRefPubMed
27.
go back to reference Schandelmaier P, Farouk O, Krettek C, Reimers N, Mannss J, Tscherne H (2000) Biomechanics of femoral interlocking nails. Injury 31(6):437–443CrossRefPubMed Schandelmaier P, Farouk O, Krettek C, Reimers N, Mannss J, Tscherne H (2000) Biomechanics of femoral interlocking nails. Injury 31(6):437–443CrossRefPubMed
28.
go back to reference Hankemeier S, Pape HC, Gosling T, Hufner T, Richter M, Krettek C (2004) Improved comfort in lower limb lengthening with the intramedullary skeletal kinetic distractor. Principles and preliminary clinical experiences. Arch Orthop Trauma Surg 124(2):129–133CrossRefPubMed Hankemeier S, Pape HC, Gosling T, Hufner T, Richter M, Krettek C (2004) Improved comfort in lower limb lengthening with the intramedullary skeletal kinetic distractor. Principles and preliminary clinical experiences. Arch Orthop Trauma Surg 124(2):129–133CrossRefPubMed
29.
go back to reference Zhang X, Liu T, Li Z, Peng W (2007) Reconstruction with callus distraction for nonunion with bone loss and leg shortening caused by suppurative osteomyelitis of the femur. J Bone Joint Surg Br 89(11):1509–1514CrossRefPubMed Zhang X, Liu T, Li Z, Peng W (2007) Reconstruction with callus distraction for nonunion with bone loss and leg shortening caused by suppurative osteomyelitis of the femur. J Bone Joint Surg Br 89(11):1509–1514CrossRefPubMed
30.
go back to reference Hyodo A, Kotschi H, Kambic H, Muschler G (1996) Bone transport using intramedullary fixation and a single flexible traction cable. Clin Orthop Relat Res 325:256–268CrossRefPubMed Hyodo A, Kotschi H, Kambic H, Muschler G (1996) Bone transport using intramedullary fixation and a single flexible traction cable. Clin Orthop Relat Res 325:256–268CrossRefPubMed
31.
go back to reference Paley D, Herzenberg JE, Paremain G, Bhave A (1997) Femoral lengthening over an intramedullary nail. A matched-case comparison with Ilizarov femoral lengthening. J Bone Joint Surg Am 79(10):1464–1480PubMed Paley D, Herzenberg JE, Paremain G, Bhave A (1997) Femoral lengthening over an intramedullary nail. A matched-case comparison with Ilizarov femoral lengthening. J Bone Joint Surg Am 79(10):1464–1480PubMed
32.
go back to reference Kocaoglu M, Eralp L, Bilen FE, Balci HI (2009) Fixator-assisted acute femoral deformity correction and consecutive lengthening over an intramedullary nail. J Bone Joint Surg Am 91(1):152–159CrossRefPubMed Kocaoglu M, Eralp L, Bilen FE, Balci HI (2009) Fixator-assisted acute femoral deformity correction and consecutive lengthening over an intramedullary nail. J Bone Joint Surg Am 91(1):152–159CrossRefPubMed
33.
go back to reference Brunner UH, Cordey J, Kessler S, Rahn BA, Schweiberer L, Perren SM (1993) Bone segment transport in combination with an intramedullary nail. Injury 24(Suppl 2):S29–S44CrossRefPubMed Brunner UH, Cordey J, Kessler S, Rahn BA, Schweiberer L, Perren SM (1993) Bone segment transport in combination with an intramedullary nail. Injury 24(Suppl 2):S29–S44CrossRefPubMed
34.
go back to reference Liodakis E, Kenawey M, Krettek C, Wiebking U, Hankemeier S (2011) Comparison of 39 post-traumatic tibia bone transports performed with and without the use of an intramedullary rod: the long-term outcomes. Int Orthop 35(9):1397–1402CrossRefPubMed Liodakis E, Kenawey M, Krettek C, Wiebking U, Hankemeier S (2011) Comparison of 39 post-traumatic tibia bone transports performed with and without the use of an intramedullary rod: the long-term outcomes. Int Orthop 35(9):1397–1402CrossRefPubMed
35.
go back to reference Paley D (2015) PRECICE intramedullary limb lengthening system. Expert Rev Med Devices 12(3):231–249CrossRefPubMed Paley D (2015) PRECICE intramedullary limb lengthening system. Expert Rev Med Devices 12(3):231–249CrossRefPubMed
36.
37.
go back to reference Singh S, Lahiri A, Iqbal M (2006) The results of limb lengthening by callus distraction using an extending intramedullary nail (Fitbone) in non-traumatic disorders. J Bone Joint Surg Br 88(7):938–942CrossRefPubMed Singh S, Lahiri A, Iqbal M (2006) The results of limb lengthening by callus distraction using an extending intramedullary nail (Fitbone) in non-traumatic disorders. J Bone Joint Surg Br 88(7):938–942CrossRefPubMed
40.
go back to reference Claes L, Augat P, Schorlemmer S, Konrads C, Ignatius A, Ehrnthaller C (2008) Temporary distraction and compression of a diaphyseal osteotomy accelerates bone healing. J Orthop Res 26(6):772–777CrossRefPubMed Claes L, Augat P, Schorlemmer S, Konrads C, Ignatius A, Ehrnthaller C (2008) Temporary distraction and compression of a diaphyseal osteotomy accelerates bone healing. J Orthop Res 26(6):772–777CrossRefPubMed
41.
go back to reference Gessmann J, Citak M, Jettkant B, Schildhauer TA, Seybold D (2011) The influence of a weight-bearing platform on the mechanical behavior of two Ilizarov ring fixators: tensioned wires vs. half-pins. J Orthop Surg Res 6:61CrossRefPubMedPubMedCentral Gessmann J, Citak M, Jettkant B, Schildhauer TA, Seybold D (2011) The influence of a weight-bearing platform on the mechanical behavior of two Ilizarov ring fixators: tensioned wires vs. half-pins. J Orthop Surg Res 6:61CrossRefPubMedPubMedCentral
42.
go back to reference Taylor SJ, Walker PS (2001) Forces and moments telemetered from two distal femoral replacements during various activities. J Biomech 34(7):839–848CrossRefPubMed Taylor SJ, Walker PS (2001) Forces and moments telemetered from two distal femoral replacements during various activities. J Biomech 34(7):839–848CrossRefPubMed
43.
go back to reference Taylor SJ, Perry JS, Meswania JM, Donaldson N, Walker PS, Cannon SR (1997) Telemetry of forces from proximal femoral replacements and relevance to fixation. J Biomech 30(3):225–234CrossRefPubMed Taylor SJ, Perry JS, Meswania JM, Donaldson N, Walker PS, Cannon SR (1997) Telemetry of forces from proximal femoral replacements and relevance to fixation. J Biomech 30(3):225–234CrossRefPubMed
Metadata
Title
A novel intramedullary callus distraction system for the treatment of femoral bone defects
Authors
Konstantin Horas
Reinhard Schnettler
Gerrit Maier
Uwe Horas
Publication date
01-08-2016
Publisher
Springer Milan
Published in
Strategies in Trauma and Limb Reconstruction / Issue 2/2016
Print ISSN: 1828-8936
Electronic ISSN: 1828-8928
DOI
https://doi.org/10.1007/s11751-016-0255-5

Other articles of this Issue 2/2016

Strategies in Trauma and Limb Reconstruction 2/2016 Go to the issue

Acknowledgment to Referees

Reviewers 2015